Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAD 209”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

32 records · Page 2

SU-E-T-209: Independent Dose Calculation in FFF Modulated Fields with Pencil Beam Kernels Obtained by Deconvolution

Purpose: To obtain the pencil beam kernels that characterize a megavoltage photon beam generated in a FFF linac by experimental measurements, and to apply them for dose calculation in modulated fields. Methods: Several Kodak EDR2 radiographic films were irradiated with a 10 MV FFF photon beam from a Varian True Beam (Varian Medical Systems, Palo Alto, CA) linac, at the depths of 5, 10, 15, and 20cm in polystyrene (RW3 water equivalent phantom, PTW Freiburg, Germany). The irradiation field was a 50 mm diameter circular field, collimated with a lead block. Measured dose leads to the kernel characterization, assuming that the energy fluence exiting the linac head and further collimated is originated on a point source. The three-dimensional kernel was obtained by deconvolution at each depth using the Hankel transform. A correction on the low dose part of the kernel was performed to reproduce accurately the experimental output factors. The kernels were used to calculate modulated dose distributions in six modulated fields and compared through the gamma index to their absolute dose measured by film in the RW3 phantom. Results: The resulting kernels properly characterize the global beam penumbra. The output factor-based correction was carried out adding the amount of signal necessary to reproduce the experimental output factor in steps of 2mm, starting at a radius of 4mm. There the kernel signal was in all cases below 10% of its maximum value. With this correction, the number of points that pass the gamma index criteria (3%, 3mm) in the modulated fields for all cases are at least 99.6% of the total number of points. Conclusion: A system for independent dose calculations in modulated fields from FFF beams has been developed. Pencil beam kernels were obtained and their ability to accurately calculate dose in homogeneous media was demonstrated.

07 ISOTOPE AND RADIATION SOURCES↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-11) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-1) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

SU-F-T-209: Multicriteria Optimization Algorithm for Intensity Modulated Radiation Therapy Using Pencil Proton Beam Scanning

Purpose: To provide a multicriteria optimization algorithm for intensity modulated radiation therapy using pencil proton beam scanning. Methods: Intensity modulated radiation therapy using pencil proton beam scanning requires efficient optimization algorithms to overcome the uncertainties in the Bragg peaks locations. This work is focused on optimization algorithms that are based on Monte Carlo simulation of the treatment planning and use the weights and the dose volume histogram (DVH) control points to steer toward desired plans. The proton beam treatment planning process based on single objective optimization (representing a weighted sum of multiple objectives) usually leads to time-consuming iterations involving treatment planning team members. We proved a time efficient multicriteria optimization algorithm that is developed to run on NVIDIA GPU (Graphical Processing Units) cluster. The multicriteria optimization algorithm running time benefits from up-sampling of the CT voxel size of the calculations without loss of fidelity. Results: We will present preliminary results of Multicriteria optimization for intensity modulated proton therapy based on DVH control points. The results will show optimization results of a phantom case and a brain tumor case. Conclusion: The multicriteria optimization of the intensity modulated radiation therapy using pencil proton beam scanning provides a novel tool for treatment planning. Work support by a grant from Varian Inc.

60 APPLIED LIFE SCIENCES↗

Nuclear Data Sheets for A=266,270,274,278,282,286,290,294,298☆

Spectroscopic information such as production, identification, half-lives, decay modes and possible excited states for experimentally known nuclides of mass numbers 266, 270, 274, 278, 282, 286, 290, 294, and 298 are presented together with the recommended values, superseding information and data in the previous ENSDF and NDS evaluation by 2005Gu33. No nuclides have yet been identified for A=302. In the last 14 years, large amounts of new and definitive data on the superheavy nuclides (SHN) have become available, thus changing almost entirely the landscape of nuclear data in this mass region, as also indicated by a number of recent review articles: 2017Og01, 2016Ho09, 2016Ho06 (for fission barriers), 2015Og05, 2015Og07, 2015Mo25, 2015OgZX, 2013Th02, and 2011Og07. See 2016Ka49 for IUPAC technical discussions for the discovery of Z=117 (Ts), Z=115 (Mc), Z=113 (Nh), 2001Ka70 and 2003Ka71 for Z=110-112, 2011Ba54 for Z≥113, 2009Ba62 for Z=112, and 2016Ka50 for Z=118 (Og). A special issue of Nuclear Physics A444 (2015) is devoted to research on superheavy elements (SHE) with 27 articles. In particular, see article by 2015Ko20 on mass spectrometric searches for superheavy elements in terrestrial matter. See also Proceedings of Nobel Symposium NS160 ‘Chemistry and Physics of Heavy and Superheavy Elements’ published in Eur. Phys. Jour. Web of Conferences 131 (2016), in particular 2016UtZZ, 2016DmZZ and 2016HoZY. See also 2016DuZX for future prospects of discovery of elements beyond Z=118 A=266: {sup 266}Db, {sup 266}Sg, {sup 266}Bh, {sup 266}Hs and {sup 266}Mt are the experimentally identified nuclides with A=266. Identification of {sup 266}Lr from α decay of {sup 270}Db has been proposed by 2014Kh04 from experiments at GSI, but complete details and analyses of all the four decay chains reported in this experiment have not yet been published, and discussion in 2015Og05 review article considering their work from Dubna (2013Og04, 2011Og04) and from GSI (2014Kh04) still concluded that {sup 270}Db decayed dominantly by SF mode, in contrast with dominant α decay mode proposed by 2014Kh04. Experiments carried out at FLNR-JINR-Dubna in collaboration with LLNL and ORNL, GSI-SHIP facility, RIKEN, and LBNL facilities: {sup 266}Db from the α-decay of {sup 282}Nh in two correlated decay chains at Dubna; {sup 266}Sg as α-daughter of {sup 270}Hs in 12 correlated decay chains at Dubna and GSI; {sup 266}Bh in α decay of {sup 278}Nh in three correlated decay chains observed at RIKEN, and also directly with one event in {sup 249}Bk({sup 22}Ne,5n) at LBNL, and with four events in {sup 243}Am({sup 26}Mg,3n) at HIRFL-Lanzhou; {sup 266}Hs as α-daughter of {sup 270}Ds at GSI in two different experiments, six correlated decays in the first, and 25 decay chains in the second experiment, the analysis of which has not been fully reported as yet; and {sup 266}Mt directly in {sup 209}Bi({sup 58}Fe,n) reaction at GSI in two different experiments, observing three events in the first experiment and 12 events in the second, also produced in {sup 208}Pb({sup 59}Co,n) reaction at LBNL, observing five correlated decay chains. See also 2000Ho27 for discussion on {sup 266}Sg and {sup 266}Mt. A=270: {sup 270}Db, {sup 270}Bh, {sup 270}Hs, {sup 270}Mt and {sup 270}Ds are the experimentally identified nuclides with A=270 are presented. Experiments carried out at FLNR-JINR-Dubna in collaboration with LLNL and ORNL, GSI-SHIP facility, and RIKEN: {sup 270}Db from the decay of {sup 294}Ts in six correlated decay chains at Dubna and GSI; {sup 270}Bh as α great-granddaughter of {sup 282}Nh in two correlated decay chains observed at Dubna; {sup 270}Hs directly in {sup 248}Cm({sup 26}Mg,4n) reaction at GSI, and in {sup 226}Ra({sup 48}Ca,4n) reaction at Dubna; {sup 270}Mt as granddaughter of {sup 278}Ts in three correlated decay chains at RIKEN; and {sup 270}Ds directly in {sup 207}Pb({sup 64}Ni,n) at GSI in 33 correlated decay chains. A=274: {sup 274}Bh, {sup 274}Mt and {sup 274}Rg are the experimentally identified nuclides with A=274. Search for {sup 274}Ds in {sup 238}U({sup 40}Ar, 4n),E=5.7 MeV/nucleon reaction and subsequent α decays at GSI (1990Sc11) proved negative. Experiments carried out at FLNR-JINR-Dubna in collaboration with LLNL and ORNL, GSI-SHIP facility, and RIKEN: {sup 274}Bh from the decay of {sup 294}Ts in six correlated decay chains at Dubna and GSI, {sup 274}Mt produced as α daughter of {sup 282}Nh in two correlated decay chains observed at Dubna, and {sup 274}Rg as α daughter of {sup 278}Nh produced in three correlated decay chains at RIKEN. A=278: {sup 278}Mt, {sup 278}Rg and {sup 278}Nh are the experimentally identified nuclides with A=278. A very tentative evidence is provided for {sup 278}Bh and {sup 278}Hs from a chain originally observed and assigned to {sup 289}Fl by 1999Og10, but later reassigned by 2004Og10 to {sup 290}Fl, and further discussed in detail by 2016Ho09, where, based on systematics of α decays and SF half-lives, {sup 290}Fl is proposed to decay via ε mode to {sup 290}Nh, which then decays by an α chain, ending in {sup 278}Bh that decays by SF mode. Experiments carried out at FLNR-JINR-Dubna in collaboration with LLNL and ORNL labs in the USA, GSI-SHIP facility, and RIKEN: {sup 278}Mt from the decay of {sup 294}Ts in six correlated decay chains at Dubna and GSI, {sup 278}Rg produced as α daughter of {sup 282}Nh in two correlated decay chains observed at Dubna, and {sup 278}Nh produced directly in three correlated decay chains at RIKEN. A=282: {sup 282}Rg, {sup 282}Cn and {sup 282}Nh are the experimentally identified nuclides with A=282. A very tentative evidence is provided for {sup 282}Mt and {sup 282}Ds from a chain originally observed and assigned to {sup 289}Fl by 1999Og10, but later reassigned by 2004Og10 to {sup 290}Fl, and further discussed in detail by 2016Ho09, where, based on systematics of α decays and SF half-lives, {sup 290}Fl is proposed to decay via ε mode to {sup 290}Nh, which then decays by an α chain, ending in {sup 278}Bh that decays by SF mode. Experiments carried out at FLNR-Dubna, in collaboration with LLNL and ORNL labs in the USA, and at GSI-SHIP facility confirm the identification of these isotopes, {sup 282}Rg in α decay chain of {sup 294}Ts in six correlated decay chains at Dubna and GSI, {sup 282}Cn produced in four ways at Dubna: independently in one correlated decay chain, as α daughter of {sup 286}Lv in 11 correlated decay chains, as α grand-daughter of {sup 290}Lv in 12 correlated decay chains, as α great-grand daughter of {sup 294}Og in four correlated decay chains, and {sup 282}Nh produced at Dubna directly in two correlated decay chains. A=286: {sup 286}Nh and {sup 286}Fl are the only experimentally identified nuclides with A=286. A very tentative evidence is provided for {sup 286}Rg and {sup 286}Cn from a chain originally observed and assigned to {sup 289}Fl by 1999Og10, but later reassigned by 2004Og10 to {sup 290}Fl, and further discussed in detail by 2016Ho09, where, based on systematics of α decays and SF half-lives, {sup 290}Fl is proposed to decay via ε mode to {sup 290}Nh, which then decays by an α chain, ending in {sup 278}Bh that decays by SF mode. 2017Ka66 in experiments at RIKEN using GARIS separator interpret one correlated decay chain in three different ways, one involving possible production of {sup 294}Lv in {sup 248}Cm({sup 48}Ca,2n),E=261.6 MeV, and α decay to {sup 290}Fl which further decays to {sup 286}Cn. Experiments carried out at FLNR-Dubna, in collaboration with LLNL and ORNL labs in the USA, and at GSI-SHIP facility confirm the identification of these isotopes, {sup 286}Nh as α grand-daughter of {sup 294}Ts in six correlated decay chains, and {sup 286}Fl produced in three ways: independently in 11 correlated decay chains, as α daughter of {sup 290}Lv in 12 correlated decay chains, and as α grand-daughter of {sup 294}Og in four correlated decay chains. A=290: {sup 290}Mc and {sup 290}Lv are the only experimentally identified nuclides with A=290. A tentative evidence is provided for {sup 290}Nh and {sup 290}Fl from a chain originally observed and assigned to {sup 289}Fl by 1999Og10, but later reassigned by 2004Og10 to {sup 290}Fl, and further discussed in detail by 2016Ho09, where, based on systematics of α decays and SF half-lives, {sup 290}Fl is proposed to decay via ε mode to {sup 290}Nh, which then decays by an α chain, ending in {sup 278}Bh that decays by SF mode. 2017Ka66 in experiments at RIKEN using GARIS separator interpret one correlated decay chain in three different ways, one involving possible production of {sup 294}Lv in {sup 248}Cm({sup 48}Ca,2n),E=261.6 MeV, and α decay to {sup 290}Fl. Experiments carried out at FLNR-Dubna, in collaboration with LLNL and ORNL labs in the USA, and at GSI-SHIP facility confirm the identification of these isotopes, {sup 290}Mc as α daughter of {sup 294}Ts in six correlated decay chains, and {sup 290}Lv produced in two ways, independently in 14 correlated decay chains, and as α daughter of {sup 294}Og in four correlated decay chains. A=294: {sup 294}Ts and {sup 294}Og are the only experimentally identified nuclides with A=294. Experiments carried out at FLNR-Dubna, in collaboration with LLNL and ORNL labs in the USA, and at GSI-SHIP facility confirm the identification of these isotopes, with a total of six EVR-α-SF correlated decay chains observed for {sup 294}Ts and four for {sup 294}Og. Tentative identification of {sup 294}Lv is provided by 2017Ka66 from the observation one correlated event using GARIS-RIKEN facility, where this event is interpreted in three possible ways, two interpretations lead to production of {sup 293}Lv and successive odd-A nuclides of {sup 289}Fl, {sup 285}Cn and {sup 281}Ds, whereas the third prediction starts with the production of {sup 294}Lv and successive {sup 290}Fl and {sup 286}Cn nuclides. Search for {sup 294}Rg in natural gold materials (2011De03), and for {sup 294}Ds, {sup 294}Fl and {sup 294}Mc in natural Pt, Pb and Bi samples (2011De21) using accelerator mass spectroscopy (AMS) proved negative, with extremely low upper limits established. Also 1980St05 did not see any evidence for {sup 294}Ds in natural Pt sample using AMS. A=298: Search for {sup 298}120 through fusion-evaporation reaction at Dubna, and for {sup 298}Fl and {sup 298}Mc in natural Pt, Pb and Bi samples using accelerator mass spectroscopy (AMS) proved negative. Tentative assignment of three α-α-α decay chains by 2016Ho09 to {sup 299}120 in {sup 248}Cm({sup 54}Cr,3n){sup 299}120 at GSI was refuted by 2017He11, assigning these correlations to random events, instead. A=302: Fluorescent x rays from Z=120 element were observed by 2012Fr03 from compound nucleus {sup 302}120 produced in {sup 238}U({sup 64}Ni,X),E=6.6 MeV/nucleon at GANIL, and x-ray yields were measured, together with minimum average time deduced from x-ray multiplicity. The compound nucleus could decay by 3n- or 4n-channels to produce {sup 299}120 or {sup 298}120. 2012He05 and 2016Ho09 also produced {sup 302}120 compound nucleus in {sup 248}Cm({sup 54}Cr, xn){sup 302}120{sup *},E=6.035 MeV/nucleon; and {sup 238}U({sup 64}Ni,xn){sup 302}120{sup *},E=5.53 MeV/nucleon reactions using UNILAC at GSI. Three α-α-α correlated decays from {sup 248}Cm({sup 54}Cr,xn){sup 302}120{sup *} reaction were tentatively assigned by 2016Ho09 to {sup 299}120 decay, however, a detailed analysis by 2017He11 refuted this claim, ascribing these events to random sequences. There are no data tables for A=302.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-D-209-06: Head and Neck Tissue Dose From X-Ray Scatter to Physicians Performing Cardiovascular Procedures

Purpose: The purpose of this work was to characterize the spatial distribution of scatter radiation to the head and neck of a physician performing an x-ray interventional procedure and assess brain, eye lens, and carotid artery dose. Methods: Radiographic x-ray beams were tuned to match the peak energy (56 to 106 keV) and HVL (3.5 to 6.5 mm Al) of x-ray scatter originating from a patient during a fluoroscopic procedure. The radiographic beam was directed upon a Rando phantom from an inferior-left location to mimic a typical patient-operator geometric relationship. A lead-equivalent protective garment was secured to the phantom. Direct exposure Gafchromic film (XRQA2) was placed between the transverse plane layers of the head and neck region of the phantom and exposed with 4 scatter-equivalent radiographic beams. A 3×3 cm{sup 2} film placed at the left collar of the phantom was used to monitor incident dose in the position of a radiation monitoring badge. The films were converted to 2D dose distribution maps using FilmQA Pro software and an Epson 11000-XL scanner. The 2D dose distributions maps were normalized by the left collar dose and the percent of left collar dose (%LCD) was calculated for select tissues. Results: The dose maps had high dynamic range (10{sub 4}) and spatial detail. Considering all transverse planes and 4 scatter beam qualities, the median %LCD values were: whole brain 8.5%, left brain 13%, right brain 5.4%, left eye lens 67%, right eye lens 25%, left carotid artery 72%, and right carotid artery 28%. Conclusion: Scatter radiation dose to an operator can be simulated using a tuned radiographic beam and used to expose a phantom and Gafchromic film, thereby creating detailed 2D dose distribution maps. This work facilitates individualized estimation of dose to select head and neck tissues based on an operator’s radiation monitoring badge value.

60 APPLIED LIFE SCIENCES↗

Expression profile analysis of differentially expressed genes in ruptured intracranial aneurysms: In search of biomarkers

Highlights: • Bioinformatics can identify potential biomarkers of ruptured intracranial aneurysm. • BASP1, CD74, CEBPB, ECHDC2, GZMK, HLA-DRB3, KLHL3, SLC2A3 & SOCS3 affect IA rupture. • DEGs are involved in antigen processing and presentation and immune response. • Vascular brain injury affects gene expression in IA tissue. Intracranial aneurysms (IAs) result from the bulging of arterial walls secondary to several factors such as flow, vessel morphology, and genetics. Subarachnoid hemorrhage occurs when such walls rupture, leading to high disability and mortality. Despite numerous investigations pertaining to the relationship between geometric characteristics and IA rupture, only a few have obtained consistent results. This study aimed to further identify the potential genes associated with the pathogenesis of IAs, which may provide novel molecular biomarkers. We downloaded and reanalyzed six datasets, which were divided into four groups. IA walls and blood samples were screened for differentially expressed genes (DEGs); then, functional and pathway enrichment analyses were conducted. In total, 158 common DEGs were identified from Groups 1–3 and 396 genes (187 upregulated and 209 downregulated genes) were differentially expressed in Group 4. The functional analysis revealed that the DEGs were mainly associated with the major histocompatibility complex class II protein complex and antigen processing and presentation. Finally, we identified nine key genes, both in aneurysm tissue samples and blood samples, of which three were mostly associated with the progression and rupture of IAs. Bioinformatics was used to analyze the datasets of the ruptured IAs and identify potential biomarkers, which may provide information for the early detection and treatment of IAs.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-02: Beam Angle Optimization Incorporating Anatomical Heterogeneities for Pencil Beam Scanning Charged-Particle Therapy

Purpose: In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. Sensitivity of a PBS plan to lateral tissue heterogeneity can be reduced by selecting suitable beam angles. The purpose of this study is to establish a fast and accurate method of beam angle selection for PBS. Methods: The lateral tissue heterogeneity surrounding the path of respective pencil beams at a given angle was quantified with the heterogeneity number using effective density data of patients. To shorten the computation time, one dimensional dose calculation and optimization were conducted along the central axis of pencil beams originating from the scanning magnets. Calculation was performed for all fields with possible gantry and couch angles. The angles leading the minimum mean heterogeneity number was selected as the optimal beam angle. Three head and neck (H&N) cancer patients were used to evaluate our method. Dose distributions and their robustness to range and set up errors were evaluated for all tested angles, and their relation to their heterogeneity numbers were investigated. Results: Variety of heterogeneity number was clearly shown due to air cavities and bony structures in the patients. The mean value of heterogeneity number in all possible fields varied between 1.2 and 10.6 mm. By selecting a field with a lower mean value of heterogeneity number, target dose coverage and robustness of the fields were improved. Conclusion: We developed a computational method to determine a beam angle that leads good target coverage and robustness to setup errors. The developed stand-alone computation program is simple, fast, accurate and applicable for beam angle selection in PBS therapy.

60 APPLIED LIFE SCIENCES↗

Structural and electrical properties of Si- and Ti-doped Cu{sub 2}SnSe{sub 3} bulks

Silicon-doped (Cu{sub 2}(Sn{sub 1−x}Si{sub x})Se{sub 3} and titanium-doped (Cu{sub 2}(Sn{sub 1−x}Ti{sub x})Se{sub 3} at x=0, 0.05, 0.1, 0.15, and 0.2 were prepared at 550 °C for 2 h with soluble sintering aids of volatile Sb{sub 2}S{sub 3} and Te. Defect chemistry was studied by measuring structural and electrical properties of Si-doped and Ti-doped Cu{sub 2}SnSe{sub 3} (CTSe) as a function of dopant concentration. Si-doped CTSe pellets show p-type at x=0 and 0.05 and n-type at x=0.1, 0.15, and 0.2, whereas Ti-doped CTSe pellets show p-type at x=0, 0.05 and 0.1 and n-type at x=0.15 and 0.2. The lowest hole concentration of 3.6×10{sup 17} cm{sup −3} and the highest mobility of 1525 cm{sup 2} V{sup −1} s{sup −1} were obtained for the Si-doped (Cu{sub 2}(Sn{sub 1−x}Si{sub x})Se{sub 3} bulks at x=0.1 (10% Si), while they were 3.1×10{sup 17} cm{sup −3} and 813 cm{sup 2} V{sup −1} s{sup −1} for the Ti-doped CTSe bulks at x=0.15 (15% Ti), as compared to 1.1×10{sup 18} cm{sup −3} and 209 cm{sup 2} V{sup −1} s{sup −1} for undoped one. The explanations based upon antisite defects of Si-to-Sn, Ti-to-Sn, Cu-to-Sn, and Sn-to-Cu for the changes in electrical property were declared. The study in bulk Si-doped and Ti-doped CTSe is based upon defect state and is consistent and supported by the data of electrical property and lattice parameter. - Graphical abstract: Cu{sub 2}SnSe{sub 3} (CTSe) semiconductor is interesting because of its adjustable electrical properties by extrinsic doping. Si and Ti doping in CTSe leads to high carrier mobility above 800 cm{sup 2} V{sup −1} s{sup −1}. - Highlights: • Cu{sub 2}SnSe{sub 3} (CTSe) is an interesting semiconductor because of its adjustable electrical properties. • Cu(In,Ga)Se{sub 2}, on the contrary, is difficult to change its electrical properties. • Si and Ti doping can change p-CTSe to n-CTSe. • The lowest electron concentration in doped CTSe had the highest mobility above 800 cm{sup 2} V{sup −1} s{sup −1}. • The defects of Si-to-Sn, Ti-to-Sn, Cu-to-Sn, and Sn-to-Cu in Si- and Ti-doped CTSe were proposed.

36 MATERIALS SCIENCE↗

Synthesis and Characterization of Novel Poly (Acrylic Acid/Sodium Alginate/Sodium Humate) Superabsorbent Hydrogels. Part II: The Effect of SH Variation on Cu{sup 2+}, Pb{sup 2+}, Fe{sup 2+} Metal Ions, MB, CV Dye Adsorption Study

A novel superabsorbent hydrogel (SAHs) composed of (acrylic acid, sodium alginate and sodium humate) (AAc/NaAlg/SH) SAHs were tested as adsorbent for metal ions Cu{sup 2+}, Pb{sup 2+}, and Fe{sup 2+} ions as well as MB and CV dyes. The influence of SH concentration varies from 6.97, 8.04, 9.09, 10.11% and 11 wt% were designated as S{sub 1}, S{sub 2}, S{sub 3}, S{sub 4}, S{sub 5}, respectively. The synthesized superabsorbent hydrogel were used for the adsorption of Cu{sup 2+}, Pb{sup 2+}, Fe{sup 2+} and MB and CV dyes from their aqueous solutions. The binding capacity for Cu{sup 2+}, Pb{sup 2+}, Fe{sup 2+} ions were 311 mg/gm/L at 850 mg/L, 209 mg/gm/L at 850 mg/L and 197 mg/gm/L at 850 mg/L for initial ion concentration respectively and MB and CV dyes molecules were 323 mg/gm/L at 360 mg/L, 289 mg/gm/L at 360 mg/L for initial molecule concentration per gram of AAc/NaAlg/SH containing 9.09 wt% SH content. The adsorption data obeyed Langmuir sorption isotherms.

36 MATERIALS SCIENCE↗

TU-FG-209-09: Mathematical Estimation and Experimental Measurement of Patient Free-In-Air Skin Entrance Exposure During a Panoramic Dental X-Ray Procedure

Purpose: To develop a simple mathematical model for estimating the patient free-in-air skin entrance exposure (SEE) during a panoramic dental x-ray that does not require the use of a head phantom. This eliminates issues associated with phantom centering and the mounting of a detector on the phantom for routine QC testing. Methods: We used a Sirona Orthophos XG panoramic radiographic unit and a Radcal Accu-Gold system for this study. A solid state detector was attached over the slit of the Orthophos’ sensor with the help of a custom-built jig. A single measurement of the free-in-air exposure at this position was taken over a full panoramic scan. A mathematical model for estimating the SEE was developed based upon this measurement, the system geometry, x-ray field beam width, and x-ray sweep angle. To validate the model, patient geometry was simulated by a 16 cm diameter PMMA CTDI phantom centered at the machine’s isocenter. Measurements taken on the phantom’s surface were made using a solid state detector with lead backing, an ion chamber, and the ion chamber with the phantom wrapped in lead to mitigate backscatter. Measurements were taken near the start position of the tube and at 90 degrees from the start position. Results: Using the solid state detector, the average SEE was 23.5+/−0.02 mR and 55.5+/−0.08 mR at 64 kVp and 73 kVp, respectively. With the lead-wrapping, the measurements from the ion chamber matched those of the solid state detector to within 0.1%. Preliminary results gave the difference between the mathematical model and the phantom measurements to be approximately 5% at both kVps. Conclusion: Reasonable estimates of patient SEE for panoramic dental radiography can be made using a simple mathematical model without the need for a head phantom.

60 APPLIED LIFE SCIENCES↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2020

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While many projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2020, as well as data on "completed" and "withdrawn" projects for five of the ISOs (CAISO, ISO-NE, MISO, NYISO, PJM). We find that the total capacity active in the queues is growing year-over-year, with over 750 GW of generation and an estimated 200 GW of storage capacity as of the end of 2020. Solar (462 GW) accounts for a large – and growing – share of generator capacity in the queues. Substantial wind (209 GW) capacity is also in development, 29% of which is for offshore projects (61 GW). In total, about 680 GW of zero-carbon capacity is currently seeking transmission access, as is 74 GW of natural gas capacity. Hybrids now comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 159 GW of solar hybrids (primarily solar+battery) and 13 GW of wind hybrids are currently active in the queues. However, much of this proposed capacity will not ultimately be built. Among a subset of queues for which data are available, only 24% of the projects seeking connection from 2000 to 2015 have subsequently been built. Completion percentages appear to be declining, and are even lower for wind and solar than other resources. Additionally, wait times are on the rise: in four ISOs, the typical duration from connection request to commercial operation increased from ~1.9 years for projects built in 2000-2009 to ~3.5 years for those built in 2010-2020. There are growing calls for queue reform to reduce cost, lead times, and speculation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of the HAE activity in the TJ-II stellarator using a Landau closure model

The aim of this study is to analyze the stability of helical Alfvén eigenmodes (HAEs) in TJ-II discharges and the stabilizing effect of the energetic particles generated by the neutral beam injector (NBI) on pressure gradient-driven modes (PGDMs). HAE and PGDM stability is studied using the linear version of the gyro-fluid code FAR3d and the continuous structure by the STELLGAP code. First, Alfvén eigenmode (AE) and PGDM activity observed in the experiments is reproduced by the simulations, identifying unstable m/n = 4/7 − 2/3 and 7/12 − 5/8 HAEs triggered around ρ = 0.66 showing a frequency of 209 and 204 kHz, respectively, as well as 5/3 PGDM. Next, a parametric study is performed with respect to the thermal ion density and iota profile in the middle-outer plasma region to verify the robustness of the simulation results with respect to the uncertainty of experimental profiles. The analysis confirms that experimental uncertainty does not cause large deviations in the simulation results, showing the destabilization of the same HAEs for all the configurations tested. The simulations also indicate the decay of the 5/3 PGDM growth rate as the energetic particle (EP) population in the plasma increases, consistent with the experiment. Stability analysis of the n = 3, 7, 11, n = 5, 9, 13, n = 6, 10, 14, and n = 8, 12 helical families is performed with respect to the NBI operational regime for different EP energies, β as well as deposition profiles. The most unstable configuration is the radially localized on-axis NBI operation (stiff EP density profile gradients nearby the magnetic axis). Using the simulation model that reproduces the observed Alfvén activity, we extend the study to analyze NBI performance within a theoretical framework. It shows that increasing NBI voltage (which raises EP energy) leads to a degradation in NBI performance for a given power (related to EP β and their density). To achieve better NBI operation, higher voltage must be balanced with lower injection power, ensuring stable AEs while keeping the same EP β.

Plasma confinement↗