Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Iterative and function-continuation Fourier deconvolution methods for enhancing mass spectrometer resolution

Mass spectrometer data in the form of ion current versus mass-to-charge ratio often include overlapping mass peaks, especially in low- and medium-resolution instruments. Numerical deconvolution of such data effectively enhances the resolution by decreasing the overlap of mass peaks. In this paper two approaches to deconvolution are presented: a function-domain iterative technique and a Fourier transform method which uses transform-domain function-continuation. Both techniques include data smoothing to reduce the sensitivity of the deconvolution to noise. The efficacy of these methods is demonstrated through application to representative mass spectrometer data and the deconvolved results are discussed and compared to data obtained from a spectrometer with sufficient resolution to achieve separation of the mass peaks studied. A case for which the deconvolution is seriously affected by Gibbs oscillations is analyzed.

Ioup, J. W.↗

Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures

The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

Polychlorinated Biphenyls/analysis/metabolism↗

Compound classification by computer treatment of low resolution mass spectra - Application to geochemical and environmental problems.

A description is given of a development of computer analysis of low-resolution chromatographic-mass spectrometric data, which provides a preliminary classification of an unknown spectrum as a listing of candidate classes of compounds. This procedure, referred to as COMSOC (Classification of Mass Spectra on Computers), operates by converting an incoming unknown mass spectrum into a simplified key word which is then compared with each of the key words held in its reference file. The advantages of COMSOC in characterizing complex mixtures are emphasized.

Smith, D. H.↗

High mass resolution isochronous time-of-flight spectrograph for three-dimensional space plasma measurements

By combining a toroidal electrostatic analyzer with a novel cylindrically symmetric isochronous time-of-flight mass spectrometer, an instrument was developed that simultaneously determines the three-dimensional distribution function of ions and differentiates species. The ion mass is determined to high resolution (M/Delta-M greater than 50) from the time of flight within a harmonic field configuration defined by hyperboloid equipotential surfaces. A second conventional time-of-flight channel makes use of particles leaving the thin entrance foil as neutrals. An additional solid state detector in which the neutrals are stopped allows the total energy and thereby the ionic charge of the incident ions to be determined as well. Information from the neutral and the ion channels can be combined to determine the total mass of an incident molecular ion and the mass of one atomic fragment.

Moebius, E.↗

High-Spatial-Resolution Mass Rates From GRACE and GRACE-FO: Global and Ice Sheet Analyses

GRACE and GRACE-FO gravimetry data are unique in its ability to observe global water mass variability and has frequently been applied for the determination of global mass rates to quantify the impacts of climate change and human activity on global freshwater availability and land ice evolution. However, its relatively coarse spatial resolution of ∼300-500 km at monthly intervals precludes its direct use to measure mass changes in smaller drainage basins and individual glacier systems. We present a new global high resolution mascon product that improves spatial resolution and signal recovery by estimating trends directly from more than 16 years of Level 1B GRACE and GRACE-FO data. We compare this product to independent gravimetry spherical harmonic trend estimates and to ice sheet mass rates derived from ICESat and ICESat-2 laser altimetry. We demonstrate enhanced global signal recovery and improved agreement with ICESat/ ICESat-2 and discuss likely causes for the remaining discrepancies between the gravimetry and laser altimetry solutions.

Bryant D. Loomis↗

FUN with PANURGE - High mass resolution ion microprobe measurements of Mg in Allende inclusions

Isotopic ratios have been determined, at a precision level approaching that of counting statistics using beam switching, by employing PANURGE, a modified CAMECA IMS3F ion microprobe at a mass resolving power of 5000. This technique is used to determine the isotopic composition of Mg and Si and the atomic ratio of Al/Mg in minerals from the Allende inclusion WA and the Allende FUN inclusion C1. Results show enrichment in Mg-26 of up to 260 percent. Results of Mg and Al/Mg measurements on cogenetic spinel inclusion and host plagiclase crystals show Mg-Al isochrons in excellent agreement with precise mineral isochrons determined by thermal emission mass spectrometry. The measurements are found to confirm the presence of substantial excess Mg-26 in WA and its near absence in C1. Data is obtained which indicates a metamorphic reequilibrium of Mg in Allende plagioclase at least 0.6 my after WA formation. Ion probe measurements are obtained which confirm that the Mg composition in Allende C1 is highly fractionated and is uniform among pyroxene, melilite, plagioclase, spinel crystals, and spinel included in melilite and plagioclase crystals.

Huneke, J. C.↗

Analysis of low resolution mass spectra

Computer program determines gas constituents from measurements of mass/peak-height spectrum from residual gas analyzer. Applications of program include residual gas analysis for work in space environmental simulators, space environment contamination, and air pollution monitoring.

Babst, R. W.↗

Organic contamination analysis: High resolution mass spectrometric analysis of surface organics on selected areas of Surveyor 3

The mirror and middle shroud were extracted for organics by washing the surfaces with solvents. The techniques are discussed. Ion microprobe analyses of the primarily atomic species are presented. The sources of the organic contaminants are: (1) hydrocarbons from lubricating oils and general terrestrial contamination, (2) dioctyl phthalate, probably from polyethylene bagging material (the plasticizer), (3) carboxylic acids from decomposition of grease and general terrestrial contamination, (4) silicones from sources such as lubricating oil, (5) outgassing of electronics and plasticizer, (6) vinyl alcohol and styrene copolymer, probably from electronic insulation, and (7) nitrogenous compounds from the lunar module and possibly Surveyor 3 engine exhaust.

Simoneit, B. R.↗

High-resolution mass spectrometry of nitrogenous compounds of the Colorado Green River formation oil shale.

Basic nitrogenous compounds isolated from extracts of Green River Formation oil shale were analyzed. The major homologous constituents found were the compositional types - namely, quinolines, tetrahydrequinolines with minor amounts of pyridines and indoles series and traces of more aromatized nitrogen compounds. These results are correlated with nitrogen compounds isolated from Green River Formation retort oil and are a survey of the unaltered nitrogen compounds indigeneous to the shale.

Simoneit, B. R.↗