Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIMITING VALUES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Lubricant jet flow phenomena in spur and helical gears with modified center distances and/or addendums for out-of-mesh conditions

Out-of-mesh jet lubrication of gears was examined. The pinion impingement cycle was described briefly. An analysis was developed for the lubricant jet flow in the out-of-mesh condition. The analysis provides for the inclusion of modified center distances and modified addendums. Equations were generated for the limit values of variables necessary to remove the severe limitations to facilitate computer analysis. A computer program was designed using these limit formulas to prevent negative impingement (missing) on the pinion.

Akin, L. S.↗

Lubricant jet flow phenomena in spur and helical gears with modified center distances and/or addendums - For out-of-mesh conditions

Out-of-mesh jet lubrication of gears was examined. The pinion impingement cycle was described briefly. An analysis was developed for the lubricant jet flow in the out-of-mesh condition. The analysis provides for the inclusion of modified center distances and modified addendum. Equations were generated for the limit values of variables necessary to remove the severe limitations to facilitate computer analysis. A computer program was designed using these limit formulas to prevent negative impingement (missing) on the pinion.

Akin, L. S.↗

A method for defining down-wind evacuation areas for transportation accidents involving toxic propellant spills

Evacuation areas for accidental spills of toxic propellants along rail and highway shipping routes are defined to help local authorities reduce risks to people from excessive vapor concentrations. These criteria along with other emergency information are shown in propellant spill cards. The evacuation areas are based on current best estimates of propellant evaporation rates from various areas of spill puddles. These rates are used together with a continuous point-source, bi-normal model of plume dispersion. The rate at which the toxic plume disperses is based on a neutral atmospheric condition. This condition, which results in slow plume dispersion, represents the widest range of weather parameters which could occur during the day and nighttime periods. Evacuation areas are defined by the ground level boundaries of the plume within which the concentrations exceed the toxic Threshold Limit Value (TLV) or in some cases the Emergency Exposure Limit (EEL).

Siewert, R. D.↗

Method and system for monitoring and displaying engine performance parameters

The invention is a method and system for monitoring and directly displaying the actual thrust produced by a jet aircraft engine under determined operating conditions and the available thrust and predicted (commanded) thrust of a functional model of an ideal engine under the same determined operating conditions. A first set of actual value output signals representative of a plurality of actual performance parameters of the engine under the determined operating conditions is generated and compared with a second set of predicted value output signals representative of the predicted value of corresponding performance parameters of a functional model of the engine under the determined operating conditions to produce a third set of difference value output signals within a range of normal, caution, or warning limit values. A thrust indicator displays when any one of the actual value output signals is in the warning range while shaping function means shape each of the respective difference output signals as each approaches the limit of the respective normal, caution, and warning range limits.

Abbott, Terence S.↗

Stress concentration in a cylindrical shell containing a circular hole.

The state of stress in a cylindrical shell containing a circular cutout was determined for axial tension, torsion, and internal pressure loading. The solution was obtained for the shallow shell equations by a variational method. The results were expressed in terms of a nondimensional curvature parameter which was a function of shell radius, shell thickness, and hole radius. The function chosen for the solution was such that when the radius of the cylindrical shell approaches infinity, the flat-plate solution was obtained. The results are compared with solutions obtained by more rigorous analytical methods, and with some experimental results. For small values of the curvature parameter, the agreement is good. For higher values of the curvature parameter, the present solutions indicate a limiting value of stress concentration, which is in contrast to previous results.

Adams, N. J. I.↗

Towards a 700 mV silicon solar cell

The key to improved silicon solar cell performance lies in increasing cell open circuit voltage. Not only does improved voltage direclty increase cell efficiency, but it also increases the limiting value of fill factor and decreases the temperature sensitivity of the cell. Limits on attainable open circuit voltage are not well defined. A thermodynamic limit of 850 mV exists for black body silicon cells, with 700 mV long regarded as a practical limit. This paper describes experimental work which has resulted in experimental devices with open circuit voltages approaching 700 mV. Values up to 694 (AM0, 25 C) have been demonstrated. The cells are similar in structure to conventional p-n junction cells, but particular attention is paid to passivating the entire top surface of the cell, including regions under the top contact.

Green, M. A.↗

Lessons and Recommendations for Board-Level Testing with Protons

Protons with sufficiently high energy, provided in a broad field covering on the order of 0.1m2 can be used to perform board-level testing for single event effects (SEE). NASA has used this approach for board-level testing over the last 20 years. Although many difficulties inherent in SEE testing are simplified when using a board-level test, including reduced cost, the method is inherently risky because of the limited value of the collected data and the potential to make critical mistakes when performing SEE testing this way, leading to data of less value. Historically, NASA’s approach to proton board-level testing has been limited to lower criticality applications. However, with users both inside and outside NASA using this method for higher levels of mission assurance, we have put together a set of lessons and recommendations to improve the value of data collected using this method. Focus areas covered include test preparation, test execution, and interpretation of results.

Guertin, Steven M.↗

CubeSat Material Limits For Design for Demise

The CubeSat form factor of nano‐satellite (a satellite with a mass between one and ten kilograms) has grown in popularity due to their ease of construction and low development and launch costs. In particular, their use as student led payload design projects has increased due to the growing number of launch opportunities. CubeSats are often deployed as secondary or tertiary payloads on most US launch vehicles or they may be deployed from the ISS. The focus of this study will be on CubeSats launched from the ISS. From a space safety standpoint, the development and deployment processes for CubeSats differ significantly from that of most satellites. For large satellites, extensive design reviews and documentation are completed, including assessing requirements associated with reentry survivability. Typical CubeSat missions selected for ISS deployment have a less rigorous review process that may not evaluate aspects beyond overall design feasibility. CubeSat design teams often do not have the resources to ensure their design is compliant with reentry risk requirements. A study was conducted to examine methods to easily identify the maximum amount of a given material that can be used in the construction of a CubeSats without posing harm to persons on the ground. The results demonstrate that there is not a general equation or relationship that can be used for all materials; instead a limiting value must be defined for each unique material. In addition, the specific limits found for a number of generic materials that have been previously used as benchmarking materials for reentry survivability analysis tool comparison will be discussed.

Kelley, R. L.↗

CubeSat Material Limits for Design for Demise

The CubeSat form factor of nano-satellite (a satellite with a mass between one and ten kilograms) has grown in popularity due to their ease of construction and low development and launch costs. In particular, their use as student led payload design projects has increased due to the growing number of launch opportunities. CubeSats are often deployed as secondary or tertiary payloads on most US launch vehicles or they may be deployed from the ISS. The focus of this study will be on CubeSats launched from the ISS. From a space safety standpoint, the development and deployment processes for CubeSats differ significantly from that of most satellites. For large satellites, extensive design reviews and documentation are completed, including assessing requirements associated with re-entry survivability. Typical CubeSat missions selected for ISS deployment have a less rigorous review process that may not evaluate aspects beyond overall design feasibility. CubeSat design teams often do not have the resources to ensure their design is compliant with re-entry risk requirements. A study was conducted to examine methods to easily identify the maximum amount of a given material that can be used in the construction of a CubeSats without posing harm to persons on the ground. The results demonstrate that there is not a general equation or relationship that can be used for all materials; instead a limiting value must be defined for each unique material. In addition, the specific limits found for a number of generic materials that have been previously used as benchmarking materials for re-entry survivability analysis tool comparison will be discussed.

Kelley, R. L.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗

A thermal-capillary mechanism for a growth rate limit in edge-defined film-fed growth of silicon sheets

Capillarity, acting to set the shape of the melt/gas interfaces, and heat transfer can interact to cause limits to steady-state growth of thin silicon sheets by the Edge-Defined Film-Fed Growth (EFG) method. A finite-element/Newton solution method for a two-dimensional thermal-capillary model of EFG is used to show that limiting values of pull rate exist beyond which steady-state growth is impossible. The pull rate limit is also predicted by a one-dimensional heat transfer model valid when the die sides and menisci are almost parallel and when the thermal conductivities of melt, crystal, and die are all equal. Both the one- and two-dimensional heat transfer models show that heat loss from the melt is dominated by conduction into the crystal and slow heat release to the ambient along the length of the ribbon. The limiting pull rate results from the reduced efficiency of conduction through the melt caused by the curvature of the meniscus which increases height of the die top above the level of the melt. Thermal-capillary limits are predicted for both positive and negative pressure differences across the meniscus.

Thomas, P. D.↗

Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

Waller, Jess M.↗

Aviation turbine fuel properties and their trends

This paper is an examination of published Jet A inspection data covering selected property distributions, averages, and trends for the period from 1969 to 1979. Yearly median values of aromatics, mercaptan sulfur content, 10-percent distillation temperature, smoke point, and freezing point are changing with time, approaching their specification limit values, particularly in the last three years. A near-specification property is defined as one within a stated tolerance band around the specification limit. On this basis, most fuel samples have one to three near-specification properties, the most common being aromatics, smoke point, and freezing point.

Friedman, R.↗

Thermal detectors for X-ray astronomy

The characteristics of an 'ideal' spectrometer for X-ray astronomy are discussed. Special attention is given to the development of new thermal detectors (calorimeters) for the AXAF, which are based on the conversion of the energy of a single X-ray photon entirely into heat. The results obtained so far yielded the FWHM value of 17 eV at 100 mK, but the values for each of the contributing noise components measured separately were less than 10 eV, suggesting that the limiting value for AXAF will be better than 10 eV. A summary of the expected parameters for an AXAF calorimeter is presented.

Holt, Stephen S.↗

Sunlight absorption by aerosols in Jupiter's upper atmosphere

The amount of sunlight deposited in the Jovian upper atmosphere is estimated from reflectivity measurements at 2400 A by the Voyager 2 Photopolarimeter experiment and at visible and near-IR wavelengths observed by Pioneer 10 and ground-based instruments. Zero to about one percent of the incident energy is absorbed at altitudes above the 100 mbar level in models with mean values for haze optical depth and single scattering albedo. Several percent of the incident energy could be absorbed, if limiting values are used, and if an additional absorbing layer is incorporated below the high altitude haze in Pioneer models. Maximum absorption occurs at the edge of the polar regions near + or - 65 deg latitude. Most of the absorbed energy is derived from visible and near-IR radiation rather than UV radiation.

West, R. A.↗

The limits of palaeontological knowledge: finding the gold among the dross

Palaeontological interpretation rests on two interwoven sets of comparisons with the modern world. Palaeobiological interpretation relies on the placement of fossils within a phylogenetic and functional framework based primarily on the comparative biology of living organisms. Analogy to currently observable chemical, physical and taphonomic processes enables palaeoenvironmental inferences to be drawn from geological data. In older rocks, comparisons with the modern Earth can become tenuous, limiting palaeontological interpretation. The problem reaches its apogee in Archaean successions, yet pursuit of multiple lines of evidence establishes that complex microbial communities, fuelled by autotrophy and, likely, photoautotrophy, existed 3500 million years ago. Although Archaean palaeontology has to date focused on silicified coastal sediments, improved understanding of Earth's earliest biosphere may depend on the development of alternative environmental and taphonomic analogies. Spring precipitates and hydrothermal metal deposits are promising candidates. Terrestrial organisms may be of limited value in interpreting such fossils as may be found on Mars, although some points of comparison could prove general. Given limited opportunities for exploration, proper choice of environmental analogy is critical. Spring precipitates constitute excellent deposits for addressing questions of biology on another planet.

NASA Discipline Exobiology↗

Efficiency of tandem solar cell systems as function of temperature and solar energy concentration ratio

The results of a comprehensive theoretical analysis of tandem photovoltaic solar cells as a function of temperature and solar concentration ratio are presented. The overall efficiencies of tandem cell stacks consisting of as many as 24 cells having gaps in the 0.7 to 3.6 eV range were calculated for temperatures of 200, 300, 400, and 500 K and for illumination by an AMO solar spectrum having concentration ratios of 1, 100, 500, and 1000 suns. For ideal diodes (A = B = 1), the calculations show that the optimized overall efficiency has a limiting value eta sub opt of approximately 70 percent for T = 200 K and C = 1000; for T = 300 K and C = 1000, this limiting efficiency approaches 60 percent.

Gokcen, N. A.↗