Multi-objective optimization of low-GWP mixture composition and heat exchanger circuitry configuration for improved system performance and reduced refrigerant flammability

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗

Performance Assessment of High-Efficiency Refrigerated Display Cases with Low-GWP Refrigerants: Preprint

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas (GHG) reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison was to assess the energy performance of two high efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513a, respectively. Performance of these display cases were compared to a baseline fixture using HFC (R-134a) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores, and small supermarkets. The high efficiency cases were equipped with energy efficient lighting, improved panel insulation, high efficiency evaporator and condenser fan motors, and high effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions. However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining target product temperature, the energy efficient fixtures containing R-290 and R-513a consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134a refrigerant. The daily energy consumption of the R-290, R-513a, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

A Numerical Modelling Study on Submerged Condensers for Heat Pump Water Heaters Using Low-GWP Refrigerants

Challenges to global warming require reduction of GHG emissions, and increased use of renewable energy. Heat pumps extract energy from renewable sources and convert them to more useable forms for space conditioning, space heating and for water heating. They can be powered by renewable sources of electricity and must be engineered to use low global warming potentials (GWP) refrigerants (e.g., propane, GWP = 3) for a sustainable economy. Therefore, an electric heat pump water heaters (HPWH) using propane as refrigerant are developed in Oak Ridge National Laboratory to replace water heaters using all electric resistance and natural gas. A submerged condenser directly contacting with water is employed in the HPWH, which eliminates heat transfer barrier of the tank wall, and also prevents heat loss from the condenser tubes to the surrounding air. In present work, a numerical model is developed to model the submerged condenser. A dynamic temperature distribution on the condenser tubes from experimental data is applied to the model to enhance the accuracy of the numerical model. The model is essential to guide the design of the submerged condenser to achieve the performance required by the HPWH.

Zhang, Mingkan↗

A DYNAMIC ENERGY MODEL FOR DISPLAY CASES CONSIDERING FAULTS IN SUPERMARKETS FOR LOW GWP REFRIGERANTION

Display cases are widely used in supermarkets to demonstrate commercial goods for customers, like milk, frozen food, ice-cream, etc. There are two types of display case: open case and closed case. The goods inside display cases need to stay within a stable temperature range to meet the quality standards. However, due to variety of faults (e.g., leaving door opening), it is hard to maintain a stable temperature. The associated energy consumption from display cases is extremely high due to faults. There is a need for a dynamic energy model to accurately predict the good temperature and energy consumption under faults. A dynamic model is developed based on operation data collected through field tests in a low global warming potential (GWP) refrigeration system, at Oak Ridge National Laboratory.

Li, Yanfei↗

MaxTech HPWH Using Ultra-low GWP Refrigerant

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of superior performance compared with that of alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, significant interest exists for deploying low global warming potential refrigerants to minimize environmental impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications - Design and Simulation Practice to Identify Charge Reduction Opportunities for Residential AC/HP Units

Based on three 5-ton, single-speed heat pumps (HPs), using R-410A, which use the same compressor, indoor blower and outdoor fan, the DOE/ORNL Heat Pump Design Model was used to conduct comparative modelling study. Regarding charge reduction opportunities, in general, we recommend: 1. Downsizing the outdoor condenser will reduce the required system charge, i.e. using smaller tube diameters or fewer tubes; reducing the evaporator inner volume is less important; to offset the reduced condenser tube side surface area, one can increase the air side surface area (fin density) or condenser air flow rate via using a more efficient fan. 2. microchannel heat exchangers are most effective in reducing the required charge, by up to 60% in the condenser and evaporator. To develop low charge systems, one should at least use a microchannel heat exchanger as the outdoor condenser. 3. TXV systems are less sensitive to charge reduction. For the drop-in application, one can decrease the charge to minimize the liquid section in the condenser, at the expense of minor performance degradation; for example, when reducing the system charge by 15% (decrease the subcooling degree to 2R), the simulation results prove that the decrease is less than 3% in the EER and less than 6% in the capacity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications - Literature Survey for Impact of Varying Refrigerant Charge on AC System Performance

The report summarizes the findings of ASHRAE Research project 1173, by Purdue University to assess the impact of varying refrigerant charge on air conditioner (AC) system performance. This project tested six residential air conditioners with varying the system charge in a wide range, using TXV or fixed-orifice as the expansion device. In summary, the systems using fixed-orifices are much more sensitive to reduction of the system charge than using TXVs. The systems using fixed-orifices had noticeable performance degradations when reducing the system charge below 90% relative to the factory charge; the systems using TXVs experienced drastic performance penalties when decreasing the system charge below 80%. In the cases, the TXVs were all fully open and couldn’t control the target superheat degree. In order to limit the system charge for lower-GWP refrigerants, without degrading the system performance much, the AC systems are recommended to use TXV and compact heat exchangers, i.e. micro-channel heat exchangers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications – Acquire Nortek Residential AC/HP Units for Evaluation and Model the Units Using HPDM

For the upcoming refrigerant transition from HFCs to minorly flammable HFO refrigerants (A2L), refrigerant charge reduction is important to mitigate the fire hazard. Microchannel heat exchangers (MHXs) are a mature technology, which is effective in reducing system charge while maintaining similar heat transfer performance. MHXs will be applied more widely when the new refrigerants are used. Prior studies of the A2L HFO blends were mostly focused on fin-and-tube coils (FTC). An in-depth study for an air conditioner (AC)/heat pump (HP) system using all microchannel heat exchangers is still lacking. In FY19, a side-to-side comparison will be conducted between two residential split heat pumps, one using all FTCs and the other using all MHXs for drop-in investigation, to identify potential issues for future design. The two heat pumps have similar rated capacity, SEER, HSPF levels, similar fan, blower and compressor, but differ in heat exchangers. Both the HPs use two-stage compressors to facilitate investigating different refrigerant flow rates. We will drop-in HFO refrigerants (replacements for R-410A, e.g. R452B, R447B, R32, etc.). The experiments will reveal the potential of MHXs for charge reduction, and how the two systems using A2L refrigerants operate under standard SEER and HSPF rating conditions. The two units were donated by our partner, i.e. Nortek Global HVAC, an industry leader in making heat pumps using all MHXs as well as FTCs. The units were shipped to ORNL this week, and the product design data were also shared for modeling the two units using HPDM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of low GWP Flammable Refrigerant Leak from Rooftop Units

One of the recent global trends in the air conditioning industry is to replace the high global warming potential (GWP) refrigerants such as R410A and R134A with alternative refrigerants that have lower GWP. However, most of these alternative refrigerants are classified as slightly flammable (classified by ASHRAE as A2L) which impose a potential fire risk. Therefore, research efforts have focused on the study of flammable refrigerants and their potential risk. In this paper, we present a numerical investigation to study one R32 (ASHRAE A2L) leak scenario from a 5 ton rooftop unit into a conference room with the dimensions of 40 × 30 × 8 ft (12.2 × 9.1 × 2.4 m). A catastrophic rupture of a Â-inch refrigerant line was simulated. A total charge of 15lb (6.8 kg) was leaked in 31.5 seconds. A mixture of air and refrigerant is diffused from four air diffusers mounted in the ceiling. The ducting system was simulated first to predict the air/refrigerant mixure entering the room from the four air diffusers.The total simulation time was 10 minutes to study the refrigerant diffusion and dispersion of the flammable refrigerant in the room after the inception of the leakage. The volume fraction is presented as a function of time at different monitoring points inside the room. The total room volume where the R32 concentration exceeds its LFL is quantified and presented as an indication of the risk of ignition.

Elatar, Ahmed↗

Optimization of Refrigerant Compositions for Low-GWP Refrigerant Mixtures Using Segment-by-segment Heat Exchanger and Detailed System Models

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

Li, Zhenning↗

Material Compatibility of 3D Printed Polymer Composites with Low GWP Refrigerants

The recent development of 3D printing brings numerous opportunities to develop polymer heat exchangers with desired configurations and allows access to the new complex engineering design for better performance. To be used in the HVAC&R system, the compatibility of these materials to refrigerants needs to be thoroughly investigated and understood. This study tested the material compatibility of the printed polymer composites according to the ASHRAE Guideline 38 using metal pressure vessels. These printed parts were tested with R-134A, R-1234YF, R-1234ZE, R-1233ZD(E), and 32-3 MAF POE (10 wt.%) was used as the lubricants. The change in volume, mass, hardness, and mechanical properties was studied in detail. Different compatibility of the composites with refrigerants was observed when the composition of the composite changed. After exposure to refrigerants, the morphological and thermal properties were studied with the scanning electron microscope, thermogravimetric analysis, and differential scanning calorimetry to further reveal the influence of these refrigerants.

Li, Kai↗