Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAD 178”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 records · Page 2

Carbon Nanotube Supported Amorphous MoS 2 via Microwave Heating Synthesis for Enhanced Performance of Hydrogen Evolution Reaction

Amorphous molybdenum disulfide (MoS 2 ) is a promising electrochemical catalyst for hydrogen evolution reaction (HER) due to more active sites exposed on the surface compared to its crystalline counterpart. In this study, a novel fast three-minute one-pot method is proposed to prepare the single-wall carbon nanotube- (SWCNT-) supported amorphous MoS 2 via a microwave heating process. Compared to traditional hydro- or solvent thermal methods to prepare MoS 2 which usually consume more than 10 hours, it is more promising for fast production. An overpotential at 10 mA/cm 2 of amorphous MoS 2 @SWCNT is 178 mV, which is 99 mV and 22 mV lower than crystalline MoS 2 @SWCNT and pure amorphous MoS 2 , respectively. After running 1000 cycles of polarization, ~2% increase in overpotential is observed, indicating its good stability. The enhanced performance results from the beneficial combination of the SWCNT substrate and the amorphous microstructures. The introduction of SWCNT increases catalyst conductivity and prevents MoS 2 aggregation. The amorphous microstructures of MoS 2 prepared by a microwave heating method lead to more Mo edges or active sites exposed.

Tang, Wei↗

Structurally colored protease responsive nanoparticle hydrogels with degradation-directed assembly

A tunable protease responsive nanoparticle hydrogel (PRNH) that demonstrates large non-iridescent color changes due to a degradation-directed assembly of nanoparticles is reported. Structurally colored composites are fabricated with silica particles, 4-arm poly(ethylene glycol) norbornene (4PEGN), and a proteolytically degradable peptide. When placed in a protease solution, the peptide crosslinks degrade causing electrostatic binding and adsorption of the polymer to the particle surface which leads to the assembly of particles into compact amorphous arrays with structural color. The particle surface charge and size is investigated to probe their effect on the assembly mechanism. Interestingly, only PRNHs with highly negative particle surface charge exhibit color changes after degradation. Ultra-small angle X-ray scattering revealed that the particles become coated in polymer after degradation, producing a material with less order compared to the initial state. Altering the particle diameter modulates the composites’ color, and all sizes investigated (178–297 nm) undergo the degradation-directed assembly. Varying the amount of 4PEGN adjusts the swollen PRNH color and has no effect on the degradation-directed assembly. Finally, taken together, the effects of surface charge, particle size, and polymer concentration allow for the formulation of new design rules for fabricating tunable PRNHs that display vivid changes in structural color upon degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Blade Roughness on Transition and Wind Turbine Performance.

The real-world effect of accumulated surface roughness on wind-turbine power production is not well understood. To isolate specific blade roughness features and test their effect, field measurements of turbine-blade roughness were made and simulated on a NACA 633-418 airfoil in a wind tunnel. Insect roughness, paint chips, and erosion were characterized then manufactured. In the tests, these roughness configurations were recreated as distributed roughness, a forward-facing step, and an eroded leading edge. Distributed roughness was tested in three heights and five densities. Chord Reynolds number was varied between 0:8 to 4:8 × 10 6 . Measurements included lift, drag, pitching moment, and boundary-layer transition location. Results indicate minimal effect from paint-chip roughness. As distributed roughness height and density increase, the lift-curve slope, maximum lift, and lift-to-drag ratio decrease. As Reynolds number increases, natural transition is replaced by bypass transition. The critical roughness Reynolds number varies between 178 to 318, within the historical range. At a chord Reynolds number of 3:2 × 10 6 , the maximum lift-to-drag ratio decreases 40% for 140 μm roughness, corresponding to a 2.3% loss in annual energy production. Simulated performance loss compares well to measured performance loss of an in-service wind turbine.

17 WIND ENERGY↗

SU-G-IeP3-13: Real-Time Patient and Staff Dose Monitoring in Fluoroscopy Guided Interventions

Purpose: Interventional radiology procedures involve the use of X-rays, which can pose a large radiation burden on both patients and staff. Although some reports on radiation dose are available, most studies focus on limited types of procedures and only report patient dose. In our cathlabs a dedicated real-time patient and staff monitoring system was installed in November 2015. The aim of this study was to investigate the patient and staff dose exposure for different types of interventions. Methods: Radiologists involved in fluoroscopy guided interventional radiology procedures wore personal dose meters (PDM, DoseAware, Philips) on their lead-apron that measured the personal dose equivalent Hp(10), a measure for the effective dose (E). Furthermore, reference PDMs were installed in the C-arms of the fluoroscopy system (Allura XPer, Philips). Patient dose-area-product (DAP) and PDM doses were retrieved from the monitoring system (DoseWise, Philips) for each procedure. A total of 399 procedures performed between November 2015 and February 2016 were analyzed with respect to the type of intervention. Interventions were grouped by anatomy and radiologist position. Results: The mean DAP for the different types of interventions ranged from 2.86±2.96 Gycm{sup 2} (percutaneous gastrostomy) to 147±178 Gycm{sup 2} (aortic repair procedures). The radiologist dose (E) ranged from 5.39±7.38 µSv (cerebral interventions) to 84.7±106 µSv (abdominal interventions) and strongly correlated with DAP (R{sup 2}=0.83). The E normalized to DAP showed that the relative radiologist dose was higher for interventions in larger body parts (e.g. abdomen) compared to smaller body parts (e.g. head). Conclusion: Using a real-time dose monitoring system we were able to assess the staff and patient dose revealing that the relative staff dose strongly depended on the type of procedure and patient anatomy. This could be explained by the position of the radiologist with respect to the patient and X-ray tube. To facilitate this study L Vergoossen received a scholarship from Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

New measurements of low-energy resonances in the Ne 22 ( p , γ ) Na 23 reaction

The Ne 22 ( p , γ ) Na 23 reaction is one of the most uncertain reactions in the NeNa cycle and plays a crucial role in the creation of Na 23 , the only stable Na isotope. Uncertainties in the low-energy rates of this and other reactions in the NeNa cycle lead to ambiguities in the nucleosynthesis predicted from models of thermally pulsing asymptotic giant branch (AGB) stars. This in turn complicates the interpretation of anomalous Na-O trends in globular cluster evolutionary scenarios. Prior studies of the Ne 22 ( p , γ ) Na 23 , Ne 22 ( He 3 , d ) Na 23 , and C 12 ( C 12 , p ) Na 23 reactions disagree on the strengths, spins, and parities of low-energy resonances in Na 23 and the direct-capture Ne 22 ( p , γ ) Na 23 reaction rate contains large uncertainties as well. Here, we present new measurements of resonances at E r c.m. = 417 , 178, and 151 keV and of the direct-capture process in the Ne 22 ( p , γ ) Na 23 reaction. The resulting total Ne 22 ( p , γ ) Na 23 rate is approximately a factor of 20 higher than the rate listed in a recent compilation at temperatures relevant to hot-bottom burning in AGB stars. Although our rate is close to that derived from a recent Ne 22 ( p , γ ) Na 23 measurement by Cavanna et al. in 2015, we find that this large rate increase results in only a modest 18% increase in the Na 23 abundance predicted from a 5 M ⊙ thermally pulsing AGB star model from Ventura and D'Antona (2005). The estimated astrophysical impact of this rate increase is in marked contrast to the factor of ~ 3 increase in Na 23 abundance predicted by Cavanna et al. and is attributed to the interplay between the Na 23 ( p , α ) Ne 20 and Ne 20 ( p , γ ) Na 21 reactions, both of which remain fairly uncertain at the relevant temperature range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Regulating Cation Interactions for Zero–Strain and High–Voltage P2–type Na 2/3 Li 1/6 Co 1/6 Mn 2/3 O 2 Layered Oxide Cathodes of Sodium–Ion Batteries

Deep sodium extraction/insertion of sodium cathodes usually causes undesired Jahn–Teller distortion and phase transition, both of which will reduce structural stability and lead to poor long-cycle reliability. Here we report a zero-strain P2- Na 2/3 Li1/6Co 1/6 Mn 2/3 O 2 cathode, in which the lithium/cobalt substitution contributes to reinforcing the host structure by reducing the Mn 3+ /Mn 4+ redox, mitigating the Jahn–Teller distortion, and minimizing the lattice change. 94.5 % of Na + in the unit structure can be reversibly cycled with a charge cut-off voltage of 4.5 V (vs. Na + /Na). Impressively, a solid-solution reaction without phase transitions is realized upon deep sodium (de)intercalation, which poses a minimal volume deviation of 0.53 %. Finally, it attains a high discharge capacity of 178 mAh g –1 , a high energy density of 534 Wh kg –1 , and excellent capacity retention of 95.8 % at 1 C after 250 cycles.

25 ENERGY STORAGE↗

SU-F-T-178: Optimized Design of a Diamond Detector Specifically Dedicated to the Dose Distribution Measurements in Clinical Proton Pencil Beams

Purpose: In proton-therapy, pencil beam scanning (PBS) dosimetry presents a real challenge due to the small size of the beam (about 3 to 8 mm in FWHM), the pulsed high dose rate (up to 100 Gy/s) and the proton energy variation (about 30 MeV to 250 MeV). In the framework of French INSERM DEDIPRO project, a specifically dedicated single crystal diamond dosimeter (SCDDo) was developed with the objective of obtaining accurate measurements of the dose distribution in PBS modality. Methods: Monte Carlo simulations with MCNPX were performed. A small proton beam of 5 mm in FWHM was simulated as well as diamond devices with various size, thickness and holder composition. The calculated doses-to-diamond were compared with the doses-to-water in order to reduce the perturbation effects. Monte-Carlo simulations lead to an optimized SCDDo design for small proton beams dosimetry. Following the optimized design, SCDDos were mounted in water-equivalent holders with electrical connection adapted to standard electrometer. First, SCDDos performances (stability, repeatability, signal-to-background ratio…) were evaluated with conventional photon beams. Then, characterizations (dose linearity, dose rate dependence…) with wide proton beams were performed at proton-therapy center (IC-CPO) from Curie Institute (France) with the passive proton delivery technique, in order to confirm dosimetric requirements. Finally, depth-dose distributions were measured in a water tank, for native and modulated Bragg Peaks with the collimator of 12 cm, and compared to a commercial PPC05 parallel-plate ionization chamber reference detector. Lateral-dose profiles were also measured with the collimator of 5 mm, and compared to a commercial SFD diode. Results: The results show that SCDDo design does not disturb the dose distributions. Conclusion: The experimental dose distributions with the SCDDo are in good agreement with the commercial detectors and no energy dependence was observed with this device configuration.

07 ISOTOPE AND RADIATION SOURCES↗

Tensile strains give rise to strong size effects for thermal conductivities of silicene, germanene and stanene

Based on first principles calculations and self-consistent solution of linearized Boltzmann-Peierls equation for phonon transport approach within a three-phonon scattering framework, we characterize lattice thermal conductivities k of freestanding silicene, germanene and stanene under different isotropic tensile strains and temperatures. In this work, we find a strong size dependence of k for silicene with tensile strain, i.e., divergent k with increasing system size, in contrast, the intrinsic room temperature k for unstrained silicene converges with system size to 19.34 W/m –1 K –1 by 178 nm. The room temperature k of strained silicene becomes as large as that of bulk silicon by 84 m, indicating the possibility of using strain in silicene to manipulate k for thermal management. The relative contribution to the intrinsic k from out-of-plane acoustic modes is largest for unstrained silicene, –39% at room temperature. The single mode relaxation time approximation, which works reasonably well for bulk silicon, fails to appropriately describe phonon thermal transport in silicene, germanene and stanene within the temperature range considered. For large samples of silicene, k increases with tensile strain, peaks at –7% strain and then decreases with further strain. In germanene and stanene increasing strain hardens and stabilizes long wavelength out-of-plane acoustic phonons, and leads to similar k behaviors to those of silicene. As a result, these findings further our understanding of phonon dynamics in group-IV buckled monolayers and may guide transfer and fabrication techniques of these freestanding samples and engineering k by size and strain for applications of thermal management and thermoelectricity.

36 MATERIALS SCIENCE↗

Radiation Exposure in Transjugular Intrahepatic Portosystemic Shunt Creation

PurposeTransjugular intrahepatic portosystemic shunt (TIPS) creation is considered as being one of the most complex procedures in abdominal interventional radiology. Our aim was twofold: quantification of TIPS-related patient radiation exposure in our center and identification of factors leading to reduced radiation exposure.Materials and methodsThree hundred and forty seven consecutive patients underwent TIPS in our center between 2007 and 2014. Three main procedure categories were identified: Group I (n = 88)—fluoroscopic-guided portal vein targeting, procedure done in an image intensifier-based angiographic system (IIDS); Group II (n = 48)—ultrasound-guided portal vein puncture, procedure done in an IIDS; and Group III (n = 211)—ultrasound-guided portal vein puncture, procedure done in a flat panel detector-based system (FPDS). Radiation exposure (dose-area product [DAP], in Gy cm{sup 2} and fluoroscopy time [FT] in minutes) was retrospectively analyzed.ResultsDAP was significantly higher in Group I (mean ± SD 360 ± 298; median 287; 75th percentile 389 Gy cm{sup 2}) as compared to Group II (217 ± 130; 178; 276 Gy cm{sup 2}; p = 0.002) and Group III (129 ± 117; 70; 150 Gy cm{sup 2}p < 0.001). The difference in DAP between Groups II and III was also significant (p < 0.001). Group I had significantly longer FT (25.78 ± 13.52 min) as compared to Group II (20.45 ± 10.87 min; p = 0.02) and Group III (19.76 ± 13.34; p < 0.001). FT was not significantly different between Groups II and III (p = 0.73).ConclusionsReal-time ultrasound-guided targeting of the portal venous system during TIPS creation results in a significantly lower radiation exposure and reduced FT. Further reduction in radiation exposure can be achieved through the use of modern angiographic units with FPDS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CdS/PbSe heterojunction for high temperature mid-infrared photovoltaic detector applications

n-CdS/p-PbSe heterojunction is investigated. A thin CdS film is deposited by chemical bath deposition on top of epitaxial PbSe film by molecular beam epitaxy on Silicon. Current-voltage measurements demonstrate very good junction characteristics with rectifying ratio of ∼178 and ideality factor of 1.79 at 300 K. Detectors made with such structure exhibit mid-infrared spectral photoresponse at room temperature. The peak responsivity R{sub λ} and specific detectivity D{sup *} are 0.055 A/W and 5.482 × 10{sup 8} cm·Hz{sup 1/2}/W at λ = 4.7 μm under zero-bias photovoltaic mode. Temperature-dependent photoresponse measurements show abnormal intensity variation below ∼200 K. Possible reasons for this phenomenon are also discussed.

36 MATERIALS SCIENCE↗

Yield stress and flow behavior of enzyme liquefied slurries from corn cobs and corn stover pellets

With the increase in population, the world will depend on renewable sources to meet the increasing energy needs. The use of lignocellulosic biomass as a renewable source has been proven efficient for conversion to cellulosic ethanol and capable of contributing to thresholds for energy demand while reducing greenhouse gases by 90% when compared with fossil fuels. However, limitations in feeding and flow within biorefineries is encountered when system plugging occurs due to biomass compaction and a high yield stress for slurries formed during its processing, thereby preventing transport of biomass materials between plant unit operations. In some cases, this leads to unexpected plant shutdowns increasing industrial operational costs. As an alternative, enzyme-assisted liquefaction for slurry creation from corn stover at solids loadings up to 30% is reported in this work. Two different kinds of biomass (pelleted corn stover and cobs) were liquefied in a fed-batch process using commercial enzymes Celluclast 1.5L or Ctec-2 at 1FPU or 3 FPU per gram of dry solids in 10 mM sodium citrate buffer solution (pH 4.8). Pellets were fed into a 1 L stirred bioreactor according to a pre-defined fed-batch protocol over the first 5 hours until reaching 30% of solids loading. After 6, 24 and 96 hours, samples were taken and characterized with respect to their sugar composition, rheology and water absorption. Successful slurry creation with dramatically reduced yield stress was achieved for corn stover for both assessed enzymes. Yield stresses of 178±7 Pa (3 FPU, Celluclast 1.5L) and 79±6 Pa (3 FPU, Ctec-2) were measured for corn stover at 24 hours, compared to 6,000 Pa for samples without enzyme. Yield stress was 155± 29 Pa (3FPU, Ctec-2) and 257 ± 72 Pa (1 FPU,Celluclast 1.5L) for corn cobs at 24 hours. Yield stress decreased when residence time increased with an enhanced fluidity noted for higher enzyme concentrations. A profile for 6, 24 and 96h of yield stress measurements is presented.

Guitierrez, Diana↗