Thin-Film Solar Cells on Metal Foil Substrates for Space Power

Photovoltaic arrays have played a key role in power generation in space. The current technology will continue to evolve but is limited in the important mass specific power metric (MSP or power/weight ratio) because it is based on bulk crystal technology. The objective of this research is to continue development of an innovative photovoltaic technology for satellite power sources that could provide up to an order of magnitude saving in both weight and cost, and is inherently radiation-tolerant through use of thin film technology and thin foil substrates such as 5-mil thick stainless steel foil or 1-mil thick Ti. Current single crystal technology for space power can cost more than $300 per watt at the array level and weigh more than 1 kg/sq m equivalent to specific power of approx. 65 W/kg. Thin film material such as CuIn(1-x),Ga(x)S2, (CIGS2), CuIn(1-x), G(x)Se(2-y),S(y), (CIGSS) or amorphous hydrogenated silicon (a-Si:H) may be able to reduce both the cost and mass per unit area by an order of magnitude. Manufacturing costs for solar arrays are an important consideration for total spacecraft budget. For a medium sized 5kW satellite, for example, the array manufacturing cost alone may exceed $2 million. Moving to thin film technology could reduce this expense to less than $500 K. Previous work at FSEC demonstrated the potential of achieving higher efficiencies from CIGSS thin film solar cells on 5-mil thick stainless steel foil as well as initial stages of facility augmentation for depositing thin film solar cells on larger (6"x 4") substrates. This paper presents further progress in processing on metal foil substrates. Also, previous work at DayStar demonstrated the feasibility of flexible-thin-film copper-indium-gallium-diselenide (CIGS) solar cells with a power-to-weight ratio in excess of 1000 W/kg. We will comment on progress on the critical issue of scale-up of the solar cell absorber deposition process. Several important technical issues need to be resolved to realize the benefits of lightweight technologies for solar arrays, such as: monolithic interconnects, lightweight array structures, and new ultra-light support and deployment mechanisms. Once the technology has gained spaceflight certification it should find rapid acceptance in specific satellite markets.

Raffaelle, Ryne P.↗

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE↗

Porus electrode comprising a bonded stack of pieces of corrugated metal foil

An electrode suitable for use in an electrochemical cell is described. The electrode is composed of a porous conductive support with a bonded stack of pieces of thin corrugated nickel foil where the corrugations are oriented approximately perpendicular to the sides of the electrode and form an array of passages through the electrode. Active material such as cadmium hydroxide or nickel hydroxide is uniformly distributed within the passages. The support may comprise also a piece of thin flat nickel foil between adjacent pieces of the corrugated foil, forming a barrier between the passages formed on each side of it. Typically the corrugations in the odd corrugated layers are oriented at a small angle from the perpendicular in one direction and the corrugations in the even corrugated layers are oriented at a small angle from the perpendicular in the opposite direction.

Mccallum, J.↗

Composite heat pipe development status: Development of lightweight prototype carbon-carbon heat pipe with integral fins and metal foil liner

This report discusses development and proof-of-concept testing of a new lightweight carbon-carbon (C-C) space radiator heat pipe, carried out under the NASA Civil Space Technology Initiative (CSTI) High Capacity Power Program. The prototype heat pipe, equipped with a niobium-zirconium foil liner, was filled with potassium working fluid and tested for 11 hours, including startup from ambient temperature with the working fluid initially in the frozen state to near 700 K condenser temperature. Steady-state heat pipe input power during testing was facility limited to about 300 watts. Post test inspection showed the heat pipe to be in excellent condition after eight thermal cycles from ambient to steady-state operating temperature. Utilization of other liner materials and working fluids would greatly extend the spectrum of service temperatures for this technology, with potential applications ranging from small spacecraft heat rejection to aircraft and terrestrial uses.

Juhasz, Albert J.↗

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 micrometers thick) that are wrapped around the sample tray assembly. Soda lime spheres (approximately 49 m in diameter) have been accelerated with a light-gas-gun into flight-grade Al foils at 6.35 km s(sup -1) to simulate the potential capture of cometary debris. The preserved crater penetrations have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, high-precision focused ion beam (FIB) milling has been used to isolate and then extract an individual melt residue droplet from the interior wall of an impact penetration. This enabled further detailed elemental characterization, free from the background contamination of the Al foil substrate. The ability to recover pure melt residues using FIB will significantly extend the interpretations of the residue chemistry preserved in the Al foils returned by Stardust.

Graham, G. A.↗

Elevated-Temperature Tensile-Testing of Foil-Gage Metals

Automated system for measuring strain in metal foils at temperatures above 500 degrees F (260 degrees C) uses mechanical extensometer and displacement transducer. System includes counterbalance feature, which eliminates weight contribution of extensometer and reduces grip pressure required for attachment to specimen. Counterbalancing feature overcomes two major difficulties in using extensometers with foil-gage specimens: (1) Weight of extensometer and transducer represents significant fraction of total load applied to specimen and may actually damage it; and (2) grip pressure required for attachment of extensometer to specimens may induce bending stresses in foil-gage materials.

Blackburn, L. B.↗

Lithium-Ion Batteries with Safer Current Collectors

The US Department of Energy’s Oak Ridge National Laboratory and Soteria Battery Innovation Group collaborated to develop a metallized polymer film as a current collector for lithium-ion batteries and design slit patterns for electrodes to improve battery safety. The metallized polymer film serves as a fuse that will break under high temperature resulting from a short circuit. Consequently, the short circuit will be broken and the heat generated from the short circuit will be alleviated to avoid thermal runaway. The electrodes with slit patterns are expected to be broken into small segments upon mechanical impact, which can isolate the damaged electrodes from the rest. Thus, the heat generation associated with the mechanical impact will be reduced, along with the likelihood of thermal runaway. This effort aimed to improve lithium-ion battery safety by replacing traditional metal foils with metallized polymer films as current collector and introducing slit patterns to battery electrodes. The metallized polymer films were polyethylene terephthalate with a thin metal (aluminum for cathodes and copper for anodes) coating on both sides. Slit patterns with various geometries and dimensions were designed via simulation. Temperature distribution on cells with electrodes with and without slit patterns was also simulated via nemerical modeling. Electrodes on traditional metal foils and metallized polymer films were coated via a pilot-scale slot-die coater at the US Department of Energy Battery Manufacturing Facility at Oak Ridge National Laboratory. The electrodes were calendered to 35% porosity and punched out with and without slit patterns. Pouch cells were assembed with the electrodes inside a dry room for electrochemical and safety testing. Electrodes coated on metallized polymer films exhibited comparable electrochemical performance to their counterparts coated on traditional metal foils. They also showed improved safety in nail penetration and indentation tests.

25 ENERGY STORAGE↗

Intrinsic thermal interfacial resistance measurement in bonded metal–polymer foils

Heat conduction through bonded metal–polymer interfaces often limits the overall heat transfer in electronic packaging, batteries, and heat recovery systems. To design the thermal circuit in such systems, it is essential to measure the thermal interfacial resistance (TIR) across ~1 µm to 100 µm junctions. Previously reported TIR of metal–polymer junctions utilize ASTM E1530-based two-block systems that measure the TIR by applying pressure across the interface through external heating and cooling blocks. Here, we report a novel modification of the ASTM-E1530 technique that employs integrated heaters and sensors to provide an intrinsic TIR measurement of an adhesively bonded metal–polymer junction. We design the measurement technique using finite element simulations to either passively suppress or actively compensate the lateral heat diffusion through the polymer, which can minimize the systematic error to ≲5%. Through proof-of-concept experiments, we report the TIR of metal–polymer interfaces made from DuPont’s Pyralux double-side copper-clad laminates, commonly used in flexible printed circuit boards. Our TIR measurement errors are <10%. We highlight additional sources of errors due to non-idealities in the experiment and discuss possible ways to overcome them. Our measurement technique is also applicable to interfaces that are electrically insulating such as adhesively joined metal–metal junctions and sputter-coated or welded metal–polymer junctions. Altogether, the technique is capable of measuring TIR ≳10 –5 m 2 KW –1 in bonded metal–polymer foils and can be tailored for in situ measurements in flexible electronics, circuit packaging, and other hybrid metal–polymer systems.

47 OTHER INSTRUMENTATION↗

Method of Suppressing Sublimation in Advanced Thermoelectric Devices

A method of applying a physical barrier to suppress thermal decomposition near a surface of a thermoelectric material including applying a continuous metal foil to a predetermined portion of the surface of the thermoelectric material, physically binding the continuous metal foil to the surface of the thermoelectric material using a binding member, and heating in a predetermined atmosphere the applied and physically bound continuous metal foil and the thermoelectric material to a sufficient temperature in order to promote bonding between the continuous metal foil and the surface of the thermoelectric material. The continuous metal foil forms a physical barrier to enclose a predetermined portion of the surface. Thermal decomposition is suppressed at the surface of the thermoelectric material enclosed by the physical barrier when the thermoelectric element is in operation.

Sakamoto, Jeffrey S.↗

Growth of carbon nanotube forests on flexible metal substrates: Advances, challenges, and applications

Owing to their remarkable properties and ordered architecture, vertically aligned CNT forests (VACNT) hold promises for countless applications ranging from energy storage to multifunctional fiber production. Over the last three decades, studies of carbon nanotube (CNT) growth have provided invaluable insight into the CNT nucleation and growth mechanism and enabled critical advancements in nanotechnology. Nevertheless, the ability to fully harness the exceptional VACNT properties in commercial devices is bottlenecked by compatibility of current CNT synthesis processes with large-scale manufacturing. Metal foil substrates present an economic alternative to traditional insulating substrates, like silicon or quartz, and are compatible with both roll-to-roll and automated, large-scale, batch processes. Compared to CNT growth on Si substrates, metal foils present additional challenges, such as increased roughness and reactivity at high temperatures. Nonetheless, many successful VACNT growths on conducting metal foils have been reported, which demonstrate the feasibility of metal substrate use for large-volume production of high-quality CNTs. Here, in this review, we discuss advancements in the field of VACNT growth on metal foil and specifically examine different choices for metal substrates, barrier and catalyst layers, deposition and growth methods, resulting CNT characteristics, and highlight a number of applications that benefit from CNT growth on metal substrates and transition to large-scale manufacturing.

36 MATERIALS SCIENCE↗

Collection and analysis of cometary dust during a rendezvous mission

An experimental program has been undertaken to investigate and develop methods for high-efficiency collection of dust particles during a rendezvous mission with a preselected comet. A laboratory apparatus has been designed and tested for acceleration of fine particles (0.1 to 100 microns) to velocities of 0.5 to 50 m/s. Tests of collection efficiency are being conducted under vacuum and with control of substrate temperature. Collection materials include filters, plastic films, metal foils, liquid metals, and sticky organic compounds. Results to date indicate that only certain materials will be adequate to meet collection requirements.

Clark, B. C.↗

Growth and Performance of High-Quality SWCNT Forests on Inconel Foils as Lithium-Ion Battery Anodes

Large-scale production of vertically aligned single-walled carbon nanotubes (VA-SWCNTs) on metal foils promises to enable technological advancements in many fields, from functional composites to energy storage to thermal interfaces. In this work, we demonstrate growth of high-quality (G/D > 6, average diameters ~ 2–3 nm, densities > 10 12 cm –2 ) VA-SWCNTs on Inconel metal for use as a lithium-ion battery (LIB) anode. Scale-up of SWCNT growth on Inconel 625 to 100 cm 2 exhibits nearly invariant CNT structural properties, even when synthesis is performed near atmospheric pressure, and this robustness is attributed to a growth kinetic regime dominated by the carbon precursor diffusion in the bulk gas mixture. SWCNT forests produced on large-area metal substrates at close to atmospheric pressure possess a combination of structural features that are among the best demonstrated so far in the literature for growth on metal foils. Leveraging these achievements for energy applications, we demonstrate a VA-SWCNT LIB anode with capacity >1200 mAh/g at 1.0C and stable cycling beyond 300 cycles. Furthermore, this robust synthesis of high-quality VA-SWCNTs on metal foils presents a promising route toward mass production of high-performance CNT devices for a broad range of applications.

Energy↗

Strain measurement technique for elevated temperature tensile and creep testing of foil-gage metals

This paper describes a strain measurement technique suitable for elevated-temperature tensile and creep testing of foil-gage metals, using a modified commonly available mechanical extensometer in conjunction with a displacement transducer. The extensometer was modified by attaching to it a counterbalance (to reduce the effect of the extensometer weight on the total maximum test load) and by incorporating a conical tip/flat-edge design (to minimize induced stresses in the specimen resulting from extensometer attachment). Creep tests were performed on 0.102-mm-thick specimens of Ti-6Al-4V at temperatures of 427 and 538 C, at nominal applied stresses of 310.3 and 172.4 MPa, respectively. Examination of the resulting creep curves suggested that the strain measurement system provided actual creep strain values with good accuracy.

Blackburn, L. B.↗

Creep testing of foil-gage metals at elevated temperature using an automated data acquisition system

A method is being developed to obtain creep data on foil gage metals at elevated temperatures using an automated data acquisition system in conjunction with a mechanically counter balanced extensometer. The automated system components include the Hewlett-Packard (HP) 9845A desktop computer, the HP 3455A digital voltmeter and the HP 3495A scanner. Software for test monitoring and data collection was developed; data manipulation, including curve plotting was done with a HP regression analysis software package. Initial creep tests were conducted on .003 in. thick foil specimens of Ti-6A1-4V at temperatures of 800 F and 1000 F and at stress levels of 25 ksi and 45 ksi. For comparison, duplicate tests were run on .049 in. thick specimens sheet of the same alloy. During testing, the furnace and specimen temperature, bridge voltage, strain and load output were automatically monitored and recorded at predetermined intervals. Using the HP regression analysis program, recorded strain output was plotted as a function of time. These resultant creep curves indicate that, under similar conditions of temperature and stress, foil gage specimens exhibit a higher creep rate than sheet specimens.