Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LANDMARK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Landmark-embedded Gaussian process with applications for functional data modeling

In practice, we often need to infer the value of a target variable from functional observation data. A challenge in this task is that the relationship between the functional data and the target variable is very complex: the target variable not only influences the shape but also the location of the functional data. In addition, due to the uncertainties in the environment, the relationship is probabilistic, that is, for a given fixed target variable value, we still see variations in the shape and location of the functional data. To address this challenge, we present a landmark-embedded Gaussian process model that describes the relationship between the functional data and the target variable. A unique feature of the model is that landmark information is embedded in the Gaussian process model so that both the shape and location information of the functional data are considered simultaneously in a unified manner. Gibbs-Metropolis-Hasting algorithm is used for model parameters estimation and target variable inference. The performance of the proposed framework is evaluated by extensive numerical studies and a case study of nano-sensor calibration.

42 ENGINEERING↗

Three dimensional landmark templates

Three-dimensional surface templates are being used to identify and locate landmarks on Mars and Phobos. They can be aligned both with images and the MOLA map to help tie these two data types together. The Martian templates form a control network of well-defined and easily identified landmarks.

landmarks Mars Phobos MOLA three-dimensional surfa↗

Automated landmark identification for spacecraft navigation

An integrated approach to surface relative optical landmark tracking for spacecraft is being developed. Landmarks are defined as full digital topography/albedo maps and are determined from previous imaging and navigation data. Initially, this technique will speed up ground based optical navigation. Ultimately, it will enable on-board trajectory determination during orbital and landing maneuvers.

landmark↗

Volumetric Image Guidance Using Carina vs Spine as Registration Landmarks for Conventionally Fractionated Lung Radiotherapy

Purpose: To compare the relative accuracy of 2 image guided radiation therapy methods using carina vs spine as landmarks and then to identify which landmark is superior relative to tumor coverage. Methods and Materials: For 98 lung patients, 2596 daily image-guidance cone-beam computed tomography scans were analyzed. Tattoos were used for initial patient alignment; then, spine and carina registrations were performed independently. A separate analysis assessed the adequacy of gross tumor volume, internal target volume, and planning target volume coverage on cone-beam computed tomography using the initial, middle, and final fractions of radiation therapy. Coverage was recorded for primary tumor (T), nodes (N), and combined target (T+N). Three scenarios were compared: tattoos alignment, spine registration, and carina registration. Results: Spine and carina registrations identified setup errors {>=}5 mm in 35% and 46% of fractions, respectively. The mean vector difference between spine and carina matching had a magnitude of 3.3 mm. Spine and carina improved combined target coverage, compared with tattoos, in 50% and 34% (spine) to 54% and 46% (carina) of the first and final fractions, respectively. Carina matching showed greater combined target coverage in 17% and 23% of fractions for the first and final fractions, respectively; with spine matching, this was only observed in 4% (first) and 6% (final) of fractions. Carina matching provided superior nodes coverage at the end of radiation compared with spine matching (P=.0006), without compromising primary tumor coverage. Conclusion: Frequent patient setup errors occur in locally advanced lung cancer patients. Spine and carina registrations improved combined target coverage throughout the treatment course, but carina matching provided superior combined target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Landmark-Warped Emulators for Models with Misaligned Functional Response

Many computer models output functional data, and in some cases, these functional data have similar, but misaligned, shape characteristics. In this paper, we introduce a general approach for building emulators for computer models that output misaligned functional data when key values in the functional response (landmarks) can be easily identified. This approach has two main parts: modeling the aligned (using the landmarks) functional data, and modeling the functions that map the misaligned data to the aligned space (warping functions). As the warping functions are required to be monotonic, we give special attention to modeling monotonic functional response data. We discuss how our approach can be easily applied for a variety of typical emulators, such as Gaussian processes, Bayesian multivariate adaptive regression splines, and Bayesian additive regression trees, and how sensitivity analysis can be performed. We demonstrate our approach by building emulators for two applications: (1) a high-energy-density physics computer model used to simulate inertial confinement fusion ignition experiments, where model outputs are highly misaligned, and (2) a multiphysics continuum hydrocode used to simulate high-velocity impact experiments, where model outputs are only slightly misaligned. In case (1) traditional methods cannot be applied, while in (2) they can be applied, but the proposed method performs significantly better.

97 MATHEMATICS AND COMPUTING↗

A method for lunar roving vehicle position determination from three landmark observations with a sun compass

A simplified method is described for determining the position of the lunar roving vehicle on the lunar surface during Apollo 15. The method is based upon sun compass azimuth measurements of three lunar landmarks. The difference between the landmark azimuth and the sun azimuth is measured and the resulting data are voice relayed to the Mission Control Center for processing.

Blucker, T. J.↗

Comments on the figure of the moon from Apollo landmark tracking.

The selenographic positions of the observed lunar features are solved for, or estimated directly from, angular measurements made from the orbiting spacecraft (Apollo missions 8, 10, 11, 12, 14, and 15) to the landmark, using least-squares techniques. It appears that the radius values derived from the Apollo landmark data provide some proof of the existence of a displacement between the center of figure and center of mass of the moon along the earth-moon line. In addition, all three components of the estimated crater locations should be useful toward establishing a selenodetic reference system for interpreting or reducing earth-based observation data.

Wollenhaupt, W. R.↗

Use of known landmarks for satellite navigation

The use of known landmark measurements along with an onboard attitude reference system for estimation of both the ephemeris and attitude of an earth orbiting satellite is discussed. Simulation results are presented which show that, although known landmarks alone do not provide sufficient information to bound the uncertainty in attitude and ephemeris, they are useful in combination with other navigation aids, such as star tracking, ground tracking, or satellite tracking. An extended Kalman filter is used for optimal estimation. The result of using a smoothing algorithm is also shown.

White, R. L.↗

A landmark recognition and tracking experiment for flight on the Shuttle/Advanced Technology Laboratory (ATL)

The preliminary design of an experiment for landmark recognition and tracking from the Shuttle/Advanced Technology Laboratory is described. It makes use of parallel coherent optical processing to perform correlation tests between landmarks observed passively with a telescope and previously made holographic matched filters. The experimental equipment including the optics, the low power laser, the random access file of matched filters and the electro-optical readout device are described. A real time optically excited liquid crystal device is recommended for performing the input non-coherent optical to coherent optical interface function. A development program leading to a flight experiment in 1981 is outlined.

Welch, J. D.↗

Orbit/attitude estimation with LANDSAT Landmark data

The use of LANDSAT landmark data for orbit/attitude and camera bias estimation was studied. The preliminary results of these investigations are presented. The Goddard Trajectory Determination System (GTDS) error analysis capability was used to perform error analysis studies. A number of questions were addressed including parameter observability and sensitivity, effects on the solve-for parameter errors of data span, density, and distribution an a priori covariance weighting. The use of the GTDS differential correction capability with acutal landmark data was examined. The rms line and element observation residuals were studied as a function of the solve-for parameter set, a priori covariance weighting, force model, attitude model and data characteristics. Sample results are presented. Finally, verfication and preliminary system evaluation of the LANDSAT NAVPAK system for sequential (extended Kalman Filter) estimation of orbit, and camera bias parameters is given.

Hall, D. L.↗

Trajectory Reconstruction of the ST-9 Sounding Rocket Experiment Using IMU and Landmark Data

This paper presents trajectory reconstruction of the ST-9 sounding rocket experiment using the onboard IMU data and descent imagery. The raw IMU accelerometer measurements are first converted into inertial acceleration and then used in trajectory integration. The descent images are pre-processed using a map-matching algorithm and unique landmarks for each image are created. Using the converted IMU data and descent images, the result from dead-reckoning and the kinematic-fix approaches are first compared with the GPS measurements. Then, both the IMU data and landmarks are processed together using a batch least-squares filter and the position, velocity, stochastic acceleration, and camera orientation of each image are estimated. The reconstructed trajectory is compared with the GPS data and the corresponding formal uncertainties are presented. The result shows that IMU data and descent images processed with a batch filter algorithm provide the trajectory accuracy required for pin-point landing.

Park, Ryan S.↗

A Minimal State Augmentation Algorithm for Vision-Based Navigation without Using Mapped Landmarks

This paper describes MAVeN (Minimal State Augmentation Algorithm for Vision-Based Navigation), which is a new algorithm for vision-based navigation that has only 21 states, yet is able to track features in successive camera images and use them to propagate estimates of the spacecraft position and velocity. The filter dimension drops to 12 if attitude information is already available. The low filter dimension makes MAVeN a very reliable and practical algorithm for real-time flight implementation. The main idea is to project observed features onto a rough shape model of the ground surface, which are then used by the filter as pseudo-landmarks. The shape model is assumed to be known beforehand, as would be obtained from prior surveillance of the landing site from orbit. MAVeN does not require pre-mapped landmarks, so it is able to navigate terrain that has not been previously observed up close. This property is especially important for close proximity operations in small body missions where ground surface features are being seen for the first time at close range. MAVeN is also able to hover motionless above the ground without position error growth, which is unusual for this class of vision-based navigation algorithms.

San Martin, A. Miguel↗

Comparison of Spine, Carina, and Tumor as Registration Landmarks for Volumetric Image-Guided Lung Radiotherapy

Purpose: To assess the feasibility, reproducibility, and accuracy of volumetric lung image guidance using different thoracic landmarks for image registration. Methods and Materials: In 30 lung patients, four independent observers conducted automated and manual image registrations on Day 1 cone-beam computed tomography data sets using the spine, carina, and tumor (720 image registrations). The image registration was timed, and the couch displacements were recorded. The intraclass correlation was used to assess reproducibility, and the Bland-Altman analysis was used to compare the automatic and manual matching methods. Tumor coverage (accuracy) was assessed through grading the tumor position after image matching against the internal target volume and planning target volume. Results: The image-guided process took an average of 1 min for all techniques, with the exception of manual tumor matching, which took 4 min. Reproducibility was greatest for automatic carina matching (intraclass correlation, 0.90-0.93) and lowest for manual tumor matching (intraclass correlation, 0.07-0.43) in the left-right, superoinferior, and anteroposterior directions, respectively. The Bland-Altman analysis showed no significant difference between the automatic and manual registration methods. The tumor was within the internal target volume 62% and 60% of the time and was outside the internal target volume, but within the planning target volume, 38% and 40% of the time after automatic spine and automatic carina matching, respectively. Conclusion: For advanced lung cancer, the spine or carina can be used equally for cone-beam computed tomography image registration without compromising target coverage. The carina was more reproducible than the spine, but additional analysis is required to confirm its validation as a tumor surrogate. Soft-tissue registration is unsuitable at present, given the limitations in contrast resolution and the high interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction Displacement of Primary Tumor and Involved Lymph Nodes Relative to Anatomic Landmarks in Image Guided Radiation Therapy of Locally Advanced Lung Cancer

Purpose: To analyze primary tumor (PT) and lymph node (LN) position changes relative to each other and relative to anatomic landmarks during conventionally fractionated radiation therapy for patients with locally advanced lung cancer. Methods and Materials: In 12 patients with locally advanced non-small cell lung cancer PT, LN, carina, and 1 thoracic vertebra were manually contoured on weekly 4-dimensional fan-beam CT scans. Systematic and random interfraction displacements of all contoured structures were identified in the 3 cardinal directions, and resulting setup margins were calculated. Time trends and the effect of volume changes on displacements were analyzed. Results: Three-dimensional displacement vectors and systematic/random interfraction displacements were smaller for carina than for vertebra both for PT and LN. For PT, mean (SD) 3-dimensional displacement vectors with carina-based alignment were 7 (4) mm versus 9 (5) mm with bony anatomy (P<.0001). For LN, smaller displacements were found with carina- (5 [3] mm, P<.0001) and vertebra-based (6 [3] mm, P=.002) alignment compared with using PT for setup (8 [5] mm). Primary tumor and LN displacements relative to bone and carina were independent (P>.05). Displacements between PT and bone (P=.04) and between PT and LN (P=.01) were significantly correlated with PT volume regression. Displacements between LN and carina were correlated with LN volume change (P=.03). Conclusions: Carina-based setup results in a more reproducible PT and LN alignment than bony anatomy setup. Considering the independence of PT and LN displacement and the impact of volume regression on displacements over time, repeated CT imaging even with PT-based alignment is recommended in locally advanced disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unidentified landmark navigation.

Unidentified landmark navigation from orbiting vehicle by computer simulation, noting instrumentation accuracies

COMPUTER SIMULATION↗