Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAD 204”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

TU-AB-204-02: Advances in C-Arm CBCT for Cardiac Interventions

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-03: Advances in CBCT for Orhtopaedics and Bone Health Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

Autoclave grid-to-rod fretting wear evaluation of a candidate cladding coating for accident-tolerant fuel

In pressurized water reactors (PWRs), water flow induced vibrations cause contact and rubbing between the fuel rods and the supporting grid, a phenomenon known as Grid-to-Rod-Fretting (GTRF). GTRF may produce progressive wear damage on the fuel claddings leading to subsequent leakage of radioactive fission products. Various accident-tolerant fuel (ATF) concepts are being developed for higher resistance to the high temperature steam and one approach is to apply a cladding coating. Here, fretting wear behavior of a candidate Cr-coating was investigated using a unique bench-scale autoclave testing rig mimicking the environment in an industrial full-assembly PWR simulator. The contact was under a realistically low load (~0.5 N) lubricated by deionized water at a temperature of 204 °C under a pressure of 20-23 bars. Results demonstrated that the Cr-coating significantly improved the cladding's wear resistance when tested against a commercial ZIRLO grid with or without pre-oxidization. In addition, the Cr-coating also reduced wear on the non-oxidized ZIRLO grid but slightly increased the wear on the pre-oxidized grid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acetylene-chromene terminated resins as high temperature thermosets

A novel phase transfer catalyzed process for the preparation of propargyl ethers has been developed. The propargyl ethers serve as precursors to a new class of thermosetting resins called acetylene-chromene terminated (ACT) resins. Heat treatment of a solution of propargyl ethers with various catalysts, followed by removal of solvent leads to the ACT resins via partial conversion of the propargyl ether groups to chromenes. This process reduces the energy content of the resin systems and reduces the amount of shrinkage found during cure. Due to the presence of the solvent the process is safe and gives rise to low viscosity products suitable for resin transfer molding and filament winding type applications. Due to the high glass transition temperature, high modulus, and low moisture uptake the cured resins display better than 232 C/wet performance. The thermal stability of the ACT resins in air at 204 C is superior to that of conventional bismaleimide resins. The resins also display excellent electrical properties.

Godschalx, J. P.↗

Grid-to-rod fretting wear study of SiC/SiC composite accident-tolerant fuel claddings using an autoclave fretting bench test

Grid-to-rod-fretting (GTRF) in pressurized water reactors (PWRs) is known to cause wear and surface damage on the fuel claddings, potentially leading to radioactive leakage. One of the accident-tolerant fuel (ATF) concepts is to use advanced cladding materials that could withstand higher temperatures. Here, we investigated the wear behavior of candidate silicon carbide (SiC)-based composite claddings with different levels of surface finish in fretting against a commercial ZIRLO alloy grid using a unique bench-scale autoclave GTRF rig. The experiments mimicked the environment in an industrial full-assembly PWR simulator. Fretting tests were conducted with a realistic load (~0.5 N) in deionized water under a pressure of 20–23 bar at 204 °C for 100 h. While the SiC/SiC composite claddings showed significantly higher wear resistance than the commercial ZIRLO alloy cladding as expected, the smoother versions experienced surprisingly higher wear than the much softer counterface, ZIRLO grid. The wear mechanism of the SiC/SiC cladding was attributed to the SiC wear debris that was trapped at the fretting interface causing both 3-body and 2-body (embedded into the grid surface) abrasion of the cladding. Rougher SiC/SiC claddings had less material loss but caused more wear on the ZIRLO grid. Finally, pre-oxidized ZIRLO grid showed better compatibility with the SiC/SiC cladding to protect both the cladding and grid as a result of reduced wear debris trapping.

36 MATERIALS SCIENCE↗

MO-FG-204-03: Using Edge-Preserving Algorithm for Significantly Improved Image-Domain Material Decomposition in Dual Energy CT

Purpose: To significantly improve dual energy CT (DECT) imaging by establishing a new theoretical framework of image-domain material decomposition with incorporation of edge-preserving techniques. Methods: The proposed algorithm, HYPR-NLM, combines the edge-preserving non-local mean filter (NLM) with the HYPR-LR (Local HighlY constrained backPRojection Reconstruction) framework. Image denoising using HYPR-LR framework depends on the noise level of the composite image which is the average of the different energy images. For DECT, the composite image is the average of high- and low-energy images. To further reduce noise, one may want to increase the window size of the filter of the HYPR-LR, leading resolution degradation. By incorporating the NLM filtering and the HYPR-LR framework, HYPR-NLM reduces the boost material decomposition noise using energy information redundancies as well as the non-local mean. We demonstrate the noise reduction and resolution preservation of the algorithm with both iodine concentration numerical phantom and clinical patient data by comparing the HYPR-NLM algorithm to the direct matrix inversion, HYPR-LR and iterative image-domain material decomposition (Iter-DECT). Results: The results show iterative material decomposition method reduces noise to the lowest level and provides improved DECT images. HYPR-NLM significantly reduces noise while preserving the accuracy of quantitative measurement and resolution. For the iodine concentration numerical phantom, the averaged noise levels are about 2.0, 0.7, 0.2 and 0.4 for direct inversion, HYPR-LR, Iter- DECT and HYPR-NLM, respectively. For the patient data, the noise levels of the water images are about 0.36, 0.16, 0.12 and 0.13 for direct inversion, HYPR-LR, Iter-DECT and HYPR-NLM, respectively. Difference images of both HYPR-LR and Iter-DECT show edge effect, while no significant edge effect is shown for HYPR-NLM, suggesting spatial resolution is well preserved for HYPR-NLM. Conclusion: HYPR-NLM provides an effective way to reduce the generic magnified image noise of dual–energy material decomposition while preserving resolution. This work is supported in part by NIH grants 7R01HL111141 and 1R01-EB016777. This work is also supported by the Natural Science Foundation of China (NSFC Grant No. 81201091), Fundamental Research Funds for the Central Universities in China, and Fund Project for Excellent Abroad Scholar Personnel in Science and Technology.

60 APPLIED LIFE SCIENCES↗

Selenization of CIS and CIGS layers deposited by chemical spray pyrolysis

Cu(In1-xGax)Se2 (CIGS) thin films with x=0 (CIS) and x=0.3 (CIGS) were prepared on Mo-coated glass substrate by using chemical spray pyrolysis at a substrate temperature of 350 degrees C, followed by selenization treatment at 550 degrees C in selenium environment under N2 gas flow. X-ray diffraction patterns of as-deposited CIGS layers on Mo showed polycrystalline chalcopyrite phase with an intense (112) plane. Splitting of (204)/(220) and (116)/(312) planes for the film with x=0.3 reveals deviation of tetragonal nature. Field emission scanning electron microscopy cross-sectional images of selenized films showed clear re-crystallization of grains. During the selenization process of the CIGS absorber, a thin interface layer of MoSe2 is formed. Line mapping of Mo/CIGS layer showed more gallium segregation at the interface of back contact resulting in band gap grading. Chemical composition and mapping of the as-deposited and selenized samples were determined by energy dispersive analysis of X-rays. This work leads to fabrication of low cost and large scale Mo/CIGS/CdS/ZnO/ZnO:Al device structure.

14 SOLAR ENERGY↗

Structure of Neutron-rich N = 126 Closed Shell Nuclei

A series of experiments devoted to the study of the neutron-rich N{approx}426 region have been performed at GSI, Darmstadt, within the Rare Isotopes Investigations at GSI (RISING) project. The highlights of the experimental results from these highly successful experiments include the first observation of excited states in three neutron-rich N = 126 closed shell nuclei: (i) In {sup 205}Au{sub 79} the conversion electron decay of the {pi}h{sub 11/2}{sup -1} seconds lived isomeric state into the {pi}d{sub 3/2}{sup -1} ground-state has been observed. In addition the yrast structure has been established up to spin-parity (19/2{sup +}) via the observation of the decay of an isomeric state with configuration {pi}(h{sub 11/2}{sup -1})10(s{sub 1/2}{sup -1});(ii) In {sup 204}Pt{sub 78}, the yrast sequence has been observed following the internal decay of I{sup {pi}} = (5{sup -}), (7{sup -}) and (10{sup +}) isomeric states; (iii) In {sup 203}Ir{sub 77} excited states have been observed following the decay of an isomeric state with structure 'similar' to that in its {sup 205}Au isotone. Shell model calculations have been performed in order to get a deeper understanding of the structure of these N = 126 nuclei. It was found that in order to get a good description for all available information on the N = 126 isotones below lead, both on excitation energies and transition strengths, small modifications of the standard two-body matrix elements were required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Failure mode and effects analysis based risk profile assessment for stereotactic radiosurgery programs at three cancer centers in Brazil

Purpose: The goal of this study was to evaluate the safety and quality management program for stereotactic radiosurgery (SRS) treatment processes at three radiotherapy centers in Brazil by using three industrial engineering tools (1) process mapping, (2) failure modes and effects analysis (FMEA), and (3) fault tree analysis. Methods: The recommendations of Task Group 100 of American Association of Physicists in Medicine were followed to apply the three tools described above to create a process tree for SRS procedure for each radiotherapy center and then FMEA was performed. Failure modes were identified for all process steps and values of risk priority number (RPN) were calculated from O, S, and D (RPN = O × S × D) values assigned by a professional team responsible for patient care. Results: The subprocess treatment planning was presented with the highest number of failure modes for all centers. The total number of failure modes were 135, 104, and 131 for centers I, II, and III, respectively. The highest RPN value for each center is as follows: center I (204), center II (372), and center III (370). Failure modes with RPN ≥ 100: center I (22), center II (115), and center III (110). Failure modes characterized by S ≥ 7, represented 68% of the failure modes for center III, 62% for center II, and 45% for center I. Failure modes with RPNs values ≥100 and S ≥ 7, D ≥ 5, and O ≥ 5 were considered as high priority in this study. Conclusions: The results of the present study show that the safety risk profiles for the same stereotactic radiotherapy process are different at three radiotherapy centers in Brazil. Although this is the same treatment process, this present study showed that the risk priority is different and it will lead to implementation of different safety interventions among the centers. Therefore, the current practice of applying universal device-centric QA is not adequate to address all possible failures in clinical processes at different radiotherapy centers. Integrated approaches to device-centric and process specific quality management program specific to each radiotherapy center are the key to a safe quality management program.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fracture Toughness Characterization of Generation II FeCrAl Alloys after ~18 dpa Irradiation

FeCrAl alloys are promising candidate materials for the accident tolerant fuel (ATF) cladding applications due to their excellent corrosion resistance to the elevated temperature steam environment. Currently, the handbook on FeCrAl material properties contains only limited data regarding the fracture toughness properties of any FeCrAl alloy. This includes alloys currently under investigation within the Advanced Fuels Campaign (AFC) at Oak Ridge National Laboratory (ORNL). In this project, a series of irradiation capsules have been irradiated in the High Flux Isotope Reactor (HFIR) at ORNL with two Generation II FeCrAl candidate alloys, i.e., C06M and C36M, to assess the fracture response of these alloys after neutron irradiation. These alloys represent the “book-end” compositions for C26M, the alloy currently being developed as the leading candidate for LWR cladding. A total of six irradiation capsules were irradiated in HFIR at target temperatures of 200°C, 330°C, and 500°C up to target damage doses of 8 displacements per atom (dpa) and 16 dpa. These damage doses represent the expected middle and end of life damage levels for typical LWR cladding while the irradiation temperature regimes will provide insight into the role of varying microstructural features on the fracture toughness properties of neutron irradiated FeCrAl alloys. To date, irradiation of all capsules has been completed in HFIR. This report summarizes the latest results of microhardness and fracture toughness PIE for the 16 dpa capsules (FCAB2, FCAB4, and FCAB6), for which the measured irradiation conditions were: 204°C/17.6dpa, 343°C/18.3dpa, and 507°C/18.6dpa. The main conclusions of this study can be summarized as follows: 1) After the 204°C/17.6dpa irradiation, both C06M and C36M exhibited significant irradiation hardening and embrittlement 2) After the 343°C/18.3dpa irradiation, both C06M and C36M exhibited small irradiation hardening without irradiation embrittlement 3) After the 507°C/18.6dpa irradiation, both C06M and C36M exhibited irradiation softening without irradiation embrittlement 4) Comparing the microhardness and Master Curve reference temperature T 0q before and after neutron irradiation, we did not observe a linear correlation between the two parameters for both C06M and C36M. This should be mainly due to a flat response of the Master Curve reference temperature T 0q to the irradiations at 166-204°C and 315-343°C ranges 5) C06M showed a lower T 0q , meaning better toughness, than C36M at the unirradiated condition and such trend was kept even after neutron irradiation except for the 166-204°C irradiation where both materials had similar T 0q . 6) In terms of hardening and embrittlement, the irradiation effect on both C06M and C36M appeared to saturate after an irradiation dose of 7 dpa.

36 MATERIALS SCIENCE↗

Cation Off-Stoichiometry Leads to High p-Type Conductivity and Enhanced Transparency in Co2ZnO4 and Co2NiO4 Thin Films

We explore the effects of cation off-stoichiometry on structural, electrical, optical, and electronic properties of Co{sub 2}ZnO{sub 4} normal spinel and Co{sub 2}NiO{sub 4} inverse spinel using theoretic and experimental (combinatorial and conventional) techniques, both at thermodynamic equilibrium and in the metastable regime. Theory predicts that nonequilibrium substitution of divalent Zn on nominally trivalent octahedral sites increases net hole density in Co{sub 2}ZnO{sub 4}. Experiment confirms high conductivity and high work function in Co{sub 2}NiO{sub 4} and Zn-rich Co{sub 2}ZnO{sub 4} thin films grown by nonequilibrium physical vapor deposition techniques. High p-type conductivities of Co{sub 2}ZnO{sub 4} (up to 5 S/cm) and Co{sub 2}NiO{sub 4} (up to 204 S/cm) are found over a broad compositional range, they are only weakly sensitive to oxygen partial pressure and quite tolerant to a wide range of processing temperatures. In addition, off-stoichiometry caused by nonequilibrium growth decreases the optical absorption of Co{sub 2}ZnO{sub 4} and Co{sub 2}NiO{sub 4} thin films, although the 500-nm thin films still have rather limited transparency. All these properties as well as high work functions make Co{sub 2}ZnO{sub 4} and Co{sub 2}NiO{sub 4} thin films attractive for technological applications, such as hole transport layers in organic photovoltaic devices or p-type buffer layers in inorganic solar cells.

14 SOLAR ENERGY↗

Measurements of ISGMR in Sn, Cd and Pb isotopes and the asymmetry of nuclear matter incompressibility

The compression-mode isoscalar giant monopole resonance (ISGMR) has been studied in the Sn, Cd and Pb isotopes using inelastic scattering of 400 MeV {alpha}-particles at extreme forward angles, including 0 deg. We have obtained completely 'background-free' inelastic-scattering spectra for the Sn, Cd, and Pb isotopes for a wide angular and excitation-energy range. The various giant resonances excited with different transferred angular momenta were extracted by a multipole-decomposition analysis (MDA). It was found that the centroid energies of the ISGMR in Sn isotopes are significantly lower than the theoretical predictions. The K{sub {tau}} in the empirical expression for the nuclear incompressibility has been determined to be K{sub {tau}} = -550{+-}100 MeV for the Sn isotopes. The extracted value for the Cd isotopes is K{sub {tau}} = -480{+-}100 MeV. These numbers are consistent with values of K{sub {tau}} = -370{+-}120 MeV obtained from an analysis of the isotopic transport ratios in medium-energy heavy-ion reactions, K{sub {tau}} -500{sub -100}{sup +120} MeV obtained from constraints placed by neutron-skin data from anti-protonic atoms across the mass table, and K{sub {tau}} = -500{+-}50 MeV obtained from theoretical calculations using different Skyrme interactions and relativistic mean field (RMF) Lagrangians. Stringent constraints on interactions employed in nuclear structure calculations are obtained on the basis of the experimentally determined values for K{sub {infinity}} and K{sub {tau}}. These parameters constrain as well the equation of state (EOS) of nuclear matter. However, a significant discrepancy still remains. The ISGMR positions in Sn and Cd isotopes are systematically lower than the predictions obtained on basis of determined from the ISGMR in {sup 208}Pb. This raises the question ''Why are Sn and Cd nuclei so soft?''. For a clue to solve the problem, we discuss the preliminary results on the exact positions of the ISGMR in {sup 204,206,208}Pb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crossing the Barriers: An Analysis of Permitting Barriers to Geothermal Development and Potential Improvement Scenarios

Developers have identified many non-technical barriers to geothermal power development, including permitting. Activities required for permitting, such as the associated environmental reviews, can take a considerable amount of time and delay project development. This paper discusses the impacts to geothermal development timelines due to the permitting challenges, including the regulatory framework, environmental review process, and ancillary permits. We identified barriers that have the potential to prevent geothermal development or delay timelines and defined improvement scenarios that could assist in expediting geothermal development and permitting timelines and lead to the deployment of additional geothermal resources by 2030 and 2050: (1) the creation of a centralized federal geothermal permitting office and utilization of state permit coordination offices as well as (2) an expansion of existing categorical exclusions applicable to geothermal development on Bureau of Land Management public lands to include the oil and gas categorical exclusions passed as part of the Energy Policy Act of 2005. We utilized the Regional Energy Deployment System (ReEDS) and the Geothermal Electricity Technology Evaluation Model (GETEM) to forecast baseline geothermal deployment based on previous analysis of geothermal project development and permitting timelines. The model results forecast that reductions in geothermal project timelines can have a significant impact on geothermal deployment. For example, using the ReEDS model, we estimated that reducing timelines by two years, perhaps due to the creation of a centralized federal geothermal permitting office and utilization of state permit coordination offices, could result in deployment of an additional 204 MW by 2030 and 768 MW by 2050 - a 13% improvement when compared to the business as usual scenario. The model results forecast that a timeline improvement of four years - for example with an expansion of existing categorical exclusions coupled with the creation of a centralized federal geothermal permitting office and utilization of state permit coordination offices - could result in deployment of an additional 2,529 MW of geothermal capacity by 2030 and 6,917 MW of geothermal capacity by 2050 - an improvement of 116% when compared to the business as usual scenario. These results suggest that reducing development timelines could be a large driver in the deployment of geothermal resources.

15 GEOTHERMAL ENERGY↗

WE-AB-204-09: Respiratory Motion Correction in 4D-PET by Simultaneous Motion Estimation and Image Reconstruction (SMEIR)

Purpose: In conventional 4D-PET, images from different frames are reconstructed individually and aligned by registration methods. Two issues with these approaches are: 1) Reconstruction algorithms do not make full use of all projections statistics; and 2) Image registration between noisy images can Result in poor alignment. In this study we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) method for cone beam CT for motion estimation/correction in 4D-PET. Methods: Modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM- TV) is used to obtain a primary motion-compensated PET (pmc-PET) from all projection data using Demons derived deformation vector fields (DVFs) as initial. Motion model update is done to obtain an optimal set of DVFs between the pmc-PET and other phases by matching the forward projection of the deformed pmc-PET and measured projections of other phases. Using updated DVFs, OSEM- TV image reconstruction is repeated and new DVFs are estimated based on updated images. 4D XCAT phantom with typical FDG biodistribution and a 10mm diameter tumor was used to evaluate the performance of the SMEIR algorithm. Results: Image quality of 4D-PET is greatly improved by the SMEIR algorithm. When all projections are used to reconstruct a 3D-PET, motion blurring artifacts are present, leading to a more than 5 times overestimation of the tumor size and 54% tumor to lung contrast ratio underestimation. This error reduced to 37% and 20% for post reconstruction registration methods and SMEIR respectively. Conclusion: SMEIR method can be used for motion estimation/correction in 4D-PET. The statistics is greatly improved since all projection data are combined together to update the image. The performance of the SMEIR algorithm for 4D-PET is sensitive to smoothness control parameters in the DVF estimation step.

60 APPLIED LIFE SCIENCES↗

Analysis of the HAE activity in the TJ-II stellarator using a Landau closure model

The aim of this study is to analyze the stability of helical Alfvén eigenmodes (HAEs) in TJ-II discharges and the stabilizing effect of the energetic particles generated by the neutral beam injector (NBI) on pressure gradient-driven modes (PGDMs). HAE and PGDM stability is studied using the linear version of the gyro-fluid code FAR3d and the continuous structure by the STELLGAP code. First, Alfvén eigenmode (AE) and PGDM activity observed in the experiments is reproduced by the simulations, identifying unstable m/n = 4/7 − 2/3 and 7/12 − 5/8 HAEs triggered around ρ = 0.66 showing a frequency of 209 and 204 kHz, respectively, as well as 5/3 PGDM. Next, a parametric study is performed with respect to the thermal ion density and iota profile in the middle-outer plasma region to verify the robustness of the simulation results with respect to the uncertainty of experimental profiles. The analysis confirms that experimental uncertainty does not cause large deviations in the simulation results, showing the destabilization of the same HAEs for all the configurations tested. The simulations also indicate the decay of the 5/3 PGDM growth rate as the energetic particle (EP) population in the plasma increases, consistent with the experiment. Stability analysis of the n = 3, 7, 11, n = 5, 9, 13, n = 6, 10, 14, and n = 8, 12 helical families is performed with respect to the NBI operational regime for different EP energies, β as well as deposition profiles. The most unstable configuration is the radially localized on-axis NBI operation (stiff EP density profile gradients nearby the magnetic axis). Using the simulation model that reproduces the observed Alfvén activity, we extend the study to analyze NBI performance within a theoretical framework. It shows that increasing NBI voltage (which raises EP energy) leads to a degradation in NBI performance for a given power (related to EP β and their density). To achieve better NBI operation, higher voltage must be balanced with lower injection power, ensuring stable AEs while keeping the same EP β.

Plasma confinement↗

WE-G-204-02: Utility of a Channelized Hotelling Model Observer Over a Large Range of Angiographic Exposure Levels

Purpose: Mathematical model observers provide a figure of merit that simultaneously considers a test object and the contrast, noise, and spatial resolution properties of an imaging system. The purpose of this work was to investigate the utility of a channelized Hotelling model observer (CHO) to assess system performance over a large range of angiographic exposure conditions. Methods: A 4 mm diameter disk shaped, iodine contrast test object was placed on a 20 cm thick Lucite phantom and 1204 image frames were acquired using fixed x-ray beam quality and for several detector target dose (DTD) values in the range 6 to 240 nGy. The CHO was implemented in the spatial domain utilizing 96 Gabor functions as channels. Detectability index (DI) estimates were calculated using the “resubstitution” and “holdout” methods to train the CHO. Also, DI values calculated using discrete subsets of the data were used to estimate a minimally biased DI as might be expected from an infinitely large dataset. The relationship between DI, independently measured CNR, and changes in results expected assuming a quantum limited detector were assessed over the DTD range. Results: CNR measurements demonstrated that the angiography system is not quantum limited due to relatively increasing contamination from electronic noise that reduces CNR for low DTD. Direct comparison of DI versus CNR indicates that the CHO relatively overestimates DI for low DTD and/or underestimates DI values for high DTD. The relative magnitude of the apparent bias error in the DI values was ∼20% over the 40x DTD range investigated. Conclusion: For the angiography system investigated, the CHO can provide a minimally biased figure of merit if implemented over a restricted exposure range. However, bias leads to overestimates of DI for low exposures. This work emphasizes the need to verify CHO model performance during real-world application.

60 APPLIED LIFE SCIENCES↗