Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Asymptotic geometric phase and purity for phase qubit dispersively coupled to lossy LC circuit

Analytical descriptions of the geometric phases (GPs) for the total system and subsystems are studied for a current biased Josephson phase qubit strongly coupled to a lossy LC circuit in the dispersive limit. It is found that, the GP and purity depend on the damping parameter which leads to the phenomenon of GP death. Coherence parameter delays the phenomenon of a regular sequence of deaths and births of the GP. The asymptotic behavior of the GP and the purity for the qubit-LC resonator state closely follow that for the qubit state, but however, for the LC circuit these asymptotic values are equal to zero. - Highlights: > The model of a current biased Josephson phase qubit, strongly coupled to loss LC circuit, is considered. > Analytical descriptions of the geometric phase (GP) of this model, in the dispersive limit, are studied. > The GP and purity depend on the dissipation which leads to the GP death phenomenon. > Coherence parameter delays the phenomenon of a regular sequence of deaths and births of the GP.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entangled Coherent States Generation in two Superconducting LC Circuits

We proposed a novel pure electronic (solid state) device consisting of two superconducting LC circuits coupled to a superconducting flux qubit. The entangled coherent states of the two LC modes is generated through the measurement of the flux qubit states. The interaction of the flux qubit and two LC circuits is controlled by the external microwave control lines. The geometrical structure of the LC circuits is adjustable and makes a strong coupling between them achievable. This entangled coherent state generator can be realized by using the conventional microelectronic fabrication techniques which increases the feasibility of the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ADMX SLIC: Results from a Superconducting $\textit{LC}$ Circuit Investigating Cold Axions

Axions are a promising cold dark matter candidate. Haloscopes, which use the conversion of axions to photons in the presence of a magnetic field to detect axions, are the basis of microwave cavity searches such as the Axion Dark Matter eXperiment (ADMX). To search for lighter, low frequency axions in the sub-2 × 10 –7 eV (50 MHz) range, a tunable lumped-element $\textit{LC}$ circuit has been proposed. For the first time, through ADMX SLIC (Superconducting $\textit{LC}$ Circuit Investigating Cold Axions), a resonant $\textit{LC}$ circuit was used to probe this region of axion mass-coupling space. The detector used a superconducting $\textit{LC}$ circuit with piezoelectric driven capacitive tuning. The axion mass and corresponding frequency ranges 1.7498–1.7519 × 10 –7 eV (42.31–42.36 MHz), 1.7734–1.7738 × 10 –7 eV (42.88–42.89 MHz), and 1.8007–1.8015 × 10 –7 eV (43.54–43.56 MHz) were covered at magnetic fields of 4.5 T, 5.0 T, and 7.0 T, respectively. Exclusion results from the search data, for coupling below 10 –12 GeV –1 , are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of carbonyldiimidazole as a derivatization agent for the detection of pinacolyl alcohol, a forensic marker for Soman, by EI-GC–MS and LC-HRMS in official OPCW proficiency test matrices

Pinacolyl alcohol (PA), a key forensic marker for the nerve agent Soman (GD), is a particularly difficult analyte to detect by various analytical methods. In this work, we have explored the reaction between PA and 1,1'-carbonyldiimidazole (CDI) to yield pinacolyl 1H-imidazole-1-carboxylate (PIC), a product that can be conveniently detected by gas chromatography–mass spectrometry (GC–MS) and liquid chromatography-high-resolution mass spectrometry (LC-HRMS). Regarding its GC–MS profile, this new carbamate derivative of PA possesses favorable chromatographic features such as a sharp peak and a longer retention time (RT = 16.62 min) relative to PA (broad peak and short retention time, RT = 4.1 min). Additionally, the derivative can also be detected by LC-HRMS, providing an avenue for the analysis of this chemical using this technique where PA is virtually undetectable unless present in large concentrations. From a forensic science standpoint, detection of this low molecular weight alcohol signals the past or latent presence of the nerve agent Soman (GD) in a given matrix (i.e., environmental or biological). The efficiency of the protocol was tested separately in the analysis and detection of PA by EI-GC–MS and LC-HRMS when present at a 10 μg/mL in a soil matrix featured in the 44th PT and in a glycerol-rich liquid matrix featured in the 48th Official Organization for the Prohibition of Chemical Weapons (OPCW) Proficiency Test when present at a 5 μg/mL concentration. In both scenarios, PA was successfully transformed into PIC, establishing the protocol as an additional tool for the analysis of this unnatural and unique nerve agent marker by GC–MS and LC-HRMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗

Simple Sodium Dodecyl Sulfate-Assisted Sample Preparation Method for LC-MS-based Proteomic Applications

Sodium dodecyl sulfate (SDS) is one of the most popular laboratory reagents used for highly efficient biological sample extraction; however, SDS presents a significant challenge to LC-MS-based proteomic analyses due to its severe interference with reversed-phase LC separations and electrospray ionization interfaces. This study reports a simple SDS-assisted proteomic sample preparation method facilitated by a novel peptide-level SDS removal protocol. After SDS-assisted protein extraction and digestion, SDS was effectively (>99.9%) removed from peptides through ion substitution-mediated DS- precipitation with potassium chloride (KCl) followed by {approx}10 min centrifugation. Excellent peptide recovery (>95%) was observed for less than 20 {mu}g of peptides. Further experiments demonstrated the compatibility of this protocol with LC-MS/MS analyses. The resulting proteome coverage from this SDS-assisted protocol was comparable to or better than those obtained from other standard proteomic preparation methods in both mammalian tissues and bacterial samples. These results suggest that this SDS-assisted protocol is a practical, simple, and broadly applicable proteomic sample processing method, which can be particularly useful when dealing with samples difficult to solubilize by other methods.

59 BASIC BIOLOGICAL SCIENCES↗

Online supercritical fluid extraction mass spectrometry (SFE-LC-FTMS) for sensitive characterization of soil organic matter

We report a novel technical approach for subcritical fluid extraction (SFE) for organic matter characterization in complex matrices such as soil. The custom platform combines on-line SFE with micro-solid phase extraction, nano liquid chromatography (LC), electrospray ionization and Fourier transform mass spectrometry (SFE-LC-FTMS). We demonstrated the utility of SFE-LC-FTMS, including results from both Orbitrap and FTICR MS, for analysis of complex mixtures of organic compounds in a solid matrix by characterizing soil organic matter in peat, a high-carbon soil. For example, in a single experiment, >6000 molecular formulas can be assigned based upon FTICR MS data from 1–50 μL of soil samples (roughly 1–50 mg of soil, dependent on soil density), nearly twice that typically obtained from direct infusion liquid solvent extraction (LSE) from an order of magnitude larger volume of the same soil. The detected species consisted predominately of lipid-like, lignin-like and protein-like compounds, based on their O/C and H/C ratios, with predominantly CHO and CHONP molecular compositions. These results clearly demonstrate that SFE has the potential to effectively extract a variety of molecular species and could become an important member of a suite of extraction methods for studying SOM and other natural organic matter. This is especially true when comprehensive coverage, minimal sample volumes, and high sensitivity are required, or when the presence of organic solvent residue in residual soil is problematic. Lastly, the SFE based extraction protocol could potentially enable spatially resolved characterization of organic matter in soil with a resolution of ~1 mm3 to facilitate studies probing the spatial heterogeneity of soil.

54 ENVIRONMENTAL SCIENCES↗

Improved Quality Control Processing of Peptide-centric LC-MS Proteomics Data

In the analysis of differential peptide peak intensities (i.e., abundance measures), LC-MS analyses with poor quality peptide abundance data can bias downstream statistical analyses and hence the biological interpretation for an otherwise high quality data set. Although considerable effort has been placed on assuring the quality of the peptide identification with respect to spectral processing, to date quality assessment of the subsequent peptide abundance data matrix has been limited to a subjective visual inspection of run-by-run correlation or individual peptide components. Identifying statistical outliers is a critical step in the processing of proteomics data as many of the downstream statistical analyses (e.g., ANOVA) rely upon accurate estimates of sample variance, and their results are influenced by extreme values. Results: We describe a multivariate statistical strategy for the identification of LC-MS runs with extreme peptide abundance distributions. Comparison with current method (run-by-run correlation) demonstrates the significantly better rate of identification of outlier runs by the multivariate strategy. Simulation studies also suggest this strategy significantly outperforms correlation alone in the identification of statistically extreme LC-MS runs.

59 BASIC BIOLOGICAL SCIENCES↗

A Comparative Analysis of Computational Approaches to Relative Protein Quantification Using Peptide Peak Intensities in Label-free LC-MS Proteomics Experiments

Liquid chromatography coupled with mass spectrometry (LC-MS) is widely used to identify and quantify peptides in complex biological samples. In particular, label-free shotgun proteomics is highly effective for the identification of peptides and subsequently obtaining a global protein profile of a sample. As a result, this approach is widely used for discovery studies. Typically, the objective of these discovery studies is to identify proteins that are affected by some condition of interest (e.g. disease, exposure). However, for complex biological samples, label-free LC-MS proteomics experiments measure peptides and do not directly yield protein quantities. Thus, protein quantification must be inferred from one or more measured peptides. In recent years, many computational approaches to relative protein quantification of label-free LC-MS data have been published. In this review, we examine the most commonly employed quantification approaches to relative protein abundance from peak intensity values, evaluate their individual merits, and discuss challenges in the use of the various computational approaches.

Environmental Molecular Sciences Laboratory↗

Large-Scale and Deep Quantitative Proteome Profiling Using Isobaric Labeling Coupled with Two-Dimensional LC-MS/MS

Comprehensive, quantitative information on abundances of proteins and their post-translational modifications (PTMs) can potentially provide novel biological insights into diseases pathogenesis and therapeutic intervention. Herein, we introduce a quantitative strategy utilizing isobaric stable isotope-labelling techniques combined with two-dimensional liquid chromatography-tandem mass spectrometry (2D-LC-MS/MS) for large-scale, deep quantitative proteome profiling of biological samples or clinical specimens such as tumor tissues. The workflow includes isobaric labeling of tryptic peptides for multiplexed and accurate quantitative analysis, basic reversed-phase LC fractionation and concatenation for reduced sample complexity, and nano-LC coupled to high resolution and high mass accuracy MS analysis for high confidence identification and quantification of proteins. This proteomic analysis strategy has been successfully applied for in-depth quantitative proteomic analysis of tumor samples, and can also be used for integrated proteome and PTM characterization, as well as comprehensive quantitative proteomic analysis across samples from large clinical cohorts.

Environmental Molecular Sciences Laboratory↗

Tag you're it: Application of stable isotope labeling and LC-MS to identify the precursors of specialized metabolites in plants

Untargeted liquid chromatography/mass spectrometry (LC-MS) can contribute a comprehensive and unbiased picture of the metabolic space of plants. These data can be used to quantify natural metabolite variation for genome wide association studies, to compare global metabolic responses from environmental or genetic perturbations, and to identify previously undescribed metabolites in Nature. A major limitation with untargeted metabolomics is the classification and identification of the thousands of metabolite features that can be detected in a single analytical run. Isotopic labeling improves the informational value of these datasets by categorizing metabolites as being derived from specific upstream precursors and/or to known metabolic pathways. When a 13 C-labeled precursor is fed to either a plant or tissue, the downstream metabolites produced from it have a higher m/z value than the molecules in the pre-existing pool, generating an m/z peak pair that can be specifically identified within the MS data. In this paper, we outline methods and principles to consider when supplementing untargeted MS data with isotopic labeling, including how to choose the appropriate isotopic label, grow and feed plant tissues to maximize label uptake and incorporation into derivatives, optimize LC-MS methods, and interpret the resulting labeling data. Although the focus here is on annotation of amino acid-derived metabolites using LC-MS, we anticipate that the methods are generally adaptable to other precursors, plant species, and chromatographic approaches.

59 BASIC BIOLOGICAL SCIENCES↗

Metabolic profiling associated with autophagy of human placenta-derived mesenchymal stem cells by chemical isotope labeling LC−MS

Autophagy has been reported to have a pivotal role in maintaining stemness, regulating immunomodulation and enhancing the survival of mesenchymal stem cells (MSCs). However, the effect of autophagy on MSC metabolism is largely unknown. Here, we report a workflow for examining the impact of autophagy on human placenta-derived MSC (hPMSC) metabolome profiling with chemical isotope labeling (CIL) LC−MS. Rapamycin or 3-methyladenine was successfully used to induce or inhibit autophagy, respectively. Then, {sup 12}C- and {sup 13}C-dansylation labeling LC−MS were used to profile the amine/phenol submetabolome. A total of 935 peak pairs were detected and 50 metabolites were positively identified using the dansylation metabolite standards library, and 669 metabolites were putatively identified based on an accurate mass match in metabolome databases. {sup 12}C/{sup 13}C-p-dimethylaminophenacyl bromide labeling LC−MS was used to analyze the carboxylic acid submetabolome; 4736 peak pairs were detected, among which 33 metabolites were positively identified in the dimethylaminophenacyl metabolite standards library, and 3007 metabolites were putatively identified. PCA/OPLS-DA analysis combined with volcano plots and Venn diagrams was used to determine the significant metabolites. Metabolites pathway analysis demonstrated that hPMSCs appeared to generate more ornithine with the arginine and proline metabolism pathway and utilized more pantothenic acid to synthesize acetyl-CoA in the beta-alanine metabolism pathway when autophagy was activated. Meanwhile, acetyl-CoA conversion to fatty acids led to accumulation in the fatty acid biosynthesis pathway. In contrast, when autophagy was suppressed, a reduction in metabolites demonstrated weakened metabolic activity in these metabolic pathways. Our research provides a more comprehensive understanding of hPMSC metabolism associated with autophagy.

60 APPLIED LIFE SCIENCES↗

Highly efficient pulsed power supply system with a two-stage LC generator and a step-up transformer for fast capillary discharge soft x-ray laser at shorter wavelength

Highly efficient and compact pulsed power supply system for a capillary discharge soft x-ray laser (SXRL) has been developed. The system consists of a 2.2 {mu}F two-stage LC inversion generator, a 2:54 step-up transformer, a 3 nF water capacitor, and a discharge section with a few tens of centimeter length capillary. Adoption of the pulsed transformer in combination with the LC inversion generator enables us to use only one gap switch in the circuit for charging the water capacitor up to about 0.5 MV. Furthermore, step-up ratio of a water capacitor voltage to a LC inversion generator initial charging voltage is about 40 with energy transfer efficiency of about 50%. It also leads to good reproducibility of a capillary discharge which is necessary for lasing a SXRL stably. For the study of the possibility of lasing a SXRL at shorter wavelength in a small laboratory scale, high-density and high-temperature plasma column suitable for the laser can be generated relatively easily with this system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Separation of thorium (IV) from lanthanide concentrate (LC) and water leach purification (WLP) residue

Thorium (IV) content in industrial residue produced from rare earth elements production industry is one of the challenges to Malaysian environment. Separation of thorium from the lanthanide concentrate (LC) and Water Leach Purification (WLP) residue from rare earth elements production plant is described. Both materials have been tested by sulphuric acid and alkaline digestions. Th concentrations in LC and WLP were determined to be 1289.7 ± 129 and 1952.9±17.6 ppm respectively. The results of separation show that the recovery of Th separation from rare earth in LC after concentrated sulphuric acid dissolution and reduction of acidity to precipitate Th was found 1.76-1.20% whereas Th recovery from WLP was less than 4% after concentrated acids and alkali digestion processes. Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) was used to determine Th concentrations in aqueous phase during separation stages. This study indicated that thorium maybe exists in refractory and insoluble form which is difficult to separate by these processes and stays in WLP residue as naturally occurring radioactive material (NORM)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LC-IMS-MS Feature Finder. Detecting Multidimensional Liquid Chromatography, Ion Mobility, and Mass Spectrometry Features in Complex Datasets

We introduce a command line software application LC-IMS-MS Feature Finder that searches for molecular ion signatures in multidimensional liquid chromatography-ion mobility spectrometry-mass spectrometry (LC-IMS-MS) data by clustering deisotoped peaks with similar monoisotopic mass, charge state, LC elution time, and ion mobility drift time values. The software application includes an algorithm for detecting and quantifying co-eluting chemical species, including species that exist in multiple conformations that may have been separated in the IMS dimension.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon dioxide (CO2) flux, amplicon sequencing and liquid chromatography–mass spectrometry (LC-MS) data for pyrogenic organic matter (PYOM) amended soil incubations in lab, Madison, WI, 2021-22

This dataset comprises soil-pyrogenic organic matter (PyOM) incubation experiments conducted in a laboratory setting. The focus was on measuring carbon dioxide (CO2) flux emitted in the headspace of incubation jars over a one-month period. The aim was to estimate carbon mineralization from two different carbon fractions in PyOM, as well as carbon mineralization from soil organic carbon (SOC). Bacterial and fungal community profiles were tracked at various time points during the incubation to observe changes in the overall community and specific responders to PyOM. LC-MS analysis of soil samples was also performed to monitor changes in the soil's chemical composition.The provided dataset includes processed CO2 flux measurements obtained from the Picarro-multiplexer measurement setup for each sample incubation jar. This data is available in the "CO2Flux.csv" file. Additionally, the dataset includes CO2 flux data partitioned to estimate mean carbon mineralization from the two PyOM carbon fractions, bulk PyOM, and SOC. The cumulative carbon mineralization data is provided in "cml_respired.csv," while the rate of carbon mineralization data is in "rate_respired.csv." The file "cml_respired_lastcyc.csv" contains cumulative carbon mineralization data for the PyOM carbon fractions, bulk PyOM, and SOC throughout the entire incubation period.For the LC-MS analysis, the raw data can be found in the "20220721_NZ_PeakHeights_FinalAnalysis.csv" file, while sample metadata is provided in "20220721_NZpilot_Metadata.csv". Processed LC-MS data is available in the file "20220721_NZ_FINAL_msdat_sub3.csv". Lastly, the dataset includes the relative abundance data for bacterial genera that exhibited a significant positive response to the addition of PyOM produced at 350 degrees Celsius, which can be found in "resp_genera_350.csv".

54 ENVIRONMENTAL SCIENCES↗

The clinical impact of recent advances in LC-MS for cancer biomarker discovery and verification

Mass spectrometry-based proteomics has become an indispensable tool in biomedical research with broad applications ranging from fundamental biology, systems biology, and biomarker discovery. Recent advances in LC-MS have made it become a major technology in clinical applications, especially in cancer biomarker discovery and verification. To overcome the challenges associated with the analysis of clinical samples, such as extremely wide dynamic range of protein concentrations in biofluids and the need to perform high throughput and accurate quantification, significant efforts have been devoted to improve the overall performance of LC-MS bases clinical proteomics. In this review, we summarize the recent advances in LC-MS in the aspect of cancer biomarker discovery and quantification, and discuss its potentials, limitations, and future perspectives.

Environmental Molecular Sciences Laboratory↗

Assessment of the LC-2 Prelaunch Fatigue Spectra of the CM-to-SM Flange Weld

The pad stay and rollout components of the Ares I-X life cycle can generate cyclic stress oscillations to the vehicle that could initiate and grow fatigue cracks from weld defects. The Ares I-X Project requested that a study be performed to determine if stabilization of the vehicle is required to reduce the stresses that could initiate and grow fatigue cracks at the flange-to-skin weld of the Command Module (CM) and Service Module (SM) interface. A fatigue crack growth analysis was conducted that used loads (LC-2) and stress analyses developed by the Ares I-X Project and utilized material data and analysis methods developed by a critical initial flaw size (CIFS) analysis conducted by NASA Engineering and Safety Center (NESC) for the Upper Stage Simulator (USS) of the Ares I-X vehicle. A full CIFS analysis for the CM-to-SM flange-to-skin weld was not performed because the full flight spectrum was not provided and was not necessary to answer the question posed by the Ares I-X Project. Instead, an approach was developed to determine if the crack growth due to the pad stay and rollout components of the flight spectrum would adversely influence the CIFS. The approach taken used a number of conservative assumptions that eliminated the need for high-fidelity analyses and additional material testing, but still provided a bounding solution for the uncertainties of the problem. The results from this analysis indicate that the LC-2 pad stay and rollout spectrum components would not produce significant fatigue crack growth on the CM-to-SM flange-to-skin weld. Thus, from a fatigue crack growth standpoint, no stabilization is required to reduce the LC-2 pad stay and rollout cyclic stresses on the CM-to-SM flange-to-skin weld.

Dawicke, David S.↗