Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Materials Compatibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Materials Compatibility in High Test Hydrogen Peroxide

Previous ratings of the compatibility of high test hydrogen peroxide (HTP) with materials are not adequate for current needs. The goal of this work was to develop a new scheme of evaluation of compatibility of HTP with various materials. Procedures were developed to enrich commercially available hydrogen peroxide to 90% concentration and to assay the product. Reactivity testing, accelerated aging of materials and calorimetry studies were done on HTP with representative metallic and non-metallic materials. It was found that accelerated aging followed by concentration determination using refractive index effectively discriminated between different Class 2 metallic materials. Preliminary experiments using Differential Scanning Calorimetry (DSC) suggest that a calorimetry experiment is the most sensitive means to assay the compatibility of HTP with materials.

Gostowski, Rudy↗

Space Suit Material Compatibility with Space Vehicle Coolant PMS-1.5R

During a survey of 82P on February 11, 2023, a shiny substance was detected on the Progress vehicle. The suspected material was PMS-1.5R, a low volatility silicone oil coolant used in the vehicle. Crew exposure to the coolant was a concern as the low volatility would increase residence time, the time a material will stay on a surface after exposure to vacuum. A review of space suit materials revealed several materials with compatibility concerns that could impact Extravehicular Activity (EVA) operations and safety. To understand the risk, space suit materials were exposed to a simulant and tested. This testing provided the basis for rationale generated to continue with EVA operations for US EVA 86 on April 2, 2023. This testing also served as the basis to assess impacts to ISS EMU hardware due to potential contamination brought inside ISS on Russian space suits during RS EVA 61 on October 25, 2023, following an ISS Russian Multipurpose Lab Module (MLM) radiator leak of the same fluid on October 9, 2023. This paper will discuss the testing performed and analyze test results impacts to EVA operations. Additional work was conducted to determine coolant evaporation rates in space vacuum and demonstrate that no significant unreacted coolant from the MLM leak would remain on ISS surfaces long enough to contaminate the EMU or affect the ISS ECLSS water separator.

Space Suit Materials↗

NASA Engineering and Safety Center Technical Bulletin No. 20-06: Material Compatibility Assessment of Spacecraft Oxidizer Systems

Recently designed oxidizer systems used in spacecraft propulsion are pushing the limits of materials and operating conditions. As a result, nitrogen tetroxide (NTO) oxidizer systems are exhibiting failures driven by ignition mechanisms similar to oxygen systems. Oxidizer systems (e.g., O 2 , N 2 O 4 , N 2 O H 2 O 2 ) have generally been designed and operated within industry experience for material corrosion concerns without a complete understanding or regard for the concerns regarding potential material ignition and burning. To compound the problem, the effects of varying parameters on ignition and the kindling chain have not been studied, and there is a very limited amount of published data to help with the understanding. NASA-sponsored testing is actively researching ignition mechanisms, determining thresholds, and defining operating envelopes to inform the aerospace community.

NESC↗

Seal Materials Compatible with the Electroplating Solvent Used in Constellation-X Mirrors

The existing gasket seals used in electroplating of the Constellation-X mirrors are difficult to assemble, and the current seal material is hydrophobic and too thick. The combination of the above problems result in: 1) non-uniform plating; 2) defect sites such as pits on the mirror edges; 3) "bear claws" on the edges of the mandrels and mirrors causing difficulties in shell-mirror separations; and 4) leakage of the plating solution past the seals into the mandrel causing chemical etching of the mandrel interior. This paper reports the results of this summer study in searching for alternate seal materials chemically compatible with the electroplating solvent. Fifteen common elastomeric rubber seal materials made-by Parker Seals were investigated including butyl, ethylene propylene, fluorosilicone, nitrile, Viton fluorocarbon, and silicone. Test results showed that Viton fluorocarbon compounds as a group were superior to the other tested compounds for chemical compatibility with the plating bath.

Pei, Xiong-Skiba↗

Material compatibility with gaseous fluorine

Static tests on the compatibility of fluorine with non-metals at atmospheric temperature eliminated many materials from further consideration for use in fluorine systems. Several materials were found compatible at atmospheric pressures. Only Teflon and ruby (aluminum oxide) were compatible at 1500 pounds per square inch gage.

Price, Harold G , Jr↗

Further Studies of Materials Compatibility in High-Test Hydrogen Peroxide

Assessment of the compatibility of high-test hydrogen peroxide (HTP) with materials, in particular new materials such as composites, is critical to the development of new propulsion systems meeting requirements of reduced cost and environmental impact. While compatibility with HTP has been addressed previously, newer materials were not considered. The focus of this project was to develop a scheme for evaluation of HTP with all materials. In the previous summer, methods were developed for production of HTP on site, and preliminary steps were taken to evaluate materials. Methods investigated this summer have included accelerated aging by heating, coupled with assay of concentration and stabilization loss, observation of reactivity by means of Isothermal Microcalorimetry, and evaluation of changes to the materials by Short Beam Shear testing and by Photoacoustic-Fourier Transform Infrared Spectroscopy. Various metals, polymers, and composites were examined in this study.

Gostowski, R.↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

Electrochemical, Polarization, and Crevice Corrosion Testing of Inconel X750: A Supplement to the Environmental Control and Life Support System Sustaining Metal Materials Compatibility Study

In previous studies, electrochemical test results were experimentally acquired and then presented for several noble alloys in two specific solutions representative of waste liquids generated or present within the Environmental Control and Life Support System (ECLSS) aboard the International Space Station (ISS). Subsequently, another metal candidate, Inconel X750, has been submitted and was subjected to the same test routines in the same solutions and evaluated with the same statistical/analytical methodologies as those utilized in the earlier studies. Previous studies included three titanium grades, (Commercially Pure, 6Al-4V alloy, and 6Al-4V Low Interstitial alloy), two nickel-chromium alloys (Inconel® 625 and Hastelloy® C276), one high tier stainless steel (Cronidur® 30), and a nickel-titanium alloy (Nitinol 60). Thus far, all candidate alloys have exhibited excellent corrosion protection and galvanic compatibility attributes and have been deemed qualified materials for application within the ECLSS facility. Inconel X750 now joins that group. The titanium alloys gave the best results of all the metal candidates by demonstrating superior nobility and galvanic protection properties. It is worth noting that the corrosion performance properties for the three titanium alloys were essentially indistinguishable. As such and for expediency, this study and all future evaluations will refer only to the comparative properties already documented for Titanium 6Al-4V as this alloy is representative of all three alloys and considered to be more mainstream. Now the measured corrosion properties for Inconel X750 were very similar to those determined previously for Inconel 625 and Hastelloy C276 which were also determined to be very high performers. For the current effort, the results have clearly shown that Inconel X750 possesses exceptional anti-corrosion attributes comparable to metals in the highest tier of the galvanic series. Overall, one can conclude that Inconel X750 is quite noble, highly corrosion resistant and galvanically compatible with the other metal groups from both an electrochemical perspective and a long-term exposure scenario. This was clearly demonstrated after utilizing the same techniques as those applied in previous studies which included linear, Tafel and cyclic polarization, galvanic coupling with each of the other metal candidates, and pitting/crevicing assessments after one full year of immersion in the subject test solutions. Attributes defining the nobility and anti-corrosion capabilities for X750 appear to be on par with all the other candidates thus far and this alloy can now be classified as ‘excellent’ exhibiting very high resistance toward general, localized, and galvanic corrosion in the subject test media.

Lee, R. E.↗

Nonmetallic Material Compatibility with Liquid Fluorine

Static tests were made on the compatibility of liquid fluorine with several nonmetallic materials at -3200 F and at pressures of 0 and 1500 pounds per square inch gage. The results are compared with those from previous work with gaseous fluorine at the same pressures, but at atmospheric temperature. In general, although environmental effects were not always consistent, reactivity was least with the low-temperature, low-pressure liquid fluorine. Reactivity was greatest with the warm, high-pressure gaseous fluorine. None of the liquids and greases tested was found to be entirely suitable for use in fluorine systems. Polytrifluorochloroethylene and N-43, the formula for which is (C4F9)3N, did not react with liquid fluorine at atmospheric pressure or 1500 pounds per square inch gage under static conditions, but they did react when injected into liquid fluorine at 1500 pounds per square inch gage; they also reacted with gaseous fluorine at 1500 pounds per square inch gage. While water did not react with liquid fluorine at 1500 pounds per square inch gage, it is known to react violently with fluorine under other conditions. The pipe-thread lubricant Q-Seal did not react with liquid fluorine, but did react with gaseous fluorine at 1500 pounds per square inch gage. Of the solids, ruby (Al2O3) and Teflon did not react under the test conditions. The results show that the compatibility of fluorine with nonmetals depends on the state of the fluorine and the system design.

Price, Harold G , Jr↗

Long-term material compatibility testing system

System includes procedure for hermetically sealing solid materials and fluids in glass ampoule and use of temperature-controlled facility containing sample holder, which permits sample containers to be retrieved safely and conveniently. Solid material and fluid are sealed within chemically-clean glass ampoule according to highly detailed procedure.

Toth, L. R.↗

Materials compatibility with oxidizer-rich gases at elevated temperatures and pressure

An investigation of oxygen compatibility and resistance to ignition of candidate materials for use in a liquid rocket engine designed to incorporate an oxidizer rich preburner-LOX turbopump configuration was discussed. The program was divided into two basic tasks. The first task was to develop a preliminary design of an oxidizer turbopump preburner section complete with thermal and MS Parameter analyses and to develop a conceptual design of the main injector with a preliminary engine specification as the final product. The second task was directed totally at testing materials in oxygen-rich environments.

Source record↗

Channel multiplier compatible materials and lifetime tests

Certain materials useful in space sensor construction were tested for their noncontaminating compatibility with channel electron multipliers. Gain profiles indicate that the materials tested do not adversely affect the lifetimes of the multipliers. These materials are, therefore, shown to be safe for use with channel electron multipliers in space instrumentation even for the most stringent long lifetime mission requirements. The tests indicate that the multipliers which are to be flown on an extended space mission will have adequate lifetimes to return satisfactory data throughout the entire mission.

Mccomas, D. J.↗

Materials Compatibility Testing in RSRM ODC: Free Cleaner Selection

Government regulations have mandated production phase-outs of a number of solvents, including 1,1,1-trichloroethane, an ozone-depleting chemical (ODC). This solvent was used extensively in the production of the Reusable Solid Rocket Motors (RSRMs) for the Space Shuttle. Many tests have been performed to identify replacement cleaners. One major area of concern in the selection of a new cleaner has been compatibility. Some specific areas considered included cleaner compatibility with non-metallic surfaces, painted surfaces, support materials such as gloves and wipers as well as corrosive properties of the cleaners on the alloys used on these motors. The intent of this paper is to summarize the test logic, methodology, and results acquired from testing the many cleaner and material combinations.

Keen, Jill M.↗

Material compatibility evaluation for liquid oxygen turbopump fluid foil bearings

Three series of tests were carried out on three polymer-coated Inconel substrate materials, Teflon S, polyimide bonded graphite fluoride (PBGF), and Teflon, which are considered for use in fluid foil bearings for a liquid oxygen turbopump. All the candidate materials passed the liquid oxygen frictional heating test. During the gaseous oxygen frictional heating test, all coatings wore off before ignition occured. Both Teflon S and PBGF coated foils passed 100 start/stop cycles against chrome-plated Inconel 718 shaft in the direct foil bearing lift-off simulation test in liquid oxygen.

Stoltzfus, J. M.↗