Electrical characterization of GaAs single crystal in direct support of M555 flight experiment

The exploration of several nondestructive methods of electrical characterization of semiconductor single crystals was carried out during the period ending May 1974. Two methods of obtaining the microwave skin depth, one for the mapping flat surfaces and the other for analyzing the whole surface of small single crystal wafers, were developed to the stage of working laboratory procedures. The preliminary 35 GHz data characterizing the two types of space-related single crystal surfaces, flat slices of gallium arsenide and small wafers of germanium selenide, are discussed. A third method of nondestructive mapping of donor impurity density in semiconductor surfaces by scanning with a light beam was developed for GaAs; its testing indicates reasonable precision at reasonable scan rates for GaAs surfaces at room temperature.

Castle, J. G.↗

Electrical characterization of GaAs single crystal in direct support of M555 flight experiment

An exploration of several nondestructive methods of electrical characterization of semiconductor single crystals was carried out. Two methods of obtaining the microwave skin depth, one for mapping flat surfaces and the other for analyzing the whole surface of small single crystal wafers, were developed to the stage of working laboratory procedures. The preliminary 35 GHz data characterizing the two types of space related single crystal surfaces, flat slices of gallium arsenide and small wafers of germanium selenide, are discussed. A third method of nondestructive mapping of donor impurity density in semiconductor surfaces by scanning with a light beam was developed for GaAs; its testing indicates reasonable precision at reasonable scan rates for GaAs surfaces at room temperature.

Castle, J. G.↗

Chemiluminescence and bioluminescence microbe detection

Automated biosensors for online use with NASA Water Monitoring System employs bioluminescence and chemiluminescence techniques to rapidly measure microbe contamination of water samples. System eliminates standard laboratory procedures requiring time duration of 24 hours or longer.

Taylor, R. E.↗

Microbial transformation of nucleosides

A study involving the use of coulter counter in studying the effects of neomycin on E. coli, S. aureus and A. aerogenes was completed. The purpose of this was to establish proper technique for enumeration of cells per ml. It was found that inhibitory effects on growth of E. coli and A. aerogenes, both gram negative organisms, were directly related to the concentration of neomycin used. However, in case S. aureus, a gram positive organism, a decreased inhibition was noted at higher concentrations. A paper entitled, Use of Coulter Counter in Studying Effect of Drugs on Cells in Culture 1 - Effects of Neomycin on E. coli, S. aureus and A. aerogenes, is attached in the appendix. Laboratory procedures were also established to study the effects of nucleoside antibiotic cordycepin on He La cell grown in suspension cultures.

Lamba, S. S.↗

Proof test criteria for thin walled pressure vessels

A proof test criterion for assuring minimum service life requirements for aerospace pressure vessels is provided. The criteria proposed are based on the results of several experimental programs conducted on surface flaw specimens fabricated from 2219 aluminum base and weld metal. A description is presented of the stable crack growth behavior of surface flaws during loading. Conclusions derived from an experimental program are discussed. It is found that significant stable crack growth under increasing load can occur prior to failure. However, significant variability in results can be anticipated even when carefully controlled laboratory procedures are employed.

Finger, R. W.↗

Experiment operations in Spacelab

A review is presented of laboratory procedures which are expected to be used in Life Sciences experiments on Spacelab. The impact of hypogravity on these procedures is discussed. Specimen treatments with solutions, 'snap' freezing, and micro-mass measurements are explored in detail. Potential solutions for these operational problems are offered.

Giannovario, J. A.↗

Further efforts to limit lunar internal temperatures from electrical conductivity determinations

A representative set of 18 electrical conductivity profiles consistent with lunar transfer function data in the 0.00001 to 0.001 Hz range is generated by means of a Monte Carlo procedure. Laboratory electrical conductivity vs temperature data extrapolated to lower and higher temperatures are used to convert the 18 profiles into temperature profiles for a series of radially homogeneous olivine-pyroxene mixtures ranging from 100% olivine to 100% aluminous orthopyroxene. The former yields selenotherms approaching the Ringwood-Essene solidus at depths near 500 km, while additions of the latter in concentrations greater than 15-30 vol% leads to cooler selenotherms which approach the solidus only at depths greater than about 1000 km. On the basis of independent geophysical constraints, the profile envelopes for compositions containing more than 15-30 vol% aluminous orthopyroxene are considered to be the most probable.

Hood, L. L.↗

Testing for Solar-Array Hotspots

Laboratory procedure developed for evaluting hot-spot endurance of photovoltaic modules under field-service conditions. Procedures used for qualification testing of modules.

Gonzalez, C. C.↗

Development and characterization analysis of a radar polarimeter

The interaction of electromagnetic waves with natural earth surface was of interest for many years. A particular area of interest in controlled remote sensing experiments is the phenomena of depolarization. The development stages of the radar system are documented. Also included are the laboratory procedures which provides some information about the specifications of the system. The radar system developed is termed the Radar Polarimeter System. A better insight of the operation of the RPS in terms of the newly developed technique--synthetic aperture radar system is provided. System performance in tems of radar cross section, in terms of power, and in terms of signal to noise ratio are also provided. In summary, an overview of the RPS in terms of its operation and design as well as how it will perform in the field is provided.

Bong, S.↗

Cell Maintenance Systems

Living human cells require attachment to a suitable surface and special culture conditions in order to grow. These requirements are modified and amplified when cells are taken into a weightless environment. Special handling and maintenance systems are required for routine laboratory procedures conducted in the Orbiter and in the Spacelab. Methods were developed to maintain cells in special incubators designed for the Orbiter middeck, however, electrophoresis and other experiments require cells to be harvested off of the culture substrate before they can be processed or used. The cell transport assembly (CTA) was flown on STS-8, and results show that improvements are required to maintain adequate numbers of cells in this device longer than 48 hours. The life sciences middeck centrifuge probably can be used, but modifications will be required to transfer cells from the CTA and keep the cells sterile. Automated systems such as the Skylab SO-15 flight hardware and crew operated systems are being evaluated for use on the Space Shuttle, Spacelab, and Space Station research modules.

Morrison, D. R.↗

Accuracy of the spectral and radiometric laboratory calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The laboratory procedures, algorithms, measurements, and uncertainties associated with generation of the spectral and radiometric calibration of data acquired by AVIRIS are described. AVIRIS is an airborne sensor that obtains high-spatial-resolution image data of the earth in 224 spectral channels in four spectrometers covering the range from 400 to 2450 nm. The spectral calibration of AVIRIS agrees with the in-flight data to within two nanometers, and the absolute radiometric calibration is consistent with the in-flight verification to 10 percent over the spectral range. In-flight radiometric stability as measured by five consecutive passes over the surface calibration site is reported to be between three and five percent.

Chrien, Thomas G.↗

Polybutadiene (Jumping Rubber)

This laboratory procedure starts with a violet suspension of an 'alfin' catalyst being added to a bottle containing a solution of 1,3-butadiene in pentane. The bottle is corked and shaken for several seconds. The mixture sets to a gel, and within 2 minutes the contents erupt from the bottle.

Fine, Leonard W.↗

Adenosine Monophosphate-Based Detection of Bacterial Spores

A method of rapid detection of bacterial spores is based on the discovery that a heat shock consisting of exposure to a temperature of 100 C for 10 minutes causes the complete release of adenosine monophosphate (AMP) from the spores. This method could be an alternative to the method described in the immediately preceding article. Unlike that method and related prior methods, the present method does not involve germination and cultivation; this feature is an important advantage because in cases in which the spores are those of pathogens, delays involved in germination and cultivation could increase risks of infection. Also, in comparison with other prior methods that do not involve germination, the present method affords greater sensitivity. At present, the method is embodied in a laboratory procedure, though it would be desirable to implement the method by means of a miniaturized apparatus in order to make it convenient and economical enough to encourage widespread use.

Kern, Roger G.↗

A report on laboratory performance of the spectroscopic detector arrays for SPIRE/HSO

We report the performance of the flight bolometer arrays for the Spectral and Photometric Imaging REceiver (SPIRE) instrument to be on board of the Herschel Space Observatory (HSO). We describe the test setup for the flight Bolometric Detector Assembly (BDA) that allows the characterization of its performance, both dark and optical, in one instrument’s cool down. We summarize the laboratory procedure to measure the basic bolometer parameters, optical response time, optical efficiency of bolometer and feedhorn, dark and optical noise, and the overall thermal conductance of the BDA unit. Finally, we present the test results obtained from the two flight units, Spectroscopic Long Wavelength (SLW) and Spectroscopic Short Wavelength (SSW).

Hargrave, P. C.↗

Procedures of Exercise Physiology Laboratories

This manual describes the laboratory methods used to collect flight crew physiological performance data at the Johnson Space Center. The Exercise Countermeasures Project Laboratory is a standard physiology laboratory; only the application to the study of human physiological adaptations to spaceflight is unique. In the absence of any other recently published laboratory manual, this manual should be a useful document staffs and students of other laboratories.

Bishop, Phillip A.↗

A study of the radiative effects of the 9.4- and 10.4-micron bands of carbon dioxide

The potential radiative impact of the relatively weak 9.4- and 10.4-micron bands of CO2 is investigated. A comparison of line-by-line calculations to laboratory data demonstrates that the line-by-line procedure and laboratory data typically yield comparable results; however, there are cases of substantial disagreement between the line-by-line results and the laboratory data. It is observed that the Goody narrow-band model yields band absorptances in good agreement with the reference line-by-line calculations. For application to climate models, new broadband parameterizations, are presented for the 9.4- and 10.4-micron bands of CO2. Clear-sky flux calculations demonstrate that for projected increases of CO2 the impact of the 9.4- and 10.4-micron bands is comparable to that attributed to projected increases of tropospheric ozone.

Kratz, D. P.↗