Engineering PapersSearch

SEARCH · Engineering Papers

Results for “LP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Microstructure and Mechanical Properties of Additively Manufactured Haynes 282: A Comparative Analysis between L-PBF and LP-DED Technologies

This study compares the microstructure and tensile properties of Haynes 282 fabricated using laser powder bed fusion and laser powder directed energy deposition. Both sets underwent stress-relieving, followed by hot isostatic pressing, and the standard double aging heat treatment. Tensile testing was conducted at room temperature on specimens fabricated with both technologies to evaluate and compare their tensile behaviors. Results show that the ultimate tensile and yield strengths of laser powder bed fused specimens were 18% and 57% higher, respectively than those of laser powder directed energy deposited ones, whereas the elongation to failure was similar in both. The difference in strengths is attributed to the differences in the size of ɣ' precipitates and grains, i.e., those in the LP-DED specimens being larger, whereas similar elongation to failure is attributed to the carbide debonding dominating the fracture mechanism in both batches.

Additive manufacturing

The chemical composition of the cool white dwarf LP 701-29

New observations and a new synthetic spectrum of the cool white dwarf LP 701-29 are presented. The analysis suggests that the atmosphere of this star is helium dominated, with enhanced metal abundances compared to the usual abundances of white dwarfs. The best fit is achieved with an effective temperature of 4500 K and an abundance of heavy elements (especially Ca) of the order 0.01 of the solar ratio of metals to helium.

Kapranidis, S.

Titan's Plasma Environment : 3D Hybrid Kinetic Modeling of the TA Flyby and Comparison with CAPS-ELS and RPWS LP Observations

In this report we discuss the global plasma environment of the TA flyby from the perspective of 3D hybrid modeling. In our model the background, pickup, and ionospheric ions are considered as particles, whereas the electrons are described as a fluid. In homogeneous photoionization, electron-impact ionization and charge exchange are included in our model. We also take into account the collisions between the ions and neutrals. Our modeling shows that mass loading of the background plasma (H(+), O(+)) by pick up ions H2(+), CH4(+) and N2(+) differs from theT9 encounter simulations when O(+) ions are not introduced into the background plasma. In our hybrid-modeling we use Chamberlain profiles for the atmospheric components. We also include a simple ionosphere model with average mass M=28 amu ions that were generated inside the ionosphere. Titan's interior is considered as a weakly conducting body. Special attention has been paid to comparing the simulated pickup ion density distribution with CAPS-ELS and with RPWS LP observations by the Cassini-Huygens spacecraft along theta trajectory. Our modeling shows an asymmetry of the ion density distribution and the magnetic field, including the formation of Alfven wing-like structures.

induced magnetospheres

A Super-Earth and Sub-Neptune Transiting the Late-type M Dwarf LP 791-18

Planets occur most frequently around cool dwarfs, but only a handful of specific examples are known to orbit the latest-type M stars. Using TESS photometry, we report the discovery of two planets transiting the low-mass star called LP 791-18 (identified by TESS as TOI 736). This star has spectral type M6V, effective temperature 2960 K, and radius 0.17 Rꙩ, making it the third-coolest star known to host planets. The two planets straddle the radius gap seen for smaller exoplanets; they include a 1.1Rꚛ planet on a 0.95 day orbit and a 2.3Rꚛ planet on a 5 day orbit. Because the host star is small the decrease in light during these planets' transits is fairly large (0.4% and 1.7%). This has allowed us to detect both planets' transits from ground-based photometry, refining their radii and orbital ephemerides. In the future, radial velocity observations and transmission spectroscopy can both probe these planets' bulk interior and atmospheric compositions, and additional photometric monitoring would be sensitive to even smaller transiting planets.

Ian J. M. Crossfield

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES

An Iterative Approach for Solving the SCOPF Problem Applying LP, SOCP, and NLP Subproblems

We propose to develop efficient algorithms and software for the SCOPF problem. We will employ an iterative approach that will: a) use linear subproblems and other active set filtering techniques to identify the most important contingencies and drastically reduce the SCOPF model size; b) solve SOCP relaxations of the reduced SCOPF to converge to the neighborhood of the global optimal solution and establish a lower bound on the solution, and; c) use a non-convex, nonlinear interior-point solver, Artelys Knitro, to converge quickly to the optimal solution. To identify the most effective approach, we will experiment with several techniques to identify the tradeoffs between contingency subproblem complexity and fast solvability.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Lp-stability (1 less than or equal to p less than or equal to infinity) of multivariable nonlinear time-varying feedback systems that are open-loop unstable

A class of multivariable, nonlinear time-varying feedback systems with an unstable convolution subsystem as feedforward and a time-varying nonlinear gain as feedback was considered. The impulse response of the convolution subsystem is the sum of a finite number of increasing exponentials multiplied by nonnegative powers of the time t, a term that is absolutely integrable and an infinite series of delayed impulses. The main result is a theorem. It essentially states that if the unstable convolution subsystem can be stabilized by a constant feedback gain F and if incremental gain of the difference between the nonlinear gain function and F is sufficiently small, then the nonlinear system is L(p)-stable for any p between one and infinity. Furthermore, the solutions of the nonlinear system depend continuously on the inputs in any L(p)-norm. The fixed point theorem is crucial in deriving the above theorem.

Callier, F. M.

Maximum-entropy probability distributions under Lp-norm constraints

Continuous probability density functions and discrete probability mass functions are tabulated which maximize the differential entropy or absolute entropy, respectively, among all probability distributions with a given L sub p norm (i.e., a given pth absolute moment when p is a finite integer) and unconstrained or constrained value set. Expressions for the maximum entropy are evaluated as functions of the L sub p norm. The most interesting results are obtained and plotted for unconstrained (real valued) continuous random variables and for integer valued discrete random variables. The maximum entropy expressions are obtained in closed form for unconstrained continuous random variables, and in this case there is a simple straight line relationship between the maximum differential entropy and the logarithm of the L sub p norm. Corresponding expressions for arbitrary discrete and constrained continuous random variables are given parametrically; closed form expressions are available only for special cases. However, simpler alternative bounds on the maximum entropy of integer valued discrete random variables are obtained by applying the differential entropy results to continuous random variables which approximate the integer valued random variables in a natural manner. All the results are presented in an integrated framework that includes continuous and discrete random variables, constraints on the permissible value set, and all possible values of p. Understanding such as this is useful in evaluating the performance of data compression schemes.

Dolinar, S.

Advanced Langmuir Probe (LP)

The dynamic response of the MK-2 version of the Langmuir probe amplifier was studied. The settling time of the step response is increased by: (1) stray node-to-ground capacitance at series connections between high value feedback resistors; and (2) input capacitance due to the input cable, FET switches, and input source follower. The stray node-to-ground capacitances can be reduced to tolerable levels by elevating the string of feedback resistors above the printing board. A new feedback network was considered, with promising results. The design uses resistances having much lower nominal values, thereby minimizing the effect of stray capacitances. Faster settling times can be achieved by using an operational amplifier having a higher gain-bandwidth product.

Voronka, N. R.

The presence of lysylpyridinoline in the hypertrophic cartilage of newly hatched chicks

The presence of lysylpyridinoline (LP) as a nonreducible cross-link in appreciable quantities has primarily been limited to the mineralized tissues, bone and dentin. However, the results reported here show that LP is not only present in the hypertrophic cartilage of the tibiotarsus isolated from newly hatched broiler chicks, but it is approx. 4-fold as concentrated as hydroxylysylpyridinoline (HP). Bone and articular cartilage surrounding the hypertrophic cartilage do not contain measurable quantities of LP. Purified LP has a fluorescent scan similar to purified HP and literature values, confirming that we indeed were measuring LP. Also, the cartilage lesion produced by immature chondrocytes from birds with tibial dyschondroplasia had LP but the HP:LP ratio was > 1. Thus, the low HP:LP ratio could be a marker for hypertrophic cartilage in avians.

NASA Discipline Musculoskeletal

Thin-wall Internal Channel Geometry and Surface Enhancements for Heat Exchangers using Laser Powder Directed Energy Deposition

Additive Manufacturing (AM) has offered many new design and manufacturing opportunities for components across various industries. As AM evolves there is a need to better understand outputs of the process including geometric limitations, surface texture, and post-processing surface enhancements for specific application requirements. One possible application area of AM are components using thin-wall (~1 mm) microchannel heat exchangers for subsystems across aerospace and industrial applications. Laser Powder Bed Fusion (L-PBF) is a common process for complex internal channels but the build diameter is limited to approximately 600 mm. Laser Powder Directed Energy Deposition (LP-DED) is being evaluated to produce thin-wall microchannel heat exchangers at scales beyond the L-PBF process. Successful deployment of the LP-DED technology requires characterization of geometric features from the process and potential improvements to the surface using post-processing. Surface texture, inclusive of roughness and waviness, is one of the critical attributes of AM that effects the friction factor and pressure drop within a heat exchanger and lacks data for the LP-DED process. This presentation will provide an overview of the characterization work completed of the LP-DED process for thin-walls and small channel geometry representative of various high performance alloys including NASA HR-1 and GRCop-42. An overview of the experiments conducted with varying LP-DED parameters, evaluation of various internal channel geometry, geometric build features, and resulting surface texture will be provided along with a summary of conclusions from these experiments. This study presents characterization of 2.5 mm microchannels using LP-DED, mechanisms that cause the surface texture which include powder adherence and material droop, and angled walls have a significant impact on the thickness and surface texture. Results will also be presented on various surface enhancement processes that allow for tuning of the wetting surface for friction factor, heat transfer, or fatigue life performance requirements.

Additive Manufacturing

Low-complexity wavelet filter design for image compression

Image compression algorithms based on the wavelet transform are an increasingly attractive and flexible alternative to other algorithms based on block orthogonal transforms. While the design of orthogonal wavelet filters has been studied in significant depth, the design of nonorthogonal wavelet filters, such as linear-phase (LP) filters, has not yet reached that point. Of particular interest are wavelet transforms with low complexity at the encoder. In this article, we present known and new parameterizations of the two families of LP perfect reconstruction (PR) filters. The first family is that of all PR LP filters with finite impulse response (FIR), with equal complexity at the encoder and decoder. The second family is one of LP PR filters, which are FIR at the encoder and infinite impulse response (IIR) at the decoder, i.e., with controllable encoder complexity. These parameterizations are used to optimize the subband/wavelet transform coding gain, as defined for nonorthogonal wavelet transforms. Optimal LP wavelet filters are given for low levels of encoder complexity, as well as their corresponding integer approximations, to allow for applications limited to using integer arithmetic. These optimal LP filters yield larger coding gains than orthogonal filters with an equivalent complexity. The parameterizations described in this article can be used for the optimization of any other appropriate objective function.

Majani, E.

Global Geochemical Variation on the Lunar Surface: A Three-Element Approach

We present a method for displaying the relative abundances of three important elements (Th, Fe, and Ti) on the same map projection of the lunar surface. Using Th-, Fe-, and Ti-elemental abundances from orbital geochemical data and assigning each element a primary color, a false-color map of the lunar surface was created. This approach is similar to the ternary diagram approach presented by Davis and Spudis with some important differences, discussed later. For the present maps, Th abundances were measured by the Lunar Prospector (LP) Gamma-Ray Spectrometer(GRS).The new LPGRS low-altitude dataset was used in this analysis. Iron and Ti weight percentages were based on Clementine spectral reflectance data smoothed to the LP low altitude footprint. This method of presentation was designed to aid in the location and recognition of three principal lunar compositions: ferroan anorthosite (FAN), mare basalts (MB), and the Mg suite/ KREEP-rich rocks on the lunar surface, with special emphasis on the highlands and specific impact basins. In addition to the recognition of these endmember rock compositions, this method is an attempt to examine the relationship between elemental compositions that do not conform readily to previously accepted or observed endmember rocks in various specific regions of interest, including eastern highlands regions centered on 150 deg longitude, and a northern highlands Th-rich region observed. The LP low-altitude data has full width at half-maximum spatial resolution of about 40 km. The Clementine spectral reflectance datasets were adapted using an equal-area, gaussian smoothing routine to this footprint. In addition, these datasets, reported in weight percent of FeO and of Ti02, were adjusted to Fe and Ti weight percentages. Each dataset was then assigned one of the three primary colors: blue for Th, red for Fe, and green for Ti. For each element, the data range was normalized to represent the ratio of each point to the maximum in the dataset. (To view the color table, go to http://cass.jsc.nasa.gov/meetings/moon99/pdf/8033.pdf.) The full range of lunar longitudes is represented, but due to the lack of coverage of the Clementine data for latitudes > 70 deg and <-70 deg, the data for these regions is excluded. The differences between this approach and the ternary diagram approach of Davis and Spudis eliminate some of the uncertainty and ambiguity of the ternary diagram approach. Rather than using a ratio of Th to Ti normalized to CI chondritic ratios, and a ternary diagram with ternary apexes located at specific endmember compositional values, elemental compositions were used independently, eliminating the errors resulting from dividing numbers that can have high uncertainties, especially at low concentration. The three elements used in this method of presentation were chosen for several reasons. One reason for the inclusion of Th in this study is that it is an accurate indicator of KREEP. Iron and Ti concentrations are both low in highland regolith, causing any small fluctuations in Th to stand out very well. In addition, Fe and Ti are good compositional indicators of different mare basalts. Mixed with red for Fe, the green for Ti produces a yellow signal in high-Ti basalts. While universally high in Fe relative to the surrounding highlands, mare basalts have a diverse range of Ti values, making Ti concentration a valuable asset to the classification and identification of different basalt types. Finally, an important constraint in element selection is the availability of the global data, both from LP and Clementine results. Data for Th, Fe, and Ti are among the highest quality of existing lunar remote-sensing data. In addition, LP data for Fe and Ti will become available, enabling these data to be incorporated into the analysis. Using upper-limit values for end member rock compositions calculated from Korotev et al., attempts were made to locate the different endmember compositions of terranes on this diagram. Most strikingly, ferroan anorthosite (Th < and = 0.37 micro g/g; Fe (wt%)< and =2.29; Ti (wt%) < and = 0.22), which should appear as an almost black, reddish color, does not appear on the diagram at any noticeable frequency. Based on this analysis, the suggestion of extensive FAN regions on the lunar surface is not strong, especially at the presently accepted values for Fe and Th. However, to make sure this effect is not due to systematic errors, a thorough investigation of the precision, accuracy, and uncertainties of the Fe, Ti, and Th abundances needs to be carried out, especially at low concentrations. A particular region of interest is an area of high Th concentrations relative to Fe and Ti content north and east of Humboldtianum Crater. First observed by Lawrence et al., this region does not coincide with any visible impact structure and comprises one of the closest approximations to pure blue (high Th, very low Ti and Fe) on the lunar surface. Such an elemental composition does not lend itself readily to classification, and presents something of an anomaly. More detailed analysis of this region is needed to understand its structure and origin. There seems to be a longitudinal asymmetry in the Th concentrations of the highlands regolith. High-Th, low-Ti, and Fe regions are located between 135 deg and 180 deg longitude and between -30 deg and +30 deg latitude. While the Th levels are not high enough to attract attention in a single elemental display, the variation in the abundance of Th relative to Fe and Ti abundances can be clearly seen. The composition that these data suggest is not well represented in the sample return suite. In addition, these regions were largely missed by the Apollo orbital ground tracks, which only covered the outer edge of the areas of interest. The LP orbital Th data represent the first information about the Th concentrations in these regions of the highlands. Additional information contained in original.

Thomsen, D. R.

Different Levels of Eccentric Resistance during Eight Weeks of Training Affect Muscle Strength and Lean Tissue Mass

Coupling concentric and eccentric muscle contractions appears to be important in the development of muscle strength and hypertrophy. The interim Resistive Exercise Device (iRED) currently used aboard the International Space Station does not seem to be as effective as free weight training in ambulatory subjects and has not completely protected against muscular deconditioning due to space flight. The lack of protection during space flight could be caused by iRED's proportionally lower eccentric resistance (60-70%) compared to concentric resistance. PURPOSE: To determine the effects of 8 wks of lower body resistive exercise training using five levels of eccentric resistance on muscle strength and lean tissue mass. METHODS: Forty untrained males (34.9 +/- 7 yrs, 80.9 +/- 9.8 kg, 178.2 +/- 7.1 cm; mean +/- SD) completed three 1-repetition maximum (1-RM) strength tests for both the supine leg press (LP) and supine heel raise (HR) prior to training; subjects were matched for LP strength and randomly assigned to one of five training groups. Concentric load (% 1-RM) was constant across groups during training, but each group trained with different levels of eccentric load (0%, 33%, 66%, 100%, or 138% of concentric). Subjects trained 3 d / wk for 8 wks using a periodized program for LP and HR based on percentages of the highest pre-training 1-RM. LP and HR 1-RM and leg lean mass (LLM; assessed by DEXA) were measured pre- and post-training. A two-way ANOVA was used to analyze all dependent measures. Tukey's post hoc tests were used to test significant main effects. Within group pre- to post-training changes were compared using paired t-tests with a Bonferroni adjustment. Statistical significance was set a priori at p 0.05. All data are expressed as mean +/- SE. RESULTS: LP 1-RM strength increased significantly in all groups pre- to post-training. The 138% group increase (20.1 +/- 3.7%) was significantly greater than the 0% (7.9 +/- 2.8%), 33% (7.7 +/- 4.6%), and 66% (7.5 +/- 4.3%) groups. All groups significantly increased HR strength pre- to posttraining (33%: 7.5 +/- 6.1%; 66%: 6.6 +/- 3.7%; 100%: 12.2 +/- 1.8%; 138%: 11.0 +/- 6.4%) except for the 0% (4.9 +/- 9.1%) group. There were no differences between groups. LLM increased significantly pre- to post-training in only the 138% group; there were no differences between groups. CONCLUSIONS: Eight wks of lower body resistive exercise training with eccentric overload resulted in greater increases in LP strength than training with eccentric loads of 66% or less. Post-training HR strength was not affected by eccentric training load, perhaps because of the predominance of Type I fibers typical in the gastrocnemius. Only 138% eccentric training significantly increased LLM. PRACTICAL APPLICATIONS: For athletes or others desiring to maximize muscle strength and hypertrophy gains, training with eccentric loads greater than 100% of concentric resistance will provide greater increases in muscle strength and lean tissue mass in some muscle groups. In a rehabilitation or geriatric exercise setting that places primary emphasis on program adherence and moderate strength gains, training with an eccentric underload may provide strength increases comparable to those of traditional 1:1 training but with less muscle soreness and physiologic insult to the patient, but this has yet to be proven.

English, K. L.

Decade-Long Ozone Profile Record from Suomi NPP OMPS Limb Profiler: Assessment of Version 2.6 Data

We evaluate a decadal ozone profile record derived from the Suomi National Polar-orbiting Partnership (SNPP) Ozone Mapping and Profiler Suite (OMPS) Limb Profiler (LP) satellite instrument. In 2023, the OMPS LP data were re-processed with the new version 2.6 retrieval algorithm that combines measurements from the ultraviolet (UV) and visible (VIS) parts of the spectra and employs the second order Tikhonov regularization to retrieve a single vertical ozone profile between 12.5 km (or cloud tops) and 57.5 km with the vertical resolution of about 1.9 - 2.5 km between 20-55 km. The algorithm uses radiances measured at six UV ozone-sensitive wavelengths (295, 302, 306, 312, 317 and 322 nm) paired with 353 nm, and one VIS wavelength at 606 nm combined with 510 nm and 675 nm to form a triplet. Each wavelength pair or triplet is used over a limited range of tangent altitudes where the sensitivity to ozone changes are strongest. A new implemented aerosol correction scheme is based on a gamma-function particle size distribution. Numerous calibration changes that affected ozone retrievals were also applied to measured LP radiances, including updates in altitude registration, radiometric calibration, stray light, and spectral registration. The key version 2.6 improvement is the reduction in relative drifts between LP ozone and correlative measurements, linked previously to a drift in the version 2.5 LP altitude registration. We compare LP ozone profiles with those from Aura Microwave Limb Sensor (MLS) to quantify ozone changes in version 2.6.

Limb scattering