Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The role of the reflection coefficient in precision measurement of ultrasonic attenuation

Ultrasonic attenuation measurements using contact, pulse-echo techniques are sensitive to surface roughness and couplant thickness variations. This can reduce considerable inaccuracies in the measurement of the attenuation coefficient for broadband pulses. Inaccuracies arise from variations in the reflection coefficient at the buffer-couplant-sample interface. The reflection coefficient is examined as a function of the surface roughness and corresponding couplant thickness variations. Interrelations with ultrasonic frequency are illustrated. Reliable attenuation measurements are obtained only when the frequency dependence of the reflection coefficient is incorporated in signal analysis. Data are given for nickel 200 samples and a silicon nitride ceramic bar having surface roughness variations in the 0.3 to 3.0 microns range for signal bandwidths in the 50 to 100 MHz range.

Generazio, E. R.↗

Ion Cyclotron Heating in a Levitated Dipole Fusion Reactor

OpenStar Technologies is pursuing the levitated dipole (LD) as a highly modular, loosely-coupled system that leverages their expertise in high temperature superconductor (HTS) technology. The next generation experiment at OpenStar, Tahi (Ma¯ori for “first”), will demonstrate the generation and confinement of fast ions in a levitated dipole for the first time. Ion cyclotron range of frequency (ICRF) heating is a leading candidate for energetic ion formation in Tahi. A frequency in the 10 MHz range will be used for H minority heating or D majority heating with waves launched from an antenna located above the floating coil. Unlike a tokamak, where the targeted cyclotron resonance is typically a vertical path through the center of the plasma, in a dipole the resonance location follows a C-shaped path from the separatrix to the center of the plasma. The value of B also varies significantly within the confined plasma resulting in a large number of cyclotron harmonics present in the low field region. Furthermore, levitated dipoles contain a “first closed flux surface” surrounding the floating coil, in addition to the traditional separatrix /last closed flux surface. Simulation e ff orts using full-wave ICRF codes show that ICRF heating of a levitated dipole reactor is feasible using a pair of toroidal current straps phased to launch the appropriate parallel ( i.e. poloidal) refractive index.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axion dark matter search with a photonic bandgap cavity haloscope and dielectric tuning rod over 10.25-10.45 GHz

We report the development of a new widely tunable cavity and demonstrate its use in a search for dark matter axions. We achieve unloaded quality factors above $10^{5}$, roughly $25\times$ larger than a bare copper cavity at the same frequency, using concentric sapphire shells to reduce Ohmic losses on the cavity barrel. A rotating sapphire rod tunes our cavity mode over the $10.1-11.7$ GHz range, approximately $16\%$ of its resonant frequency. Using an amplified receiver chain, we demonstrate sensitivity to new axion parameter space by tuning the cavity over the $200$ MHz range between $10.25-10.45$ GHz (42.4 - 43.2, $μ$eV) to constrain the axion-to-photon coupling to $|g_{aγγ}|$$\leq$ 1 $\times$$10^{-12}$${GeV}^{-1}$. This cavity can scan its tuning range about $9$ times faster compared to a bare copper cavity when paired with a photon counting device, laying the groundwork for a definitive search for the QCD axion over $10.1-11.7$ GHz.

Lynn, Morgan [Chicago U.]↗

Analysis of airborne RF measurements from U.S.A. urban areas

The paper presents in-situ, airborne survey radio-frequency measurements, which were made over the 400-1000 MHz range in May 1977 during the ASSESS-II Space Shuttle/Spacelab simulation aircraft flights. Measurements were made from altitudes of 10,000 to 33,000 feet with a downward-directed 70 deg wide, half-power beamwidth receiving antenna pattern. Channel occupancy percentages are given within a 50 MHz spectrum width, and continuous spectrum-scan measurements are presented for selected locations on the USA West Coast, showing the channel occupancy environment within the 806-890 MHz mobile-service band.

Taylor, R. E.↗

Digital Front End for Wide-Band VLBI Science Receiver

An upgrade to the very-long-baseline-interferometry (VLBI) science receiver (VSR) a radio receiver used in NASA's Deep Space Network (DSN) is currently being implemented. The current VSR samples standard DSN intermediate- frequency (IF) signals at 256 MHz and after digital down-conversion records data from up to four 16-MHz baseband channels. Currently, IF signals are limited to the 265-to-375-MHz range, and recording rates are limited to less than 80 Mbps. The new digital front end, denoted the Wideband VSR, provides improvements to enable the receiver to process wider bandwidth signals and accommodate more data channels for recording. The Wideband VSR utilizes state-of-the-art commercial analog-to-digital converter and field-programmable gate array (FPGA) integrated circuits, and fiber-optic connections in a custom architecture. It accepts IF signals from 100 to 600 MHz, sampling the signal at 1.28 GHz. The sample data are sent to a digital processing module, using a fiber-optic link for isolation. The digital processing module includes boards designed around an Advanced Telecom Computing Architecture (ATCA) industry-standard backplane. Digital signal processing implemented in FPGAs down-convert the data signals in up to 16 baseband channels with programmable bandwidths from 1 kHz to 16 MHz. Baseband samples are transmitted to a computer via multiple Ethernet connections allowing recording to disk at rates of up to 1 Gbps.

Jongeling, Andre↗

Submillimeter Planetary Atmospheric Chemistry Exploration Sounder

Planetary Atmospheric Chemistry Exploration Sounder (SPACES), a high-sensitivity laboratory breadboard for a spectrometer targeted at orbital planetary atmospheric analysis. The frequency range is 520 to 590 GHz, with a target noise temperature sensitivity of 2,500 K for detecting water, sulfur compounds, carbon compounds, and other atmospheric constituents. SPACES is a prototype for a powerful tool for the exploration of the chemistry and dynamics of any planetary atmosphere. It is fundamentally a single-pixel receiver for spectral signals emitted by the relevant constituents, intended to be fed by a fixed or movable telescope/antenna. Its front-end sensor translates the received signal down to the 100-MHz range where it can be digitized and the data transferred to a spectrum analyzer for processing, spectrum generation, and accumulation. The individual microwave and submillimeter wave components (mixers, LO high-powered amplifiers, and multipliers) of SPACES were developed in cooperation with other programs, although with this type of instrument in mind. Compared to previous planetary and Earth science instruments, its broad bandwidth (approx. =.13%) and rapid tunability (approx. =.10 ms) are new developments only made possible recently by the advancement in submillimeter circuit design and processing at JPL.

Schlecht, Erich T.↗

Recent progress in opto-electronic oscillator

The optoelectronic oscillator (OEO) is a unique device based on photonics techniques to generate highly spectrally pure microwave signals [1]. The development of the OEO was motivated by the need for high performance oscillators in the frequency range larger than 10 GHz, where conventional electronic oscillators have a number of limitations. These limitations typically stem from the product of fQ, where f is the oscillator frequency and Q is the quality factor of the resonator in the oscillator. In conventional resonators, whether electromagnetic or piezoelectric, this product is usually a constant. Thus, as the oscillator frequency is pushed higher, the quality factor degrades, resulting in degradation of the phase noise of the oscillator. An approach to mitigate the problem is to start with a very high quality signal in the 5 to 100 MHz range generated by a quartz oscillator and multiply the frequency to achieve the desired microwave signal. Here again, frequency multiplication also results in an increase of the phase noise by a factor of 2010gN, where N is the multiplication factor.

opto-electronic oscillators↗

Solar Flares, Type III Radio Bursts, Coronal Mass Ejections, and Energetic Particles

In this correlative study between greater than 20 MeV solar proton events, coronal mass ejections (CMEs), flares, and radio bursts it is found that essentially all of the proton events are preceded by groups of type III bursts and all are preceded by CMEs. These type III bursts (that are a flare phenomenon) usually are long-lasting, intense bursts seen in the low-frequency observations made from space. They are caused by streams of electrons traveling from close to the solar surface out to 1 AU. In most events the type III emissions extend into, or originate at, the time when type II and type IV bursts are reported (some 5 to 10 minutes after the start of the associated soft X-ray flare) and have starting frequencies in the 500 to approximately 100 MHz range that often get lower as a function of time. These later type III emissions are often not reported by ground-based observers, probably because of undue attention to type II bursts. It is suggested to call them type III-1. Type III-1 bursts have previously been called shock accelerated (SA) events, but an examination of radio dynamic spectra over an extended frequency range shows that the type III-1 bursts usually start at frequencies above any type II burst that may be present. The bursts sometimes continue beyond the time when type II emission is seen and, furthermore, sometimes occur in the absence of any type II emission. Thus the causative electrons are unlikely to be shock accelerated and probably originate in the reconnection regions below fast CMEs. A search did not find any type III-1 bursts that were not associated with CMEs. The existence of low-frequency type III bursts proves that open field lines extend from within 0.5 radius of the Sun into the interplanetary medium (the bursts start above 100 MHz, and such emission originates within 0.5 solar radius of the solar surface). Thus it is not valid to assume that only closed field lines exist in the flaring regions associated with CMEs and some interplanetary particles originating in such flare regions might be expected in all solar particle events.

Cane, Hilary V.↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

A prototype hybrid mode cavity for heterodyne axion detection

In the heterodyne approach to axion detection, axion dark matter induces transitions between two modes of a microwave cavity, resulting in a parametrically enhanced signal power. We describe the fabrication and characterization of a prototype normal conducting cavity specifically optimized for heterodyne detection. Corrugations on the cavity walls support linearly polarized hybrid modes which maximize the signal power while strongly suppressing noise. We demonstrate tuning mechanisms which allow one mode frequency to be scanned across a 4 MHz range, while suppressing cross-coupling noise by at least 80 dB. A future superconducting cavity with identical geometry to our prototype would have the potential to probe orders of magnitude beyond astrophysical bounds.

Li, Zenghai [SLAC]↗

Radio Frequency Sensor: Very High Frequency Radio Frequency Lightning Detection in Geostationary Orbit

Abstract The Radio Frequency Sensor (RFS), a new radio frequency lightning detector, was launched into geosynchronous orbit in December 2021, and first collected data in January 2022. RFS is a specialized software‐defined radio receiver that detects, records, and reports impulsive broadband radio‐frequency (RF) signatures from lightning in the very high frequency (VHF; 30–300 MHz) range. Its vantage point from a Western hemisphere geosynchronous orbit provides unique opportunities to study evolution of RF lightning signatures over the durations of thunderstorms over the Americas and Pacific Ocean. Its overlapping view with the Geostationary Lightning Mappers (GOES‐16 & 17) enables additional comparisons between the sources of optical emissions and associated VHF emissions that were not possible with previous sensors. We find that RFS preferentially detects bright VHF signals called transionospheric pulse pairs (trans‐ionospheric pulse pairs (TIPPs)). It is estimated that more than 85% of the RFS‐detected lightning events are TIPPs. This paper presents initial results from the first year and a half of on‐orbit operation.

54 ENVIRONMENTAL SCIENCES↗

Nonlinear signal distortion corrections through quantum sensing

Having accurate gate generation is essential for precise control of a quantum system. The generated gate usually suffers from linear and nonlinear distortion. Previous works have demonstrated how to use a qubit to correct linear frequency distortions but have not commented on how to handle nonlinear distortions. This is an important issue as we show that nonlinear amplitude distortions from the RF electronics can affect Rabi pulses by as much as 10%. We present work that demonstrates how a transmon qubit can be used as a highly sensitive cryogenic detector to characterize these nonlinear amplitude distortions. We show that a correction can drive these errors down to <1% over a 700 MHz range. The correction technique provides a method to minimize the effects of signal distortions and can be easily applied to broadband control pulses to produce higher fidelity arbitrary quantum gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radio frequency and DC high voltage breakdown of high pressure helium, argon, and xenon

Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is developing a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly larger electrode voltages than in existing systems. This mode of operation appears plausible for contemporary RF-carpet geometries due to the higher predicted breakdown strength of high pressure xenon relative to low pressure helium, the working medium in most existing RF carpet devices. In this paper we present the first measurements of the high voltage dielectric strength of xenon gas at high pressure and at the relevant RF frequencies for ion transport (in the 10 MHz range), as well as new DC and RF measurements of the dielectric strengths of high pressure argon and helium gases at small gap sizes. We find breakdown voltages that are compatible with stable RF carpet operation given the gas, pressure, voltage, materials and geometry of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

High- Q Microwave Dielectric Resonator for Axion Dark-Matter Haloscopes

The frequency band 1–15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high-quality factor cavities that tolerate multitesla fields plays a central role. We report a three-dimensional resonator based on a right-circular copper cavity with hollow cylinders that confine higher-order modes around the cylinder axis. Its effective volume at 10.3 GHz is 3.4 × 10 − 2 l, and under an 8-T field we measure an internal quality factor of more than nine million. A fine-tuning system limited to approximately 1 -MHz range is tested, useful for understanding the conditions required to run a haloscope with a cavity exceeding the axion quality factor. The cavity parameters we report demonstrate the potential of this unique resonator to probe galactic dark-matter axion at scan rates exceeding 2 MHz/day when the cavity is readout by a quantum-limited receiver.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent High-Frequency Axial Oscillations in a Partially Magnetized Direct Current Magnetron Discharge

High-frequency oscillations are observed in a neon plasma of a direct current magnetron discharge. At low discharge currents, we see highly coherent 60 MHz fluctuations. Above a distinct current threshold, secondary 5–10 MHz fluctuations emerge in addition to turbulent fluctuations in the 60–100 MHz range. The oscillations in the total discharge current suggest axial wave propagation. A lower-hybrid wave theory is invoked to model the high-frequency oscillations. Here, we attribute the low-frequency modes to a turbulence-driven inverse cascade process, as suggested by recent simulations.

33 ADVANCED PROPULSION SYSTEMS↗

Fault-tolerant optical interconnects for neutral-atom arrays

We analyze the use of photonic links to enable large-scale fault-tolerant connectivity of locally error-corrected modules based on neutral atom arrays. Our approach makes use of recent theoretical results showing the robustness of surface codes to boundary noise and combines recent experimental advances in atom-array quantum computing with logical qubits with optical quantum networking techniques. We find the conditions for fault tolerance can be achieved with local two-qubit Rydberg gate and nonlocal Bell-pair errors below 1% and 10%, respectively, without requiring distillation or space-time overheads. Realizing the interconnects with a lens, a single optical cavity, or an array of cavities enables—with sufficient multiplexing—a Bell-pair generation rate in the 1–50 MHz range. When directly interfacing logical qubits, this rate translates to error-correction cycles in the 25–2000 kHz range, satisfying all requirements for fault tolerance and in the upper range fast enough for 100 kHz logical clock cycles. Published by the American Physical Society 2025

Sinclair, Josiah (ORCID:0000000215238295)↗