Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nuclear magnetic resonance investigation of superconducting and normal state Nb 3 Sn

The superconductor Nb3Sn has important applications for construction of very high-field superconducting magnets. In this work we investigate its microscopic electronic structure with 93 Nb nuclear magnetic resonance (NMR). The high-quality Nb 3 Sn powder sample was studied in both 3.2 T and 7 T magnetic fields in the temperature range from 4 K to 300 K. From measurement of the spectrum and its theoretical analysis, we find evidence for anisotropy despite its cubic crystal structure. Magnetic alignment of the powder grains in the superconducting state was also observed. The Knight shift and spin-lattice relaxation rate, T 1 -1 , were measured and the latter compared with BCS theory for the energy gap Δ(0) = 2.7 ± 0.3k B T c at 3.2 T and Δ(0) = 2.33 ± 0.07 k B T c at 7 T, indicating suppression of the order parameter by magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE

Detecting rare earth elements via optically detected magnetic resonance (ODMR) and spin-relaxometry using nitrogen vacancy centers in nanodiamonds

Nanodiamonds embedded with nitrogen-vacancy (NV) centers are emerging as powerful tools in quantum sensing due to their remarkable sensitivity to local variations in electromagnetic fields, temperature, and pressure. These point defects in the diamond lattice can be probed using optically detected magnetic resonance (ODMR) and spin relaxometry techniques, allowing for the detection and characterization of magnetic nanoparticles and ions. The sensing mechanism relies on laser-induced excitation of the NV center's non-degenerate triplet ground state, which promotes electrons to an excited state. Subsequent photoluminescence (PL) emission, which is spin-state dependent, is then measured. These spin states are highly responsive to magnetic perturbations in the surrounding environment. By analyzing changes in the ODMR spectra and spin relaxation times, we can effectively monitor how magnetic species influence the NV center's spin dynamics, thus enabling sensitive and selective characterization of nanoscale magnetic materials. These techniques have been applied for the characterization of transition metals and rare earth elements which shows natural ferromagnetic properties.

magnetic nanopartgicles and ions

A Field-Deployable Magnetic Resonance Imaging Rhizotron for Modeling and Enhancing Root Growth and Biogeochemical Function

A collaborative team from Texas A&M AgriLife Research, ABQMR Inc., the Soil Health Institute, the Athinoula A. Martinos Center for Biomedical Imaging, and NIST developed low-field magnetic resonance imaging (LF-MRI) instrumentation capable of imaging intact soil-root systems. The system measured root biomass, architecture, 3D mass distribution, and growth rates, providing a non-destructive means to evaluate ideal plant characteristics based on root metrics. It also successfully generated three-dimensional images of soil water content, a key property influencing root growth and exploration. Operating much like an MRI used in a medical setting, the system functioned in field conditions without damaging plants, overcoming the limitations of traditional methods such as trenching, soil coring, and root excavation. Over the course of the project, the team designed and built three functional prototype systems. These prototypes provided new insights into root–water–soil interactions that drive processes such as nutrient uptake, water use, and carbon management. This information contributed to efforts to optimize plants for carbon sequestration without sacrificing economic yield. The project also supported the identification of desirable traits for energy sorghum, including high root growth rates, more vertical root angles, and enhanced drought resilience under water-limiting conditions.

09 BIOMASS FUELS

Characterization of dangling bond defects at the crystalline Si/SiO x interface in a polycrystalline Si passivating contact solar cell at room temperature with electrically detected magnetic resonance spectroscopy

Monocrystalline silicon solar cells can achieve photoconversion efficiencies exceeding 26%; however, performance-limiting defects that trap carriers continue to be a challenge. In this work, we have characterized Si solar cells with tunneling SiO x /polycrystalline-Si (poly-Si) passivating contacts (TOPCon) on As-doped Czochralski Si wafers with electrically detected magnetic resonance (EDMR) spectroscopy. We fabricated 2 × 20 mm 2 TOPCon-like mini solar cells with edge passivation alongside larger 4 cm 2 sister cells and obtained similar device characteristics. We performed EDMR spectroscopy at 300 K on two minicells with different degrees of surface passivation based on the recombination parameter, J o , values of 40 and 310 fA/cm2. We optimized the resolution and the signal-to-noise ratio of the EDMR response of the minicells by varying the forward bias voltage and the magnetic field modulation amplitude. We detect two distinct signals with EDMR spectroscopy, an axial-like signal at g = 2.009, 2.0087, and 2.0015, and an isotropic signal at g = 2.0024, which we attribute to Si dangling bonds (P b0 and P b centers) and boron–oxygen related defects, respectively, at or near the c-Si/SiO x interface. The EDMR signals were lower for the cell with a lower value of J o , while the ratio of the two defect populations was very similar. The EDMR signal increases with forward bias but drops to zero at bias voltages >0.5 V, consistent with interface defects within or near the boron-doped emitter depletion region. Our study demonstrates a method to fabricate minicells that can be characterized with EDMR spectroscopy to detect industrially relevant defects in TOPCon cells.

14 SOLAR ENERGY

Multimode turbulent flow measurements using magnetic resonance imaging- and laser-based techniques and computational fluid dynamics simulations

We studied the flow field characteristics of a turbulent flow over a regularized cube array with a perpendicular injection flow through the floor between the second and third cubical elements, representing the complex flow interactions of a 3D jet and the wake flows behind cubical obstacles. Four different experimental measurements were performed: two magnetic resonance imaging-based measurements for three-dimensional three-component velocity (MRV) and concentration (MRC) and two laser-based techniques, particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF), for two-dimensional two-component velocity and concentration measurement, respectively. The mainstream Reynolds number is Re = 15 000⁠, based on the primary inlet velocity U m and channel height D H ⁠, whereas the injector Reynolds number is Re j = 3400⁠, based on the injector velocity U j and the injector's exit width D j ⁠. Numerical simulations were performed for the studied flow configuration of turbulent flow over a regularized cube array using Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulation (LES) approaches. Results obtained from experimental measurements—including MRV, MRC, PIV, and PLIF—as well as RANS and LES simulations are discussed and compared along several horizontal and vertical planes of the studied configuration. In addition, 3D turbulent flow structures, such as leading-edge vortex, horseshoe vortex, and jet shear-layer vortex, and the isosurfaces of scalar concentration successfully revealed by MRV and MRC techniques were found to be in very good agreement with those 3D features extracted from RANS and LES simulations. In conclusion, the high-resolution experimental and numerical database obtained from this study could be useful for validation and verification of numerical codes.

Computational fluid dynamics

Nuclear magnetic resonance dark-matter searches are sensitive to dark photons and the axion-photon coupling

We demonstrate that nuclear magnetic resonance based searches for dark matter (DM) have intrinsic and powerful sensitivity to dark photons and the axion-photon coupling. The reason is conceptually straightforward. An instrument such as CASPEr-Gradient begins with a large sample of nuclear spins polarized in a background magnetic field. In the presence of axion DM coupled to nucleons, the spin ensemble feels an effective magnetic field 𝐁 ∝ ∇𝑎 that tilts the spins, generating a potentially observable precession. If the magnetic field is real rather than effective, the system responds identically. A real field can be generated by a kinetically mixed dark photon within the shielded region the sample is placed or an axion coupled to photons through its interaction with the background magnetic field. We show that all three signals are detectable and distinguishable. If CASPEr-Gradient were to reach the QCD axion prediction of the axion-nucleon coupling, it would simultaneously be sensitive to kinetic mixings of 𝜀 ≃ 3 × 10 −16 and axion-photon couplings of 𝑔 𝑎⁢𝛾⁢𝛾 ≃ 2 × 10 −16 GeV −1 for 𝑚 ≃ 1 𝜇⁢eV. Our analysis demonstrates that CASPEr-Gradient has the tantalizing possibility of simultaneously measuring two separate couplings of axion dark matter, thereby providing a unique window into the axion’s UV completion.

Beadle, Carl [University of Geneva (Switzerland)]

Readout of Oriented Triplet Excitons in Linear Acenes via Room-Temperature Electrically Detected Magnetic Resonance

In this study, optically generated molecular spin centers offer an attractive platform for room-temperature spintronic and quantum applications. The linear acene family of molecules are especially good candidates due to their efficient generation of highly polarized triplet excitons via singlet fission. However, the direct detection and manipulation of these spin centers in thin films via the electrical means desirable for ultimate microelectronic devices has proven challenging. In particular, highly oriented triplet features have previously been detected in crystalline anthracene but longer acenes reveal only doublet features in Electrically-Detected Magnetic Resonance (EDMR). In this work we present EDMR spectra of highly oriented triplet excitons in pentacene for the first time, using a host-guest style device made of tetracene and pentacene. The guest acts as an energetic trap site, permitting the isolation and detection of molecular triplets at room temperature. Modeling of these results shows that the observed resonance features correspond to triplet sublevel transitions on isolated pentacene guest molecules. Rotation of the applied field confirms the tendency of the linear acenes to self-orient with the longest molecular axis perpendicular to the device substrate. Lastly, we find the disappearance of resonant triplet features in the neat acenes is not primarily due to the effects of exciton delocalization, but a broader mechanism of spin relaxation primarily influenced by exciton diffusivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Surface Terminations of LaAlO 3 Perovskite Nanoparticles as Viewed by Solid-State Nuclear Magnetic Resonance

Nanocrystal surfaces generally undergo reconstructions that differentiate them from the bulk structures, often in nontrivial ways. Understanding these terminations is critical across diverse fields, from heterogeneous catalysis to the formation of topological states and the synthesis of semiconductor nanomaterials. Determining surface structures is currently an interdisciplinary task, most often involving high-resolution electron microscopy and surface electron diffraction. These methods, however, do not provide a global view of the ensemble of structures present in a sample. Here, we show how surface-sensitive solid-state nuclear magnetic resonance (SSNMR) spectroscopy methods can bridge this gap. In this context, we investigated the surface structure of lanthanum aluminate (LaAlO 3 ) perovskite nanoparticles. Four distinct surface terminations have previously been observed for this material, but their relative abundances were unknown. Using an array of double- and triple-resonance SSNMR methods probing the relative proximities of surface 1 H, 27 Al, 17 O, and 139 La nuclei, we conclude the surface to be majority terminated (80%) by AlO x with substantial (20%) LaO x terminated regions.

Materials

Evaluation of hydrogen storage in sandstone reservoirs using 1 H nuclear magnetic resonance spectroscopy

Evaluation of the hydrogen storage capacity of porous rocks is crucial for underground hydrogen storage. Using 1 H nuclear magnetic resonance (NMR) spectroscopy, we successfully characterized the hydrogen responses and identified storage mechanisms in Berea sandstone under varying water saturation. Here, the results indicate that the injected hydrogen behaves as a free gas phase and is capable of occupying the empty pore volume regardless of the saturation state. No hysteresis was observed during injection and production cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Structural Studies of Alloyed and Nanoparticle Transition Metal Dichalcogenides by Selenium-77 Solid-State Nuclear Magnetic Resonance Spectroscopy

Layered transition metal dichalcogenides (TMDCs) such as MoS 2 , MoSe 2 , and WSe 2 are under intense investigation because they are atomically thin semiconductors with photophysical properties that can be tuned by changing their composition or morphology. Mechanochemical processing has been proposed as a method to obtain alloyed TMDCs in the series Mo 1–x W x S y Se 2–y (x = 0–1; y = 0–2). However, elucidating the chemical transformations occurring at the atomic scale following mechanochemical processing can be challenging because the products are often amorphous or microcrystalline. To address this challenge, we probe TMDC mixing and alloying by using a combination of powder X-ray diffraction, Raman spectroscopy, diffuse reflectance spectroscopy, 77 Se solid-state nuclear magnetic resonance (SSNMR) spectroscopy, and planewave density functional theory (DFT) calculations. The nature of the milling material and reaction atmosphere are shown to be essential factors in limiting the formation of undesired oxide byproducts. We demonstrate acquisition of 77 Se SSNMR spectra using different combinations of Carr-Purcell Meiboom-Gill acquisition (CPMG) pulse sequences, magic angle spinning (MAS), and MAS dynamic nuclear polarization. Further, the combination of SSNMR with the other characterization methods clearly demonstrates that high energy impact ball milling induces molecular level alloying of Mo, W and chalcogen atoms in the family Mo 1–x W x S y Se 2–y . Gauge including projector augmented wave DFT calculations yield accurate 77 Se chemical shift (CS) tensor components. 77 Se SSNMR spectroscopy was also applied to study the structure of WSe 2 nanocrystals intercalated with ethylenediamine. The intercalated WSe 2 nanocrystals exhibit a more positive isotropic 77 Se CS as compared to bulk WSe 2 , however, the 77 Se CS anisotropy is the same, confirming the WSe 2 layers have a similar structure as in their bulk counterparts.

36 MATERIALS SCIENCE

Investigation of the Suppression of Edge Localized Modes by Resonant Magnetic Perturbations in NSTX/NSTX-U (Final Technical Report)

The purpose of the grant was to investigate the suppression of edge localized modes by resonant magnetic perturbations in both NSTX and NSTX-U. Unfortunately, the project quickly exhausted all of the relevant experimental data from NSTX. It was originally intended to use new data from NSTX-U, when it restarted. However, the considerable delay in the restart made this impossible. Hence, with the permission of DOE, the grant was pivoted toward a more general examination of the MHD stability of tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Determining hexavalent chromium transport properties in alkaline nuclear waste using nuclear magnetic resonance spectroscopy

This study focuses on the transport properties of hexavalent chromium, specifically the chromate anion, to improve predictive models and environmental remediation strategies for Cr(VI) migration. Using 53 Cr Nuclear Magnetic Resonance (NMR) spectroscopy, the research quantifies chromate in multicomponent electrolytes replicating nuclear waste conditions at the Hanford Site in Washington State. The consistency of the 53 Cr NMR signal integral with chromate concentration, despite varying matrix compositions, establishes it as a reliable concentration indicator. The transport properties of chromate in an alkaline solution were assessed using relaxation-based measurements via saturation recovery and Carr-Purcell-Meiboom-Gill experiments, determining spin-lattice and spin-spin relaxation times. These measurements, combined with the Bloembergen-Purcell-Pound equation, helped estimate the rotational correlation time and the 53 Cr self-diffusion coefficient using Stokes-Einstein-Debye and Stokes-Einstein equations. Direct measurements were obtained through pulsed field gradient stimulated echo 53 Cr NMR spectroscopy. Monte Carlo simulations further estimated uncertainty propagation. The results enhance comprehension of chromate transport and highlight prospects for identifying transport properties of NMR-active nuclei, traditionally considered unreachable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Enhancing the Optically Detected Magnetic Resonance Signal of Organic Molecular Qubits

In quantum information science and sensing, electron spins are often purified into a specific polarization through an optical-spin interface, a process known as optically detected magnetic resonance (ODMR). Diamond-NV centers and transition metals are both excellent platforms for these so-called color centers, while metal-free molecular analogues are also gaining popularity for their extended polarization lifetimes, milder environmental impacts, and reduced costs. In our earlier attempt at designing such organic high-spin π-diradicals, we proposed to spin-polarize by shelving triplet M S = ±1 populations as singlets. This was recently verified by experiments albeit with low ODMR contrasts of <1% at temperatures above 5 K. In this work, we propose to improve the ODMR signal by moving singlet populations back into the triplet M S = 0 sublevel, designing a true carbon-based molecular analogue to the NV center. Our proposal is based upon transition-orbital and group-theoretical analyses of beyond-nearest-neighbor spin–orbit couplings, which are further confirmed by ab initio calculations of a realistic trityl-based radical dimer. Microkinetic analyses point toward high ODMR contrasts of around 30% under experimentally feasible conditions, a stark improvement from previous works. Finally, in our quest toward ground-state optically addressable molecular spin qubits, we exemplify how our symmetry-based design avoids Zeeman-induced singlet–triplet mixings, setting the scene for realizing electron spin qubit gates.

Group theory

High fidelity simulations of contaminant dispersion in an urban environment with comparison to magnetic resonance imaging measurements

The dispersion of a contaminant in an urban environment has the potential to impact a large population of people. In this work, a complex urban canopy flow based on the Oklahoma City downtown business district circa 2003 is studied using Magnetic Resonance Imaging (MRI) and high-fidelity Large Eddy Simulations (LES). MRI is a novel experimental technique that can provide high-resolution measurements in four dimensions (three spatial and temporal) for lab scale models. The experiments and simulations use the same geometry and boundary conditions providing a one-to-one comparison of the two methods. Results are presented on the time-averaged velocity and concentration fields, the temporal dynamics of the concentration plumes for a transient release, and a novel Cloud Identification Algorithm that can separate plumes produced by periodic contaminant releases used for ensemble averaging over many releases. The MRI and LES datasets both include millions of measurement voxels and the comparisons highlight the complex 3D nature of the flow including strong vertical velocities in spanwise street canyons and flow acceleration in streamwise street canyons. The concentration fields are qualitatively similar albeit the LES shows larger dispersion. A quantitative analysis with performance measures compares the datasets pointwise and demonstrates that the two 3D datasets are similar with respect to many measures including a fractional bias of 0.02 (ideal=0.0), correlation coefficient of 0.87 (ideal = 1.0), and the fraction points within a factor of 2 is 0.98 (ideal = 1.0). Plume analysis compares the arrival and residence time of contaminant and is found to vary significantly with location within the urban environment with arrival times between 0 and 1.25 and differences within the contaminant cloud less than 10% at most locations.

54 ENVIRONMENTAL SCIENCES

Dynamics of fluorinated imide-based ionic liquids using nuclear magnetic resonance techniques

There is increasing interest in studying molecular motions in ionic liquids to gain better insights into their transport properties and to expand their applications. Here, in this study, we have employed the fast field cycling relaxometry and pulsed field gradient nuclear magnetic resonance techniques to investigate the rotational and translational dynamics of fluorinated imide-based ionic liquids (ILs) at different temperatures. We have studied a total of six ILs composed of the 1-butyl-3-methylimidazolium cation ([BMIM] + ) combined with chemically modified analogs of the bis((trifluoromethyl)sulfonyl)imide anion ([NTf 2 ] − or [TFSI] − ). The primary objective of this paper is to broaden the understanding of how the anion's conformational flexibility, fluorination, and mass affect the molecular dynamics of cations and anions. Our results indicate that flexibility has the most significant impact on the rotational and translational motions of ions. Meanwhile, the effect of fluorination and mass is only relevant when conformational flexibility does not change significantly between the ILs being compared.

25 ENERGY STORAGE

Role of Nematic Fluctuations on Superconductivity in FeSe 0.47 ⁢Te 0.53 Revealed by Nuclear Magnetic Resonance under Pressure

The relationship between antiferromagnetic (AFM) spin fluctuations (SF), nematic fluctuations, and superconductivity (SC) has been central to understanding the pairing mechanism in iron-based superconductors (IBSCs). Iron chalcogenides, which hold the simplest crystal structure in IBSCs, provide a good platform to investigate the relationship. Here, we report 77 Se and 125 Te nuclear magnetic resonance studies of FeSe 0.47⁢ Te 0.53 , which is located close to a nematic quantum critical point (QCP), under pressures up to 1.35 GPa. Further, both the superconducting critical temperature and AFMSF were found to be enhanced under pressure, which suggests a correlation between SC and AFMSF in FeSe 0.47 ⁢Te 0.53 . However, the contribution of AFMSF to SC in FeSe 0.47 ⁢Te 0.53 was found to be much less compared to that in FeSe 1−𝑥 ⁢S 𝑥 , suggesting that nematic fluctuations play a dominant role in the SC in FeSe 1−𝑥⁢ Te 𝑥 around the nematic QCP.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND