Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mask”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Computing Challenges in Coded Mask Imaging

This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

Skinner, Gerald↗

Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding

Advanced formation flying occulter designs utilize a large occulter mask flying in formation with an imaging telescope to block and null starlight to allow imaging of faint planets in exosolar systems. A paper describes the utilization of subscale reflective occultation masks to evaluate formation flying occulter designs. The use of a reflective mask allows mounting of the occulter by conventional means and simplifies the test configuration. The innovation alters the test set-up to allow mounting of the mask using standard techniques to eliminate the problems associated with a standard configuration. The modified configuration uses a reflective set-up whereby the star simulator reflects off of a reflective occulting mask and into an evaluation telescope. Since the mask is sized to capture all rays required for the imaging test, it can be mounted directly to a supporting fixture without interfering with the beam. Functionally, the reflective occultation mask reflects light from the star simulator instead of transmitting it, with a highly absorptive carbon nanotube layer simulating the occulter blocking mask. A subscale telescope images the star source and companion dim source that represents a planet. The primary advantage of this is that the occulter can be mounted conventionally instead of using diffractive wires or magnetic levitation.

Hagopian, John↗

Development of an Operational Land Water Mask for MODIS Collection 6, and Influence on Downstream Data Products

Data from the Moderate Resolution Imaging Spectro-radiometer (MODIS)on-board the Earth Observing System Terra and Aqua satellites are processed using a land water mask to determine when an algorithm no longer needs to be run or when an algorithm needs to follow a different pathway. Entering the fourth reprocessing (Collection 6 (C6)) the MODIS team replaced the 1 km water mask with a 500 m water mask for improved representation of the continental surfaces. The new water mask represents more small water bodies for an overall increase in water surface from 1 to 2 of the continental surface. While this is still a small fraction of the overall global surface area the increase is more dramatic in certain areas such as the Arctic and Boreal regions where there are dramatic increases in water surface area in the new mask. MODIS products generated by the on-going C6 reprocessing using the new land water mask show significant impact in areas with high concentrations of change in the land water mask. Here differences between the Collection 5 (C5) and C6 water masks and the impact of these differences on the MOD04 aerosol product and the MOD11 land surface temperature product are shown.

Carroll, M. L.↗

Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed: Monochromatic Laboratory Demonstration for the Roman Coronagraph Instrument

The Astro2020 decadal survey recommended a direct imaging flagship mission with a goal for mission yield of 25 or more potentially habitable exoplanets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased coronagraphic instrument efficiency. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage can be suppressed. Multi-Star Wavefront Control (MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems. We present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI) and is outfitted with a MSWC mask with the same design as the contributed mask for the Roman CGI. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source for a geometry matching potential Alpha Centauri observations. Technical Review Abstract: The Astro2020 decadal survey recommended a direct imaging flagship mission with a goal for mission yield of 25 or more potentially habitable exoplanets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased coronagraphic instrument efficiency by increasing the available science target pool of bright nearby stars. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage can be suppressed. Multi-Star Wavefront Control (MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems . We present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL during the completed first vacuum window and recent results from the ongoing second vacuum window. The MSWC mask consists of a shaped pupil mask similar to the one used for the Wide-Field of View mode but also includes a set of superimposed, regularly-spaced dots that serve as a diffraction grating. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI) and is configured with a binary imaging mode with a MSWC mask using same design as the contributed mask for the Roman CGI. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source. We present results obtained in Super-Nyquist regime demonstrating suppression in the Super-Nyquist regime for the 3rd diffraction order reaching 8.7e-9 contrast with the Roman pupil. In addition, we present results obtained with the binary-star regime demonstrating 9.6e-8 contrast for a geometry matching potential Alpha Centauri observations in a monochromatic wavelength similar to Band 1. Planned demonstrations in the 2nd vacuum window will focus on Band 3d and Band 4 using the full MSWC mode for an Alpha Centauri geometry.

High-contrast imaging↗

Design criteria for small coded aperture masks in gamma-ray astronomy

Most theoretical work on coded aperture masks in X-ray and low-energy gamma-ray astronomy has concentrated on masks with large numbers of elements. For gamma-ray spectrometers in the MeV range, the detector plane usually has only a few discrete elements, so that masks with small numbers of elements are called for. For this case it is feasible to analyze by computer all the possible mask patterns of given dimension to find the ones that best satisfy the desired performance criteria. A particular set of performance criteria for comparing the flux sensitivities, source positioning accuracies and transparencies of different mask patterns is developed. The results of such a computer analysis for masks up to dimension 5 x 5 unit cell are presented and it is concluded that there is a great deal of flexibility in the choice of mask pattern for each dimension.

Sembay, S.↗

Light masking of circadian rhythms of heat production, heat loss, and body temperature in squirrel monkeys

Whole body heat production (HP) and heat loss (HL) were examined to determine their relative contributions to light masking of the circadian rhythm in body temperature (Tb). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of body temperature and activity. Feeding was also measured. Responses to an entraining light-dark (LD) cycle (LD 12:12) and a masking LD cycle (LD 2:2) were compared. HP and HL contributed to both the daily rhythm and the masking changes in Tb. All variables showed phase-dependent masking responses. Masking transients at L or D transitions were generally greater during subjective day; however, L masking resulted in sustained elevation of Tb, HP, and HL during subjective night. Parallel, apparently compensatory, changes of HL and HP suggest action by both the circadian timing system and light masking on Tb set point. Furthermore, transient HL increases during subjective night suggest that gain change may supplement set point regulation of Tb.

Non-NASA Center↗

The Sensitivity of Coded Mask Telescopes

Simple formulae are often used to estimate the sensitivity of coded mask X-ray or gamma-ray telescopes, but t,hese are strictly only applicable if a number of basic assumptions are met. Complications arise, for example, if a grid structure is used to support the mask elements, if the detector spatial resolution is not good enough to completely resolve all the detail in the shadow of the mask or if any of a number of other simplifying conditions are not fulfilled. We derive more general expressions for the Poisson-noise-limited sensitivity of astronomical telescopes using the coded mask technique, noting explicitly in what circumstances they are applicable. The emphasis is on using nomenclature and techniques that result in simple and revealing results. Where no convenient expression is available a procedure is given which allows the calculation of the sensitivity. We consider certain aspects of the optimisation of the design of a coded mask telescope and show that when the detector spatial resolution and the mask to detector separation are fixed, the best source location accuracy is obtained when the mask elements are equal in size to the detector pixels.

Skinner, Gerald K.↗

Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

Achromatic↗

Universal parameters of bulk-solvent masks

The bulk solvent is a major component of biomacromolecular crystals that contributes significantly to the observed diffraction intensities. Accurate modelling of the bulk solvent has been recognized as important for many crystallographic calculations. Owing to its simplicity and modelling power, the flat (mask-based) bulk-solvent model is used by most modern crystallographic software packages to account for disordered solvent. In this model, the bulk-solvent contribution is defined by a binary mask and a scale (scattering) function. The mask is calculated on a regular grid using the atomic model coordinates and their chemical types. The grid step and two radii, solvent and shrinkage, are the three parameters that govern the mask calculation. They are highly correlated and their choice is a compromise between the computer time needed to calculate the mask and the accuracy of the mask. It is demonstrated here that this choice can be optimized using a unique value of 0.6 Å for the grid step irrespective of the data resolution, and the radii values adjusted correspondingly. The improved values were tested on a large sample of Protein Data Bank entries derived from X-ray diffraction data and are now used in the computational crystallography toolbox ( CCTBX ) and in Phenix as the default choice.

36 MATERIALS SCIENCE↗

Benchtop assessment of sealing efficacy and breathability of additively manufactured (AM) face masks

The onset of the 2019 novel coronavirus disease (COVID-19) led to a shortage of personal protective equipment (PPE), medical devices, and other medical supplies causing many stakeholders and the general public alike to turn to additive manufacturing (AM) as a stopgap when normally accessible devices were not available. However, without a method to test these AM constructs, there continued to be a disconnect between AM suppliers and the community’s needs. The objective of this study was to characterize the pressure drop and leakage of four different publicly available AM face mask models with two filter material combinations, as well as to investigate the impact of frame modification techniques including the use of foam strips and hot-water face forming to improve fit when the masks are donned on manikin head forms. AM face mask frame designs were downloaded from public repositories during the early stages of the COVID-19 pandemic. AM face masks were fabricated and tested on manikin head forms within a custom chamber containing dry aerosolized NaCl. Pressure drops, particle penetration, and leakage were evaluated for various flow rates and NaCl concentrations. Results indicated that filter material combination and frame modification played a major role in the overall performance of the AM face masks studied. Filter material combinations showed improved performance when high filtration fabric was used, and the cross-sectional area of the fabric was increased. AM frame modifications appeared to improve AM face mask leakage performance by as much as 69.6%.

36 MATERIALS SCIENCE↗

Original images, ground truth annotations, and precited masks from U-NET for a fungal species x nitrogen experiment

This document describes the “MicroVision-MV003” dataset. This folder contains three subfolders: “originals”, “predicted_masks”, and “gt_masks”. The “originals” folder contains 720 original images acquired using two imaging modalities: 360 images from overhead imaging and 360 images from transmission (raw) imaging. Naming scheme:YYYY-MM-dd__plate_strain_nitrogen-level_replication_experiment_imaging-modalityYYYY-MM-dd: 2024-12-20, 2024-12-21, 2024-12-22,2024-12-23,2024-12-24,2024-12-25,2024-12-26,2024-12-27,2024-12-28,2024-12-29,2024-12-30,2024-12-31.plate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30.strain: FG, LE.nitrogen-level: N-1, N-10, N-100.replication: 1, 2, 3, 4, 5.experiment: MV.003.imaging-modality: overhead, transmission (raw). For example, the image2024-12-20__1_FG_N-10_3_MV.003_overheadwas taken on 2024-12-20. The plate number is 1, the fungal strain is FG, the nitrogen treatment is N-10, and the replication number is 3 for experiment MV.003, acquired using the overhead imaging modality. The “predicted_masks” folder contains masks generated by a trained U-Net model for the transmission imaging modality.The “gt_masks” folder contains 326 human hand-traced masks that serve as ground truth.

09 BIOMASS FUELS↗

Influence of auditory fatigue on masked pure-tone thresholds

A description is presented of four related experiments involving conditions of 3-kHz low-intensity masking, a replication of experiment I with slight variations, 3-kHz high-intensity masking, and 6-kHz low-intensity masking. The frequencies of the tones which the observers detected were 3 and 6 kHz. The observed change in masked-tone threshold as a function of fatigue is discussed. It is found that masked-tone-detection thresholds remain essentially unchanged following fatigue if the masking-noise intensity is sufficiently great.

Parker, D. E.↗

Secondary gamma-ray production in a coded aperture mask

The application of the coded aperture mask to high energy gamma-ray astronomy will provide the capability of locating a cosmic gamma-ray point source with a precision of a few arc-minutes above 20 MeV. Recent tests using a mask in conjunction with drift chamber detectors have shown that the expected point spread function is achieved over an acceptance cone of 25 deg. A telescope employing this technique differs from a conventional telescope only in that the presence of the mask modifies the radiation field in the vicinity of the detection plane. In addition to reducing the primary photon flux incident on the detector by absorption in the mask elements, the mask will also be a secondary radiator of gamma-rays. The various background components in a CAMTRAC (Coded Aperture Mask Track Chamber) telescope are considered. Monte-Carlo calculations are compared with recent measurements obtained using a prototype instrument in a tagged photon beam line.

Owens, A.↗

Techniques for Producing Coastal Land Water Masks from Landsat and Other Multispectral Satellite Data

Coastal erosion and land loss continue to threaten many areas in the United States. Landsat data has been used to monitor regional coastal change since the 1970s. Many techniques can be used to produce coastal land water masks, including image classification and density slicing of individual bands or of band ratios. Band ratios used in land water detection include several variations of the Normalized Difference Water Index (NDWI). This poster discusses a study that compares land water masks computed from unsupervised Landsat image classification with masks from density-sliced band ratios and from the Landsat TM band 5. The greater New Orleans area is employed in this study, due to its abundance of coastal habitats and its vulnerability to coastal land loss. Image classification produced the best results based on visual comparison to higher resolution satellite and aerial image displays. However, density sliced NDWI imagery from either near infrared (NIR) and blue bands or from NIR and green bands also produced more effective land water masks than imagery from the density-sliced Landsat TM band 5. NDWI based on NIR and green bands is noteworthy because it allows land water masks to be generated from multispectral satellite sensors without a blue band (e.g., ASTER and Landsat MSS). NDWI techniques also have potential for producing land water masks from coarser scaled satellite data, such as MODIS.

Spruce, Joseph P.↗

Low-order aberration sensitivity of eighth-order coronagraph masks

In a recent paper, Kuchner, Crepp, and Ge describe new image-plane coronagraph mask designs that reject to eighth order the leakage of starlight caused by image motion at the mask, resulting in a substantial relaxation of image centroiding requirements compared to previous fourth-order and second-order masks. They also suggest that the new masks are effective at rejecting leakage caused by low-order aberrations (e.g., focus, coma, and astigmatism). In this paper, we derive the sensitivity of eighth-order masks to aberrations of any order and provide simulations of coronagraph behavior in the presence of optical aberrations.We find that the masks leak light as the fourth power of focus, astigmatism, coma, and trefoil. This has tremendous performance advantages for the Terrestrial Planet Finder Coronagraph.

planetary systems↗

Techniques for Producing Coastal Land Water Masks from Landsat and Other Multispectral Satellite Data

Coastal erosion and land loss continue to threaten many areas in the United States. Landsat data has been used to monitor regional coastal change since the 1970's. Many techniques can be used to produce coastal land water masks, including image classification and density slicing of individual bands or of band ratios. Band ratios used in land water detection include several variations of the Normalized Difference Water Index (NDWI). This poster discusses a study that compares land water masks computed from unsupervised Landsat image classification with masks from density-sliced band ratios and from the Landsat TM band 5. The greater New Orleans area is imployed in this study, due to its abundance of coastal habitats and ist vulnerability to coastal land loss. Image classification produced the best results based on visual comparison to higher resolution satellite and aerial image displays. However, density-sliced NDWI imagery from either near infrared (NIR) and blue bands or from NIR and green bands also produced more effective land water masks than imagery from the density-sliced Landsat TM band 5. NDWI based on NIR and green bands is noteworthy because it allows land water masks to be generated form multispectral satellite sensors without a blue band (e.g., ASTER and Landsat MSS). NDWI techniques also have potential for producing land water masks from coarser scaled satellite data, such as MODIS.

Spruce, Joe↗

Prediction and Evaluation of the Image of the WFIRST Coronagraph Pupil at the Shaped-Pupil Mask

To create a high contrast field of view with a shaped pupil coronagraph (SPC), the telescope pupil is imaged onto the shaped pupil mask, the shaped pupil mask is designed and fabricated through a design optimization based on a given pupil wavefront, and deformable mirrors (DM) in the coronagraph are modulated according to a nonlinear optimization procedure. Both the mask design optimization and the DM optimization require accurate knowledge of the image of the pupil at the shaped pupil plane for the calculation of Jacobians, and the evaluation of alignment tolerances. The shaped pupil coronagraphs demonstrated in the high contrast imaging testbed (HCIT) at JPL has heretofore assumed perfect imaging of the pupil onto the shaped pupil mask. Similarly, the design and performance modeling of the WFIRST CGI instrument makes the same assumption. In this paper we estimate and compare the image of the pupil mask at the shaped pupil plane in the case of the coronagraph testbed, and the image of the telescope pupil at the shaped pupil plane for the WFIRST CGI instrument. The estimated pupil images include field curvature and aberrations resulting from the layout of the parabolic mirror imaging system, which is optimized for the source image, not the image of the pupil. We also show the results of direct measurement of the image of the pupil mask at the shaped pupil plane in the coronagraph testbed.

Crowther, Blake↗

Initial Laboratory Demonstration of Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed

Online Abstract: A majority of Sun-like stars, such as the A and B components of Alpha Centauri, have at least one stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that removes stellar leakage from both stellar components, enabling direct imaging of planets in many binary star systems. We present the latest experimental and modeling results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI), and we used a MSWC mask similar to the one that was contributed to the Roman CGI. Our results represent the first demonstrations of this technique on the OMC testbed, with the ultimate goal of demonstrating full MSWC with validated models at contrast levels relevant to Roman CGI. Technical Review Abstract: A majority of Sun-like stars have at least one stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument, limiting the achievable contrast. These include high-quality target stars such as the A and B components of Alpha Centauri, our nearest stellar neighbor. Enabling direct imaging of binary stars has the potential to increase the scientific yield for coronagraphic instruments planned on NASA's future space missions including the Roman Space Telescope and the next IR/O/UV Flagship recommended by Astro2020. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that simultaneously removes the (mutually incoherent) stellar leakage from both stellar components, enabling direct imaging of planets in many binary star systems. MSWC is an algorithmic technique and can be used with existing wavefront control systems on coronagraphic instruments (as well as starshades if a deformable mirror is available in the optical path). We summarize the latest experimental and numerical results obtained with MSWC as part of the technology development effort to demonstrate compatibility with existing high-contrast imaging platforms for this technique. The Super-Nyquist regime of MSWC was tested in vacuum at JPL's High Contrast Imaging Testbed (HCIT) on the Decadal Survey Testbed (DST) reaching 8.6e-9 contrast in a 10% band. Recently, the Occulting Mask Coronagraph (OMC) testbed at JPL is being prepared for demonstrations of Multi-Star Wavefront Control. A shaped pupil mask similar to the contributed MSWC mask on the Roman Space Telescope's coronagraph instrument has been recently manufactured including matching Lyot and focal plane masks and being installed on the OMC testbed. The goal of this experiment is a demonstration of MSWC using validated models on a testbed configuration and at contrast levels relevant to the Roman coronagraphic instrument.

High-contrast imaging↗