Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MAGNETIC CIRCUIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Flattening the Field during Injection in the Fermilab Booster using Dipole Corrector Magnets

The FNAL Booster is a fast cycling 15 Hz resonant circuit synchrotron accelerating proton beam from 400 MeV to 8 GeV. The linac pulse injected into the Booster is ˜32 usec long and fills the ring by multi-turn charge-exchange injection. As part of the PIP-II project, the Booster injection energy and repetition rate will be increased to 800 MeV and 20 Hz respectively. Due to much reduced average current in the new superconducting PIP-II linac, the injection time will increase to 550us. A shorter machine cycle coupled to a longer injection time make flattening the injection porch B-field during injection important requirement for successful PIP-II operation. We aim to achieve: (1) flattening of the net bending during injection using dipole correctors, and (2) using a new system based on an Altera FPGA board, reduction of the cycle-to-cycle bending field variation caused by current jitter in the Gradient Magnet Power Supply (GMPS). While the flat injection scheme is essential to future PIP-II operations, it should also noticeably improve efficiency for present HEP operations.

43 PARTICLE ACCELERATORS

Flattening the field during injection in the Fermilab booster using dipole corrector magnets

The FNAL Booster is a fast cycling 15 Hz resonant circuit synchrotron accelerating proton beam from 400 MeV to 8 GeV. The linac pulse injected into the Booster is ~32 μsec long and fills the ring by multi-turn charge-exchange injection. As part of the PIP-II project, the Booster injection energy and repetition rate will be increased to 800 MeV and 20 Hz respectively. Due to much reduced average current in the new superconducting PIP-II linac, the injection time will increase to 550 μs. A shorter machine cycle coupled to a longer injection time make flattening the injection porch B-field during injection important requirement for successful PIP-II operation. We aim to achieve: (1) flattening of the net bending during injection using dipole correctors, and (2) using a new system based on an Altera FPGA board, reduction of the cycle-to-cycle bending field variation caused by current jitter in the Gradient Magnet Power Supply (GMPS). While the flat injection scheme is essential to future PIP-II operations, it should also noticeably improve efficiency for present HEP operations.

43 PARTICLE ACCELERATORS

Magnetometry in a diamond anvil cell using nitrogen vacancy centers in a nanodiamond ensemble

The emerging field of optical magnetometry utilizing negative-charged nitrogen vacancy (NV – ) centers provides a highly sensitive lab bench technique for spatially resolved physical property measurements. Their implementation in high pressure diamond anvil cell (DAC) environments will become common as other techniques are often limited due to the spatial constraints of the sample chamber. Apparatus and techniques are described here permitting for more general use of magnetic field measurements inside a DAC using continuous wave optical detected magnetic resonance in NV – centers in a layer of nanodiamonds. A microstrip antenna delivers a uniform microwave field to the DAC and is compatible with simple metal gaskets, and the sensor layer of deposited nanodiamonds allows for simple determination of the magnetic field magnitude for B in the 1–100 G range. The ferromagnetic transition in iron at 18 GPa is measured with the apparatus, along with its hysteretic response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Integrated Magnetics for Multiport Inductive and Conductive Power Transfer Architecture for Electric Vehicles

This paper proposes a shared magnetic arrangement for an electric-vehicle charger that supports both conductive and inductive charging while preserving independent power control at the two ports. In the proposed implementation, the high-frequency transformer used for the conductive path and the resonant inductor required by the inductive path are realized in an integrated form. By combining the magnetic structure and primary-side converter hardware, the charger can deliver improved hardware utilization and higher power density without a corresponding increase in cost or implementation complexity. The paper describes the magnetic realization and presents finite-element and circuit-level simulation results to confirm minimal interaction between the two charging paths. The study demonstrates that the proposed charger is a viable option for flexible, high-power EV charging systems.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)

Optical nanofiber testbeds for benchmarking membrane-waveguide photonic integrated circuit platforms toward on-chip quantum inertial sensing

Recent advances in cold atom interferometry with optical and magnetic atom guides have set the stage for quantum inertial sensors capable of operating in dynamic environments. In this work, we present three key innovations—evanescent-field (EF) atom guides, optical nanofiber testbeds, and membrane-waveguide photonic integrated circuit (PIC) platforms—to advance EF-guided atom interferometry. First, we demonstrate EF atom guides on optical nanofiber testbeds, which serve as performance benchmarks for our membrane-waveguide PIC platforms. Second, we achieve low-power (⁠ ~ 5 mW) guiding of freely moving, laser-cooled 133 Cs atoms in two-color, traveling-wave EF optical dipole traps at the novel, heat-efficient magic wavelengths of 793 and 937 nm (i.e., “793/937-nm EF atom guides”). Concurrently, we design and fabricate membrane-waveguide PIC platforms for these EF atom guides; in our prior work, we showed that these structures safely accommodate 4–6 times the required optical trap power under vacuum and enable dense cold atom generation via magneto-optical trapping in the vicinity of the optical wavguide for efficient loading. Third, we verify preserved atomic coherence via microwave fields and EF-coupled Doppler-free Raman beams; to our knowledge, this is the first report of coherence fringes driven by co-propagating EF-coupled Raman beams with only 150 nW of total optical power. By providing a direct comparison between optical nanofiber testbeds and membrane-waveguide PIC platforms, our results lay critical groundwork for the on-chip realization of EF-guided atom interferometry and the development of fully integrated, compact, lightweight, and low-power quantum accelerometers and gyroscopes.

Orozco, Adrian [Sandia National Laboratories (SNL-

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Electrical Control of Magnetic Resonance in Phase Change Materials

Metal–insulator transitions (MITs) in resistive switching materials can be triggered by an electric stimulus that produces significant changes in the electrical response. When these phases have distinct magnetic characteristics, dramatic changes in the spin excitations are also expected. The transition metal oxide La 0.7 Sr 0.3 MnO 3 (LSMO) is a ferromagnetic metal at low temperatures and a paramagnetic insulator above room temperature. When LSMO is in its metallic phase, a critical electrical bias has been shown to lead to an MIT that results in the formation of a paramagnetic resistive barrier transverse to the applied electric field. Using spin-transfer ferromagnetic resonance spectroscopy, we show that even for electrical biases less than the critical value that triggers the MIT, there is magnetic phase separation, with the spin-excitation resonances varying systematically with applied bias. Therefore, voltage-triggered MITs in LSMO can alter magnetic resonance characteristics, offering an effective method for tuning synaptic weights in neuromorphic circuits.

36 MATERIALS SCIENCE

Microwave microscope studies of trapped vortex dynamics in superconductors

Trapped vortices in superconductors introduce residual resistance in superconducting radio-frequency (SRF) cavities and disrupt the operation of superconducting quantum and digital electronic circuits. Understanding the detailed dynamics of trapped vortices under oscillating magnetic fields is essential for advancing these technologies. We have developed a near-field magnetic microwave microscope to study the dynamics of a limited number of trapped vortices under the probe when stimulated by a localized rf magnetic field. By measuring the local second-harmonic response (𝑃 2⁢f ) at subfemto-Watt levels, we isolate signals exclusively arising from trapped vortices, excluding contributions from surface defects and Meissner screening currents. Toy models of niobium superconductor hosting vortex pinning sites are introduced and studied with time-dependent Ginzburg-Landau (TDGL) simulations of probe/sample interaction to better understand the measured second-harmonic response. The simulation results demonstrate that the second-harmonic response of trapped vortex motion under a localized rf magnetic field shares key features with the experimental data. Here, this measurement technique provides access to vortex dynamics at the micrometer scale, such as depinning events and spatially resolved pinning properties, as demonstrated in measurements on a niobium film with an antidot flux pinning array.

43 PARTICLE ACCELERATORS

Machine learning for improved current-density reconstruction from two-dimensional vector magnetic images

The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high-spatial-frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional images of vector magnetic fields acquired by a quantum diamond microscope . Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower-signal-to-noise-ratio data, significantly reducing the data collection time and permitting reconstructions of weaker and three-dimensional current sources. Published by the American Physical Society 2025

Reed, Niko R. (ORCID:0009000305222403)

High-fidelity dimer excitations using quantum hardware

The quantum simulation of entangled spin systems can play a central role in quantum magnetic materials discovery. Additionally, the simulation of spectroscopic signatures, such as the dynamical structure factor accessed in inelastic neutron scattering (INS), necessitates a long timescale for circuit evolution. This is because the energy resolution is directly related to the time over which the circuit could be meaningfully evolved. However, canonical Trotterization requires deep circuits precluding such long-time evolution—even for a small number of qubits. Here, in this study, we demonstrate “direct” resource efficient fast-forwarding (REFF) measurements with short-depth circuits that can be used to capture longer time dynamics of spin Hamiltonians. We showcase the results of the dynamics of a quantum spin dimer, the basic quantum unit of emergent many-body spin systems, whose density of states we simulate accurately. The long temporal evolution and measurement of the two-spin correlation functions enable the calculation of the dynamical structure factor S⁡(Q = 0, ω) measured in the neutron scattering cross-section. We exhibit the clarity of the triplet gap and the triplet splitting of the quantum dimer with class-leading fidelity that enables comparison to experimental neutron data. Our results on current circuit hardware outline an important workflow to predict and benchmark against the outputs of INS experiments of quantum magnets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Design of MARCO, the New Solenoidal Detector Magnet for the ePIC Experiment at BNL

MARCO is the new superconducting solenoid for ePIC, the general-purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider at Brookhaven National Laboratory. Here, this 3.84 m long solenoid, with a bore diameter of 2.84 m, will provide a magnetic field of 2.0 T at the center with a nominal current of 4 kA at 4.5 K, for a total stored energy of 45 MJ. Its conductor is a NbTi Rutherford in Copper Channel (RICC), specially designed to stand the high mechanical loads induced by the magnetic field. Its copper stabilizer will assure the protection in case of quench. The coils are wound into six layers inside a thin external mandrel in brass, with a triple role of mechanical reinforcement, cryogenic support for the thermosiphon circuit and quench-back propagator. With a cold mass average radial thickness of just 7 cm, the magnet fulfills all the criterions of transparency for the particles directed to the hadronic calorimeter forecast around the cryostat. In this paper, the design of MARCO is presented, with a specific focus on the magnetic and quench analysis.

Calvelli, Valerio [Commissariat a l'Energie Atomiq

Magnetic flux distribution, quasiparticle spectroscopy, and quality factors in Nb films for superconducting qubits

Niobium is a practical material platform for superconducting microwave circuits; however, device-level performance can vary significantly depending on film growth and processing conditions. We compare three epitaxial Nb films grown on $c-$plane sapphire substrates under nominally identical conditions, except for the deposition temperature. To correlate internal quality factors, $Q_{\mathrm {i}}$, with material properties, we combine magneto-optical imaging of magnetic flux distribution with quasiparticle spectroscopy via measurements of the London penetration depth, $λ(T)$. In the low-$Q_{\mathrm i}$ film, there is a lesser ability to screen the magnetic field and an irregular temperature variation of $λ(T)$, implying the existence of localized in-gap states. High $Q_{\mathrm i}$ films show the opposite trend. We conclude that our measurements provide an efficient method for characterizing and optimizing superconducting films for quantum informatics applications.

Datta, Amlan [Ames Lab; Iowa State U.]

Signal Differentiation of Moving Magnetic Nanoparticles for Enhanced Biodetection and Diagnostics

Magnetic nanoparticles are extensively utilized as markers/signal labelling in various biomedical applications. Detecting and distinguishing magnetic signals from similarly sized moving magnetic nanoparticles in microfluidic systems is crucial yet challenging for biosensing. In this study, we have developed an original method to detect and differentiate magnetic signals from moving superparamagnetic (SPM) and ferrimagnetic (FM) nanoparticles of comparable sizes. Our approach utilizes a highly sensitive magnetic-coil-based sensor that harnesses the combined effects of giant magnetoimpedance (GMI) and an LC-resonance circuit, offering performance superior to that of conventional GMI sensors. Iron oxide nanoparticles, which have similar particle sizes but differing coercivities (zero for SPM and non-zero for FM) or similar zero coercivities but differing particle sizes, flow through the magnetic coil at controlled velocities. Their distinct effects are analyzed through changes in the complex impedance of the sensing system. Our findings provide a unique pathway for utilizing SPM and FM nanoparticles as innovative magnetic markers to identify specific biological entities, thereby expanding their potential applications.

Hwang, Kee Young

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects

Voltage-induced magnetic domain evolution in a phase-change material

Applying voltage to metal–insulator transition (MIT) materials allows electrical actuation of the local electronic phase state. In MIT systems that have the electronic order coupled with the magnetic order, voltage switching of the electronic phase state can also enable the electrical manipulation of magnetic properties. In this work, we utilized x-ray magnetic circular dichroism photoemission electron microscopy (XMCD-PEEM) to investigate the control of magnetic domain configurations in ferromagnetic MIT electrical switches. For applied voltages above a threshold value, the XMCD-PEEM images show that the magnetic domains separate into two distinct regions: one with a high contrast (white/black), indicating well-defined micrometer-scale magnetic domains with a component of their magnetization aligned parallel/antiparallel to the x-ray helicity, and the other with different shades of intermediate contrast (gray). Significant changes in magnetic domain configurations upon voltage biasing were only observed in these gray regions. Furthermore, the voltage-induced magnetic domain separation was found to be bias polarity-dependent, with the gray regions expanding from the opposite sample edge when the applied voltage polarity was reversed. This polarity-dependent electrical control of magnetic domain configurations during the MIT switching opens alternative opportunities in memory applications for magnetic MIT switching materials.

42 ENGINEERING

Flexible PCB Windings Size Optimization for Winding AC Resistance Minimization Under the Sinusoidal Voltage Regime

In this paper, optimization of the winding AC resistance of the flexible printed circuit board (FPCB) wire windings is performed. A one-dimensional model of the FPCB winding is introduced and an equation for the FPCB winding AC resistance and its low and medium frequency approximation are derived. The approximate FPCB winding AC resistance equation is used to derive optimum thickness of the FPCB winding conductor thickness at which minimum of winding AC resistance (global optimum) is achieved. The Finite Element Method analysis and experimental verification of derived equations (winding resistance, impedance, power loss, and temperature measurements) is performed in order validate derived model and winding resistance equation.

42 ENGINEERING

A Novel Low-Profile High-Efficiency Three-Phase Matrix Transformer

High step-down isolated DC-DC conversion from an 800 V DC bus to low-voltage, high-current outputs is required in automotive auxiliary converters and data center power supplies. In such applications, conventional transformer-based converters require large turns ratios, which increase winding resistance, leakage inductance, and magnetic height. This paper proposes a novel low-profile three-phase matrix transformer that realizes a large effective voltage ratio through flux division among multiple secondary legs, without increasing the physical turns count of each winding. As a result, the proposed structure reduces copper usage and transformer height while preserving the voltage conversion capability of a conventional three-phase transformer. Finite element analysis shows that the proposed design reduces magnetic height by 27%, ferrite volume by 34%, and copper volume by 28%. Circuit-level simulations of an 800 V/12 V,3 kW CLLLC dual-active-bridge converter further show that the lower winding resistance reduces total system loss by 91% and increases DC-DC efficiency from 82.6% to 97.6% at 3 kW output.

Inoue, Shuntaro [ORNL] (ORCID:0000000262637627)