A Superbend X-Ray Microdiffraction Beamline at the Advanced Light Source

Beamline 12.3.2 at the Advanced Light Source is a newly commissioned beamline dedicated to x-ray microdiffraction. It operates in both monochromatic and polychromatic radiation mode. The facility uses a superconducting bending magnet source to deliver an X-ray spectrum ranging from 5 to 22 keV. The beam is focused down to {approx} 1 um size at the sample position using a pair of elliptically bent Kirkpatrick-Baez mirrors enclosed in a vacuum box. The sample placed on high precision stages can be raster-scanned under the microbeam while a diffraction pattern is taken at each step. The arrays of diffraction patterns are then analyzed to derive distribution maps of phases, strain/stress and/or plastic deformation inside the sample.

36 MATERIALS SCIENCE↗

High Magnetic Anisotropy and Magnetocaloric Effects in Single-Crystal Cr 2 Te 3

Here, we report a systematic investigation of anisotropic magnetocaloric effects in single-crystal Cr 2 Te 3 . Single-crystal samples are synthesized by chemical vapor transport and characterized by X-ray and Laue diffraction methods. The maximum magnetic entropy change –ΔS M max is 4.50 J kg –1 K –1 for the easy c-axis (3.36 J kg –1 K –1 for the hard axis along ab-plane), and the relative cooling power (RCP) is 296.7 J kg –1 for the easy c-axis (183.84 J kg –1 for the hard axis along ab-plane) for a magnetic field change of 9 T near the Curie temperature. The magneto-crystalline anisotropy constant K u is estimated to be 580.12 kJ m –3 at 140 K, decreasing to 148.60 kJ m –3 at 168 K. Meanwhile, the maximum of the rotational magnetic entropy change –ΔS M R (T, H) between the c-axis and the ab-plane is about 1.14 J kg –1 K –1 for magnetic-field change of 9 T. The critical exponents are estimated by analyzing magnetocaloric effects, which indicate a 2D-Ising type magnetic system. The accuracy of estimated critical exponents is verified by scaling analysis. The maximum magnetic entropy change –ΔS M max ≈ 5.25 J kg –1 K –1 (along the c-axis) and the corresponding adiabatic temperature change ΔT ad ≈ 3.31 K (along the c-axis) are estimated by analyzing heat capacity measurements with a magnetic field up to 9 T.

36 MATERIALS SCIENCE↗

Quantitative measurement of hard x-ray spectra for high intensity laser produced plasma

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One dimensional focusing with high numerical aperture multilayer Laue lens

Multilayer Laue lenses (MLLs) capitalize on the developments in multilayer deposition technologies for fabricating reflective coatings, specifically undertaken for EUV lithography, where layer thicknesses of several nanometers can be achieved. MLLs are deposited layer by layer, with their thicknesses following the zone plate law, and then pieces are sliced and extracted for use in focusing. Rays are reflected in the Laue geometry. The efficiency of a MLL can be very high, and is maximized by making the slice equal to about a half Pendellosung period so that most energy is transferred from the undiffracted to the diffracted beam, and by ensuring that the Bragg condition is met at each point in the zone plate. This latter condition requires that the layers are tilted to the beam by an amount that varies with layer position; e.g. for focusing a collimated beam, the layers should be normal to a cylinder of radius of twice the focal length. We have fabricated such tilted-zone MLLs and find that they exhibit improved efficiency across their entire pupil as compared with parallel-zone MLLs. This leads to a higher effective NA of the optic and hence higher resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-vacuum multi-modal monochromator for synchrotron-based hard x-ray micro-imaging

The original monochromator design we present consists in a high-vacuum vessel comprising three monochromators mounted side-by-side: a Lauë/Lauë, a Bragg/Bragg, and a double-multilayer monochromator. The selection of one monochromator type is done remotely by sliding laterally the crystal support in the monochromator vessel. In this way, exotic combinations such as Lauë/Bragg are also possible. Installation and commissioning of the new monochromator at ESRF beamline ID19 was carried out 2013-2014 (the multilayers not being installed yet). Beamline ID19 offers not only superb beam characteristics for phase-contrast imaging with a high level of sensitivity but also compared to other synchrotron X-ray imaging facilities a large beam of currently up to 7 cm × 1.3 cm. A wide energy range can be accessed in a fixed-exit mode (depending on the optics chosen the accessible energy range is between 10 keV and 200 keV). A beryllium exit window (10 cm × 10 cm active opening) completes the monochromator assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Curved focusing crystals for hard X-ray astronomy

A lens made by a properly arranged array of crystals can be used to focus x-rays of energy ranging from 30 to 500 keV for x-ray astronomy. Mosaic or curved crystals can be employed as x-ray optical elements. In this work self standing curved focusing Si and GaAs crystals in which the lattice bending is induced by a controlled damaging process on one side of planar crystals are characterized. Diffraction profiles in Laue geometry have been measured in crystals at x-ray energies E = 17, 59 and 120 keV. An enhancement of diffraction efficiency is found in asymmetric geometries.

36 MATERIALS SCIENCE↗

Coherent X-ray radiation generated by a relativistic electron in an artificial periodic structure

A theory of coherent X-ray radiation from a relativistic electron crossing an artificial periodic layered structure in the Laue scattering geometry is constructed. The expressions describing the spectral-angular radiation parameters are obtained. It is shown that the radiation yield in such a medium may substantially exceed the radiation yield in a crystal under analogous conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metrology of multilayer Laue lens structures by means of scanning electron microscope imaging

Scanning electron microscope images obtained on a cross-section of a sputtered multilayer structure have proven to be crucial for qualifying these films for their intended use as a multilayer Laue lens. The quality of the linear Fresnel zone structure is assessed by means of image processing and analyses, and these analyses are then used to qualify the structure for further lens processing. The image analysis as well as problematic SEM artifacts are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A peak position comparison method for high-speed quantitative Laue microdiffraction data processing

Indexing Laue patterns of a synchrotron microdiffraction scan can take as much as ten times longer than collecting the data, impeding efficient structural analysis using this technique. Here in this paper, a novel strategy is developed. By comparing the peak positions of adjacent Laue patterns and checking the intensity sequence, grain and phase boundaries are identified, requiring only a limited number of indexing steps for each individual grain. Using this protocol, the Laue patterns can be indexed on the fly as they are taken. The validation of this method is demonstrated by analyzing the microstructure of a laser 3D printed multi-phase/multi-grain Ni-based superalloy.

36 MATERIALS SCIENCE↗

Fabrication of wedged multilayer Laue lenses

We present a new method to fabricate wedged multilayer Laue lenses, in which the angle of diffracting layers smoothly varies in the lens to achieve optimum diffracting efficiency across the entire pupil of the lens. This was achieved by depositing a multilayer onto a flat substrate placed in the penumbra of a straight-edge mask. The distance between the mask and the substrate was calibrated and the multilayer Laue lens was cut in a position where the varying layer thickness and the varying layer tilt simultaneously satisfy the Fresnel zone plate condition and Bragg’s law for all layers in the stack. This method can be used to extend the achievable numerical aperture of multilayer Laue lenses to reach considerably smaller focal spot sizes than achievable with lenses composed of parallel layers.

42 ENGINEERING↗

A look-up table based approach to characterize crystal twinning for synchrotron X-ray Laue microdiffraction scans

An automated method has been developed to characterize the type and spatial distribution of twinning in crystal orientation maps from synchrotron X-ray Laue microdiffraction results. The method relies on a look-up table approach. Taking into account the twin axis and twin plane for plausible rotation and reflection twins, respectively, and the point group symmetry operations for a specific crystal, a look-up table listing crystal-specific rotation angle–axis pairs, which reveal the orientation relationship between the twin and the parent lattice, is generated. By comparing these theoretical twin–parent orientation relationships in the look-up table with the measured misorientations, twin boundaries are mapped automatically from Laue microdiffraction raster scans with thousands of data points. Finally, taking advantage of the high orientation resolution of the Laue microdiffraction method, this automated approach is also applicable to differentiating twinning elements among multiple twinning modes in any crystal system.

36 MATERIALS SCIENCE↗

Morphology of TiN thin films grown on MgO(001) by reactive dc magnetron sputtering

Thin TiN films were grown by reactive dc magnetron sputtering on single-crystalline MgO(001) substrates at a range of temperatures from room temperature to 600 deg. C. Structural characterization was carried out using x-ray diffraction and reflection methods. TiN films grow epitaxially on the MgO substrates at growth temperatures of 200 deg. C and above. The crystal coherence length determined from Laue oscillations and the Scherrer method agrees with x-ray reflection thickness measurements to 6% and within 3% for growth temperatures of 200 and 600 deg. C, respectively. For lower growth temperatures the films are polycrystalline but highly textured and porous.

36 MATERIALS SCIENCE↗

Method of making and structure of multilayer laue lens for focusing hard x-rays

A zone plate multilayer structure includes a substrate carrying a plurality of alternating layers respectively formed of tungsten silicide (WSi2) and silicon (Si). The alternating layers are sequentially deposited precisely controlling a thickness of each layer from a minimum thickness of a first deposited layer adjacent the substrate to a maximum thickness of a last deposited layer. The first minimum thickness layer has a selected thickness of less than or equal to 5 nm with the thickness of the alternating layers monotonically increasing to provide a zone plate multilayer structure having a thickness of greater than 12 μm (microns). The x-rays are diffracted in Laue transmission geometry by the specific arrangement of silicon and tungsten silicide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revealing the Subsurface Basal $\langle$a$\rangle$ Dislocation Activity in Magnesium Through Lattice Rotation Analysis

A method was proposed in this study to reveal the subsurface basal dislocation activity in Mg-Y alloy and determine the corresponding Burgers vector. This is achieved by correlating the slip directions of dislocations to the lattice rotation represented by the {0001} pole figure. The identified basal slip system by this approach was verified by micro-Laue diffraction. This method can be applied as a complementary method to the conventional slip trace analysis to study the dislocation behavior of Mg alloys.

36 MATERIALS SCIENCE↗

Depth-resolved Laue microdiffraction with coded apertures

A rapid data acquisition and reconstruction method is introduced to image the crystalline structure of materials and the associated strain and orientations at micrometre resolution using Laue diffraction. The method relies on scanning a coded aperture across the diffracted X-ray beam from broadband illumination and a reconstruction algorithm to resolve Laue microdiffraction patterns as a function of depth along the incident illumination path. It provides rapid access to full diffraction information for sub-micrometre volume elements in bulk materials. Both the theory and the experimental validation of this imaging approach are presented in this report.

36 MATERIALS SCIENCE↗

Alignment of sample position and rotation during in situ synchrotron X-ray micro-diffraction experiments using a Laue cross-correlation approach

Laue micro-diffraction has proven to be able to reveal material properties at the sub-grain scale for many polycrystalline materials and is now routinely available at several synchrotron facilities, providing an approach for nondestructive three-dimensional probing of the microstructures and mechanical states of materials. However, for in situ experiments, maintaining the positioning of the sample throughout the experiment, to achieve a good alignment of the characterized volumes, is a challenging issue. The aim of the present work is to address this problem by developing an approach based on digital image correlation of focused-beam Laue diffraction patterns. The method uses small changes in the diffraction signal as a focused X-ray beam is scanned over a surface region to allow corrections to be made for both sample lateral movement and rotation. The method is demonstrated using a tensile deformation experiment on an Al sample with 2.5 µm average grain size. The results demonstrate an accuracy of 0.5 µm for sample position registration and a precision in sample rotation of ~0.01°. Finally, the proposed method is fast to implement and does not require the use of additional surface markers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray refraction-contrast computed tomography images using dark-field imaging optics

If an x-ray beam containing internal information derived from sample soft tissue is incident upon a Laue-case analyzer, the beam will subsequently split into a forwardly diffracted beam and a separate diffracted beam. Using these beams acquired simultaneously, a refraction-contrast computed tomography (CT) imaging system for biomedical use with lower radiation dose can be easily realized, and has a high depicting capability on the soft tissues compared with conventional x-ray CT based on absorption contrast principles. In this paper, we propose an imaging system using dark-field imaging for CT measurement based on a tandem system of Bragg- and Laue-case crystals with two two-dimensional detectors, along with a data-processing method to extract information on refraction from the measured entangled intensities by use of rocking curve fitting with polynomial functions. Reconstructed images of soft tissues are presented and described.

07 ISOTOPE AND RADIATION SOURCES↗

Kinetic protein crystallography: a tool to watch proteins in action

Many proteins function in the crystalline state, making crystallography a tool that, beside structure, can address mechanism. By initiating biological turnover in the crystal, transient structural species form, which may be filmed 'on the fly' by Laue diffraction or captured by trapping methods. These strategies are jointly referred to as 'kinetic crystallography'. In this article, we review the general concepts of kinetic crystallography in the context of the conformational energy landscape of a protein. Whereas Laue diffraction is best suited to the investigation of cyclic, ultra-fast and light-triggered reactions, trapping approaches, on the other hand, are applicable to a wider range of biological systems but require care to avoid artefacts. Complementary methods - mainly UV/visible single-crystal spectroscopy - have proven essential to design, interpret and validate kinetic crystallography experiments. Achievements in the field as well as remaining puzzling questions are considered through the examination of recently published work: real-time-resolved crystallography of dimeric haemoglobin based on pump-probe Laue diffraction, temperature-trapping crystallography of acetylcholinesterase based on photo- and radio-induced ligand cleavage, and lattice-trapping crystallography of superoxide reductase based on product soaking and the combined use of X-ray diffraction and Raman spectroscopy.