Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Use of knowledge-based restraints in phenix.refine to improve macromolecular refinement at low resolution

Traditional methods for macromolecular refinement often have limited success at low resolution (3.0–3.5 Å or worse), producing models that score poorly on crystallographic and geometric validation criteria. To improve low-resolution refinement, knowledge from macromolecular chemistry and homology was used to add three new coordinate-restraint functions to the refinement program phenix.refine . Firstly, a `reference-model' method uses an identical or homologous higher resolution model to add restraints on torsion angles to the geometric target function. Secondly, automatic restraints for common secondary-structure elements in proteins and nucleic acids were implemented that can help to preserve the secondary-structure geometry, which is often distorted at low resolution. Lastly, we have implemented Ramachandran-based restraints on the backbone torsion angles. In this method, a φ,ψ term is added to the geometric target function to minimize a modified Ramachandran landscape that smoothly combines favorable peaks identified from nonredundant high-quality data with unfavorable peaks calculated using a clash-based pseudo-energy function. All three methods show improved MolProbity validation statistics, typically complemented by a lowered R free and a decreased gap between R work and R free .

59 BASIC BIOLOGICAL SCIENCES↗

Deformable elastic network refinement for low-resolution macromolecular crystallography

An overview of applications of the deformable elastic network (DEN) refinement method is presented together with recommendations for its optimal usage. Crystals of membrane proteins and protein complexes often diffract to low resolution owing to their intrinsic molecular flexibility, heterogeneity or the mosaic spread of micro-domains. At low resolution, the building and refinement of atomic models is a more challenging task. The deformable elastic network (DEN) refinement method developed previously has been instrumental in the determinion of several structures at low resolution. Here, DEN refinement is reviewed, recommendations for its optimal usage are provided and its limitations are discussed. Representative examples of the application of DEN refinement to challenging cases of refinement at low resolution are presented. These cases include soluble as well as membrane proteins determined at limiting resolutions ranging from 3 to 7 Å. Potential extensions of the DEN refinement technique and future perspectives for the interpretation of low-resolution crystal structures are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Analysis of the Automated Meteorological Profiling System Low Resolution Flight Element

A study was conducted to determine the quality of thermodynamic and wind data measured by or derived from the Low Resolution Flight Element (LRFE) of the Automated Meteorological Profiling System (AMPS). The AMPS LRFE replaced the Meteorological Sounding System (MSS), which was used to provide vertical profiles of thermodynamic and low-resolution wind data in support of spacecraft launch operations at the Cape Canaveral Air Force Station (CCAFS) and NASA Kennedy Space Center (KSC), Florida. Air temperature, relative humidity, and height, which are directly measured by the LRFE, are used to derive air pressure and density. Test flights were conducted where an LRFE sonde and an MSS sonde were attached to the same balloon and the two profiles were compared. MSS data was used as the standard reference data. The objective of the thermodynamic testing was to determine a) if the LRFE met Space Shuttle Program (SSP) accuracy requirements outlined in the Space Shuttle Launch and Landing Program Requirements Document (PRD) and/or, b) if the LRFE met or exceeded MSS data quality. AMPS uses the Global Positioning System (GPS) to determine wind speed and direction. In order to provide a basis for comparison, either an AMPS High Resolution Flight Element (HRFE) or a radar tracked Jimsphere was released simultaneously with each AMPS LRFE at CCAFS. The goal of these tests was to determine if the LRFE wind data met the requirement for low-resolution wind data defined in the Shuttle PRD. Based on the available data, the LRFE is shown to produce more consistent thermodynamic measurements than the MSS. The LRFE is also shown to meet the Shuttle PRD requirements for low resolution wind data.

Leahy, Frank B.↗

Photometric calibration of the International Ultraviolet Explorer (IUE) at low resolution - The LWP camera

We present and discuss the low resolution absolute calibration for the LWP camera of the International Ultraviolet Explorer (IUE). The calibration, implemented in routine processing of LWP low resolution images on December 22, 1987 at both GSFC and VILSPA IUE ground stations, is based on the last set of Intensity Transfer Function (ITF 2) obtained in September 1984 and on a substantially larger amount of IUE observations of standard stars than used for the preliminary calibration by Cassatella & Harris (1983) based on the earlier ITF (ITF 1). The new ITF and the associated calibration provide upgraded performances in flux accuracy, signal-to-noise ratio and linearity with respect to the earlier LWP ITF1 which was implemented in processing LWP data obtained in the period from October 16, 1983 until December 21, 1987.

Cassatella, A.↗

Model-building strategies for low-resolution X-ray crystallographic data

Interpretation of low-resolution X-ray crystallographic data can prove to be a difficult task. The challenges faced in electron-density interpretation, the strategies that have been employed to overcome them and developments to automate the process are reviewed. The interpretation of low-resolution X-ray crystallographic data proves to be challenging even for the most experienced crystallographer. Ambiguity in the electron-density map makes main-chain tracing and side-chain assignment difficult. However, the number of structures solved at resolutions poorer than 3.5 Å is growing rapidly and the structures are often of high biological interest and importance. Here, the challenges faced in electron-density interpretation, the strategies that have been employed to overcome them and developments to automate the process are reviewed. The methods employed in model generation from electron microscopy, which share many of the same challenges in providing high-confidence models of macromolecular structures and assemblies, are also considered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the utility of low resolution IUE spectroscopy of the 2800 A Mg II lines as a stellar chromosphere indicator

Low resolution IUE spectroscopy of the 2800-A Mg II h and k lines is shown to provide a useful means for documenting chromospheric activity among relatively young dwarf stars. An index I(Mg II) has been defined which measures the integrated flux in the region 2784-2814 A relative to the flux interpolated from nearby comparison regions. Values of this index have been derived from low resolution IUE spectra for a sample of field dwarfs for which Ca II H and K line indices have been published as part of the Mount Wilson HK program. The large range in chromospheric activity among field dwarfs that is exhibited by the Mount Wilson Ca II S index is found to also be reflected by the lower resolution I(Mg II) index. Using an age calibration of Ca II emission line strengths derived by Barry, it is found that the value of I(Mg II) can be used to distinguish between dwarfs younger and older than 3 Gyr. The low resolution nature of the I(Mg II) index means that it holds potential for use as an age diagnostic for stellar population studies. Among dwarfs of age greater than 3 Gyr there is some evidence that this Mg II index is affected by line blanketing.

Smith, Graeme H.↗

Prospects for Measuring Abundances of >20 Elements with Low-resolution Stellar Spectra

Understanding the evolution of the Milky Way calls for the precise abundance determination of many elements in many stars. A common perception is that deriving more than a few elemental abundances ([Fe/H], [ α /Fe], perhaps [C/H], [N/H]) requires medium-to-high spectral resolution, R ≳ 10,000, mostly to overcome the effects of line blending. In a recent work, we presented an efficient and practical way to model the full stellar spectrum, even when fitting a large number of stellar labels simultaneously. In this paper, we quantify to what precision the abundances of many different elements can be recovered, as a function of spectroscopic resolution and wavelength range. In the limit of perfect spectral models and spectral normalization, we show that the precision of elemental abundances is nearly independent of resolution, for a fixed exposure time and number of detector pixels; low-resolution spectra simply afford much higher S/N per pixel and generally larger wavelength range in a single setting. We also show that estimates of most stellar labels are not strongly correlated with one another once R ≳ 1000. Modest errors in the line-spread function, as well as small radial velocity errors, do not affect these conclusions, and data-driven models indicate that spectral (continuum) normalization can be achieved well enough in practice. These results, to be confirmed with an analysis of observed low-resolution data, open up new possibilities for the design of large spectroscopic stellar surveys and for the reanalysis of archival low-resolution data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

MEASURING ORGANIC MOLECULAR EMISSION IN DISKS WITH LOW-RESOLUTION SPITZER SPECTROSCOPY

We explore the extent to which Spitzer Infrared Spectrograph (IRS) spectra taken at low spectral resolution can be used in quantitative studies of organic molecular emission from disks surrounding low-mass young stars. We use Spitzer IRS spectra taken in both the high- and low-resolution modules for the same sources to investigate whether it is possible to define line indices that can measure trends in the strength of the molecular features in low-resolution data. We find that trends in the HCN emission strength seen in the high-resolution data can be recovered in low-resolution data. In examining the factors that influence the HCN emission strength, we find that the low-resolution HCN flux is modestly correlated with stellar accretion rate and X-ray luminosity. Correlations of this kind are perhaps expected based on recent observational and theoretical studies of inner disk atmospheres. Our results demonstrate the potential of using the large number of low-resolution disk spectra that reside in the Spitzer archive to study the factors that influence the strength of molecular emission from disks. Such studies would complement results for the much smaller number of circumstellar disks that have been observed at high resolution with IRS.

79 ASTRONOMY AND ASTROPHYSICS↗

Interpretation of very low resolution X-ray electron-density maps using core objects

The interpretation of a 20 Å resolution electron-density map using segmentation and pattern-recognition-based identification of domain shapes is described. A novel approach to obtaining structural information from macromolecular X-ray data extending to resolutions as low as 20 Å is presented. Following a simple map-segmentation procedure, the approximate shapes of the domains forming the structure are identified. A pattern-recognition comparative analysis of these shapes and those derived from the structures of domains from the PDB results in candidate structural models that can be used for a fit into the density map. It is shown that the placed candidate models can be employed for subsequent phase extension to higher resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Resolution Data for a Low-Resolution World

In the past 15 years, the upper section of Cañon de Valle has been severely altered by wildfires and subsequent runoff events. Loss of root structures on high-angle slopes results in debris flow and sediment accumulation in the narrow canyon bottom. The original intent of the study described here was to better understand the changes occurring in watershed soil elevations over the course of several post-fire years. An elevation dataset from 5 years post-Cerro Grande fire was compared to high-resolution LiDAR data from 14 years post-Cerro Grande fire (also 3 years post-Las Conchas fire). The following analysis was motivated by a problematic comparison of these datasets of unlike resolution, and therefore focuses on what the data reveals of itself. The objective of this study is to highlight the effects vegetation can have on remote sensing data that intends to read ground surface elevation.

47 OTHER INSTRUMENTATION↗

Theoretical Models of Low-Resolution Microwave Rotational Spectra of Ethane- and Propanethiol

Additive modeling of low-resolution microwave spectra of heteroisomeric substituted hydrocarbons produced theoretical spectra of ethanethiol and propanethiol in the range 0–2 THz with maxima at 465 ± 20 and 240 ± 20 GHz. More precise calculations in a narrow frequency band of these ranges used spectral line half-widths of 1.5, 0.8, and 0.5 MHz that modeled conditions in different layers of Earth’s troposphere. The strongest extrema of the low-resolution spectra of the studied molecules were found at 486 ± 5, 446 ± 5, and 436 ± 5 (ethanethiol) and at 257 ± 5, 239 ± 5, and 234 ± 5 GHz (propanethiol). Various aspects of the application of the results were discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray structure determination at low resolution

Refinement is meaningful even at 4 Å or lower, but with present methodologies it should start from high-resolution crystal structures whenever possible. As an example of structure determination in the 3.5–4.5 Å resolution range, crystal structures of the ATPase p97/VCP, consisting of an N-terminal domain followed by a tandem pair of ATPase domains (D1 and D2), are discussed. The structures were originally solved by molecular replacement with the high-resolution structure of the N-D1 fragment of p97/VCP, whereas the D2 domain was manually built using its homology to the D1 domain as a guide. The structure of the D2 domain alone was subsequently solved at 3 Å resolution. The refined model of D2 and the high-resolution structure of the N-D1 fragment were then used as starting models for re-refinement against the low-resolution diffraction data for full-length p97. The re-refined full-length models showed significant improvement in both secondary structure and R values. The free R values dropped by as much as 5% compared with the original structure refinements, indicating that refinement is meaningful at low resolution and that there is information in the diffraction data even at ∼4 Å resolution that objectively assesses the quality of the model. It is concluded that de novo model building is problematic at low resolution and refinement should start from high-resolution crystal structures whenever possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deformable complex network for refining low-resolution X-ray structures

A new refinement algorithm called the deformable complex network that combines a novel angular network-based restraint with a deformable elastic network model in the target function has been developed to aid in structural refinement in macromolecular X-ray crystallography. In macromolecular X-ray crystallography, building more accurate atomic models based on lower resolution experimental diffraction data remains a great challenge. Previous studies have used a deformable elastic network (DEN) model to aid in low-resolution structural refinement. In this study, the development of a new refinement algorithm called the deformable complex network (DCN) is reported that combines a novel angular network-based restraint with the DEN model in the target function. Testing of DCN on a wide range of low-resolution structures demonstrated that it constantly leads to significantly improved structural models as judged by multiple refinement criteria, thus representing a new effective refinement tool for low-resolution structural determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Stars of the HETDEX Survey. I. Radial Velocities and Metal-poor Stars from Low-resolution Stellar Spectra

The Hobby–Eberly Telescope Dark Energy Experiment (HETDEX) is an unbiased, massively multiplexed spectroscopic survey, designed to measure the expansion history of the universe through low-resolution ( R ~ 750) spectra of Ly α emitters. In its search for these galaxies, HETDEX will also observe a few times 10 5 stars. In this paper, we present the first stellar value-added catalog within the internal second data release of the HETDEX Survey (HDR2). The new catalog contains 120,571 low-resolution spectra for 98,736 unique stars between 10 < G < 22 spread across the HETDEX footprint at relatively high ( b ~ 60°) Galactic latitudes. With these spectra, we measure radial velocities (RVs) for ~42,000 unique FGK-type stars in the catalog and show that the HETDEX spectra are sufficient to constrain these RVs with a 1 σ precision of 28.0 km s -1 and bias of 3.5 km s -1 with respect to the Large Sky Area Multi-Object Fibre Spectroscopic Telescope surveys and 1 σ precision of 27.5 km s -1 and bias of 14.0 km s -1 compared to the Sloan Extension for Galactic Understanding and Exploration survey. Since these RVs are for faint ( G ≥ 16) stars, they will be complementary to Gaia. Using t-Distributed Stochastic Neighbor Embedding (tSNE), we also demonstrate that the HETDEX spectra can be used to determine a star’s T eff , and log g and its [Fe/H]. With the tSNE projection of the FGK-type stars with HETDEX spectra we also identify 416 new candidate metal-poor ([Fe/H] < -1 dex) stars for future study. These encouraging results illustrate the utility of future low-resolution stellar spectroscopic surveys.

Astronomy & Astrophysics↗

X-ray structure determination using low-resolution electron microscopy maps for molecular replacement

Structures of multi-subunit macromolecular machines are primarily determined by either electron microscopy (EM) or X-ray crystallography. In many cases, a structure for a complex can be obtained at low resolution (at a coarse level of detail) with EM and at higher resolution (with finer detail) by X-ray crystallography. The integration of these two structural techniques is becoming increasingly important for generating atomic models of macromolecular complexes. A low-resolution EM image can be a powerful tool for obtaining the "phase" information that is missing from an X-ray crystallography experiment, however integration of EM and X-ray diffraction data has been technically challenging. Here we show a step-by-step protocol that explains how low-resolution EM maps can be placed in the crystallographic unit cell by molecular replacement, and how initial phases computed from the placed EM density are extended to high resolution by averaging maps over non-crystallographic symmetry. As the resolution gap between EM and Xray crystallography continues to narrow, the use of EM maps to help with X-ray crystal structure determination, as described in this protocol, will become increasingly effective.

59 BASIC BIOLOGICAL SCIENCES↗