Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Auditory Evoked Responses in Neonates by MEG

Magnetoencephalography is a biomagnetic technique with outstanding potential for neurodevelopmental studies. In this work, we have used MEG to determinate if newborns can discriminate between different stimuli during the first few months of life. Five neonates were stimulated during several minutes with auditory stimulation. The results suggest that the newborns are able to discriminate between different stimuli despite their early age.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The MEG experiment: status and perspectives

The MEG experiment, a sensitive search for the mu->egamma decay, has started operating in September 2008. Analysis of data collected during the initial three months of operation is still ongoing and soon to be finalized. The detector performance during Run 2008 is reviewed, with remarks on perspectives for Run 2009.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MEG Experiment - New Result and Prospects

The MEG Experiment searches for a lepton flavour violating muon decay, {mu}{sup +} {yields} e{sup +}{gamma}, with a branching ratio sensitivity of 10{sup -13} in order to explore the parameter region predicted by many theoretical models beyond the Standard Model. The first physics run has been performed in 2008, and the second phase of data taking was carried out in 2009 after some detector upgrades. We have performed a likelihood analysis with a sensitivity of 6.1 x10{sup -12}, which is approximately twice better than the current upper limit set by the previous experiment, and set an upper limit on the branching ratio B({mu}{sup +}{yields}e{sup +}{gamma})<1.5x10{sup -11}(90%C.L.).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of head modeling errors on the spatial frequency representation of MEG

Abstract Objectives. We aim to investigate the effects of head model inaccuracies on signal and source reconstruction accuracies for various sensor array distances to the head. This allows for the assessment of the importance of head modeling for next-generation magnetoencephalography (MEG) sensors, optically-pumped magnetometers (OPM). Approach. A 1-shell boundary element method (BEM) spherical head model with 642 vertices of radius 9 cm and conductivity of 0.33 S m −1 was defined. The vertices were then randomly perturbed radially up to 2%, 4%, 6%, 8% and 10% of the radius. For each head perturbation case, the forward signal was calculated for dipolar sources located at 2 cm, 4 cm, 6 cm and 8 cm from the origin (center of the sphere), and for a 324 sensor array located at 10 cm to 15 cm from the origin. Equivalent current dipole (ECD) source localization was performed for each of these forward signals. The signal for each perturbed spherical head case was then analyzed in the spatial frequency domain, and the signal and ECD errors were quantified relative to the unperturbed case. Main results. In the noiseless and high signal-to-noise ratio (SNR) case of approximately ≥6 dB, inaccuracies in our spherical BEM head conductor models lead to increased signal and ECD inaccuracies when sensor arrays are placed closer to the head. This is true especially in the case of deep and superficial sources. In the noisy case however, the higher SNR for closer sensor arrays allows for an improved ECD fit and outweighs the effects of head geometry inaccuracies. Significance. OPMs may be placed directly on the head, as opposed to the more commonly used superconducting quantum interference device sensors which must be placed a few centimeters away from the head. OPMs thus allow for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localizations. Our results suggest that an increased emphasis on accurate head modeling for OPMs may be necessary to fully realize its improved source localization potential.

Yeo, Wan-Jin (ORCID:0000000241417123)↗

Muon polarization in the MEG experiment: predictions and measurements

The MEG experiment makes use of one of the world’s most intense low energy muon beams, in order to search for the lepton flavour violating process μ + →e + γ. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be P μ =-1 by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be P μ = -0.86 ± 0.02 (stat) $+0.05\atop{-0.06}$ (syst) at the stopping target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our μ + →e + γ search induced by the muon radiative decay: μ + →e + $\bar{v}$ μ ν e γ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment

We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, μ + → e + X,X → γγ . This search uses a dataset resulting from 7.5 × 10 14 stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009–2013. No significant excess is found in the mass region 20–45 MeV/c 2 for lifetimes below 40 ps, and we set the most stringent branching ratio upper limits in the mass region of 20–40 MeV/c 2 , down to O(10 –11 ) at 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Breakthrough MEG Technology [Slides]

LANL technology is a disruptive innovation to change market dynamics. For medical imaging experts who want to rapidly diagnose brain disorders, our LANL breakthrough MEG solution delivers faster and easier brain imaging without having to go to major urban medical centers.

59 BASIC BIOLOGICAL SCIENCES↗

Electroencephalogram (EEG) and Magnetoencephalogram (MEG) as Tools for Evaluation of Cognitive Function

We have developed computerized analysis and display techniques to help identify the origins of visually evoked scalped potentials (VESP). The potentials are recorded simultaneously from many electrodes (usually 40 to 48) spaced over the region of the scalp where appreciable evoked potentials are found in response to particular stimulus. Contour mapping algorithms are then used to display the time behavior of equipotential surfaces on the scalp during the VESP. We then use an optimization technique to select the parameters of arrays of current dipole sources within the model until the model equipotential field distribution closely fits the measured data. Computer graphics are then used to display, as a movie, the actual and model scalp potential fields and the parameters of the dipole generators within the model head during the course of VESP activity. We have devised reaction time tests that involve potentially separable stages of cognitive processing and utilize stimuli that produce measurable cognition-related features in the late component of the evoked potential. We have used these techniques to determine the loci in the brain where known cognition-related features in the evoked potential are generated and we have explored the extent to which each of these features can be related to the reaction time tasks. We have also examined the temporal-spatial aspects of their cerebral involvement. Our current work is planned to characterize the age-related changes in the processes performed by such sources. We also use a neuromagnetometer to measure the evoked magnetic fields in similar circumstances; we will discuss the relative merits of the two methodologies.

Fender, Derek H.↗