Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIPA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High-resolution thermal-conductivity measurements near the lambda point of helium

Measurements of the thermal conductivity of helium in the region from 6 x 10 to the -8th to 6 x 10 to the -4th K above the lambda point at the vapor pressure are reported. Within 5 x 10 to the -6th K of the transition conductivity values are found significantly lower than expected on the basis of theoretical extrapolations from previous experiments. When the parameter Rk is calculated, a maximum about 2 x 10 to the -6th K above the transition is found, in disagreement with the predictions of the two-loop dynamic renormalization-group theory. The uncertainties in the results in this region are discussed in detail.

Lipa, J. A.↗

The lambda point experiment in microgravity

An experiment for performing high-resolution measurements of the heat capacity singularity at the lambda point of helium in microgravity conditions is described. By obtaining such measurements in space, it is expected that the intrinsic distortion of the transition would be reduced by at least two orders of magnitude, allowing the theory of cooperative phase transitions to be more effectively tested. Technology developments for the lambda point experiment include a new high-resolution thermometer, an advanced thermal control system, and a reusable flight-qualified superfluid helium dewar.

Lipa, J. A.↗

The lambda point experiment in microgravity

The motivation and potential for performing very high resolution measurements of the heat capacity singularity at the lambda point of helium in microgravity conditions was briefly discussed. It is clear that tests extending deep into the asymptotic region can be performed, where the theoretical predictions take on their simplest form. This advantageous situation should lead to a major improvement in the understanding of the range of applicability of current theoretical ideas in this field. The lambda transition holds out the prospect of giving the maximum advance of any system, and with the application of cryogenic techniques, the potential of this system can be realized. The technology for the initial experiments is already developed, and results could be obtained in 1990.

Lipa, J. A.↗

High accuracy thermal conductivity measurements near the lambda transition of helium with very high temperature resolution

Over the past few years extensive thermal conductivity measurements near the lambda point of helium were made. The original goal of measuring the thermal conductivity with a resolution of t = T/T sub lambda -1 of 3 x 10(-8) was reached, but with somewhat less accuracy than was hoped. Subtle effects in the apparatus near the transition were observed which reduced the ability to interpret the results. Nevertheless, for resolution of t is greater than or equal to 10(-7) reliable data was obtained, extending previous measurements by more than an order of magnitude. Deviations from theoretical predictions were observed for t is less than or equal to 3 x 10(-6) leading to the question of the validity of the present renormalization group analysis of transport properties, at least for the case of helium. This anomaly led to closer examination of the boundary effects in the measurements. During the experiments a totally unexpected effect in the very dilute He-3 - He-4 mixtures was observed which led to the explanation of the anomalous results. The concentration dependence of the thermal conductivity near T sub lambda in the superfluid phase was found to deviate strongly from the predictions. The results gave an independent verification of this behavior and caused reanalysis of the Khalatnikov theory of hydrodynamics of the mixtures. An alternative solution was found which is in better agreement with the experiment.

Fairbank, William M.↗

Thermal conductivity and Kapitza boundary resistance of He-4 near T(gamma)

The preliminary results of high resolution measurements of the thermal conductivity of He-4 in a cell with a nominal 1 mm gap are reported and compared with previous results obtained with a 2 mm gap. The temperature dependence of the conductivity was found to be similar for both cells, indicating that size and boundary effects are well controlled. The detailed behavior of the Kapitza resistance just below T(gamma) is also reported.

Chui, T. C. P.↗

Thermal diffusive conductivity of dilute superfluid (He-3)-(He-4) mixtures

A new technique is described for measuring the effective thermal conductivity of superfluid (He-3)-(He-4) mixtures. The results confirm the large departures from hydrodynamic theory reported previously. The analysis suggests that the measured conductivity is the finite thermal diffusive conductivity of superfluid helium in the absence of counterflow. This conductivity need not diverge in the limit of small He-3 concentration.

Chui, T. C. P.↗

Temperature fluctuations in the canonical ensemble

We report the first quantitative measurements of spontaneous temperature fluctuations in a physical system well modeled by a canonical ensemble. Using superconducting magnetometers and a carefully controlled thermal environment, we have measured the noise spectra of paramagnetic salt thermometers that were coupled to thermal reservoirs at 2 K. The noise spectra were found to be in very good agreement with the predictions of the fluctuation-dissipation theorem. Our observations are at variance with some interpretations of fluctuations in the canonical ensemble.

Chui, T. C. P.↗

Status of the cryogenic inertial reference system for the Gravity Probe B mission

We describe the status of the development and testing program for the inertial reference system for the Gravity Probe B gyroscopes. The gyroscope housings are attached to a cryogenic telescope with a 14 cm aperture that continuously points at a guide star. The star image is split to provide quadrant pointing information which is used to steer the spacecraft. This data is also combined with the gyro readout data to provide an absolute precession measurement. Motion of the guide star is independently checked by reference to background galaxies. Room temperature testing of a prototype telescope has been completed and preparations are being made for low temperature tests.

Lipa, J. A.↗

Evaluation of GaAs FETs for cryogenic readout

Low-frequency, low-noise, low-power cryogenic electronics to read out photodetectors is being investigated for the star-tracking telescope of the Gravity Probe B spacecraft. We report our initial findings from evaluating more than 20 types of GaAs FETs, both commercial and non-commercial, for this application. Most exhibit useable dc characteristics at cryogenic temperatures, although gate leakage and hysteretic effects (presumably due to charge trapping) could be troublesome. Low-frequency noise (based primarily on grounded-gate measurements) at 4 K is '1/f-like' and for the quietest GaAs FETs appears to be at least as low as the lowest noise values reported for Si MOSFETs at 4 K. Further investigation is needed in several areas.

Kirschman, Randall K.↗

Heat capacity and thermal relaxation of bulk helium very near the lambda point

In October 1992 a low temperature experiment was flown on the Space Shuttle in low Earth orbit. The objective of the mission was to measure the heat capacity and thermal conductivity of helium very close to the lambda point with the smearing effect of gravity removed. We report preliminary results from the experiment, and compare them with related measurements performed on the ground. The sample was s sphere of helium 3.5 cm in diameter contained within a copper calorimeter of vey high thermal conductivity. The calorimeter was attached to a pair of high resolution paramagnetic salt thermometers with noise levels in the 10(exp -10) K range and suspended from a high stability thermal isolation system. During the mission we found that the resolution of the thermometers was degraded somewhat due to the impact of charged particles. This effect limited the useful resolution of the measurements to about two nanokelvins from the lambda point. The results reported here are limited to about ten nanokelvins from the transition.

Lipa, John A.↗

The Superconducting Cavity Stabilized Oscillator

Superconducting Cavity Stabilized Oscillators (SCSOs) have produced the most stable clocks to date for integration times between 10(exp 2) and 10(exp 3) seconds, achieving a fractional frequency stability of 2 x 10(exp -16) for a sampling time of 100 s. The principal contributors to cavity frequency variations are: (1) acceleration effects due to gravity and vibrations; (2) temperature variations; (3) variations in the energy stored in the cavity; and (4) noise introduced by the frequency stabilization circuit. We discuss the prospects for improvements in all these areas for both ground-based and space-based SCSOs, which may lead to SCSOs with fractional frequency stabilities below 10(exp -17). SCSOs of this frequency stability will be useful for testing fundamental physical principles.

Turneaure, J. P.↗

Study the Effects of Charged Particle Radiation on Gravitational Sensors in Space

Space-flight charging of free floating masses poses an unusual problem-- how can one control charge on the object without exerting a significant force on it? One approach is to make contact to the object with a fine wire. However, for many precision applications no physical contact is permissible, so charge must be conveyed in, a more sophisticated manner. One method has already been developed: Gravitational Probe B (GP-B) uses an ultraviolet photo-emission system described in ref 1. This system meets the experiment requirements, yet poses a number of constraints, including high power dissipation (approximately 10 W peak, approximately 1 W average), low current output (approximately 10(exp -13) A), and potential reliability problems associated with fiber optics system and the UV source. The aim of the current research is to improve this situation and, if possible, develop a more rugged and lower power alternative, usable in a wide range of situations. An potential alternative to the UV electron source is a Spindt-type field emission cathode. These consist of an array of extremely sharp silicon tips mounted in a standard IC package with provision for biasing them relative to the case potential. They are attractive as electron sources for space applications due to their low power consumption (10(exp -5) W), high current levels (10(exp -9) to 10(exp -5) A), and the absence of mechanical switching. Unfortunately, existing cathodes require special handling to avoid contamination and gas absorption. These contaminants can cause severe current fluctuations and eventual destruction of the cathode tips. Another potential drawback is the absence of any data indicating the possibility of bipolar current flow. This capability is needed because of the large uncertainties in the net charge transfer from cosmic rays to a free floating mass in space. More recent devices reduce the current fluctuations and destructive arcing by mounting the tips on a resistive substrate rather than a good conductor. This effectively wires a resistor to each individual tip, providing a current limit and thus greatly reducing the possibility of destructive arcing through an individual tip. An issue with this resistive layer is its range of operating temperatures. From the experience with the GP-B system, we hypothesized about using secondary electron emission for control of net charge transfer to an object. An important goal of the testing described below was to demonstrate the ability to apply both positive and negative charges to the test object from a single emitter.

Lipa, John A.↗

Preliminary Results from the Confined Helium Experiment

We describe the preliminary results from an experiment to measure the heat capacity of helium confined within a stack of evenly spaced silicon plates at temperatures very close to the superfluid transition. The resolution of the heat capacity measurements was generally about 5x10 (exp -9)K, allowing the finite size peak to be mapped in detail. In addition, wide range data containing information on the behavior of the surface specific heat was collected. The preliminary analysis shows fair agreement with theory, but some discrepancies. The results can also be combined with related ground measurements on smaller length scales to perform additional tests of scaling predictions for cross-over to lower dimensional behavior. Some results in this area are also presented.

Lipa, J. A.↗

Fluid Physics and Transport Phenomena in a Simulated Reduced Gravity Environment

We describe a ground-based apparatus that allows the cancellation of gravity on a fluid using magnetic forces. The present system was designed for liquid oxygen studies over the range 0.001 - 5 g s. This fluid is an essential component of any flight mission using substantial amounts of liquid propellant, especially manned missions. The apparatus has been used to reduce the hydrostatic compression near the oxygen critical point and to demonstrate inverted phase separation. It could also be used to study pool boiling and two-phase heat transfer in Martian, Lunar or near-zero gravity, as well as phenomena such as Marangoni flow and convective instabilities. These studies would contribute directly to the reliability and optimization of the Moon and Mars flight programs.

Lipa, J.↗

Microwave Cavity Clocks On Space Station

We describe the status of a microwave cavity clock experiment to perform improved tests of Local Position Invariance and Lorentz Invariance on the International Space Station in conjunction with atomic clocks. Significant improvements over present bounds are expected in both cases. The oscillators can also be used to enhance the performance of atomic clocks at short time scales for other experiments.

Lipa, J. a.↗

Second Sound Measurements Very Near the Lambda Point

The sound was generated by wire-wound heaters embedded in the end opposite the sensor in each cavity. The superfluid density was determined from second sound measurements and the critical exponent v was obtained from fits to the data. The results from the exponent were found to be very sensitive to the treatment of systematic effects in the data.

sound measurements Lambda point superfluid↗