Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Correcting Aberrations in Complex Magnet Systems for Muon Cooling Channels

Designing and simulating complex magnet systems needed for cooling channels in both neutrino factories and muon colliders requires innovative techniques to correct for both chromatic and spherical aberrations. Optimizing complex systems, such as helical magnets for example, is also difficult but essential. By using COSY INFINITY, a differential algebra based code, the transfer and aberration maps can be examined to discover what critical terms have the greatest influence on these aberrations.

43 PARTICLE ACCELERATORS↗

Dynamic Symmetry Breaking in Chiral Magnetic Systems

The Dzyaloshinskii–Moriya interaction (DMI) in magnetic systems stabilizes spin textures with preferred chirality, applicable to next-generation memory and computing architectures. In perpendicularly magnetized heavy-metal/ferromagnet films, the interfacial DMI originating from structural inversion asymmetry and strong spin-orbit coupling favors chiral Néel-type domain walls (DWs) whose energetics and mobility remain at issue. Thus, a new effect is characterized in which domains expand unidirectionally in response to a combination of out-of-plane and in-plane magnetic fields, with the growth direction controlled by the in-plane field strength. These growth directionalities and symmetries with applied fields cannot be understood from static treatments alone. The authors theoretically demonstrate that perpendicular field torques stabilize steady-state magnetization profiles highly asymmetric in elastic energy, resulting in a dynamic symmetry breaking consistent with the experimental findings. This phenomenon sheds light on the mechanisms governing the dynamics of Néel-type DWs and expands the utility of field-driven DW motion to probe and control chiral DWs.

36 MATERIALS SCIENCE↗

Performance of a superconducting magnet system operated in the Super Omega Muon beam line at J-PARC

A superconducting magnet system, which is composed of an 8 m long solenoid for transportation and 12 short solenoids for focusing, has been developed for Muon Science Establishment facility of J-PARC. The transport solenoid is composed of a 6 m straight section connected to a 45 degree curved section at each end. Muons of various momenta and of both electric charges are transported through the solenoid inner bore with an effective diameter of 0.3 m, where 2 T magnetic field is induced. There are 12 focusing solenoids with an effective bore diameter of 0.6 m and a length of 0.35 m arranged on a straight line at suitable intervals. The maximum central field of each focusing solenoid is 0.66 T. All solenoid coils are cooled by GM cryocoolers through their own conductions. The magnet system has been installed into the beam line in the summer of 2012, and its performance has been checked. Beam commissioning has been carried out since October 2012. During beam operation, temperature rise over 6 K in the transport solenoid due to a nuclear heating from the muon production target is observed at beam intensity of about 300 kW.

43 PARTICLE ACCELERATORS↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

Room temperature long range ferromagnetic ordering in Ni{sub 0.58}Zn{sub 0.42}Co{sub 0.10}Cu{sub 0.10}Fe{sub 1.8}O{sub 4} nano magnetic system

The structural and magnetic behavior of sol-gel autocombustion synthesized nanocrystalline Ni{sub 0.58}Zn{sub 0.42}Co{sub 0.10}Cu{sub 0.10}Fe{sub 1.8}O{sub 4} have been investigated by X-ray diffraction (XRD), transmission electron microscopy (TEM), Mössbauer spectroscopy and vibrating sample magnetometer(VSM). Sample of high purity and high homogeneity was obtained by calcination at low temperature (500°C) resulting in nanoparticles of average diameter ∼15nm as determined by XRD and further confirmed by TEM. X-ray diffraction (XRD) and selective area diffraction (SAED) confirmed the single phase of the sample. Mössbauer results are supported by magnetization data. Well defined sextets and appearance of hysteresis at room temperature indicate the existence of ferromagnetic coupling at room temperature finding material utility in magnetic storage data. The existence of iron in ferric state confirmed by isomer shift is a clear evidence of improved magnetic properties of the present system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Analysis and Simulations of the Abort Kicker Magnets Systems for the Electron-Ion Collider

The Abort Kicker Magnets system used in the current Relativistic Heavy Ion Collider (RHIC) to steer the circulating beam into the dump will be subjected to higher heat loads in the Electron-Ion Collider (EIC). After analyzing the existing abort kicker magnets and running thermal simulations in ANSYS it was concluded that they may not be suitable for use as-is in the future EIC due to heat and impedance concerns in the magnets. Possible solutions include adding a round titanium-coated ceramic beam tube to help solve the heat and impedance concerns, but this will reduce the limiting aperture of the kicker magnet. Another possible solution to meet all the performance requirements for EIC would be to add titanium-coated ceramic plates with water-cooling and tapered transitions that significantly improve the impedance and lower the heat in the magnets with less reduction to the aperture.

43 PARTICLE ACCELERATORS↗

Design of a New Superconducting Magnet System for High Strength Minimum-B Fields for ECRIS

A novel Mixed Axial and Radial field System (MARS) seeks to enhance the B fields inside the plasma chamber within the limits of a given conductor, thereby making it possible to raise the operating fields for Electron Cyclotron Resonance Ion Sources (ECRISs). The MARS concept consists of a hexagonally shaped closed-loop coil and a set of auxiliary solenoids. The application of MARS will be combined with a hexagonal plasma chamber to maximize the use of the radial fields at the chamber inner surfaces. Calculations using Opera's TOSCA-3D solver have shown that MARS can potentially generate up to 50% higher fields and use of only about one half of the same superconducting wire, as compared with existing magnet designs in ECRISs. A MARS magnet system built with Nb 3 Sn coils could generate a high strength minimum-B field of maxima of ≥ 10 T on axis and ~6 T radially in an ECRIS plasma chamber. Following successful development, the MARS magnet system will be the best magnet scheme for the next generation of ECRISs. This paper will present the MARS concept, magnet design, prototyping a copper closed-loop coil, and discussions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SPY: a conceptual design study of a magnet system for a high-pressure gaseous TPC neutrino detector

Here, we present a novel conceptual design for a magnet system that provides the magnetic field necessary for the analysis of tracks in a high-pressure gaseous argon TPC while simultaneously serving as a pressure vessel to contain the TPC gas volume. The magnet was developed within a Near Detector proposal for the Deep Underground Neutrino Experiment (DUNE). The high-pressure gaseous argon TPC is a component proposed to be one of the elements of an ensemble of near detectors that are needed for DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-211: Evaluation of a Dual Focusing Magnet System for the Treatment of Small Proton Targets

Purpose: To investigate magnetic focusing for small volume proton targets using a doublet combination of quadrupole rare earth permanent magnet Halbach cylinder assemblies Methods: Monte Carlo computer simulations were performed using the Geant4 toolkit to compare dose depositions of proton beams transported through two focusing magnets or in their absence. Proton beams with energies of 127 MeV and initial diameters of 5, 8 and 10 mm were delivered through two identical focusing magnets similar to those currently in experimental use at Loma Linda University Medical Center. Analogous experiments used optimized configurations based on the simulation results. Dose was measured by a diode detector and Gafchromic EBT3 film and compared to simulation data. Based on results from the experimental data, an additional set of simulations was performed with an initial beam diameter of 18 mm and a two differing length magnets (40mm & 68mm). Results: Experimental data matched well with Monte Carlo simulations. However, under conditions necessary to produce circular beam spots at target depth, magnetically focused beams using two identical 40 mm length magnets did not meet all of our performance criteria of circular beam spots, improved peak to entrance (P/E) dose ratios and dose delivery efficiencies. The simulations using the longer 68 mm 2nd magnet yielded better results with 34% better P/E dose ratio and 20–50% better dose delivery efficiencies when compared to unfocused 10 mm beams. Conclusion: While magnetic focusing using two magnets with identical focusing power did not yield desired results, ongoing Monte Carlo simulations suggest that increasing the length of the 2nd magnet to 68 mm could improve P/E dose ratios and dose efficiencies. Future work includes additional experimental validation of the longer 2nd magnet setup as well as experiments with triplet magnet systems. This project was sponsored with funding from the Department of Defense (DOD# W81XWH-BAA-10-1).

60 APPLIED LIFE SCIENCES↗

A Bulk Superconducting Magnetic System for the CLAS12 Target at Jefferson Lab

A feasibility study of a bulk magnetic system for the target of an experiment to measure the transverse spin effects in semi-inclusive deep inelastic scattering (SIDIS) at 11 GeV with a transversely polarized target using the CLAS12 detector is presented. An experiment has been approved with the highest priority rating to study spin azimuthal asymmetries in SIDIS using 11-GeV polarized electron beams from the upgraded CEBAF facility and the CLAS12 detector equipped with a transversely polarized target. The transverse target in CLAS12 requires the shielding of a volume inside the longitudinal field of the main solenoid. In the shielded region, a transverse target magnet can operate; for the proposed magnetic configuration, the main solenoid maximum magnetic induction is 2 T. A bulk MgB 2 cylinder cooled in liquid helium is proposed both to shield the longitudinal field of the main solenoid and to provide a transverse field induction up to 1.2 T for the hydrogen deuteride ice (HD-ice) target. The installation and magnetization procedure will be described. The magnetization procedure has to be compatible with the polarization and installation procedure of the HD-ice target. The design of a test bench to measure the transverse magnetization of a MgB2 bulk cylinder cooled by a coldhead is presented together with the scheduled measurements.

43 PARTICLE ACCELERATORS↗

A Dual 5T Superconducting Magnet System for the Brookhaven National Lab Electron Beam Ion Source

Cryomagnetics has delivered an upgraded magnet system to the Brookhaven National Laboratory's RHIC Electron Beam Ion Source project. This consists of two 2.25-m long, 215-mm room temperature bore 5T solenoids separated by 20 cm. The initial system used a single PT-415RM cryocooler but was unstable a long term. As a result, the new system adds a second SHI cryocooler, which produces much higher recondensing margins.

43 PARTICLE ACCELERATORS↗

Conceptual Design of DUNE Near Detector Superconducting Magnet System

The Deep Underground Neutrino Experiment (DUNE) has formed a near detector design group (NDDG) tasked with delivering a CDR by the end of 2019. The DUNE Near Detectors will be housed in an underground hall on the Fermilab site. The two main detector systems are a liquid argon detector and a high-pressure gas time projection chamber (HPgTPC). The HPgTPC requires a magnet that generates a 0.5 T solenoidal magnetic field in a large volume of 6 m diameter, and 5 m length. Herein, we present a superconducting magnet system design. We investigated: an open air core magnet with three coils, and a five coils system having two active fringe field shielding coils. Coils positions were optimized to obtain the specified field homogeneity in the magnet good field region, while minimizing the Lorentz forces and the superconductor volume. We discuss the magnetic, mechanical, and thermal conceptual designs.

43 PARTICLE ACCELERATORS↗

Initial performance of the magnet system in the splitter/combiner section of the Cornell-Brookhaven Energy-Recovery Linac Test Accelerator

The Cornell-Brookhaven Energy-recovery Linac Test Ac- celerator is a four-pass, 150-MeV electron accelerator with a six-cell 1.3 GHz superconducting-RF linear accelerator and a fixed-field alternating-gradient (FFAG) return loop made up of Halbach-style quadrupole magnets. The optics matching between the linear accelerator and the return loop is achieved with a conventional magnet system comprised of 50 dipole magnets and 64 quadrupole magnets in four beamlines at each end of the linac. The 42-, 78-, 114- and 150-MeV electron beams are separated into independent vacuum chambers in order to allow for the path-length ad- justment required by energy recovery. We report on the first beam tests of the initial installation of the splitter/combiner section at the exit of the linac. The vacuum system of the 42-MeV S1 line was installed during the first week of April. Nine dipole and four quadrupole magnets were installed and surveyed into position the following week, and the water cooling system was commissioned. A 6-MeV beam passed through the line on April 11 with no need for adjusting pre-set magnet excitation currents. One week later, time- of-flight measurements were used to calibrate and phase the individual superconducting RF cavities. The S1 magnet settings were then scaled up to achieve 5-cavity, 42-MeV operation through the first nine FFAG permanent-magnet quadrupoles. This initial Fractional Arc Test will conclude on May 18, when the installation of the remaining seven split- ter/combiner lines and the return loop will begin. CBETA operations are scheduled to begin in early 2019.

43 PARTICLE ACCELERATORS↗

Improved thermal isolation for superconducting magnet systems

Closed-cycle refrigerating system for superconductive magnet and maser is operated in vacuum environment. Each wire leading from external power source passes through cooling station which blocks heat conduction. In connection with these stations, switch with small incandescent light bulb, which generates heat, is used to stop superconduction.

Wiebe, E. R.↗

Spin-liquid behavior of the three-dimensional magnetic system Ba 3 NiIr 2 O 9 with S = 1

The quantum spin liquid (QSL) is an exotic phase of magnetic materials where the spins continue to fluctuate without any symmetry breaking down to zero temperature. Among the handful reports of QSL with spin S ≥ 1, examples with magnetic ions on a three-dimensional (3D) magnetic lattice are extremely rare since both larger spin and higher dimension tend to suppress quantum fluctuations. In this work, we offer a new strategy to achieve 3D QSL with high spin by utilizing two types of transition metal ions; both are magnetically active but located at crystallographically inequivalent positions. Furthermore, we design a 3D magnetic system Ba 3 NiIr 2 O 9 consisting of interconnected corner-shared NiO 6 octahedra and face-shared Ir 2 O 9 dimer, both having triangular arrangements in a-b plane. X-ray absorption spectroscopy measurements confirm the presence of Ni 2+ (S = 1). Furthermore, our detailed thermodynamic and magnetic measurements reveal that this compound is a realization of gapless QSL state down to at least 100 mK. Ab initio calculations find a strong magnetic exchange between Ir and Ni sublattices and in-plane antiferromagnetic coupling between the dimers, resulting in dynamically fluctuating magnetic moments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The LHC magnet system and its status of development

CERN is preparing for the construction of a new high energy accelerator/collider, the Large Hadron Collider (LHC). This new facility will mainly consist of two superconducting magnetic beam channels, 27 km long, to be installed in the existing LEP tunnel. The magnetic system comprises about 1200 twin-aperture dipoles, 13.145 m long, with an operational field of 8.65 T, about 600 quadrupoles, 3 m long, and a very large number of other superconducting magnetic components. A general description of the system is given together with the main features of the design of the regular lattice magnets. The paper also describes the present state of the magnet R & D program. Results from short model work, as well as from full scale prototypes will be presented, including the recently tested 10 m long full-scale prototype dipole manufactured in industry.

Bona, Maurizio↗