High-Resolution Laser Spectroscopy on the Hyperfine Structure of 255Fm (𝑍=100)

We report on high-resolution laser spectroscopy of 255Fm (𝑇1/2=20 h), one of the heaviest nuclides available from reactor breeding. The hyperfine structures in two different atomic ground-state transitions at 398.4 nm and 398.2 nm were probed by in-source laser spectroscopy at the RISIKO mass separator in Mainz, using the perpendicularly illuminated laser ion source and trap (PI-LIST) high-resolution ion source. Experimental results were combined with hyperfine fields from various atomic ab initio calculations, in particular using multiconfiguration Dirac-Hartree-Fock theory, as implemented in grasp18. In this manner, the nuclear magnetic dipole and electric quadrupole moments were derived to be 𝜇=−0.75⁢(5) 𝜇N and 𝑄s=+5.84⁢(13) eb, respectively. The magnetic moment indicates occupation of the 𝜈⁢7/2⁢[613] Nilsson orbital, while the large quadrupole moment confirms strong, stable prolate deformation consistent with systematics in the heavy actinides. Comparisons with available expectation values from nuclear theory show good agreement, providing a stringent benchmark for the used theoretical models. These results revise earlier data and establish 255Fm as a reference isotope for future high-resolution studies.

Ezold, Julie [ORNL] (ORCID:0000000250550022)↗

A field programmable gate array-based time-resolved scaler for collinear laser spectroscopy with bunched radioactive potassium beams

A new data acquisition system including a Field Programmable Gate Array (FPGA) based time-resolved scaler was developed for laser-induced fluorescence and beam bunch coincidence measurements. The FPGA scaler was tested in a collinear laser-spectroscopy experiment on radioactive {sup 37}K at the BEam COoler and LAser spectroscopy (BECOLA) facility at the National Superconducting Cyclotron Laboratory at Michigan State University. A 1.29 μs bunch width from the buncher and a bunch repetition rate of 2.5 Hz led to a background suppression factor of 3.1 × 10{sup 5} in resonant photon detection measurements. The hyperfine structure of {sup 37}K and its isotope shift relative to the stable {sup 39}K were determined using 5 × 10{sup 4} s{sup −1} {sup 37}K ions injected into the BECOLA beam line. The obtained hyperfine coupling constants A({sup 2}S{sub 1/2}) = 120.3(1.4) MHz, A({sup 2}P{sub 1/2}) = 15.2(1.1) MHz, and A({sup 2}P{sub 3/2}) = 1.4(8) MHz, and the isotope shift δν{sup 39,} {sup 37} = −264(3) MHz are consistent with the previously determined values, where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Dipole Moment of {sup 57,59}Cu Measured by In-Gas-Cell Laser Spectroscopy

For the first time, in-gas-cell laser spectroscopy study of the {sup 57,59,63,65}Cu isotopes has been performed using the 244.164 nm optical transition from the atomic ground state of copper. The nuclear magnetic dipole moments for {sup 57,59,65}Cu relative to that of {sup 63}Cu have been extracted. The new value for {sup 57}Cu of mu({sup 57}Cu)=+2.582(7)mu{sub N} is in strong disagreement with the previous literature value but in good agreement with recent theoretical and systematic predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the absorption line profiles of water vapour isotopomers at 1.39 {mu}m using the methods of diode laser spectroscopy

The issues related to high-precision measurement of the absorption line profiles of water vapour and its isotopomers using the methods of diode laser spectroscopy in the near IR range aimed at the analysis and detection of greenhouse gases are considered. The absorption line shape of H{sub 2}{sup 16}O is investigated as a function of pressure of different buffer gases. The influence of the instrument function of the diode laser (DL) on the precision of measuring the line profile is studied. From fitting the profile of Doppler-broadened H{sub 2}{sup 16}O absorption line to a model profile the lasing line width of the DL with a fibre pigtail is determined. The frequencies and intensities of absorption lines of water isotopomers H{sub 2}{sup 16}O, H{sub 2}{sup 17}O, H{sub 2}{sup 18}O, and HDO are measured in the range of DL oscillation. Analytical spectral regions are chosen for distant probing of water vapour using an airborne lab. (laser spectroscopy)

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurements of water molecule isotopomer concentrations in a discharge of inert gas with addition of H{sub 2}O and D{sub 2} vapours by the method of external-cavity diode laser spectroscopy

Discharge plasma in inert gases with added water vapours and deuterium is studied by using the optimised diode laser spectroscopy with an external cavity. Formation of a spectrally dense grid of cavity transverse mode eigenfrequencies allows one to determine the parameters of Doppler broadening for absorption lines, a kinetic temperature of molecules, and their statistical sums. By using these parameters and the value of an absorption coefficient, correlations of concentrations are found for H{sub 2}O and HDO isotopomers at various ratios of plasma-forming gas components. An important contribution of initial gas molecules adsorbed on walls into the formation of plasma composition is stressed. It is found that the ratio of H{sub 2}O and HDO concentrations is the same at various ratios of H{sub 2}O and D{sub 2} concentrations in plasma-forming gases and is constant during the discharge burning process. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the hyperfine structure of emission lines of I{sub 2} molecules by the method of three-level laser spectroscopy

It is proposed to use narrow optical resonances, corresponding to the hyperfine structure components of emission transitions in I{sub 2}, as frequency references to stabilise laser radiation frequency in the spectral range from 0.8 to 1.3 {mu}m. To obtain such resonances and investigate the hyperfine structure of emission transitions, an experimental setup is built which consists of a saturated absorption laser spectrometer and a three-level laser spectrometer. Excitation is performed by the second harmonic of a cw Nd:YAG laser and probe radiation in the range from 968 to 998 nm is generated by an external cavity diode laser. The radiation beams from both lasers are combined in a cell with iodine vapour, excitation in the cell being performed in the regime of two counterpropagating waves. It is shown that upon phase modulation of exciting radiation, narrow resonances, having the form of the dispersion dependence, appear at the centre of Doppler lines in absorption and emission. These resonances can be used as references to stabilise the laser frequency. The results of the study of the hyperfine structure of emission lines at the (J' = 57, v' = 32) {yields} (J'' = 58, v'' = 48) transition upon excitation at the (J'' = 56, v'' = 0) {yields} (J' = 57, v'' = 32) transition are presented. (laser spectroscopy)

74 ATOMIC AND MOLECULAR PHYSICS↗

Determination of the antiproton-to-electron mass ratio by high precision laser spectroscopy of p-barHe{sup +}

The ASACUSA collaboration has carried out laser spectroscopy of an antiprotonic helium atom (p-barHe{sup +}: a Coulomb three-body system consisted of an antiproton, electron, and a helium nucleus) at CERN's Antiproton Decelerator facility and measured transition frequencies of p-barHe{sup +}. By comparing the measured frequencies with three-body QED calculations, the antiproton-to-electron mass ratio m{sub p{sup -}{sup bar}}/m{sub e} was determined. We recently developed a new laser system consisting of single-mode continuous-wave lasers, a femtosecond optical frequency comb, a pulse-amplified dye laser, and a chirp compensation, and achieved a precision of {approx}1x10{sup -8} on the p-barHe{sup +} transition frequencies, which was about one order of magnitude improvement. The comparison of the measured frequencies and the three-body QED calculations yielded the antiproton-to-electron mass ratio of m{sub p{sup -}{sup bar}}/m{sub e} = 1836.152 674(5). Combined with a constraint on the proton and antiproton charge-to-mass ratio of the TRAP group, a limit on any CPT-violating difference between the antiproton and proton charges and masses was also set as |Q{sub p}+Q{sub p{sup -}{sup bar}}|/Q{sub p}{approx}|m{sub p}-m{sub p{sup -}{sup bar}}|/m{sub p}<2x10{sup -9} at a confidence level of 90%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Fast Ion Beam Laser Spectroscopy of Ar{sup +}

Absolute measurements of spectral lines of Ar{sup +} ions using collinear and anticollinear geometries were performed. To provide a precise reference for the laser wavelength, iodine saturation spectroscopy was applied. The precision of this reference is effected by observing the beat node between the spectroscopy laser and the corresponding mode of a femtosecond laser frequency comb. Laser-induced fluorescence allowed to perform precision frequency measurements of an Ar{sup +} transition in collinear and anticollinear geometries simultaneously; then an exact relativistic formula for the absolute transition frequency V{sub 0} = {radical}(V{sub c}V{sub a}) was used. In this geometry the influence of ion source instabilities due to pressure and anode voltage fluctuations was minimized. The result is v{sub 0} = 485,573,619.7(3) MHz, which corresponds to {delta}v/v = 6*10{sup -10}. This represents an improvement of two orders of magnitude over the previous NIST published value.

74 ATOMIC AND MOLECULAR PHYSICS↗

A trap-based pulsed positron beam optimised for positronium laser spectroscopy

We describe a pulsed positron beam that is optimised for positronium (Ps) laser-spectroscopy experiments. The system is based on a two-stage Surko-type buffer gas trap that produces 4 ns wide pulses containing up to 5 × 10{sup 5} positrons at a rate of 0.5-10 Hz. By implanting positrons from the trap into a suitable target material, a dilute positronium gas with an initial density of the order of 10{sup 7} cm{sup −3} is created in vacuum. This is then probed with pulsed (ns) laser systems, where various Ps-laser interactions have been observed via changes in Ps annihilation rates using a fast gamma ray detector. We demonstrate the capabilities of the apparatus and detection methodology via the observation of Rydberg positronium atoms with principal quantum numbers ranging from 11 to 22 and the Stark broadening of the n = 2 → 11 transition in electric fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical fringe reduction technique for FM laser spectroscopy

A simple fringe reduction method for FM diode laser spectroscopy is discussed. The fringes can be effectively suppressed by using a modulation frequency that is an integral multiple of the free spectral range of the fringes. The technique is experimentally confirmed by two-tone FM spectroscopy of water vapor absorption lines. A factor of 20 fringe reduction is observed.

Chou, Nee-Yin↗

Numerical simulation of the Zeeman effect in neutral xenon from NIR diode-laser spectroscopy

We present a numerical method for simulating neutral xenon absorption spectra from diode-laser spectroscopy of the Zeeman-split 6S{sup '}[1/2]{yields}6P{sup '}[1/2] line at 834.682 nm-air in a galvatron's plasma. To simulate the spectrum, we apply a Voigt profile to a spectrum of {sigma}-transition lines of even- and odd-numbered isotopes computed from anomalous Zeeman and nonlinear Zeeman hyperfine structure theories, respectively. Simulated spectra agree well with Zeeman-split spectra measured from 30 to 300 G. A commercial nonlinear least-squares solver (LSQNONLIN) returns field strengths and translational plasma kinetic temperatures that minimize the error between simulated and experimental spectra. This work is a preamble to computing magnetic field topology and the speed distribution of neutral xenon particles in the plume of a Hall thruster from diode laser-induced fluorescence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoacoustic-based detector for infrared laser spectroscopy

In this contribution, we present an alternative detector technology for use in direct absorption spectroscopy setups. Instead of a semiconductor based detector, we use the photoacoustic effect to gauge the light intensity. To this end, the target gas species is hermetically sealed under excess pressure inside a miniature cell along with a MEMS microphone. Optical access to the cell is provided by a quartz window. The approach is particularly suitable for tunable diode laser spectroscopy in the mid-infrared range, where numerous molecules exhibit large absorption cross sections. Moreover, a frequency standard is integrated into the method since the number density and pressure inside the cell are constant. We demonstrate that the information extracted by our method is at least equivalent to that achieved using a semiconductor-based photon detector. As exemplary and highly relevant target gas, we have performed direct spectroscopy of methane at the R3-line of the 2v{sub 3} band at 6046.95 cm{sup −1} using both detector technologies in parallel. The results may be transferred to other infrared-active transitions without loss of generality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward the Development of Molten Salt Reactor Diagnostics based on Resonantly Enhanced Laser Spectroscopy

One emerging concern within the safeguards community is how to best ensure compliance with nuclear security regulations within molten salt reactor (MSR) facilities. This problem is nontrivial as molten salts used for fuel or coolant are highly corrosive, chemically complex, and inherently require high operational temperatures. Laser spectroscopy methods such as laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) have previously been suggested for molten salt diagnostics due to their compatibility with liquid phase samples and potential for in-situ measurements [1]. In the former, the laser is used to ionize the sample, allowing for the characteristic light from electronic de-excitation as the resultant plasma cools to be used for material characterization. In the latter, a tunable light source is set be resonant with a specific transition, resulting in element specific excitation and the emission of fluorescence light. In our previous work [2], we demonstrated that LIF could be used for the detection of fission fragments such as Nd in solution through the separation of laser scatter and fluorescence within the time domain. Here, we present progress towards two alternate measurement schemes: LIF measurements based on spectroscopic discrimination of fluorescence emissions and resonant LIBS measurements that induce plasma using a light source set to the resonant frequency of a specific electronic transition. Both methods aim to exploit resonant excitation methods to enhance the emitted signal. The studies may provide routes for element-specific detection of constituents within complicated matrices and a means to better understand the chemical behavior of lanthanides and actinides relevant to MSRs.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Probing Sizes and Shapes of Nobelium Isotopes by Laser Spectroscopy

Until recently, ground-state nuclear moments of the heaviest nuclei could only be inferred from nuclear spectroscopy, where model assumptions are required. Here, laser spectroscopy in combination with modern atomic structure calculations is now able to probe these moments directly, in a comprehensive and nuclear- model-independent way. In this work, we reported on unique access to the differential mean-square charge radii of 252,253,254 No, and therefore to changes in nuclear size and shape. State-of-the-art nuclear density functional calculations describe well the changes in nuclear charge radii in the region of the heavy actinides, indicating an appreciable central depression in the deformed proton density distribution in 252,254 No isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microgravity Diode Laser Spectroscopy Measurements in a Reacting Vortex Ring

The technique of Diode Laser Spectroscopy (DLS) with wavelength modulation is utilized to measure the concentration of methane in reacting vortex rings under microgravity conditions. From the measured concentration of methane, other major species such as water, carbon dioxide, nitrogen, and oxygen can be easily computed under the assumption of equilibrium chemistry with the method of Interactive Temperature with Assumed Chemistry (ITAC). The conserved scalar approach in modelling the coupling between fluid dynamics and combustion is utilized to represent the unknown variables in terms of the mixture fraction and scalar dissipation rate in conjunction with ITAC. Post-processing of the DLS measurements and the method of ITAC used in computing the species concentration are discussed. From the flame luminosity results, the increase in ring circulation appears to increase the fuel consumption rate inside the reacting vortex ring and the flame height for cases with similar fuel volumes. Preliminary results and application of ITAC show some potential capabilities of ITAC in DLS. The measured concentration of methane, and computed concentrations of water and carbon dioxide agree well with available results from numerical simulations.

Chen, Shin-Juh↗

Microgravity Diode Laser Spectroscopy Measurements in a Reacting Vortex Ring

The technique of Diode Laser Spectroscopy (DLS) with wavelength modulation is utilized to measure the concentration of methane in reacting vortex rings under microgravity conditions. From the measured concentration of methane, other major species such as water, carbon dioxide, nitrogen, and oxygen can be easily computed under the assumption of equilibrium chemistry with an iterative method called ITAC (Iterative Temperature with Assumed Chemistry). The conserved scalar approach in modelling the coupling between fluid dynamics and combustion is utilized to represent the unknown variables in terms of the mixture fraction and scalar dissipation rate in conjunction with ITAC. Post-processing of the DLS and the method used to compute the species concentration are discussed. From the flame luminosity results, ring circulation appears to increase the fuel consumption rate inside the reacting vortex ring and the flame height for cases with similar fuel volumes but different ring circulations. The concentrations of methane, water, and carbon dioxide agree well with available results from numerical simulations.

Chen, Shin-Juh↗

Nuclear and in-source laser spectroscopy with the ISAC yield station

A new decay station has been built for the ISAC facility at TRIUMF for the rapid and reliable characterization of radioactive ion beam (RIB) compositions and intensities with the capability of simultaneously collecting α, β, and γ decay data from RIB with intensities between a few and ≈10{sup 11} ions per second. It features user-friendly control, data acquisition, and analysis software. The analysis of individual decay time structures allows the unambiguous assignment of α and γ lines even with substantial isobaric contamination present. The capability for accurate half-life measurements is demonstrated with the example of {sup 46}K. The coupling of the yield station to the laser ion source, TRILIS, allows the correlation of radiometric data with automated laser frequency scans. First results of in-source laser spectroscopy measurements on astatine are discussed.

43 PARTICLE ACCELERATORS↗

Determination of local concentration of H{sub 2}O molecules and gas temperature in the process of hydrogen - oxygen gas mixture heating by means of linear and nonlinear laser spectroscopy

Employing the methods of linear absorption spectroscopy and nonlinear four-wave mixing spectroscopy using laserinduced gratings we have simultaneously measured the local concentrations of H{sub 2}O molecules and the gas temperature in the process of the H{sub 2} - O{sub 2} mixture heating. During the measurements of the deactivation rates of pulsed-laser excited singlet oxygen O{sub 2} (b {sup 1}{Sigma}{sup +}{sub g}) in collisions with H{sub 2} in the range 294 - 850 K, the joint use of the two methods made it possible to determine the degree of hydrogen oxidation at a given temperature. As the mixture is heated, H{sub 2}O molecules are formed by 'dark' reactions of H{sub 2} with O{sub 2} in the ground state. The experiments have shown that the measurements of tunable diode laser radiation absorption along an optical path through the inhomogeneously heated gas mixture in a cell allows high-accuracy determination of the local H{sub 2}O concentration in the O{sub 2} laser excitation volume, if the gas temperature in this volume is known. When studying the collisional deactivation of O{sub 2} (b {sup 1}{Sigma}{sup +}{sub g}) molecules, the necessary measurements of the local temperature can be implemented using laser-induced gratings, arising due to spatially periodic excitation of O{sub 2} (X{sup 3}{Sigma}{sup -}{sub g}) molecules to the b {sup 1}{Sigma}{sup +}{sub g} state by radiation of the pump laser of the four-wave mixing spectrometer. (laser spectroscopy)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗