Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sarnoff JND Vision Model for Flat-Panel Design

This document describes adaptation of the basic Sarnoff JND Vision Model created in response to the NASA/ARPA need for a general-purpose model to predict the perceived image quality attained by flat-panel displays. The JND model predicts the perceptual ratings that humans will assign to a degraded color-image sequence relative to its nondegraded counterpart. Substantial flexibility is incorporated into this version of the model so it may be used to model displays at the sub-pixel and sub-frame level. To model a display (e.g., an LCD), the input-image data can be sampled at many times the pixel resolution and at many times the digital frame rate. The first stage of the model downsamples each sequence in time and in space to physiologically reasonable rates, but with minimum interpolative artifacts and aliasing. Luma and chroma parts of the model generate (through multi-resolution pyramid representation) a map of differences-between test and reference called the JND map, from which a summary rating predictor is derived. The latest model extensions have done well in calibration against psychophysical data and against image-rating data given a CRT-based front-end. THe software was delivered to NASA Ames and is being integrated with LCD display models at that facility,

Brill, Michael H.↗

Using the Human Eye to Characterize Displays

Monitor characterization has taken on new importance for non-professional users, who are not usually equipped to make photometric measurements. We studied adjusting brightness to set the black level, banding effects due to digitization, and gamma estimation in the light and in the dark, and a color-matching task in the light, on a desktop CRT (Cathode-Ray Tube) and a laptop LCD (Liquid Crystal Display). Observers demonstrated the sensitivity of the visual system for comparative judgments in black-level adjustment, banding visibility, and gamma estimation. The results of the color-matching task were ambiguous. In the brightness adjustment task, the action of the adjustment was not as presumed; however, perceptual judgments were as expected under the actual conditions. When the gamma estimates of observers were compared to photometric measurements, problems with the definition of gamma were identified. Information about absolute light levels that would be important for characterizing a displays, given the shortcomings of gamma in measuring apparent contrast, are not measurable by eye alone. The LCD was not studied as extensively as the CRT because of viewing-angle problems, and its transfer function did not follow a power law, rendering gamma estimation meaningless.

Gille, Jennifer↗

The New Realm of 3-D Vision

Dimension Technologies Inc., developed a line of 2-D/3-D Liquid Crystal Display (LCD) screens, including a 15-inch model priced at consumer levels. DTI's family of flat panel LCD displays, called the Virtual Window(TM), provide real-time 3-D images without the use of glasses, head trackers, helmets, or other viewing aids. Most of the company initial 3-D display research was funded through NASA's Small Business Innovation Research (SBIR) program. The images on DTI's displays appear to leap off the screen and hang in space. The display accepts input from computers or stereo video sources, and can be switched from 3-D to full-resolution 2-D viewing with the push of a button. The Virtual Window displays have applications in data visualization, medicine, architecture, business, real estate, entertainment, and other research, design, military, and consumer applications. Displays are currently used for computer games, protein analysis, and surgical imaging. The technology greatly benefits the medical field, as surgical simulators are helping to increase the skills of surgical residents. Virtual Window(TM) is a trademark of Dimension Technologies Inc.

Source record↗

Using the Human Eye to Characterize Displays

Monitor characterization has taken on new importance for non-professional users, who are not usually equipped to make photometric measurements. Our purpose was to examine some of the visual judgments used in characterization schemes that have been proposed for web users. We studied adjusting brightness to set the black level, banding effects due to digitization, and gamma estimation in the light and in the dark, and a color-matching task in the light, on a desktop CRT and a laptop LCD. Observers demonstrated the sensitivity of the visual system for comparative judgments in black-level adjustment, banding visibility, and gamma estimation. The results of the color-matching task were ambiguous. In the brightness adjustment task, the action of the adjustment was not as presumed; however, perceptual judgments were as expected under the actual conditions. When the gamma estimates of observers were compared to photometric measurements, problems with the definition of gamma were identified. Information about absolute light levels that would be important for characterizing a display, given the shortcomings of gamma in measuring apparent contrast, are not measurable by eye alone. The LCD was not studied as extensively as the CRT because of viewing-angle problems, and its transfer function did not follow a power law, rendering gamma estimation meaningless.

Gille, Jennifer↗

New approaches to virtual environment surgery

This research focused on two main problems: 1) low cost, high fidelity stereoscopic imaging of complex tissues and organs; and 2) virtual cutting of tissue. A further objective was to develop these images and virtual tissue cutting methods for use in a telemedicine project that would connect remote sites using the Next Generation Internet. For goal one we used a CT scan of a human heart, a desktop PC with an OpenGL graphics accelerator card, and LCD stereoscopic glasses. Use of multiresolution meshes ranging from approximately 1,000,000 to 20,000 polygons speeded interactive rendering rates enormously while retaining general topography of the dataset. For goal two, we used a CT scan of an infant skull with premature closure of the right coronal suture, a Silicon Graphics Onyx workstation, a Fakespace Immersive WorkBench and CrystalEyes LCD glasses. The high fidelity mesh of the skull was reduced from one million to 50,000 polygons. The cut path was automatically calculated as the shortest distance along the mesh between a small number of hand selected vertices. The region outlined by the cut path was then separated from the skull and translated/rotated to assume a new position. The results indicate that widespread high fidelity imaging in virtual environment is possible using ordinary PC capabilities if appropriate mesh reduction methods are employed. The software cutting tool is applicable to heart and other organs for surgery planning, for training surgeons in a virtual environment, and for telemedicine purposes.

NASA Discipline Neuroscience↗

A Countermeasure for Space Motion Sickness

Overall, the results obtained in both the U.S. and the Russian space programs indicate that most space crews will experience some symptoms of motion sickness (MS) causing significant impact on the operational objectives that must be accomplished to assure mission success. At this time the primary countermeasure for MS requires the administration of Promethazine. Promethazine is not a benign drug, and is most frequently administered just prior to the sleep cycle to prevent its side effects from further compromising mission objectives. Clearly other countermeasures for SMS must be developed. Currently the primary focus is on two different technologies: (1) developing new and different pharmacological compounds with less significant side effects, (2) preflight training. The primary problem with all of these methods for controlling MS is time. New drugs that may be beneficial are years from testing and development, and preflight training requires a significant investment of crew time during an already intensive pre-launch schedule. Granted, motion sickness symptoms can be minimized with either of the two methods detailed above, however, it may be possible to develop a countermeasure that does not require either extensive adaptation time or exposure to motion sickness. Approximately 25 years ago Professor Geoffrey Melvill Jones presented his work on adaptation of the vestibuloocular reflex (VOR) using optically reversed vision (left-right prisms) during head rotations in the horizontal plane. It was of no surprise that most subjects experienced motion sickness while wearing the optically reversing prisms. However, a serendipitous finding emerged during this research showing that the same subjects did not experience motion sickness symptoms when wearing the reversing prisms under stroboscopic illumination. The mechanism, by which this side-effect was believed to have occurred, is not clearly understood. However, the fact that no motion sickness was ever noted, suggests the possibility of producing functionally useful adaptation during space flight without the penalty of disabling motion sickness by controlling the rate of the adaptive process by means of an appropriate stroboscopically presented environment. After several recent meetings with Professor Melvill Jones, we were encouraged to repeat the motion sickness portions of his and Mandl's 1981 stroboscopic experiment. In conducting this experiment we used a randomized cross-over design where subjects were randomly assigned to either a stroboscopic flash or no strobe for their first exposure in the experimental design. Twenty subjects (19 subjects completed the study) read a short passage from Treasure Island mounted on the wall approximately 1 m from their eyes while wearing left-right reversing prisms. The strobe on time of 3 microseconds and flash frequency of 4 Hz was set to equal that used in the original study. Motion sickness was scored using a modified Miller and Graybiel scale that we constructed to include symptoms that may be elicited under conditions where reversing prisms are worn. On this scale a score of 5 represented Malaise IIa (mild motion sickness) and a score of 8 or above is approaching frank sickness. Symptoms were tracked and recorded every 5 min during the task. Testing was limited to 30 min unless the subject had reached the MIIa score, at which time the test was terminated. Performance under stroboscopic illumination was significantly better than when the subjects read under normal room illumination while wearing the left-right reversing prisms. Based on these results we developed a goggle system using LCD material that can be strobed. To evaluate the effectiveness of stroboscopic goggles we tested an additional 9 subjects in addition to retesting 10 used in the stroboscopic pilot study described above. These 19 subjects wore a pair of strobing LCD goggles that could be cycled at 4 Hz. These subjects wore the goggles while also wearing left-right reversg prisms. Results while wearing the goggles showed that none of the 19 subjects scored at the MIIa level on the motion sickness rating scale. When the goggles did not flash (no strobe), 11 of the 19 developed symptoms above the MIIa criteria. As a countermeasure the goggles seem to be effective, even with an on time of 10 msec (time the goggles are clear). We have also collected anecdotal data, from our personnel in the Neuroscience Laboratory at the Johnson Space Center, suggesting that the goggles may effective in preventing carsickness.

Reschke, M. F.↗

Stroboscopic Vision as a Treatment Motion Sickness

Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill-Jones, we have evaluated stroboscopic vision as a method of preventing motion sickness. Methods: Nineteen subjects read text while making +/-20deg head movements in the horizontal plane at 0.2 Hz while wearing left-right reversing prisms during exposure to 4 Hz stroboscopic or normal room illumination. Testing was repeated using LCD shutter glasses as the stroboscopic source with an additional 19 subjects. Results: With Strobe, motion sickness was significantly lower than with normal room illumination. Results with the LCD shutter glasses were analogous to those observed with environmental strobe. Conclusions: Stroboscopic illumination appears to be effective where retinal slip is a factor in eliciting motion sickness. Additional research is evaluating the glasses efficacy for, carsickness, sickness in parabolic flight and seasickness. There is evidence from pilot studies showing that the glasses reduce saccade velocity to visually presented targets by approximately half of the normal values. It is interesting to note that adaptation to space flight may also slow saccade velocity.

Reschke, Millard F.↗

Stroboscope Controller for Imaging Helicopter Rotors

A versatile electronic timing-and-control unit, denoted a rotorcraft strobe controller, has been developed for use in controlling stroboscopes, lasers, video cameras, and other instruments for capturing still images of rotating machine parts especially helicopter rotors. This unit is designed to be compatible with a variety of sources of input shaftangle or timing signals and to be capable of generating a variety of output signals suitable for triggering instruments characterized by different input-signal specifications. It is also designed to be flexible and reconfigurable in that it can be modified and updated through changes in its control software, without need to change its hardware. Figure 1 is a block diagram of the rotorcraft strobe controller. The control processor is a high-density complementary metal oxide semiconductor, singlechip 8-bit microcontroller. It is connected to a 32K x 8 nonvolatile static random-access memory (RAM) module. Also connected to the control processor is a 32K 8 electrically programmable read-only-memory (EPROM) module, which is used to store the control software. Digital logic support circuitry is implemented in a field-programmable gate array (FPGA). A 240 x 128-dot, 40- character 16-line liquid-crystal display (LCD) module serves as a graphical user interface; the user provides input through a 16-key keypad mounted next to the LCD. A 12-bit digital-to-analog converter (DAC) generates a 0-to-10-V ramp output signal used as part of a rotor-blade monitoring system, while the control processor generates all the appropriate strobing signals. Optocouplers are used to isolate all input and output digital signals, and optoisolators are used to isolate all analog signals. The unit is designed to fit inside a 19-in. (.48-cm) rack-mount enclosure. Electronic components are mounted on a custom printed-circuit board (see Figure 2). Two power-conversion modules on the printedcircuit board convert AC power to +5 VDC and 15 VDC, respectively.

Jensen, Scott↗

Comparing perceptions of a dimmable LED lighting system between a real space and a virtual reality display

Over the last several decades, designers have used digital screens to view images of real and simulated spaces and make critical design decisions. Screen technology has improved during this time, as technologies like OLED have replaced legacy displays (CRT, plasma, and LCD). These new screens provide a higher pixel resolution, luminous output and contrast ratio. Immersive head-mounted displays now allow designers to view immersive images, and recent developments in real-time rendering have encouraged the uptake of virtual reality (VR) head-mounted displays in mainstream practice and design education. This paper presents an experiment on lighting perception using a series of LED lighting conditions in a real space and a virtual representation of those conditions captured using a 360° high-dynamic-range camera and presented on an HTC Vive Pro HMD. Fifty-three participants were asked to rate each lighting condition by viewing it in a real space (n = 30) or via immersive HDR photographs displayed in a VR HMD (n = 23). The results show that ratings of visual comfort, pleasantness, evenness, contrast and glare are similar between the HTC Vive Pro HMD and our real space when evaluating well-lit scenes, but significant differences emerge in dim and highly contrasted scenes for a number of rating scales.

Rockcastle, S.↗

Modeling the Effect of Film Morphology on the Performance of an OLED Device

Organic Light Emitting Diode (OLED) technology is replacing the liquid crystal displays (LCD) in cell phones and is also expected to impact television displays in the future. Dow has an active OLED research program. To complement and ultimately drive this effort, it is necessary to develop efficient computational screening tools for selection and optimization of target molecules. To this end we sought to identify and expand on existing models used by Dow that can better predict the mobility of electrons and holes in organic materials. We focused on N,N'- bis(1-naphthyl)-N,N'-diphenyl-1,1'-biphenyl-4,4'-diamine (NPD), frequently used in academic studies of organic light-emitting diodes; we also studied 4,4'-Bis(N-carbazolyl)-1,1'-biphenyl (CBP), tris(4-carbazoyl-9-ylphenyl)amine (TCTA), and bathophenanthroline (BPhen). We developed a workflow, using a combination of molecular dynamics and quantum chemistry calculations, to predict trends in the electronic structure that correlate with measured electron and hole mobilities of small molecule materials such as NPD for OLEDs, comparing with measurements in the literature and at Dow. This work comprised a first step toward predictive charge carrier mobilities in small-molecule electronic materials with complex morphologies.

47 OTHER INSTRUMENTATION↗

Cradle-to-Grave Lifecycle Analysis of U.S. Light-Duty Vehicle-Fuel Pathways: A Greenhouse Gas Emissions and Economic Assessment of Current (2020) and Future (2030-2035) Technologies

This study provides a comprehensive life cycle analysis (LCA), or cradle-to-grave (C2G) analysis, of the cost and greenhouse gas (GHG) emissions of a variety of vehicle-fuel pathways, the levelized cost of driving (LCD) and cost of avoided GHG emissions. The C2G analysis assesses light duty midsize sedans and small sport utility vehicles (SUVs) across a variety of vehicle-fuel technology pathways, including conventional internal combustion engine vehicles (ICEVs), flexible hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), battery electric vehicles (BEVs) with varying vehicle ranges, and fuel cell electric vehicles (FCEVs). Coming at a timely manner, given the marked increase, since 2016, in climate aspirations announced by governmental institutions and private firms both in the US and across the globe, this analysis builds on a previous comprehensive life cycle analysis, updating that study’s 2016 assumptions and methods (Elgowainy et al. 2016). These updates incorporate technological advances and changes in energy supply sources that have emerged during the intervening period. Utilizing these updated assumptions and methods, alongside more recent data, the present report accounts for a broader range of vehicle technologies and considers both current (2020) and expected future (2030-2035) conditions. Reflecting increased research interest in synthetic liquid fuels produced using renewable low-carbon electricity and CO 2 sources, electro-fuels (a.k.a. e-fuels) were added to the potential future fuel technologies that are evaluated. This study takes a “pathway” approach rather than a “scenario” approach; hence distinct, technically feasible, routes or sequences of processes starting with one or more feedstocks and ending with an intermediate or a final product are examined, not necessarily constrained by practical feedstock, economic, policy, and market considerations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cradle-to-Grave Lifecycle Analysis of U.S. Light-Duty Vehicle-Fuel Pathways: A Greenhouse Gas Emissions and Economic Assessment of Current (2020) and Future (2030-2035) Technologies

This study provides a comprehensive life cycle analysis (LCA), or cradle-to-grave (C2G) analysis, of the cost and greenhouse gas (GHG) emissions of a variety of vehicle-fuel pathways, the levelized cost of driving (LCD) and cost of avoided GHG emissions. The C2G analysis assesses light duty midsize sedans and small sport utility vehicles (SUVs) across a variety of vehicle-fuel technology pathways, including conventional internal combustion engine vehicles (ICEVs), flexible hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), battery electric vehicles (BEVs) with varying vehicle ranges, and fuel cell electric vehicles (FCEVs). In evaluating the vehicle-fuel combinations, this study considers both low-volume and high-volume “CURRENT TECHNOLOGY” cases (nominally 2020) and a high-volume “FUTURE TECHNOLOGY” lower-carbon case (nominally 2030–2035).

33 ADVANCED PROPULSION SYSTEMS↗

Record of Decision: MEBT Energy Change

The LAMP Conceptual Design (LCD), as described in the LAMP Conceptual Design Report incorporates a radiofrequency quadrupole (RFQ) with an output beam energy of 3.0-MeV; the medium energy beam transport line (MEBT) transports beam from the end of the RFQ into the first LAMP drift tube linac (DTL) tank. The MEBT contains components, such as rebunchers and beam choppers, designed for the specific output energy of the RFQ, and the DTL tank is designed to accept this beam energy.

43 PARTICLE ACCELERATORS↗

Record of Decision: LEBT Energy Change

The LAMP Conceptual Design (LCD), as described in the LAMP Conceptual Design Report incorporates multiple 100-keV low-energy beam transport (LEBT) lines between the ion sources and the radiofrequency quadrupole (RFQ). The LEBT lines transport H + and H - beams from their respective ion sources to the RFQ entrance, and provide the required manipulations (focusing, steering, chopping, etc.) to the ion beams to prepare them for injection into the RFQ and further acceleration.

43 PARTICLE ACCELERATORS↗

Polymer Nanocomposite Sensors with Improved Piezoelectric Properties through Additive Manufacturing

Additive manufacturing (AM) technology has recently seen increased utilization due to its versatility in using functional materials, offering a new pathway for next-generation conformal electronics in the smart sensor field. However, the limited availability of polymer-based ultraviolet (UV)-curable materials with enhanced piezoelectric properties necessitates the development of a tailorable process suitable for 3D printing. This paper investigates the structural, thermal, rheological, mechanical, and piezoelectric properties of a newly developed sensor resin material. The polymer resin is based on polyvinylidene fluoride (PVDF) as a matrix, mixed with constituents enabling UV curability, and boron nitride nanotubes (BNNTs) are added to form a nanocomposite resin. The results demonstrate the successful micro-scale printability of the developed polymer and nanocomposite resins using a liquid crystal display (LCD)-based 3D printer. Additionally, incorporating BNNTs into the polymer matrix enhanced the piezoelectric properties, with an increase in the voltage response by up to 50.13%. This work provides new insights for the development of 3D printable flexible sensor devices and energy harvesting systems.

42 ENGINEERING↗

Hybridization of biomedical circuitry

The design and fabrication of low power hybrid circuits to perform vital signs monitoring are reported. The circuits consist of: (1) clock; (2) ECG amplifier and cardiotachometer signal conditioner; (3) impedance pneumobraph and respiration rate processor; (4) hear/breath rate processor; (5) temperature monitor; and (6) LCD display.

Rinard, G. A.↗

An integrated control panel utilizing a programmable varistor-multiplexed dichroic liquid crystal display

Due to the conflicting demands of modern aircraft for increased systems/sensors and the decrease in cockpit panel size, weight, volume, and power, conventional discrete/dedicated methods of display and control are fast becoming obsolete. A means is sought to integrate the control and display into multifunctional programmable devices, thus giving the ability to increase system functions and yet conserve panel space. A potential solution to the control portion of the problem has come to be known as the Integrated Control Panel (ICP) approach. Flat panel display technology and controls using programmable flat panel displays with transparent capacitive touch control overlays offer the largest potential advantages. The flat panel display made of varistor-multiplexed dichroic liquid crystal (LCD) developed by GE in recent years appears to offer the ideal monochrome solution.

Whitton, I. J.↗