Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Survey and Experimental Testing of Nongravimetric Mass Measurement Devices

Documentation presented describes the design, testing, and evaluation of an accelerated gravimetric balance, a low mass air bearing oscillator of the spring-mass type, and a centrifugal device for liquid mass measurement. A direct mass readout method was developed to replace the oscillation period readout method which required manual calculations to determine mass. A protoype 25 gram capacity micro mass measurement device was developed and tested.

Oakey, W. E.↗

24.1.3.4 Upgraded Fixed Energy Response Function Analysis with Multiple Efficiencies (FRAM) Software for U/Pu/MOX Mass Measurements

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr 3 ) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold gas mass measurements for the era of large optical spectroscopic surveys

ABSTRACT Gas plays an important role in many processes in galaxy formation and evolution, but quantifying the importance of gas has been hindered by the challenge to measure gas masses for large samples of galaxies. Data sets of direct atomic and molecular gas measurements are sufficient to establish simple scaling relations, but often not large enough to quantify three-parameter relations, or second-order dependences. As an alternative approach, we derive here indirect cold gas measurements from optical emission lines using photoionization models for galaxies in the Sloan Digital Sky Survey (SDSS) main galaxy sample and the PHANGS-MUSE survey. We calibrate the gas surface density measurements using xCOLD GASS and PHANGS-ALMA molecular gas measurements to ensure that our measurements are reliable. We demonstrate the importance of taking into account the scale dependence of the relation between optical depth (τ V ) and gas surface density (Σ gas ) and provide a general prescription to estimate Σ gas from τ V , metallicity, and the dust-to-metal ratio, at any arbitrary physical resolution. To demonstrate that the indirect cold gas masses are accurate enough to quantify the role of gas in galaxy evolution, we study the mass–metallicity relation of SDSS galaxies and show that as a third parameter gas mass is better than star formation rate at reducing the scatter of the relation, as predicted by models and simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the effects of precise mass measurements of Ru and Pd isotopes on machine learning mass modeling

Atomic masses are a foundational quantity in our understanding of nuclear structure, astrophysics, and fundamental symmetries. The longstanding goal of creating a predictive global model for the binding energy of a nucleus remains a significant challenge, however, and prompts the need for precise measurements of atomic masses to serve as anchor points for model developments. We present precise mass measurements of neutron-rich Ru and Pd isotopes performed at the Californium Rare Isotope Breeder Upgrade facility at Argonne National Laboratory using the Canadian Penning Trap mass spectrometer. The masses of 108 Ru, 110 Ru, and 116 Pd were measured to a relative mass precision $\delta$⁢$m/m$ ≈ 10 -8 via the phase-imaging ion-cyclotron-resonance technique, and represent an improvement of approximately an order of magnitude over previous measurements. Further, these mass data were used in conjunction with the physically interpretable machine learning (PIML) model, which uses a mixture density neural network to model mass excesses via a mixture of Gaussian distributions. The effects of our new mass data on a Bayesian-updating of a PIML model are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of Polaron Formation in Halide Perovskites via Carrier Effective Mass Measurements

Carrier effective mass is a central parameter in solid-state physics. It is a measure of the strength of the coupling between a carrier and excitations arising from its surrounding medium, and features prominently in transport and optical calculations. Experimental techniques employed to determine it are steady-state ones, and so are unable to detect any change in the effective mass after a strong perturbation to the system, e.g., strong optical excitation. By combining time-resolved terahertz spectroscopy and transient absorption spectroscopy, on a mixed-cation mixed-halide perovskite thin film, we observe a large and long-lived photoinduced enhancement of the carrier effective mass, and from it deduce a twofold increase of the carrier-phonon coupling constant, giving evidence of polaron formation. Our work demonstrates a new approach to track the strength and ultrafast lifetimes of photoinduced carrier-boson interactions down to picosecond timescales that can be applied to a wide range of solid-state systems.

36 MATERIALS SCIENCE↗

Gravitational gradiometer measures mass changes

Differential angular accelerometer, utilizing complex geometric configurations and spring-coupled rotating masses, demonstrates feasibility of measuring mass distributions of celestial bodies by detecting spatial gradients of their fields from orbiting vehicles. Applications include mineralogical surveying, geodetic engineering, and solar system investigation.

Bell, C. C.↗

First Penning trap mass measurement of 36 Ca

Background: Isobaric quintets provide the best test of the isobaric multiplet mass equation (IMME) and can uniquely identify higher order corrections suggestive of isospin symmetry breaking effects in the nuclear Hamilto nian. The Generalized IMME (GIMME) is a novel microscopic interaction theory that predicts an extension to the quadratic form of the IMME. Only the A = 20, 32 T = 2 quintets have the exotic T z = –2 member ground state mass determined to high-precision by Penning trap mass spectrometry. Purpose: To establish A = 36 as the third high-precision T = 2 isobaric quintet with the T z = –2 member ground state mass measured by Penning trap mass spectrometry and provide the first test of the predictive power of the GIMME. Method: Here, a radioactive beam of neutron-deficient 36 Ca was produced by projectile fragmentation at the National Superconducting Cyclotron Laboratory. The beam was thermalized and the mass of 36 Ca + and 36 Ca 2+ measured by the Time of Flight - Ion Cyclotron Resonance method in the LEBIT 9.4 T Penning trap. Results: We measure the mass excess of 36 Ca to be ME= –6483.6(56) keV, an improvement in precision by a factor of 6 over the literature value. The new datum is considered together with evaluated nuclear data on the A = 36, T = 2 quintet. We find agreement with the quadratic form of the IMME given by isospin symmetry, but only coarse qualitative agreement with predictions of the GIMME. Conclusion: A total of three isobaric quintets have their most exotic members measured by Penning trap mass spectrometry. The GIMME predictions in the T = 2 quintet appear to break down for A = 32 and greater.

20 ≤ A ≤ 38↗

Precision Mass Measurement of the Proton Dripline Halo Candidate 22 Al

Here, we report the first mass measurement of the proton-halo candidate 22 Al performed with the low energy beam ion trap facility’s 9.4 T Penning trap mass spectrometer at facility for rare isotope beams. This measurement completes the mass information for the lightest remaining proton-dripline nucleus achievable with Penning traps. 22 Al has been the subject of recent interest regarding a possible halo structure from the observation of an exceptionally large isospin asymmetry [J. Lee et al ., Large isospin asymmetry in Si22/O22 Mirror Gamow-Teller transitions reveals the halo structure of 22 Al , Phys. Rev. Lett. 125, 192503 (2020).]. The measured mass excess value of ME=18 092.5⁢(3) keV, corresponding to an exceptionally small proton separation energy of 𝑆𝑝=100.4⁢(8) keV, is compatible with the suggested halo structure. Our result agrees well with predictions from 𝑠⁢𝑑-shell USD Hamiltonians. While USD Hamiltonians predict deformation in the 22 Al ground state with minimal 1⁢𝑠 1/2 occupation in the proton shell, a particle-plus-rotor model in the continuum suggests that a proton halo could form at large quadrupole deformation. These results emphasize the need for a charge radius measurement to conclusively determine the halo nature.

binding energy↗

Mass measurements of neutron-rich gallium isotopes refine production of nuclei of the first r -process abundance peak in neutron-star merger calculations

We report mass measurements of neutron-rich Ga isotopes 80–85 Ga with TRIUMF's Ion Trap for Atomic and Nuclear science. The measurements determine the masses of 80–83 Ga in good agreement with previous measurements. Here, the masses of 84 Ga and 85 Ga were measured for the first time. Uncertainties between 25 and 48 keV were reached. The new mass values reduce the nuclear uncertainties associated with the production of A ≈ 84 isotopes by the r-process for astrophysical conditions that might be consistent with a binary neutron star (BNS) merger producing a blue kilonova. Our nucleosynthesis simulations confirm that BNS merger may contribute to the first abundance peak under moderate neutron-rich conditions with electron fractions Y e = 0.35–0.38.

59 ≤ A ≤ 89↗

OGLE-2012-bLG-0950Lb: the First Planet Mass Measurement From Only Microlens Parallax and Lens Flux

We report the discovery of a microlensing planet OGLE-2012-BLG-0950Lb with a planet/host mass ratio Periapsis Approx. = 2 x10(exp. -4). A long term distortion detected in both MOA and OGLE light curve can be explained by themicrolens parallax due to the Earths orbital motion around the Sun. Although the finite source effect is not detected, we obtain the lens flux by the high resolution Keck AO observation. Combining the microlens parallax and the lens flux reveal the nature of the lens: a planet with mass of M(sub p) = 35(+17/-)M compared to Earth is orbiting around an M-dwarf with mass of M(sub host) = 0.56(+0.12/-0.16) M compared to the Sun with a planet-host projected separation of r1 = 2.7(+0.6/-0.7) au located at Luminosity Distance = 3.0(+0.8/-1.1) kpc from us. This is the first mass measurement from only microlens parallax and the lens flux without the finite source effect. In the coming space observation-era with Spitzer, K2, Euclid, and WFIRST, we expect many such events for which we will not be able to measure any finite source effect. This work demonstrates an ability of mass measurements in such events.

microlens parallax↗

High-precision mass measurements of the isomeric and ground states of 44 V: Improving constraints on the isobaric multiplet mass equation parameters of the A=44, 0 + quintet

Background: The quadratic isobaric multiplet mass equation (IMME) has been very successful at predicting the masses of isobaric analog states in the same multiplet, while its coefficients are known to follow specific trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] 44 V mass value results in an anomalous negative c coefficient for the IMME quadratic term; a consequence of large uncertainty and an unresolved isomeric state. The b and c coefficients can provide useful constraints for construction of the isospin-nonconserving Hamiltonians for the pf shell. In addition, the excitation energy of the 0 + , T = 2 level in 44 V is currently unknown. This state can be used to constrain the mass of the more exotic 44 Cr. Purpose: The aim of the experimental campaign was to perform high-precision mass measurements to resolve the difference between 44 V isomeric and ground states, to test the IMME using the new ground state mass value and to provide necessary ingredients for the future identification of the 0 + , T = 2 state in 44 V. Method: High-precision Penning trap mass spectrometry was performed at LEBIT, located at the National Superconducting Cyclotron Laboratory, to measure the cyclotron frequency ratios of [ 44g,m VO] + versus [ 32 SCO] + , a well-known reference mass, to extract both the isomeric and ground state masses of 44 V. Results: The mass excess of the ground and isomeric states in 44 V were measured to be -23 804.9(80) keV/c 2 and -23 537.0(55) keV/c 2 , respectively. This yielded a new proton separation energy of S p = 1 773(10) keV. Conclusion: The new values of the ground state and isomeric state masses of 44 V have been used to deduce the IMME b and c coefficients of the lowest 2 + and 6 + triplets in A = 44. The 2 + c coefficient is now verified with the IMME trend for lowest multiplets and is in good agreement with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between 44 V and 44 Sc, in line with isospin-symmetry for this multiplet. Finally, the new value of the proton separation energy determined, to an uncertainty of 10 keV, will be important for the determination of the 0 + , T = 2 state in 44 V and, consequently, for prediction of the mass excess of 44 Cr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamic Modeling Accuracy Dependence on Errors in Sensor Measurements, Mass Properties, and Aircraft Geometry

A nonlinear simulation of the NASA Generic Transport Model was used to investigate the effects of errors in sensor measurements, mass properties, and aircraft geometry on the accuracy of dynamic models identified from flight data. Measurements from a typical system identification maneuver were systematically and progressively deteriorated and then used to estimate stability and control derivatives within a Monte Carlo analysis. Based on the results, recommendations were provided for maximum allowable errors in sensor measurements, mass properties, and aircraft geometry to achieve desired levels of dynamic modeling accuracy. Results using other flight conditions, parameter estimation methods, and a full-scale F-16 nonlinear aircraft simulation were compared with these recommendations.

Grauer, Jared A.↗

Dependence of Dynamic Modeling Accuracy on Sensor Measurements, Mass Properties, and Aircraft Geometry

The NASA Generic Transport Model (GTM) nonlinear simulation was used to investigate the effects of errors in sensor measurements, mass properties, and aircraft geometry on the accuracy of identified parameters in mathematical models describing the flight dynamics and determined from flight data. Measurements from a typical flight condition and system identification maneuver were systematically and progressively deteriorated by introducing noise, resolution errors, and bias errors. The data were then used to estimate nondimensional stability and control derivatives within a Monte Carlo simulation. Based on these results, recommendations are provided for maximum allowable errors in sensor measurements, mass properties, and aircraft geometry to achieve desired levels of dynamic modeling accuracy. Results using additional flight conditions and parameter estimation methods, as well as a nonlinear flight simulation of the General Dynamics F-16 aircraft, were compared with these recommendations

Grauer, Jared A.↗

resbos2 and the CDF W mass measurement

The recent collider detector at fermilab (CDF) W mass measurement of 80 , 433 ± 9 MeV is the most precise direct measurement. However, this result deviates from the Standard Model predicted mass of 80 , 359.1 ± 5.2 MeV by 7 σ . The CDF experiment used an older version of the esos code that was only accurate at NNLL + NLO , while the esos2 code is able to make predictions at N 3 LL + NNLO accuracy. We determine that the data-driven techniques used by CDF capture most of the higher order corrections, and using higher order corrections would have an impact on the CDF result in total at the 10 MeV level. Additionally, we investigate the effects from handling the width of the W boson on the mass, PDF correlations, and scale uncertainties. We find that these contributions are consistent with those obtained by CDF. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved high-precision mass measurements of mid-shell neon isotopes

New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24-26 Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N = 14mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N = 20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Damage detection using experimentally measured mass and stiffness matrices

A method is presented for locating physical damage or change in a structure using experimentally measured mass and stiffness matrices. The approach uses a recently developed algorithm for transforming a state-space realization into a second order structural model with physical displacements as the generalized coordinates. This is accomplished by first rotating a state-space model of the identified structural dynamics into modal coordinates and approximating the mass normalized modal vectors for the output measurement set. Next, the physical mass, damping and stiffness matrices are synthesized directly from the measured modal parameters. This yields experimental mass and stiffness matrices for the structure without the use of a finite element model or a numerical search. The computed mass and stiffness are asymptotically equivalent to a static condensation of the global physical coordinate model. Techniques for solving the inverse connectivity problem are then developed whereby it is possible to assess the stiffness in a region of the structure bounded by several sensors. Applications to both simulated data and experimental data are used to discuss the effectiveness of the approach.

Peterson, L. D.↗

Proposal for an astronaut mass measurement device for the Space Shuttle

For medical reasons, astronauts in space need to have their mass measured. Currently, this measurement is performed using a mass-spring system. The current system is large, inaccurate, and uncomfortable for the astronauts. NASA is looking for new, different, and preferably better ways to perform this measurement process. After careful analysis our design team decided on a linear acceleration process. Within the process, four possible concept variants are put forth. Among these four variants, one is suggested over the others. The variant suggested is that of a motor-winch system to linearly accelerate the astronaut. From acceleration and force measurements of the process combined Newton's second law, the mass of an astronaut can be calculated.

Beyer, Neil↗