Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEASURING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measurement of the B{sup +} Production Cross Section in pp Collisions at {radical}(s)=7 TeV

Measurements of the total and differential cross sections d{sigma}/dp{sub T}{sup B} and d{sigma}/dy{sup B} for B{sup +} mesons produced in pp collisions at {radical}(s)=7 TeV are presented. The data correspond to an integrated luminosity of 5.8 pb{sup -1} collected by the CMS experiment operating at the LHC. The exclusive decay B{sup +}{yields}J/{psi}K{sup +}, with J/{psi}{yields}{mu}{sup +}{mu}{sup -}, is used to detect B{sup +} mesons and to measure the production cross section as a function of p{sub T}{sup B} and y{sup B}. The total cross section for p{sub T}{sup B}>5 GeV and |y{sup B}|<2.4 is measured to be 28.1{+-}2.4{+-}2.0{+-}3.1 {mu}b, where the first uncertainty is statistical, the second is systematic, and the last is from the luminosity measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time of Flight Electrochemistry: Diffusion Coefficient Measurements Using Interdigitated Array (IDA) Electrodes

A simple and straightforward method for measuring diffusion coefficients using interdigitated array (IDA) electrodes is reported. The method does not require that the exact electrode area be known but depends only the size of the gap between the IDA electrode pairs. Electroactive molecules produced at the generator electrode of the IDA by a voltage step or scan can diffuse to the collector electrode and the time delay before the current for the reverse electrochemical reaction is detected at the collector is used to calculate the diffusion coefficient. The measurement of the diffusion rate of Ru(NH3)6+2 in aqueous solution has been used as an example measuring diffusion coefficients using this method. Additionally, a digital simulation of the electrochemical response of the IDA electrodes was used to simulate the entire current/voltage/time behavior of the system and verify the experimentally measured diffusion coefficients. This work was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the Department of Energy, Office of Science, Office of Basic Energy Sciences.

Liu, Fei↗

Can Topology and Geometry be Measured by an Operator Measurement in Quantum Gravity?

In the context of LLM geometries, we show that superpositions of classical coherent states of trivial topology can give rise to new classical limits where the topology of spacetime has changed. We argue that this phenomenon implies that neither the topology nor the geometry of spacetime can be the result of an operator measurement. We address how to reconcile these statements with the usual semiclassical analysis of low energy effective field theory for gravity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Measurement of the Anomalous Magnetic Moment of the Muon at Fermilab

The anomalous magnetic moment of the muon is one of the most precisely measured quantities in experimental particle physics. Its latest measurement at Brookhaven National Laboratory deviates from the Standard Model expectation by approximately 3.5 standard deviations. The goal of the new experiment, E989, now under construction at Fermilab, is a fourfold improvement in precision. Here in this article, we discuss the details of the future measurement and its current status.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the {sup 8}B solar neutrino flux with the KamLAND liquid scintillator detector

We report a measurement of the neutrino-electron elastic scattering rate from {sup 8}B solar neutrinos based on a 123 kton-day exposure of KamLAND. The background-subtracted electron recoil rate, above a 5.5-MeV analysis threshold is 1.49 {+-} 0.14(stat) {+-} 0.17(syst) events per kton-day. Interpreted as due to a pure electron flavor flux with a {sup 8}B neutrino spectrum, this corresponds to a spectrum integrated flux of 2.77 {+-} 0.26(stat) {+-} 0.32(syst) x10{sup 6} cm{sup -2}s{sup -1}. The analysis threshold is driven by {sup 208}Tl present in the liquid scintillator, and the main source of systematic uncertainty is due to background from cosmogenic {sup 11}Be. The measured rate is consistent with existing measurements and with standard solar model predictions which include matter-enhanced neutrino oscillation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of differential cross sections of top quark pair production in association with jets in pp collisions at $\sqrt{s}=13 $ TeV using the ATLAS detector

Measurements of differential cross sections of top quark pair production in association with jets by the ATLAS experiment at the LHC are presented. The measurements are performed as functions of the top quark transverse momentum, the transverse momentum of the top quark-antitop quark system and the out-of-plane transverse momentum using data from pp collisions at s√=13 TeV collected by the ATLAS detector at the LHC in 2015 and corresponding to an integrated luminosity of 3.2 fb -1 . The top quark pair events are selected in the lepton (electron or muon) + jets channel. The measured cross sections, which are compared to several predictions, allow a detailed study of top quark production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved measurements of the hot-electron population in ignition-scale experiments on the National Ignition Facility (invited)

In laser-driven inertial confinement fusion, hot electrons can preheat the fuel and prevent fusion-pellet compression to ignition conditions. Measuring the hot-electron population is key to designing an optimized ignition platform. The hot electrons in these high-intensity, laser-driven experiments, created via laser-plasma interactions, can be inferred from the bremsstrahlung generated by hot electrons interacting with the target. At the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 43, 2841 (2004)], the filter-fluorescer x-ray (FFLEX) diagnostic–a multichannel, hard x-ray spectrometer operating in the 20–500 keV range–has been upgraded to provide fully time-resolved, absolute measurements of the bremsstrahlung spectrum with ∼300 ps resolution. Initial time-resolved data exhibited significant background and low signal-to-noise ratio, leading to a redesign of the FFLEX housing and enhanced shielding around the detector. The FFLEX x-ray sensitivity was characterized with an absolutely calibrated, energy-dispersive high-purity germanium detector using the high-energy x-ray source at NSTec Livermore Operations over a range of K-shell fluorescence energies up to 111 keV (U K{sub β}). The detectors impulse response function was measured in situ on NIF short-pulse (∼90 ps) experiments, and in off-line tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of high-dynamic range x-ray Thomson scattering spectra for the characterization of nano-plasmas at LCLS

Atomic clusters can serve as ideal model systems for exploring ultrafast (∼100 fs) laser-driven ionization dynamics of dense matter on the nanometer scale. Resonant absorption of optical laser pulses enables heating to temperatures on the order of 1 keV at near solid density conditions. To date, direct probing of transient states of such nano-plasmas was limited to coherent x-ray imaging. Here we present the first measurement of spectrally resolved incoherent x-ray scattering from clusters, enabling measurements of transient temperature, densities, and ionization. Single shot x-ray Thomson scattering signals were recorded at 120 Hz using a crystal spectrometer in combination with a single-photon counting and energy-dispersive pnCCD. A precise pump laser collimation scheme enabled recording near background-free scattering spectra from Ar clusters with an unprecedented dynamic range of more than 3 orders of magnitude. Such measurements are important for understanding collective effects in laser-matter interactions on femtosecond time scales, opening new routes for the development of schemes for their ultrafast control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Measurement of Gravitational Lensing of the Cosmic Microwave Background by Galaxy Clusters Using Data from the South Pole Telescope

Clusters of galaxies are expected to gravitationally lens the cosmic microwave background (CMB) and thereby generate a distinct signal in the CMB on arcminute scales. Measurements of this effect can be used to constrain the masses of galaxy clusters with CMB data alone. Here we present a measurement of lensing of the CMB by galaxy clusters using data from the South Pole Telescope (SPT). We also develop a maximum likelihood approach to extract the CMB cluster lensing signal and validate the method on mock data. We quantify the effects on our analysis of several potential sources of systematic error and find that they generally act to reduce the best-fit cluster mass. It is estimated that this bias to lower cluster mass is roughly 0.85σ in units of the statistical error bar, although this estimate should be viewed as an upper limit. Furthermore, we apply our maximum likelihood technique to 513 clusters selected via their Sunyaev–Zeldovich (SZ) signatures in SPT data, and rule out the null hypothesis of no lensing at 3.1σ. The lensing-derived mass estimate for the full cluster sample is consistent with that inferred from the SZ flux: M 200,lens = 0.83 +0.38 -0.37 M 200,SZ (68% C.L., statistical error only).

79 ASTRONOMY AND ASTROPHYSICS↗

Fabrication of large dual-polarized multichroic TES bolometer arrays for CMB measurements with the SPT-3G camera

This paper presents the procedures used by Argonne National Laboratory to fabricate large arrays of multichroic transition-edge sensor (TES) bolometers for cosmic microwave background (CMB) measurements. These detectors will be assembled into the focal plane for the SPT-3G camera, the third generation CMB camera to be installed in the South Pole Telescope. The complete SPT-3G camera will have approximately 2690 pixels, for a total of 16,140 TES bolometric detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a Nb microstrip line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES bolometers. There are six TES bolometer detectors per pixel, which allow for measurements of three band-passes (95 GHz, 150 GHz and 220 GHz) and two polarizations. The steps involved in the monolithic fabrication of these detector arrays are presented here in detail. Patterns are defined using a combination of stepper and contact lithography. The misalignment between layers is kept below 200 nm. The overall fabrication involves a total of 16 processes, including reactive and magnetron sputtering, reactive ion etching, inductively coupled plasma etching and chemical etching.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of e p → e ' π + π – p ' cross sections with CLAS at 1.40 GeV < W < 2.0 GeV and 2.0 GeV 2 < Q 2 < 5.0 GeV 2

This study reports new exclusive cross sections for ep→e'π + π – p' using the CLAS detector at Jefferson Laboratory. These results are presented for the first time at photon virtualities 2.0 GeV 2 < Q 2 < 5.0 GeV 2 in the center-of-mass energy range 1.4 GeV < W < 2.0 GeV, which covers a large part of the nucleon resonance region. Using a model developed for the phenomenological analysis of electroproduction data, we see strong indications that the relative contributions from the resonant cross sections at W < 1.74 GeV increase with Q 2 . These data considerably extend the kinematic reach of previous measurements. Exclusive ep→e'π + π – p' cross section measurements are of particular importance for the extraction of resonance electrocouplings in the mass range above 1.6 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of branching fractions, polarizations, and direct CP-violation asymmetries in B -> rho0 K* and B -> f0(980) K* decays

We present measurements of the branching fractions, longitudinal polarization, and direct CP-violation asymmetries for the decays B{sup +} {yields} {rho}{sup 0}K*{sup +} and B{sup +} f{sub 0}(980)K*{sup +} with a sample of (467 {+-} 5) x 10{sup 6} B{bar B} pairs collected with the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the SLAC National Accelerator Laboratory. We observe B{sup +} {yields} {rho}{sup 0}K*{sup +} with a significance of 5.3{sigma} and measure the branching fraction {Beta}(B{sup +} {yields} {rho}{sup 0}K*{sup +}) = (4.6 {+-} 1.0 {+-} 0.4) x 10{sup -6}, the longitudinal polarization f{sub L} = 0.78 {+-} 0.12 {+-} 0.03, and the CP-violation asymmetry A{sub CP} = 0.31 {+-} 0.13 {+-} 0.03. We observe B{sup +} {yields} f{sub 0}(980)K*{sup +} and measure the branching fraction {Beta}(B{sup +} {yields} f{sub 0}(980)K*{sup +}) x {Beta}(f{sub 0}(980) {yields} {pi}{sup +}{pi}{sup -}) = (4.2 {+-} 0.6 {+-} 0.3) x 10{sup -6} and the CP-violation asymmetry A{sub CP} = -0.15 {+-} 0.12 {+-} 0.03. The first uncertainty quoted is statistical and the second is systematic.

43 PARTICLE ACCELERATORS↗

First observation of radiative B⁰ → ΦK⁰γ decays and measurements of their time-dependent CP violation

We report the first observation of the radiative decay B⁰→ ΦK⁰γ using a data sample of 772 × 10⁶ BB¯ pairs collected at the (4S) resonance with the Belle detector at the KEKB asymmetric-energy e⁺e⁻ collider. We observe a signal of 37 ± 8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is B(B⁰→ ΦK⁰γ) = (2.74±0.60±0.32)×10⁻⁶, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP-violation parameters: S ΦK⁰ S γ = +0.74 ⁺0.72 –1.05 (stat) +0.10 –0.24 (syst) and A ΦK⁰ S γ = +0.35 ± 0.58(stat) +0.23 –0.10 (syst). Furthermore, we measure B(B⁺ → ΦK⁺γ) = (2.48 ± 0.30 ± 0.24) × 10⁻⁶, ACP = –0.03 ± 0.11 ± 0.08 and find that the signal is concentrated in the M ΦK mass region near threshold.

Sahoo, Himansu B.↗