Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Installation of the Dark Energy Spectroscopic Instrument at the Mayall 4-meter telescope

The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. We describe the installation of the major elements of the instrument at the Mayall 4m telescope, completed in late 2019. The previous prime focus corrector, spider vanes, and upper rings were removed from the Mayall’s Serrurier truss and replaced with the newlyconstructed DESI ring, vanes, cage, hexapod, and optical corrector. The new corrector was optically aligned with the primary mirror using a laser tracker system. The DESI focal plane system was integrated to the corrector, with each of its ten 500-fiber-positioner petal segments installed using custom installation hardware and the laser tracker. Ten DESI spectrographs with 30 cryostats were installed in a newly assembled clean room in the Large Coude Room. The ten cables carrying 5000 optical fibers from the positioners in the focal plane were routed down the telescope through cable wraps at the declination and hour angle axes, and their integral slitheads were integrated with the ten spectrographs. The fiber view camera assembly was installed to the Mayall’s primary mirror cell. Servers for the instrument control system replaced existing computer equipment. The fully integrated instrument has been commissioned and is ready to start its operations phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Missing Correlation Between the Potential Rate Impacts of Rooftop Solar and the Timing of State Net Metering Policy Revisions

Data supporting the article “The Missing Correlation Between the Potential Rate Impacts of Rooftop Solar and the Timing of State Net Metering Policy Revisions” (https://www.nlr.gov/docs/fy25osti/93543.pdf). Residential solar photovoltaic (PV) output in most states is credited at the retail electricity rate, a policy commonly known as net metering. Twelve states have replaced net metering with alternative rate structures that reduce PV adopter bill savings. Proponents of these revisions argue that net metering increases the electricity rates of customers without PV. Here, we analyze the degree to which the timelines of net metering revisions have correlated with potential electricity rate impacts. We estimate that potential rate impacts at the end of 2023 were less than 1% of typical customer bills in 37 of 44 states that have offered net metering. There are no statistically significant differences in average or median estimated rate impacts between states that have and have not revised net metering. Nine of the states that had revised net metering did so when estimated impacts were less than 1% of typical customer bills. Many states have retained net metering into higher PV deployment levels with increased risk of potential rate impacts. Only two states-California and Hawaii-retained net metering beyond estimated rate impacts of 5%, and both have revised net metering. These findings do not suggest a clear, consistent link between net metering revision timelines and potential rate impacts. The timing and nature of net metering revisions are ultimately policy decisions based on state-level priorities and considerations.

14 SOLAR ENERGY↗

The missing correlation between the potential rate impacts of rooftop solar and the timing of state net metering policy revisions

Residential solar photovoltaic (PV) output in most states is credited at the retail electricity rate, a policy commonly known as net metering. Twelve states have replaced net metering with alternative rate structures that reduce PV adopter bill savings. Proponents of these revisions argue that net metering increases the electricity rates of customers without PV. Here, we analyze the degree to which the timelines of net metering revisions have correlated with potential electricity rate impacts. We estimate that potential rate impacts at the end of 2023 were less than 1% of typical customer bills in 37 of 44 states that have offered net metering. There are no statistically significant differences in average or median estimated rate impacts between states that have and have not revised net metering. Nine of the states that had revised net metering did so when estimated impacts were less than 1% of typical customer bills. Many states have retained net metering into higher PV deployment levels with increased risk of potential rate impacts. Only two states—California and Hawaii—retained net metering beyond estimated rate impacts of 5%, and both have revised net metering. These findings do not suggest a clear, consistent link between net metering revision timelines and potential rate impacts. The timing and nature of net metering revisions are ultimately policy decisions based on state-level priorities and considerations.

14 SOLAR ENERGY↗

Advanced Metering Infrastructure for Distribution Planning and Operation: Closing the Loop on Grid-Edge Visibility

In the recent history of electric utilities, the potential to have visibility of the grid edge is gaining significance for the reliable planning and operation of a clean energy smart grid. Before the recent large-scale customer adoption of distributed energy resources (DERs), distribution networks were planned with a simpler fit-and-forget philosophy. The importance of customer-sited DERs to achieve climate change goals marks a major shift for utility operations. Changes to traditional fit-and-forget planning paradigms require better availability of grid-edge data. Smart metering is an enterprise-wide tool that is enabling visibility when and where it has been most needed. As of 2020, the rollout of smart metering, or advanced metering infrastructure (AMI), had reached more than 100 million meters in the United States, and nearly half of all electricity customers are now equipped with a smart meter (Figure 1). Smart meters are quickly becoming a ubiquitous data capture feature of smart grids. AMI enables utilities to record and measure electricity usage and power-flow metrics at a minimum of hourly intervals and at least once a day. At a minimum, AMI enables interval metering, automatic meter reading enabling accurate and time-interval billing, and the ability to provide feedback on customer energy consumption.

advanced metering infrastructure↗

Homomorphic Encryption for Electrical Metering Aggregation: Protecting the Privacy of Building Tenants

Electrical meters are devices that measure consumer electricity usage. The data collected by these meters is necessary for utility billing and electrical grid management but can also be used to assess the environmental impact of buildings. Prior research has found that unprotected metering data could potentially be used to infer some information about the behaviors of building tenants by detecting changes in electricity usage. For example, a period of low electricity usage could suggest that the tenants are not in the building. As smart metering becomes more common, there is a growing need for data privacy protections for metering data that do not negatively impact the quality and availability of data used for energy management and billing applications. To identify potential solutions, we developed a Python-based data aggregation platform to analyze the potential efficacy of privacy-enhancing technologies for energy metering applications. This platform aggregates groups of metering sites into virtual buildings, which could potentially detach changes in electrical activity from individual tenants, making it more difficult to track the activity of a specific tenant. To further protect data during analysis, this project utilizes homomorphic encryption as part of its initial approach. Homomorphic encryption offers a means of protecting energy consumption data while permitting mathematical operations to be performed without the need to know the data contents. This allows for data to be processed into usable statistics without revealing energy consumption information. A series of homomorphic encryption libraries were evaluated to determine their applicability and limitations in the context of metering data. The use of these techniques may help to reassure consumers and encourage further adoption of smart grid infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Federal Metering Guidance

The Federal Metering Guidance documents the metering provisions in EO 13834, Efficient Federal Operations and other metering related statutory requirements. This document provides the meter-related reporting requirements for Federal agencies, specifies a method to verify the existence of currently installed building-level meters, provides guidelines on prioritizing the implementation of advanced energy and water meters, sets the schedule for agencies to update their five-year metering plans, provides the minimum requirements that agencies must meet when updating their five-year metering plans along with recommend elements for an effective plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unbundling Smart Meter Services Through Spatio-Temporal Decomposition Agents in DER-rich Environment

Smart meters and the advanced metering infrastructure (AMI) facilitate distribution system operators (DSOs) to gather information on energy consumption at the customer level. With the increasing penetration of building-level intermittent distributed energy resources (DERs) behind the meter, DER information is not available to DSOs. At the same time, smart meter enables users to participate in grid, with real-time information. Information for behind the meter is needed by user to coordinate building level assets for maximum benefits. The concept of unbundled smart meter (USM) needs agents to decompose smart meter measurements to provide service to DSO as well as customers. In this paper, we propose a Spatio-Temporal Decomposition Agent (STDA) for USM based on Artificial Intelligence (AI). STDA can help users optimize their energy usage, help DSO to utilize building assets for the grid operation. The energy usage strategy developed by STDA is suitable for different users, and can be customized by deep learning (DL) models according to the different energy consumption habits of each user. The power prediction performance results of various DL models and evaluation using a set of data from a Hawaii utility is presented. Furthermore, STDA integration with Home Energy management Systems (HEMS) to manage resources is presented and validated. STDA pre-processes the measurements before model training, and provides the spatio-temporal decomposed forecasting.

42 ENGINEERING↗

Smart Meters Enabling Voltage Monitoring and Control Functionalities: The Last-Mile Voltage Stability Issue

It is a demanding yet challenging task to design the next generation of smart meters. This work investigates the new voltage monitoring and control function for the next-generation smart meters, and identifies its added values for power system voltage stability issues. In terms of voltage monitoring, the risk benefit analysis for adding voltage magnitudes to smart meter measurements is presented, and the risk mitigation strategies along with the co-simulation validation via GridLAB-D and NS-3 are proposed, all providing insight into the new function evaluation. In terms of voltage control, a new voltage stability control scheme is developed, which uses voltage measurements from smart meters and utilizes the observability and controllability of distributed energy resources and controllable loads. Different from traditional voltage control schemes focusing on voltage regulation and power quality monitoring from the utility perspective, the proposed control scheme can achieve the maximum real power transfer margin at the end user side, enabling the voltage stability issues being solved at the grid edge, i.e. the last-mile segment. It is the first work that considers voltage monitoring and control collectively for smart meter investment. It can help power engineering community supplement smart meter applications and shape the next-generation smart meters.

42 ENGINEERING↗

A Review of Behind-the-Meter Solar Generation Modeling and Forecasting

Solar photovoltaic systems largely integrated within the distribution grid are operated 'behind-the-meter' and power generation cannot be directly monitored by most utilities. The increasing penetration of behind-the-meter solar photovoltaic systems can deter efficient network and market operations due to variability and uncertainty in net load, which is exacerbated by limited visibility and the difficulty in analyzing the hosting capacity. Risk introduced by behind-the-meter solar contributions may hinder reliable and secure grid operations due to biased system monitoring and forecasts. Accurate behind-the-meter estimations, together with capacity and specification forecasts, thus play a key role in balancing supply and demand and this article reviews the pertinent literature, identifying key characteristics and predictive methods for efficient behind-the-meter solar photovoltaic generation. Forecasting is central to methods herein. The fundamental characteristics of behind-the-meter solar forecasting, including which methods are applicable for scenario-driven use cases, are driven by the metrics most useful for system-wide performance evaluation. To this aim, the literature is reviewed with a focus on forecasting applications for aggregate, regional behind-the-meter generation useful to bulk system and utility operations. As distinguished from net load forecasting, subtleties in these coincident tasks are explored before concluding with recommendations for current practice and future implementations.

behind-the-meter↗

Can portable glucose and lactate meters be a useful tool in quantifying stress of juvenile Chinook salmon?

Blood plasma analyses can provide researchers, aquaculture facilities and fisheries managers with valuable insights into the physiological state and welfare of fish. For example, glucose and lactate are part of the secondary stress response system, and elevated concentrations are indicators of stress. However, analysing blood plasma in the field can be logistically difficult and typically involves sample storage and transport to quantify concentrations in a laboratory setting. Portable glucose and lactate meters offer an alternative to laboratory assays and have shown to be relatively accurate in fish, but these tools have only been validated for a few fish species. The objective of this study was to investigate if portable meters could be reliably used in Chinook salmon (Oncorhynchus tshawytscha). As part of a larger stress response study, juvenile Chinook salmon (157 ± 17 mm fork length [mean ± standard deviation; SD]) were exposed to stress-inducing treatments and sampled for blood. Laboratory reference glucose concentrations (milligrams per deciliter; mg/dl; n = 70) were positively correlated with the Accu-Check Aviva meter (Roche Diagnostics, Indianapolis, IN) measurements (R 2 = 0.79), although glucose values were 1.21 ± 0.21 (mean ± SD) times higher in the laboratory than with the portable meter. Lactate concentrations (milliMolar; mM; n = 52) of the laboratory reference were also positively correlated (R 2 = 0.76) with the Lactate Plus meter (Nova Biomedical, Waltham, MA) and were 2.55 ± 0.50 times higher than portable meter. Our results indicate both meters could be used to measure relative glucose and lactate concentrations in Chinook salmon and provide fisheries professionals with a valuable tool, particularly in remote field settings.

59 BASIC BIOLOGICAL SCIENCES↗

Equitable Design of Behind-the-Meter Energy Storage Programs: A Customer Perspective

Utility deployment of energy storage is done as a utility-scale asset connected directly to the grid (front of meter) or in partnership with a customer on the customer’s premises (behind the meter). By offering incentives for customers to install behind-the-meter storage, utilities can gain operational control of the assets and operate them in a manner that benefits all customers. Some states have also begun providing increased incentive levels to low-income customers to ensure that they can equitably share in the benefits of behind-the-meter energy storage programs. This paper evaluates different approaches to energy storage procurement from the customer’s perspective and evaluates how behind-the-meter programs can be equitably structured while keeping customers financially indifferent between front-of-meter and behind-the-meter energy storage procurements.

Twitchell, Jeremy B.↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generation and representation of synthetic smart meter data

Advanced energy algorithms running at big-data scale will be necessary to identify, realize, and verify energy savings to meet government and utility goals of building energy efficiency. Any algorithm must be well characterized and validated before it is trusted to run at these scales. Smart meter data from real buildings will ultimately be required for the development, testing, and validation of these energy algorithms and processes. However, for initial development and testing, smart meter data are difficult to work with due to privacy restrictions, noise from unknown sources, data accessibility, and other concerns which can complicate algorithm development and validation. This paper describes a new methodology to generate synthetic smart meter data of electricity use in buildings using detailed building energy modeling, which aims to capture the variability and stochastics of real energy use in buildings. The methodology can create datasets tailored to represent specific scenarios with known truth and controllable amounts of synthetic noise. Knowledge of ground truth also allows the development and validation of enhanced processes which leverage building metadata, such as building type or size (floor area), in addition to smart meter data. The methodology described in this paper includes the key influencing factors of real-world building energy use including weather data, occupant-driven loads, building operation and maintenance practices, and special events. Data formats to support workflows leveraging both synthetic meter data and associated metadata are proposed and discussed. Finally, example use cases of the synthetic meter data are described to illustrate potential applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rooftop Solar Deployment, Potential Electricity Rate Impacts, and the Timing of Revisions to State Net Metering Policy

Most U.S. states require utilities to credit residential solar photovoltaic (PV) output at the retail electricity rate, a structure known as net metering. However, 12 states have replaced net metering with alternative rate structures that reduce PV adopter bill savings. The share of households living in states that require net metering fell from around 84% in 2014 to around 57% by the end of 2023. Proponents of net metering revisions have argued that net metering can affect the electricity rates of customers without PV. This report analyzes the relationships between state PV deployment levels, potential electricity rate impacts on PV nonadopters, and the timing of revisions to net metering policy.

14 SOLAR ENERGY↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

Synchronized electric meter having an atomic clock

Smart electric meters configured to perform fast, time-synchronized electrical energy measurements at the consumer-level are disclosed herein. In some embodiments, a smart electric meter includes circuitry configured to measure an electrical value at a location of an end user in a power system. The smart electric meter can further include an atomic clock configured to output a timing signal, and a controller configured to receive (a) the measured electrical value from the circuitry and (b) the timing signal from the atomic clock. The controller can further (a) process the electrical value to generate meter data and (b) generate a time tag based on the timing signal. Then, the controller can associate the time tag with the meter data to generate time-tagged meter data.

Min, Liang↗

Enriching Load Data Using Micro-PMUs and Smart Meters

In modern distribution systems, load uncertainty can be fully captured by micro-PMUs, which can record high-resolution data; however, in practice, micro-PMUs are installed at limited locations in distribution networks due to budgetary constraints. In contrast, smart meters are widely deployed but can only measure relatively low-resolution energy consumption, which cannot sufficiently reflect the actual instantaneous load volatility within each sampling interval. In this paper, we have proposed a novel approach for enriching load data for service transformers that only have low-resolution smart meters. The key to our approach is to statistically recover the high-resolution load data, which is masked by the low-resolution data, using trained probabilistic models of service transformers that have both high- and low-resolution data sources, i.e., micro-PMUs and smart meters. The overall framework consists of two steps: first, for the transformers with micro-PMUs, a Gaussian Process is leveraged to capture the relationship between the maximum/minimum load and average load within each low-resolution sampling interval of smart meters; a Markov chain model is employed to characterize the transition probability of known high-resolution load. Next, the trained models are used as teachers for the transformers with only smart meters to decompose known low-resolution load data into targeted high-resolution load data. The enriched data can recover instantaneous load uncertainty and significantly enhance distribution system observability and situational awareness. Here, we have verified the proposed approach using real high- and low-resolution load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗