Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Loss of Coolant Accident”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A study on the impact of using a subchannel resolution for modeling of large break loss of coolant accidents

The nuclear industry is investigating the feasibility of transitioning from 18- to 24-month fuel cycles because of the positive impact it would have on the operational costs for the current fleet of light-water reactors. A challenge to making this change is the increased risk of fuel fragmentation, relocation, and dispersal (FFRD) due to the known potential for ceramic fuel to pulverize into fine particles at the higher discharge burnups. Previous work has been performed by the Nuclear Energy Advanced Modeling and Simulation program to assess FFRD risk in high-burnup cores using the BISON fuel performance code and a coarse mesh thermal hydraulics (T/H) solution for a loss-of-coolant accident (LOCA) using the TRACE system T/H code. Because of the importance of the T/H solution for FFRD assessment, this study seeks to investigate the impact of using higher-fidelity subchannel techniques for modeling of the LOCA transient. CTF was used to model a subregion of a high-burnup core that was depleted by the Virtual Environment for Reactor Applications (VERA) multiphysics core simulator. Both coarse-mesh and pin-resolved models were created in CTF, and a consistent coarse-mesh TRACE model was also developed to allow for benchmarking the code results. Further, a large-break loss-of-coolant accident (LBLOCA) reflood transient was simulated using these three models, and results were compared. Results showed some consistent differences between the CTF and TRACE coarse models, including a higher peak cladding temperature (PCT) prediction in CTF and later quenching in CTF; however, the transient clad temperature behavior was similar, and these differences are likely due to post-critical heat flux heat transfer modeling differences and minimum film boiling temperature model differences. The pin-resolved results indicate that the PCT in the lumped model is often under-predicted by as much as 70 °C and that PCT occurs at a different location than the high-power pin in the assembly. The lumped model predicts a difference of 10 °C or less between the average and hot pins in the assembly, whereas the pin-resolved model predicts a range of over 100 °C. These results indicate that higher-fidelity T/H results may have an impact on predicted core behavior during LOCA, which may be important to consider when assessing FFRD risk.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-scale simulation of high burnup UO2 nuclear fuel during loss-of-coolant accident conditions

To improve the economics of commercial nuclear energy generation, U.S. utilities are currently seeking licensing approval to operate UO2 fuel to higher burnups. One significant safety issue that must be addressed to obtain approval is the potential for fine fragmentation/pulverization of the fuel during a loss-of-coolant accident (LOCA). It has been hypothesized that pulverization is caused by the rapid increase of pressure in fission gas bubbles in the high burnup region of the fuel during a LOCA. To better understand this phenomenon, a novel phase-field model of the fission gas bubble microstructure in UO2 has been developed and implemented in Idaho National Laboratory (INL)'s Marmot application for phase-field simulation of nuclear materials. Simulations of the bubble response to steady-state and transient conditions were conducted, and the results were used to inform a mechanistic model of pulverization in BISON, INL’s fuel performance simulation code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Loss-of-Coolant Accident Analysis of a High-Burnup Pressurized Water Reactor Core Design Using Gadolinia-Doped UO 2

High-burnup and extended enrichment fuels are of interest for extending the cycle lengths of pressurized water reactors from 18 to 24 months. Changes to the fuel design and core loading scheme have potentially significant safety implications due to power distribution effects, reduced thermal conductivity, and/or increased plenum pressures due to additional burnable poison loadings. Additionally, higher burnups result in increased material degradation and risk of fuel fragmentation, relocation, and dispersal (FFRD). A representative 24-month core design using gadolinia-doped UO 2 was analyzed for performance under large-break (LB) loss-of-coolant accident (LOCA) conditions using PARCS, RELAP5-3D, and BISON. Furthermore, all considered acceptance criteria were met, with no cases exceeding the 1477 K maximum cladding temperature or the post-quench ductility oxidation limit of 17% equivalent cladding reacted. Full-core FFRD susceptibility was estimated to be approximately 455 kg, though high uncertainties exist with current approaches for computing susceptibility. Undoped fuel rods are more likely to be limiting due to higher linear heat rates. Relatively high burnup and linear heat rate rods located in second batch assemblies are of greatest safety significance during LB LOCA for this high-burnup core design.

High burnup↗

Effects of transient fission gas release on rod balloon burst behavior during a loss-of-coolant accident

The US nuclear energy industry is investigating strategies to increase the reactor operating cycle to 24 months, which would result in rod average burnups exceeding the current limit of 62 GWd/tU. To support this goal, multiphysics simulations tools and methodologies are being developed to predict the effects of this change during transient events such as loss-of-coolant accidents (LOCAs). In this work, two cladding burst correlations were used to predict cladding failure. Here, these were coupled with three transient fission gas release (tFGR) models and were implemented in the BISON fuel performance code to quantify any changes in cladding burst behavior during a large-break LOCA. First, a simple linear model was used to perform a sensitivity analysis of a single fuel rod. Second, a tFGR model available in BISON was applied to 281 fuel rods throughout the core. The third model examined was an empirical correlation based on data from the literature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiphysics Analysis of Li Cooled Divertor Substrate During Loss of Coolant Accident (LOCA)

In the ongoing study of potential designs for liquid metal (LM) plasma-facing components (PFCs), so-called “slow” and “fast” Li flow divertor concepts are under investigation. In the previous studies on design and analysis of the slow Li flow divertor and comparison with the fast Li flow divertor, the magnetohydrodynamics (MHD)/heat transfer effects of the Li flowing inside the substrate as a second coolant were comprehensively investigated under the normal steady-state operation conditions. Here, in the present study, the multiphysics analysis is extended to the unsteady abnormal divertor scenario where the Li layer on top of the substrate does not provide full coverage or even totally disappears for a certain period of time, so that the substrate becomes directly exposed to the incident high plasma heat flux. Such an unwanted event may happen regardless of the concept of the divertor and is worth detailed investigations, typically referred to as a loss of coolant accident (LOCA). To address this situation, a simplified scoping analysis is conducted first in 2-D, and then an integrated 3-D modeling is performed using a time-dependent multiphysics model in COMSOL Multiphysics that integrates LM MHD, heat transfer, and solid mechanics. The main goal is to evaluate conditions under which the major material limits, such as the maximum allowable temperature, stress, and displacement of the substrate, can still be met. It was shown that the maximum time over which the substrate of RAFM steel can retain structural integrity during the LOCA is around 0.2 ∼ 0.3 s. Any divertor concept that utilizes RAFM steel as a substrate material and liquid Li as a second coolant should take such a permitted time into consideration.

divertor↗

Thermal Design Analysis Supporting a Loss-of-Coolant-Accident Experiment at TREAT

The LOCA-SERTTA experiment vehicle along with the power and flexibility of TREAT allow for the ability to create the temperature profile evolution throughout a LOCA that would be seen in a commercial LWR. Presented in this summary are thermal-hydraulic modeling results for LOCA-SERTTA which are then compared to LOCA simulation results from a commercial LWR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling and Simulation of Fuel Dispersal During the Loss-of-Coolant Accident

This document is the compilation of the milestone portion to a larger end of project NEUP report. The executive summary of the modeling portion is provided below: In the event of cladding rupture during a postulated LOCA in a pressurized water reactor, fuel particles, along with fission gases, can be expelled into the reactor core from the fractured fuel rod, a phenomenon referred to as fuel dispersal. The initial stage of fuel dispersal is strongly influenced by the high-pressure ejection of fuel fragments, the size and geometry of the ruptured cladding, and the depressurization history of the fuel rod during the postulated LOCA transient. Depending on the location of the burst orifice relative to the quench front, the dispersal event represents an intricate three-phase flow and heat transfer phenomenon, where high-temperature fuel particles carried by the fission gases interact with the coolant within the narrow subchannels of the fuel assemblies, inducing localized phase change. Given the unique multiphysics nature of this phenomena, the current study develops a dedicated computational framework to predict the mass distribution and cooling of dispersing fuel particles, facilitating post-accident assessment and management of the fuel assemblies. Considering the scale of nuclear reactor applications, a continuum three-fluid model is proposed for simulating the transport of solids within the reactor core. With high-temperature fuel fragments within the liquid media, nucleation sites inducing phase changes are dispersed within the flow domain. Coupled with the fact that the transient dispersal event occurs on different time scales than other three-phase flow applications, this study derives a time-averaged three-fluid flow model without losing generality. The assumptions regarding the continuum treatment of the solid phase and the modeling of fuel dispersal behavior are incorporated to simplify the governing equations and derive applicable closure relations. The computational validation of the model was conducted using adiabatic experimental results obtained from ongoing research at Oregon State University, focusing on characterizing fuel dispersal behavior during simulated LOCA conditions. Settlement characteristics of the solids, quantified by the probability distribution of equivalent particles, closely matched the probability density functions reported in experimental studies. The transport of fuel particles within a scaled 5 × 5 lattice of a pressurized-water reactor rod bundle geometry was modeled through a two-fluid Eulerian framework. The required boundary conditions were evaluated from the fuel performance code BISON in a postulated large-break LOCA scenario. The modeling framework considered solid fuel particles as granular matter, interacting with the gaseous dry steam phase and fission gases through the governing interfacial momentum exchange between the participating fluids. The simulation results provided the volume fraction of the solids obtained at the bottom surface of the enclosing tank geometry. Postulated LOCA leading to fuel dispersal phenomena involves the strong coupling between fuel thermomechanics, cladding deformation, thermal-hydraulics, and fuel particle transport. Incorporation of such a strong coupling in numerical simulation is performed by coupling the multiphysics solvers. In the case of fuel dispersal, a strong coupled simulation can be performed by coupling the BISON code for fuel performance, the TRACE code for system-level thermal hydraulics, and fuel particle transport in Multiphysics Object-Oriented Simulation Environment (MOOSE). For such intricate infrastructure, the MOOSE Framework eases the data transfer between codes. The recent version of MOOSE has incorporated the Navier-Stokes module for the fluid flow. An exploratory exercise was done to gain familiarity with finite volume capabilities in the MOOSE framework to incorporate the Spalart-Allmaras (SA) turbulence model. New finite-volume and auxiliary kernels were introduced to assemble the SA transport equation, compute turbulent viscosity, and evaluate wall distance and diagnostic turbulence terms, fully integrated with existing Navier-Stokes modules. A turbulent lid-driven cavity at a Reynolds number of approximately 10,000 is used for verification. MOOSE shows the robust solver convergence and produces the turbulent features. But it underpredicts the velocity profile and turbulent quantities, emphasizing the need to develop improved SA near-wall treatments (e.g., low-Re corrections or wall functions) as a key direction for future work.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of loss-of-coolant accident for a fast-spectrum lithium-cooled nuclear reactor for space-power applications

A two-dimensional, transient, heat-transfer analysis was made to determine the temperature response in the core of a conceptual space-power nuclear reactor following a total loss of reactor coolant. With loss of coolant from the reactor, the controlling mode of heat transfer is thermal radiation. In one of the schemes considered for removing decay heat from the core, it was assumed that the 4 pi shield which surrounds the core acts as a constant-temperature sink (temperature, 700 K) for absorption of thermal radiation from the core. Results based on this scheme of heat removal show that melting of fuel in the core is possible only when the emissivity of the heat-radiating surfaces in the core is less than about 0.40. In another scheme for removing the afterheat, the core centerline fuel pin was replaced by a redundant, constant temperature, coolant channel. Based on an emissivity of 0.20 for all material surfaces in the core, the calculated maximum fuel temperature for this scheme of heat removal was 2840 K, or about 90 K less than the melting temperature of the UN fuel.

Turney, G. E.↗

In-Pile Loss of Coolant Accident Testing at TREAT

Several hot-cell based LOCA test apparatuses still exist in various institutions across the world. These facilities typically surround rods with infrared electrical heaters to simulate LOCA conditions on the cladding. Despite its utility for cladding-focused testing, the furnace-based external heating method creates an inverted temperature gradient in fuel pellets compared to a true LOCA where radioisotope decay heat generates internal heat. Capturing the correct temperature gradient is essential in simulating the thermomechanical stress in fuel pellets, and hence a crucial design parameter investigating FFRD during a postulated LOCA. This thermomechanical stress state, for which the evolution of fuel pellet centerline and cladding temperatures is a good figure of merit, was the primary parameter investigated during conception of the LOCA-SERTTA device.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MARVEL Reactor Fuel Performance Report (Rev.2)

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MARVEL Reactor Fuel Performance Report

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral LOCA fragmentation test on high-burnup fuel

Increasing the fuel burnup limit in light water reactors is sought to enhance fuel cycle economics and requires establishing a technical basis. Experimental observations of severe fuel fragmentation under loss-of-coolant-accident conditions at Halden and Studsvik had raised the need for additional considerations during the development of this technical basis. These test data suggested that the burnup threshold for high burnup fuel fragmentation may be influenced by pre-transient power. Additional loss-of-coolant-accident test data is therefore valuable to complement these tests and enhance the current state of understating. Oak Ridge National Lab has developed the Severe Accident Test Station capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident and beyond design basis accident scenarios. Severe Accident Test Station provides various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident testing, defueled oxidation quench testing, and high-temperature beyond design basis accident testing. Severe Accident Test Station has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory at Oak Ridge National Lab. Furthermore, descriptions of the in-cell re-fabrication capabilities and assembly of the loss-of-coolant-accident test train are provided. Installation of the Severe Accident Test Station system and in-cell re-fabrication restores United States capability to examine postulated and extended loss-of-coolant-accident conditions on spent fuel and cladding and provides a platform for evaluating advanced fuel and accident-tolerant fuel cladding concepts. Lastly, three in-cell integral loss-of-coolant-accident test were performed in the Severe Accident Test Station and compared to the Nuclear Regulatory Commission sponsored loss-of-coolant-accident test as well as the original loss-of-coolant-accident test performed at Argonne National Lab. Finally, the results of these tests as well as all publicly available integral loss-of-coolant-accident test were used to validate a threshold for high burnup fuel fragmentation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗