Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mechanical strain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Expression of Novel Gene Products Upregulated by Disuse is Normalized by an Osteogenic Mechanical Stimulus: Evidence for the Molecular Basis of a Low Level Biomechanical Countermeasure for Osteoporosis?

The National Research Council's report entitled: A Strategy for Space Biology and Medical Science, highlighted several areas of fundamental scientific investigation which must be addressed to make long-term space exploration not only feasible, but safe. This "Goldberg Strategy," as well as several subsequent reports published by the NRC's Space Studies Board (e.g., Assessment of Programs in Space Biology and Medicine, Smith et. al., 1991), suggests that the principal hurdle to man's extended presence in space is the osteopenia which parallels reduced gravity. Ironically, the most significant risk to the skeleton may only be realized on return to normal gravitational fields, and full recovery of bone mass may never occur. Effective counter-measures to this microgravity induced bone loss are thus essential. Considering the similarities of space and aging induced osteopenia, an indisputable benefit of such a prophylaxis would be its potential as a treatment for the bone loss which plagues over 25 million people in the U.S. The osteogenic potential of mechanical strain is strongly frequency dependent, with sensitivity increasing up through at least 60 Hz (cycles per second). One hundred seconds per day of a 1 Hz cyclic loading will inhibit disuse osteopenia only if sufficient in magnitude to engender 1000 microstrain (mu(epsilon)) in the tissue. When loading is applied at 30 Hz, however, mechanical strains on the order of 5O mu(epsilon) (approx. 1% of the peak strains which occur in bone during vigorous functional activity), can stimulate bone formation in a duration dependent manner. In longer term animal studies, strains of less than 10 mu(epsilon), induced non-invasively via a whole body vibration, will stimulate bone formation on the surfaces of trabeculae, increase bone density, and improve strength. Finally, preliminary results from a double blind prospective clinical trial shows promise in inhibiting the bone loss which parallels the menopause. Based on these observations, we propose that these high frequency, low magnitude, mechanical strains effectively serve as a "surrogate" for musculoskeletal ground reaction forces, and thus represent an ideal countermeasure to the osteopenia which parallels microgravity conditions. The specific goal of this NASA funded work is to identify genes in bone upregulated by disuse, and to determine the efficacy of an osteogenic mechanical stimulus to downregulate their expression.

Rubin, C.↗

The use of heterodyne speckle photogrammetry to measure high-temperature strain distributions

Thermal and mechanical strains have been measured on samples of a common material used in jet engine burner liners, which were heated from room temperature to 870 C and cooled back to 220 C, in a laboratory furnace. The physical geometry of the sample surface was recorded to select temperatures by means of a set of twelve single-exposure specklegrams. Sequential pairs of specklegrams were compared in a heterodyne interferometer which allowed high-precision measurement of differential displacements. Good speckle correlation was observed between the first and last specklegrams also, which showed the durability of the surface microstructure, and permitted a check on accumulated errors. Agreement with calculated thermal expansion was to within a few hundred microstrain over a range of fourteen thousand.

Stetson, K. A.↗

Laser speckle technique for burner liner strain measurements

Thermal and mechanical strains were measured on samples of a common material used in jet engine burner liners, which were heated from room temperature to 870 C and cooled back to 220 C, in a laboratory furnance. The physical geometry of the sample surface was recorded at selected temperatures by a set of 12 single exposure speckle-grams. Sequential pairs of specklegrams were compared in a heterodyne interferometer which give high precision measurement of differential displacements. Good speckle correlation between the first and last specklegrams is noted which allows a check on accumulate errors.

Stetson, K. A.↗

Thermal and stress analysis of thermal barrier coatings

An analysis has been performed that predicts the thermomechanical behavior of thermal barrier coated specimens. The analysis predicts the behavior during both plasma spray coating application and burner rig testing conditions simulating engine operation. The analysis was accomplished through utilization of one-dimensional through thickness and two-dimensional finite element calculations. The results of these calculations showed that specimens with a substrate control temperature between 300 F and 600 F would be optimum. Controlling substrate temperature was found to have a more dominant effect on the mechanical strains than the ceramic or substrate thicknesses. The predicted stresses and mechanical strains at the bond-coating interface are large enough to cause cracks in this region where post-test observations have determined coating failures originate.

Cassenti, B. N.↗

Strain analysis of the Leoville chondrite and conditions in asteroidal interiors

Deformed chondrules in the Leoville carbonaceous chondrite define a preferred orientation, also recognized previously in other CV3 chondrites. Identifying the strain mechanism is necessary for understanding the conditions which caused this compressional shortening. Luckly, the major mineralogical constituent of CV3 meteorites is olivine, for which experimental data on strain mechanisms exist. The conditions that caused strain in the olivine were obviously applicable to the whole meteorite. Possible mechanisms of olivine deformation are cataclasis, low temperature plasticity, power low creep, and diffusional flow, each of which occurs under different combinations of temperature and deviatoric stress. Cataclasis can be ruled out on the basis of its high deviatoric stress requirements; some fractures occur in chondrule olivines, but these may have formed during excavation or impact. Low temperature plasticity and power low creep occur by means of various types of lattice dislocations. However, methods of thermal decoration and chemical etching of dislocations failed to indicate evidence for either mechanism. Thus, the inference is that diffusional flow, characteristic of low to moderately high temperatures and low deviatoric stress, was the major deformation mechanism.

Cain, P. M.↗

High temperature strain gage apparent strain compensation

Once an installed strain gage is connected to a strain indicating device and the instrument is balanced, a subsequent change in temperature of the gage installation will generally produce a resistance change in the gage. This purely temperature-induced resistance will be registered by the indicating device as a strain and is referred to as 'apparent strain' to distinguish it from strain due to applied stress. One desirable technique for apparent strain compensation is to employ two identical gages with identical mounting procedures which are connected with a 'half bridge' configuration where gages see the same thermal environment but only one experiences a mechanical strain input. Their connection in adjacent arms of the bridge will then balance the thermally induced apparent strains and, in principle, only the mechanical strain remains. Two approaches that implement this technique are discussed.

Holmes, Harlan K.↗

Hydrogen Permeability of Polymer Matrix Composites at Cryogenic Temperatures

This paper presents experimental methods and results of an ongoing study of the correlation between damage state and hydrogen gas permeability of laminated composite materials under mechanical strains and thermal loads. A specimen made from IM-7/977-2 composite material has been mechanically cycled at room temperature to induce microcrack damage. Crack density and tensile modulus were observed as functions of number of cycles. Damage development was found to occur most quickly in the off-axis plies near the outside of the laminate. Permeability measurements were made after 170,000 cycles and 430,000 cycles. Leak rate was found to depend on applied mechanical strain, crack density, and test temperature.

Grenoble, Ray W.↗

Bithermal fatigue: A simplified alternative to thermomechanical fatigue

A bithermal fatigue test technique was proposed as a simplified alternative to the thermomechanical fatigue test. Both the thermomechanical cycle and the bithermal technique can be used to study nonisothermal fatigue behavior. The difference between the two cycles is that in a conventional thermomechanical fatigue cycle the temperature is continuously varied concurrently with the applied mechanical strains, but in the bithermal fatigue cycle the specimen is held at zero load during the temperature excursions and all the loads are applied at the two extreme temperatures of the cycle. Experimentally, the bithermal fatigue test technique offers advantages such as ease in synchronizing the temperature and mechanical strain waveforms, in minimizing temperature gradients in the specimen gauge length, and in reducing and interpreting thermal fatigue such as the influence of alternate high and low temperatures on the cyclic stress-strain response characteristics, the effects of thermal state, and the possibility of introducing high- and low-temperature deformation mechanisms within the same cycle. The bithermal technique was used to study nonisothermal fatigue behavior of alloys such as single-crystal PWA 1480, single-crystal Rene N4, cast B1900+Hf, and wrought Haynes 188.

Verrilli, Michael J.↗

Effects of Zoledronate and Mechanical Loading during Simulated Weightlessness on Bone Structure and Mechanical Properties

Space flight modulates bone remodeling to favor bone resorption. Current countermeasures include an anti-resorptive drug class, bisphosphonates (BP), and high-force loading regimens. Does the combination of anti-resorptives and high-force exercise during weightlessness have negative effects on the mechanical and structural properties of bone? In this study, we implemented an integrated model to mimic mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hindlimb unloading (HU). Our working hypothesis is that CL combined with ZOL in the HU model induces additive structural and mechanical changes. Thirty-two C57BL6 mice (male,16 weeks old, n8group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45gkg), or saline vehicle, prior to experiment. The right tibia was axially loaded in vivo, 60xday to 9N in compression, repeated 3xweek during HU. During the application of compression, secant stiffness (SEC), a linear estimate of slope of the force displacement curve from rest (0.5N) to max load (9.0N), was calculated for each cycle once per week. Ex vivo CT was conducted on all subjects. For ex vivo mechanical properties, non-CL left femurs underwent 3-point bending. In the proximal tibial metaphysis, HU decreased, CL increased, and ZOL increased the cancellous bone volume to total volume ratio by -26, +21, and +33, respectively. Similar trends held for trabecular thickness and number. Ex vivo left femur mechanical properties revealed HU decreased stiffness (-37),and ZOL mitigated the HU stiffness losses (+78). Data on the ex vivo Ultimate Force followed similar trends. After 3 weeks, HU decreased in vivo SEC (-16). The combination of CL+HU appeared additive in bone structure and mechanical properties. However, when HU + CL + ZOL were combined, ZOL had no additional effect (p0.05) on in vivo SEC. Structural data followed this trend with ZOL not modulating trabecular thickness in CL + NAHU mice. In summary, our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. Based on these results, we conclude that, at the structural and stiffness level, zoledronate treatment during simulated spaceflight does not impede the skeletal response to axial compression. In contrast to our hypothesis, our data show that zoledronate confers no additional mechanical or structural benefit beyond those gained from cyclical loading.

Mechanical Loading↗

Exploratory Thermal-mechanical Fatigue Results for Rene' 80 in Ultrahigh Vacuum

A limited study was conducted of the use of strainage partitioning for predicting the thermalmechanical fatigue life of cast nickel-base superalloy Rene' 80. The fatigue lives obtained by combined inphase thermal and mechanical strain cycling between 400 C (752 F) and 1000 C (1802 F) in an ultrahigh vacuum were considerably shorter than those represented by the four basic partitioned inelastic strainrange fatigue life relationships established previously for this alloy at 871 C (1600 F) and 1000 C (1832 F) in an ultrahigh vacuum. This behavior was attributed to the drastic decrease in ductility with decreasing temperature for this alloy. These results indicated that the prediction of the thermal-mechanical fatigue life of Rene' 80 by the method of strainrange partioning may be improved if based on the four basic fatigue life relationships determined at a lower temperature in the thermal-mechanical strain cycle.

Sheinker, A. A.↗

Zoledronate Prevents Simulated Weightlessness-Induced Bone Loss in the Cancellous Compartment While Blunting the Efficacy of a Mechanical Loading Countermeasure

Astronauts using high-force resistance training while weightless show a high-turnover remodeling state within the skeletal system, with resorption and formation biomarkers being elevated. One countermeasure for the skeletal health of astronauts includes an antiresorptive of the bisphosphonate (BP) drug class. We asked, does the combination of an anti-resorptive and high-force exercise during weightlessness have negative effects on bone remodeling and strength? In this study, we developed an integrated model to mimic the mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hind limb unloading (HU) to simulate weightlessness. We hypothesized that ZOL prevents structural degradation from simulated weightlessness and that CL and ZOL interact to render CL less effective. Thirty-two C57BL/6 mice (male, 16 weeks old, n=8/group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45μg/kg), or saline vehicle (VEH), prior to the start of HU. The right tibia was axially compressed in vivo 60x/day to 9N (+1200μstrain on the periosteal surface) and repeated 3x/week during HU. Left tibiae served as a within subject, non-compressed control. Ex vivo μCT was performed on all subjects to determine cancellous and cortical architectural parameters. Static and dynamic histomorphometry were carried out for the left and right tibiae to determine osteoclast- and osteoblast relevant surfaces. Further, micro damage was assessed in select groups by basic-fuchsin staining to test whether CL had an effect. For all assays, a multivariate (2x2x2) ANCOVA model was used to account for body weight changes. Additionally, for the tibiae, we incorporated a random effect for the subject (hence, a mixed model) to account for observations of both left and right tibiae within each subject. P < 0.05 was considered significant. In the cancellous compartment of the proximal tibial metaphysis, we observed a main effect from each independent variable, as determined by structural and histomorphometric assays. Specifically, as expected, ZOL showed an increase in the cancellous bone volume to total volume fraction (BV/TV, +32%) and trabecular number (+18%) compared to the VEH. As expected, ZOL decreased osteoclast surface (OC/BS) by -45% compared to VEH. Surprisingly, ZOL reduced mineralizing surface (MS/BS) and bone formation rate (BFR), indicators of osteoblast activity, by -40% and -54%, respectively, compared to VEH. Altogether, ZOL-treated mice displayed a low turnover state of remodeling in the metaphysis. In the context of skeletal aging, we speculate that ZOL prevented age-related cancellous strut loss during the experiment. As a main effect, as expected, HU decreased BV/TV by - 31% via reductions in both trabecular thickness (-11%) and number (-22%) compared to NA controls. Additionally, HU decreased MS/BS by -38% and bone formation rate (BFR) by -50% compared to NA controls. Altogether, these data are consistent with structural degradation resulting from imbalanced remodeling that favors resorption. As a main effect, CL increased BV/TV by +15% via increased trabecular thickness (+12%) compared to the noncompressed limb. As expected, CL increased MS/BS (+20%) and BFR (+24%), indicating osteoblast mineralization contributed to bone gains. These data show that CL provided an anabolic stimulus to the cancellous tissue. We observed unique interactions in ZOL*CL and HU*CL. First, ZOL prevented CL-induced increases in BV/TV and trabecular number, as compared to VEH. In the context of skeletal aging, these data suggest no added benefit from CL in the ZOL-treated mice. Interestingly, no microdamage was observed in mice that were unloaded and treated with ZOL (independent of CL). Secondly, HU prevented CL-induced increases in BFR, as compared to NA controls. These data suggest that either exercise is less effective or the kinetics of formation are slower during simulated weightlessness. Osteoclast surface was unchanged by either treatment. Thus, in contrast to exercising astronauts, these data do not suggest a high-turnover state in the metaphysis. To assess mechanical properties as a function of HU or ZOL, we tested the left femur in three-point bending ex vivo. As expected, HU decreased stiffness (-30%) compared to NA, and ZOL increased stiffness compared to VEH (+28%). Interestingly, HU increased the post-yield displacement, related to collagenous tensile loading, compared to NA (+20%). ZOL increased yield force (+11%) and ultimate force (+17%), which seems to explain the significant effect of ZOL increasing total energy (work-to-fracture, +15%), while not affecting the post yield displacement. Taken together, ZOL did not have detrimental affect on mechanical properties. Our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. We conclude that Zoledronate was an effective countermeasure against weightlessness-induced bone loss, though zoledronate, as well as weightlessness, rendered exercise-related mechanical loading less effective.

bone↗

Strain partitioning of three alloys in ultrahigh vacuum using the step stress method

The ultrahigh vacuum strain controlled thermal-mechanical strain cycling fatigue behavior of ASTAR 811C, 304 stainless steel and A-286 was studied. The step stress procedure of experimental strainrange partitioning was utilized to partition the inelastic strainranges for tests duplicating conditionings previously reported by TRW. An analytical method is described in which these partitioned inelastic strainrange data can be used to develop the four basic life relationships for these materials.

Kortovich, C. S.↗

Modulation of bone remodeling via mechanically activated ion channels

A critical factor in the maintenance of bone mass is the physical forces imposed upon the skeleton. Removal of these forces, such as in a weightless environment, results in a rapid loss of bone, whereas application of exogenous mechanical strain has been shown to increase bone formation. Numerous flight and ground-based experiments indicate that the osteoblast is the key bone cell influenced by mechanical stimulation. Aside from early transient fluctuations in response to unloading, osteoclast number and activity seem unaffected by removal of strain. However, bone formation is drastically reduced in weightlessness and osteoblasts respond to mechanical strain with an increase in the activity of a number of second messenger pathways resulting in increased anabolic activity. Unfortunately, the mechanism by which the osteoblast converts physical stimuli into a biochemical message, a process we have termed biochemical coupling, remains elusive. Prior to the application of this grant, we had characterized a mechanosensitive, cation nonselective channel (SA-cat) in osteoblast-like osteosarcoma cells that we proposed is the initial signalling mechanism for mechanotransduction. During the execution of this grant, we have made considerable progress to further characterize this channel as well as to determine its role in the osteoblastic response to mechanical strain. To achieve these goals, we combined electrophysiologic techniques with cellular and molecular biology methods to examine the role of these channels in the normal function of the osteoblast in vitro.

Duncan, Randall L.↗

Nonlinear effects on composite laminate thermal expansion

Analyses of Graphite/Polyimide laminates shown that the thermomechanical strains cannot be separated into mechanical strain and free thermal expansion strain. Elastic properties and thermal expansion coefficients of unidirectional Graphite/Polyimide specimens were measured as a function of temperature to provide inputs for the analysis. The + or - 45 degrees symmetric Graphite/Polyimide laminates were tested to obtain free thermal expansion coefficients and thermal expansion coefficients under various uniaxial loads. The experimental results demonstrated the effects predicted by the analysis, namely dependence of thermal expansion coefficients on load, and anisotropy of thermal expansion under load. The significance of time dependence on thermal expansion was demonstrated by comparison of measured laminate free expansion coefficients with and without 15 day delay at intermediate temperature.

Hashin, Z.↗

The Role of Calcium in the Response of Osteoblasts to Mechanical Stimulation

A major biomedical concern in the exploration and development of space is the rapid loss of bone associated with extended periods of spaceflight. Mineral content, bone formation, matrix protein production and total body calcium are all reduced during long-term periods of weightlessness. These effects of weightlessness appears to be due to decreases in the anabolic function of osteoblasts and osteocytes rather than changes in the resorptive activity of osteoclasts. Conversely, subjecting the skeleton to exogenous mechanical loading increases matrix protein synthesis and bone formation rate, a process which also appears mediated through osteogenic cells. Osteoblasts have been shown to respond to a number of types of mechanical stimulation. However recently we have demonstrated that osteoblasts respond to fluid shear, but not physiologic levels of mechanical strain, with increases in expression of the matrix protein, osteopontin. We have also shown similar responses in other markers for the anabolic response in bone. The expression of the early response gene, c-fos, and the inducible-isoform of the prostaglandin synthetic enzyme, cyclooygenase-2 (COX-2), both increase rapidly in response to fluid shear, but not strain. How osteoblasts and osteocytes perceive mechanical stimuli and convert this stimulus into a biochemical event within the cell is still unknown. However, examination of the cellular events following mechanical stimulation indicate that two of the earliest responses are a rapid increase in intracellular calcium ([Ca(2+)](sub i)) and a reorganization of the actin cytoskeleton. The increase in [Ca(2+)](sub i) is dependent on the presence of extracellular Ca(2+), suggesting the activation of membrane Ca(2+) channel. We have previously characterized a mechanosensitive, cation-selective channel (MSCC) in osteoblast-like clonal cells, which we postulate is important in this early response to mechanical loading. Using an antisense oligodeoxynucleotide strategy, we have tentatively identified this channel as an isoform of the alc subunit of the dihydropyridine-sensitive, voltage sensitive Ca(2+) channel (VSCC). However, a major component in this mechanically induced rise in [Ca(2+)](sub i) is the release of Ca(2+) from intracellular stores. The actin cytoskeleton also rapidly responds to fluid shear with an increase in stress fiber formation and a realignment of the cell parallel to the direction of flow. To ascertain whether these two observations are related and how they effect shear-induced gene expression, we examined the role of Ca(2+) channels and intracellular Ca(2+) release on cytoskeletal reorganization and the resultant increases in the expression and production of c-fos and COX-2 in response to fluid shear.

Duncan, R. L.↗

Evaluation of Microbolometer-Based Thermography for Gossamer Space Structures

In August 2003, NASA's In-Space Propulsion Program contracted with our team to develop a prototype on-board Optical Diagnostics System (ODS) for solar sail flight tests. The ODS is intended to monitor sail deployment as well as structural and thermal behavior, and to validate computational models for use in designing future solar sail missions. This paper focuses on the thermography aspects of the ODS. A thermal model was developed to predict local sail temperature variations as a function of sail tilt to the sun, billow depth, and spectral optical properties of front and back sail surfaces. Temperature variations as small as 0.5 C can induce significant thermal strains that compare in magnitude to mechanical strains. These thermally induced strains may result in changes in shape and dynamics. The model also gave insight into the range and sensitivity required for in-flight thermal measurements and supported the development of an ABAQUS-coupled thermo-structural model. The paper also discusses three kinds of tests conducted to 1) determine the optical properties of candidate materials; 2) evaluate uncooled microbolometer-type infrared imagers; and 3) operate a prototype imager with the ODS baseline configuration. (Uncooled bolometers are less sensitive than cooled ones, but may be necessary because of restrictive ODS mass and power limits.) The team measured the spectral properties of several coated polymer samples at various angles of incidence. Two commercially available uncooled microbolometer imagers were compared, and it was found that reliable temperature measurements are feasible for both coated and uncoated sides of typical sail membrane materials.

Miles, Jonathan J.↗