Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mechanical loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of Zoledronate and Mechanical Loading during Simulated Weightlessness on Bone Structure and Mechanical Properties

Space flight modulates bone remodeling to favor bone resorption. Current countermeasures include an anti-resorptive drug class, bisphosphonates (BP), and high-force loading regimens. Does the combination of anti-resorptives and high-force exercise during weightlessness have negative effects on the mechanical and structural properties of bone? In this study, we implemented an integrated model to mimic mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hindlimb unloading (HU). Our working hypothesis is that CL combined with ZOL in the HU model induces additive structural and mechanical changes. Thirty-two C57BL6 mice (male,16 weeks old, n8group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45gkg), or saline vehicle, prior to experiment. The right tibia was axially loaded in vivo, 60xday to 9N in compression, repeated 3xweek during HU. During the application of compression, secant stiffness (SEC), a linear estimate of slope of the force displacement curve from rest (0.5N) to max load (9.0N), was calculated for each cycle once per week. Ex vivo CT was conducted on all subjects. For ex vivo mechanical properties, non-CL left femurs underwent 3-point bending. In the proximal tibial metaphysis, HU decreased, CL increased, and ZOL increased the cancellous bone volume to total volume ratio by -26, +21, and +33, respectively. Similar trends held for trabecular thickness and number. Ex vivo left femur mechanical properties revealed HU decreased stiffness (-37),and ZOL mitigated the HU stiffness losses (+78). Data on the ex vivo Ultimate Force followed similar trends. After 3 weeks, HU decreased in vivo SEC (-16). The combination of CL+HU appeared additive in bone structure and mechanical properties. However, when HU + CL + ZOL were combined, ZOL had no additional effect (p0.05) on in vivo SEC. Structural data followed this trend with ZOL not modulating trabecular thickness in CL + NAHU mice. In summary, our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. Based on these results, we conclude that, at the structural and stiffness level, zoledronate treatment during simulated spaceflight does not impede the skeletal response to axial compression. In contrast to our hypothesis, our data show that zoledronate confers no additional mechanical or structural benefit beyond those gained from cyclical loading.

Mechanical Loading↗

Elastic-Plastic Nonlinear Response of a Space Shuttle External Tank Stringer: Thermal and Mechanical Loadings - Part 2

Elastic-plastic, large-deflection nonlinear thermo-mechanical stress analyses are performed for the Space Shuttle external tank s intertank stringers. Detailed threedimensional finite element models are developed and used to investigate the stringer s elastic-plastic response for different thermal and mechanical loading events from assembly through flight. Assembly strains caused by initial installation on an intertank panel are accounted for in the analyses. Thermal loading due to tanking was determined to be the bounding loading event. The cryogenic shrinkage caused by tanking resulted in a rotation of the intertank chord flange towards the center of the intertank, which in turn loaded the intertank stringer feet. The analyses suggest that the strain levels near the first three fasteners remain sufficiently high that a failure may occur. The analyses also confirmed that the installation of radius blocks on the stringer feet ends results in an increase in the stringer capability.

Knight, Norman F., Jr.↗

A unified creep-plasticity model suitable for thermo-mechanical loading

An experimentally based unified creep-plasticity constitutive model was implemented for 1070 steel. Accurate rate and temperature effects were obtained for isothermal and thermo-mechanical loading by incorporating deformation mechanisms into the constitutive equations in a simple way.

Slavik, D.↗

Uniform Mechanical Loading Can Test for Nonuniform Loading Durability

In this work, we present a method to evaluate the equivalency between any module mechanical loading conditions. The method is developed to address the specific failure mode of glass fracture and is based on Weibull analysis and weakest link theory. It considers the varying stress profile across the module to calculate the probability of glass fracture, which is used as the metric of equivalency. An idealized nonuniform loading scheme is employed to demonstrate the method and introduce the concept of the equivalent uniform load factor: a factor applied to the maximum pressure of the nonuniform load to obtain the equivalent uniform load value. It is demonstrated that this factor is less than unity for all nonuniform load cases considered, including snow and various characters of wind loading. These significant results suggest that uniform loading may be reliably, and practically, employed to evaluate photovoltaic module glass for nonuniform loading durability.

14 SOLAR ENERGY↗

Prostaglandin E2 increases the skeletal response to mechanical loading

The study tested the influence of prostaglandin E2 (PGE2) on the skeletal response to increased in vivo mechanical loading through a four-point bending device. One hundred and twenty Sprague-Dawley female rats (6 months old, 354 +/- 34 g) were divided into 12 groups to accommodate all possible combinations of doses of loads (25, 30, or 35 N) and PGE2 (0, 0.1, 0.3, or 1 mg/kg). Rats received subcutaneous injections of PGE2 daily and in vivo loading of the right tibia every Monday, Wednesday, and Friday for four weeks. Histomorphometric analysis of the periosteal and endocortical surfaces following in vivo dual fluorochrome labeling was performed on both the loaded region of the right tibial diaphysis and a similar region of the left tibial diaphysis. Without PGE2, the threshold for loading to stimulate bone formation was 30 N (peak strain 1360 mu epsilon) at the periosteal surface and 25 N (peak strain 580 mu epsilon) at the endocortical surface. Without loading, the minimum dose of PGE2 to stimulate bone formation at all surfaces was 1 mg/kg/day. When 1 mg/kg/day PGE2 was combined with the minimum effective load, an additive effect of PGE2 and loading on bone formation was observed at the endocortical surface, but a synergistic effect was noted at the periosteal surface. No combined effect of ineffective doses of loading and PGE2 was found. A synergistic effect at peak strains of approximately 1625 mu epsilon on the periosteal surface could suggest either the involvement of locally produced growth factors or autoregulation of endogenous synthesis of PGE2 by exogenously administered PGE2.

NASA Program Space Physiology and Countermeasures↗

Closed-form analysis of fiber-matrix interface stresses under thermo-mechanical loadings

Closed form techniques for calculating fiber matrix (FM) interface stresses, using repeating square and diamond regular arrays, were presented for a unidirectional composite under thermo-mechanical loadings. An Airy's stress function micromechanics approach from the literature, developed for calculating overall composite moduli, was extended in the present study to compute FM interface stresses for a unidirectional graphite/epoxy (AS4/3501-6) composite under thermal, longitudinal, transverse, transverse shear, and longitudinal shear loadings. Comparison with finite element results indicate excellent agreement of the FM interface stresses for the square array. Under thermal and longitudinal loading, the square array has the same FM peak stresses as the diamond array. The square array predicted higher stress concentrations under transverse normal and longitudinal shear loadings than the diamond array. Under transverse shear loading, the square array had a higher stress concentration while the diamond array had a higher radial stress concentration. Stress concentration factors under transverse shear and longitudinal shear loadings were very sensitive to fiber volume fraction. The present analysis provides a simple way to calculate accurate FM interface stresses for both the square and diamond array configurations.

Naik, Rajiv A.↗

Analysis of Curved Sandwich Panels Subjected to Combined Temperature Gradient and Mechanical Loads

The results of a detailed study of the nonlinear response of curved sandwich panels with composite face sheets and subjected to a temperature gradient through-the-thickness combined with mechanical loadings are presented. The analysis is based on a first-order shear-deformation Sanders-Budiansky type theory with the effects of large displacements, moderate rotations, transverse shear deformation and laminated anisotropic material behavior included. A mixed formulation is used with the fundamental unknowns consisting of the generalized displacements and the stress resultants of the panel. The nonlinear displacements, strain energy, principal strains, transverse shear stresses, transverse shear strain energy density, and their hierarchical sensitivity coefficients are evaluated. The hierarchical sensitivity coefficients measure the sensitivity of the nonlinear response to variations in the panel parameters, the effective properties of the face sheet layers and the core, and the micromechanical parameters. Numerical results are presented for cylindrical panels subjected to combined pressure loading, edge shortening or extension, edge shear and a temperature gradient through the thickness. The results show the effects of variations in the loading and the panel aspect ratio, on the nonlinear response and its sensitivity to changes in the various panel, effective layer and micromechanical parameters.

Noor, Ahmed K.↗

Evaluation of thermal and mechanical loading effects on the structural behavior of a SiC/titanium composite

Composite specimens of titanium-15-3 matrix reinforced with continuous SCS-6 silicon carbide fibers were tested under a variety of thermal and mechanical loadings. A combined experimental/finite element approach was used to estimate the effective in-situ modulus of the matrix material and to evaluate changes in modulus due to the applied loads. Several fiber orientations were tested. Results indicate that the effect of the thermal loads on composite stiffness varies with fiber orientation. Applications of this method to test specimens damaged by uniaxial tension, thermal cycling, and isothermal fatigue loadings are used to illustrate that by monitoring overall structural behavior, changes in stiffness caused by thermomechanical loading can be detected.

Grady, Joseph E.↗

Evaluation of thermal and mechanical loading effects on the structural behavior of a SIC/titanium composite

Composite specimens of titanium-15-3 matrix reinforced with continuous SCS-6 silicon carbide fibers were tested under a variety of thermal and mechanical loadings. A combined experimental/finite element approach was used to estimate the effective in situ modulus of the matrix material and to evaluate changes in modulus due to the applied loads. Several fiber orientations were tested. Results indicate that the effect of thermal loads on composite stiffness varies with fiber orientation. Applications of this method to test specimens damaged by uniaxial tension, thermal cycling, and isothermal fatigue loadings are used to illustrate that by monitoring overall structural behavior, changes in stiffness caused by thermomechanical loading can be detected.

Grady, J. E.↗

Postbuckling of laminated flat and curved panels under combined thermal and mechanical loadings

The static postbuckling of simply-supported, symmetrically laminated composite and single-layered flat and doubly-curved shallow panels, subjected to both a stationary non-uniform temperature field and a system of mechanical loadings is investigated. A number of non-classical effects related to the transverse shear flexibility of constituent materials, the unavoidable initial geometric imperfections and the character of tangential boundary conditions are considered and pertinent conclusions about their role on the postbuckling response are emphasized. Throughout the paper the results based upon a higher-order theory are compared with their first order shear deformable and classical counterparts, and conclusions related to their range of applicability are outlined.

Librescu, L.↗

Mechanical-load indicator

By rotation of washerlike part, mechanical indicator shows when predetermined compression or tension load has been reached. Indicator consists of bolt, sleeve, load-indicating washer, and nut. Besides application as load indicator, device has uses as remote indicator of mechanical action. Rotating washer can also act as sequencer, signaling action to begin upon attainment of certain load. It can be used, for example, to initiate work cycle after stored energy has been built up in hydraulic or pneumatic power equipment. It can also be used as remote, nonelectrical switch in hazardous environments.

Appleberry, W. T.↗

Corner Wrinkling at a Square Membrane Due to Symmetric Mechanical Loads

Thin-film membrane structures are under consideration for use in many future gossamer spacecraft systems. Examples include sunshields for large aperture telescopes, solar sails, and membrane optics. The development of capabilities for testing and analyzing pre-tensioned, thin film membrane structures is an important and challenging aspect of gossamer spacecraft technology development. This paper presents results from experimental and computational studies performed to characterize the wrinkling behavior of thin-fi[m membranes under mechanical loading. The test article is a 500 mm square membrane subjected to symmetric comer loads. Data is presented for loads ranging from 0.49 N to 4.91 N. The experimental results show that as the load increases the number of wrinkles increases, while the wrinkle amplitude decreases. The computational model uses a finite element implementation of Stein-Hedgepeth membrane wrinkling theory to predict the behavior of the membrane. Comparisons were made with experimental results for the wrinkle angle and wrinkled region. There was reasonably good agreement between the measured wrinkle angle and the predicted directions of the major principle stresses. The shape of the wrinkle region predicted by the finite element model matches that observed in the experiments; however, the size of the predicted region is smaller than that determined in the experiments.

Blandino, Joseph R.↗

Cellular and molecular mechanisms for the bone response to mechanical loading

To define the cellular and molecular mechanisms for the osteogenic response of bone to increased loading, several key steps must be defined: sensing of the mechanical signal by cells in bone, transduction of the mechanical signal to a biochemical one, and transmission of that biochemical signal to effector cells. Osteocytes are likely to serve as sensors of loading, probably via interstitial fluid flow produced during loading. Evidence is presented for the role of integrins, the cell's actin cytoskeleton, G proteins, and various intracellular signaling pathways in transducing that mechanical signal to a biochemical one. Nitric oxide, prostaglandins, and insulin-like growth factors all play important roles in these pathways. There is growing evidence for modulation of these mechanotransduction steps by endocrine factors, particularly parathyroid hormone and estrogen. The efficiency of this process is also impaired in the aged animal, yet what remains undefined is at what step mechanotransduction is affected.

Review↗

Effect of Cyclic Thermo-Mechanical Loads on Fatigue Reliability in Polymer Matrix Composites

A methodology to compute probabilistic fatigue life of polymer matrix laminated composites has been developed and demonstrated. Matrix degradation effects caused by long term environmental exposure and mechanical/thermal cyclic loads are accounted for in the simulation process. A unified time-temperature-stress dependent multi-factor interaction relationship developed at NASA Lewis Research Center has been used to model the degradation/aging of material properties due to cyclic loads. The fast probability integration method is used to compute probabilistic distribution of response. Sensitivities of fatigue life reliability to uncertainties in the primitive random variables (e.g., constituent properties, fiber volume ratio, void volume ratio, ply thickness, etc.) computed and their significance in the reliability- based design for maximum life is discussed. The effect of variation in the thermal cyclic loads on the fatigue reliability for a (0/+/- 45/90)(sub s) graphite/epoxy laminate with a ply thickness of 0.127 mm, with respect to impending failure modes has been studied. The results show that, at low mechanical cyclic loads and low thermal cyclic amplitudes, fatigue life for 0.999 reliability is most sensitive to matrix compressive strength, matrix modulus, thermal expansion coefficient, and ply thickness. Whereas at high mechanical cyclic loads and high thermal cyclic amplitudes, fatigue life at 0.999 reliability is more sensitive to the shear strength of matrix, longitudinal fiber modulus, matrix modulus, and ply thickness.

Shah, A. R.↗

CDKN1A/P21’S Role in Osteoprogenitor Fate Regulation in Response to Mechanical Loading: A Single Cell Resolution Investigation

Forces generated by gravity in load-bearing tissues such as bone marrow promote stem cell-based tissue-regenerative processes by increasing proliferation and differentiation of tissue progenitors. Conversely, in microgravity, mouse bone marrow mesenchymal and hematopoietic precursors down-regulate differentiation markers and up-regulate stemness maintenance genes. During microgravity, these transcriptomic changes are associated with Cdkn1a overexpression in osteoprogenitors, and further the homozygous deletion of the CDKN1a gene in the mouse model results in elevated stem-cell based regeneration of severed digits and ear-hole punches. In this work we sought to test the hypothesis that gravity mechanotransduction regulates mesenchymal stem cell derived osteoprogenitor based osteogenesis by modulating proliferation and differentiation fates at specific cell cycle stages via a p21/CDKN1a-regulated mechanism.. To test our hypothesis, we isolated primary mouse bone marrow osteoprogenitors from Cdkn1a-/- (null) or wildtype mice, cultured the cells for 7-days unloaded in osteogenic differentiation media, to allow commitment of the adherent cell population, and subsequently, cultured an additional 48-hours under cyclic stretch or static control loading conditions. After 48-hours of dynamic mechanical loading, we used a 10X Genomics Chromium/Single Cell controller to generate bar-coded single cell Illumina libraries and sequenced expressomes for 6,000 static control and 6,000 cyclic stretch cells for each genotype. Stage-specific single cell analyses show Cdkn1a-/- osteogenic cultures are more differentiated with fewer progenitors, and that cyclic stretch further promotes the conversion of progenitors to osteoblasts in both wildtype and Cdkn1a-/- backgrounds. The proportion of late mineralizing osteoblasts doubled in Cdkn1a-/- cultures, but is not affected by load. Finally, single cell expression of Cdkn1a, in the wildtype cells, is most strongly suppressed by cyclic stretch both in early and late osteoblasts, and minimally in the progenitor population. Collectively, our results support the hypothesis that Cdkn1a constitutively plays a mechano-reversible anti-proliferative role during stem cell-based bone tissue regeneration, and suggests a new molecular target to counter regenerative deficits caused by disuse.

Eduardo Almeida↗

Effects of Stiffening and Mechanical Load on Thermal Buckling of Stiffened Cylindrical Shells

A study of thermal buckling of stiffened cylindrical shells with the proportions of a preliminary supersonic transport fuselage design (1970) is presented. The buckling analysis is performed using an axisymmetric shell-of-revolution code, BOSOR4. The effects of combined mechanical (axial loading) and thermal loading (heated skins) are investigated. Results indicate that the location of longitudinal eccentric stiffening has a very large effect on the thermal buckling strength of longitudinally stiffened shells, and on longitudinally stiffened shells with rings.

Johnson, Theodore F.↗

Combined mechanical loading of composite tubes

An analytical/experimental investigation was performed to study the effect of material nonlinearities on the response of composite tubes subjected to combined axial and torsional loading. The effect of residual stresses on subsequent mechanical response was included in the investigation. Experiments were performed on P75/934 graphite-epoxy tubes with a stacking sequence of (15/0/ + or - 10/0/ -15), using pure torsion and combined axial/torsional loading. In the presence of residual stresses, the analytical model predicted a reduction in the initial shear modulus. Experimentally, coupling between axial loading and shear strain was observed in laminated tubes under combined loading. The phenomenon was predicted by the nonlinear analytical model. The experimentally observed linear limit of the global shear response was found to correspond to the analytically predicted first ply failure. Further, the failure of the tubes was found to be path dependent above a critical load level.

Derstine, Mark S.↗

Zoledronate Prevents Simulated Weightlessness-Induced Bone Loss in the Cancellous Compartment While Blunting the Efficacy of a Mechanical Loading Countermeasure

Astronauts using high-force resistance training while weightless show a high-turnover remodeling state within the skeletal system, with resorption and formation biomarkers being elevated. One countermeasure for the skeletal health of astronauts includes an antiresorptive of the bisphosphonate (BP) drug class. We asked, does the combination of an anti-resorptive and high-force exercise during weightlessness have negative effects on bone remodeling and strength? In this study, we developed an integrated model to mimic the mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hind limb unloading (HU) to simulate weightlessness. We hypothesized that ZOL prevents structural degradation from simulated weightlessness and that CL and ZOL interact to render CL less effective. Thirty-two C57BL/6 mice (male, 16 weeks old, n=8/group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45μg/kg), or saline vehicle (VEH), prior to the start of HU. The right tibia was axially compressed in vivo 60x/day to 9N (+1200μstrain on the periosteal surface) and repeated 3x/week during HU. Left tibiae served as a within subject, non-compressed control. Ex vivo μCT was performed on all subjects to determine cancellous and cortical architectural parameters. Static and dynamic histomorphometry were carried out for the left and right tibiae to determine osteoclast- and osteoblast relevant surfaces. Further, micro damage was assessed in select groups by basic-fuchsin staining to test whether CL had an effect. For all assays, a multivariate (2x2x2) ANCOVA model was used to account for body weight changes. Additionally, for the tibiae, we incorporated a random effect for the subject (hence, a mixed model) to account for observations of both left and right tibiae within each subject. P < 0.05 was considered significant. In the cancellous compartment of the proximal tibial metaphysis, we observed a main effect from each independent variable, as determined by structural and histomorphometric assays. Specifically, as expected, ZOL showed an increase in the cancellous bone volume to total volume fraction (BV/TV, +32%) and trabecular number (+18%) compared to the VEH. As expected, ZOL decreased osteoclast surface (OC/BS) by -45% compared to VEH. Surprisingly, ZOL reduced mineralizing surface (MS/BS) and bone formation rate (BFR), indicators of osteoblast activity, by -40% and -54%, respectively, compared to VEH. Altogether, ZOL-treated mice displayed a low turnover state of remodeling in the metaphysis. In the context of skeletal aging, we speculate that ZOL prevented age-related cancellous strut loss during the experiment. As a main effect, as expected, HU decreased BV/TV by - 31% via reductions in both trabecular thickness (-11%) and number (-22%) compared to NA controls. Additionally, HU decreased MS/BS by -38% and bone formation rate (BFR) by -50% compared to NA controls. Altogether, these data are consistent with structural degradation resulting from imbalanced remodeling that favors resorption. As a main effect, CL increased BV/TV by +15% via increased trabecular thickness (+12%) compared to the noncompressed limb. As expected, CL increased MS/BS (+20%) and BFR (+24%), indicating osteoblast mineralization contributed to bone gains. These data show that CL provided an anabolic stimulus to the cancellous tissue. We observed unique interactions in ZOL*CL and HU*CL. First, ZOL prevented CL-induced increases in BV/TV and trabecular number, as compared to VEH. In the context of skeletal aging, these data suggest no added benefit from CL in the ZOL-treated mice. Interestingly, no microdamage was observed in mice that were unloaded and treated with ZOL (independent of CL). Secondly, HU prevented CL-induced increases in BFR, as compared to NA controls. These data suggest that either exercise is less effective or the kinetics of formation are slower during simulated weightlessness. Osteoclast surface was unchanged by either treatment. Thus, in contrast to exercising astronauts, these data do not suggest a high-turnover state in the metaphysis. To assess mechanical properties as a function of HU or ZOL, we tested the left femur in three-point bending ex vivo. As expected, HU decreased stiffness (-30%) compared to NA, and ZOL increased stiffness compared to VEH (+28%). Interestingly, HU increased the post-yield displacement, related to collagenous tensile loading, compared to NA (+20%). ZOL increased yield force (+11%) and ultimate force (+17%), which seems to explain the significant effect of ZOL increasing total energy (work-to-fracture, +15%), while not affecting the post yield displacement. Taken together, ZOL did not have detrimental affect on mechanical properties. Our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. We conclude that Zoledronate was an effective countermeasure against weightlessness-induced bone loss, though zoledronate, as well as weightlessness, rendered exercise-related mechanical loading less effective.

bone↗