Engineering PapersSearch

SEARCH · Engineering Papers

Results for “LAMINATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Life-cycle carbon footprint and total production potential of cross-laminated timber from California’s wildland-urban interface

The frequency, scale, and severity of wildfires are steadily increasing in the Western United States. Sustainable forest management practices through forest thinning could reduce the impact of wildfires and provide lumber for wood-based, long-lived, and low-carbon building materials. This study explores the potential for harvesting biomass in California (CA) to mitigate wildfire risk and provide multi-decade carbon storage in the form of cross-laminated timber (CLT) for use in buildings. First, we assessed biomass resource availability, finding that the total live hardwood and live softwood available in the wildland-urban interfaces (WUIs) across CA sums to 14.1 million metric tons (MMT) and 34.9 MMT, respectively, which contains the equivalent of 90 MMT of atmospheric carbon dioxide. Then, we conducted a life cycle assessment of CLT considering softwood and hardwood sources to provide insights into emissions and energy demand associated with utilization of the wood removed for wildfire risk management. We found that the net life cycle carbon footprint of live hardwood and softwood when including biogenic carbon storage/emissions is 414 and 317 kg CO2e/m3 CLT, respectively. To incorporate the timing of these emissions and uptake, we have also conducted a cradle-to-grave time-dependent global warming potential (GWP) analysis. The time-adjusted GWP for live hardwood and live softwood is −227 and −104 kg CO2e/m3 CLT, respectively. In terms of total CLT production potential, 0.03 and 0.005 million m3 CLT can be sourced from live softwood and hardwood, respectively, in WUI on gentle slopes in CA. The resulting insights and approaches from this study are broadly applicable to other forested regions and WUIs across the US and the world, and provide a holistic approach to use forest thinning as a wildfire mitigation strategy in combination with a novel approach for life cycle assessment of building materials with a limited dataset.

Bose, Baishakhi

Delamination and Buckling Analysis of a Laminated Component in a High-speed Permanent Magnet Motor

High-speed permanent magnet (PM) machines are widely used because of their high-power density and high efficiency. The high rotation speed also inevitably subjects the PMs to high centrifugal load, which might damage them due to their inherent mechanical vulnerability, such as a much lower tensile strength than the compressive strength. To robustly transfer the torque from the magnet to the shaft, the outer diameter of the laminated rotor core is larger than the inner diameter of the rotor frame to ensure tight contact while working at 20,000 rpm. Motor manufacturing requires the shrink-fit method to assemble the rotor frame and rotor core. However, after the shrink-fit assembly, unexpected local delamination and buckling are observed on the rotor core part. Utilizing finite element simulation, we study the internal stress of assembling these two parts at the provided interference. Simulation results indicate the reasons for the delamination and buckling of the rotor core part and provide suggestions for improving the assembly.

Lin, Lianshan

Heterogeneous field response of hierarchical polar laminates in relaxor ferroelectrics

Understanding the microscopic origin of the superior electromechanical response in relaxor ferroelectrics requires knowledge not only of the atomic-scale formation of polar nanodomains (PNDs) but also the rules governing the arrangements and stimulated response of PNDs over longer distances. Using x-ray coherent nanodiffraction, we show the staggered self-assembly of PNDs into unidirectional mesostructures that we refer to as polar laminates in the relaxor ferroelectric 0.68PbMg 1/3 Nb 2/3 O 3 -0.32PbTiO 3 (PMN-0.32PT). Here, we reveal the highly heterogeneous electric-field–driven responses of intra- and interlaminate PNDs and establish their correlation with the local strain and the nature of the PND walls. Our observations highlight the critical role of hierarchical lattice organizations on macroscopic material properties and provide guiding principles for the understanding and design of relaxors and a wide range of quantum and functional materials.

36 MATERIALS SCIENCE

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Effect of fiber sizing and glass fiber laminate hybridization on vibration damping and mechanical properties of banana fiber reinforced polypropylene composites

Modern automotive applications demand lightweight, multifunctional materials to reach mileage goals and natural fiber reinforced composites (NFRCs) are one of the classes of materials proposed as a solution. NFRCs exhibit good vibration damping properties and have low density, but are often limited by processing challenges, poor-fiber matrix compatibility and variable performance. Herein, we investigate non-woven wet-lay of comingled banana fiber (BF), recycled glass fiber (rGF), and polypropylene (PP) fibers to in situ sizing and preparation of composite feedstocks for compression molding. BF and rGF hybrids were prepared by stacking rGF layers during compression molding to produce composites with various fiber ratios. The effect of fiber content, in-situ sizing and ratio of BF to rGF on tensile, flexural and vibration damping performance are investigated. Key results are the significant increase in tensile strength by in situ sizing (40 % sized at 60 wt% BF) and in flexural modulus (+58 % sized at 60 wt% BF) and flexural strength (+41 % sized 60 wt% BF) compared to the unsized equivalent. For BF-rGF hybrid composites with40 wt% total fiber content, flexural strength and modulus were improved by 51 % and 231 % respectively for a 1:1 ratio BF:rGF compared to BF reinforced system. Lastly, identifying the cross-over point where damping and stiffness are optimized for a hybrid composite. These findings demonstrate that these composites can be used as alternative to synthetic fiber or mineral filled composites in automotive applications, particularly where weight reduction, vibration damping and stiffness are desired.

Banana fiber

Pigment removal from reverse-printed laminated flexible films by solvent-targeted recovery and precipitation

The solvent-targeted recovery and precipitation (STRAP) process separates and recovers the constituent resins in multilayer plastic packaging films by selective polymer dissolution. In this work, the cause of coloring in the STRAP-recycled polyethylene (PE) resins from postindustrial printed films was identified as decomposed diarylide pigments. Two different approaches are needed to completely remove the dissolved colorants during the STRAP process including (i) adding an activated carbon (AC) adsorbent to the solvent after polymer dissolution and (ii) proper mechanical filtration of the polymer-solvent cake to remove as much solvent from the cake as possible. Colorless recycled PE can be produced by a combination of the proposed approaches (choosing the proper solvent, adding an AC adsorbent, and doing proper mechanical filtration) with minimal accumulation of colorants in the recycled STRAP solvents. This study demonstrated that high-quality STRAP low-density PE can be obtained from printed plastic films, enhancing the potential circularity of these packaging materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

VitriEdge: Repairable & Durable Vitrimer Coatings for Wind Turbine Blade Leading Edges

The primary goal of this Level 1b incubator project was to explore the use of vitrimer coatings for repair of leading-edge erosion on end-of-life wind turbine blade surfaces, beyond coating strength of adhesion which has previously been demonstrated in the Level 1a project. Uniform vitrimer coatings (thickness: 400 µm) were applied to two end-of-life wind turbine blades for flexural, fatigue, and laminate tensile testing where the addition of the coating did not produce any statistical variation in tensile properties with minor drops in flexural strength for some laminate formulations. However, a <2% variation in storage modulus was measured for laminate structures (i.e., blade samples with vitrimer coatings) across 100,000 flexural cycles and upon laminate tensile failure, the vitrimer coatings displayed no visible signs of delamination. In addition, three methods to heal vitrimer coating damage was displayed: oven heating, addition of hot water, and a forced convection heat gun. All three heating and healing mechanisms demonstrated significant healing with scratch depths decreasing between 79-91% at healing times ranging between 1-min and 10-minutes. Finally, a water jet machine was used to simulate rain erosion for both the blade surfaces and vitrimer-coated blade surfaces where the diameter and depth of the damage was recorded as a function of exposure time, water pressure, height of exposure, and angle of exposure. Of interest, while the vitrimer coating did not significantly lessen the damage experienced during rain erosion, the addition of vitrimer composite coatings(5 wt.% mica addition) did result in a crack-resistant, durable coating capable of self-healing behavior and in all cases the angle of rain exposure was the most critical parameter explored. It is crucial to continue exploring this space where vitrimer coatings are of interest for both their self-healing properties and potential use as reversible adhesives.

17 WIND ENERGY

An Additively Manufactured Fe-3Si Stator for a High-Performance Electrical Motor

Additive manufacturing (AM) has the potential to produce novel high-performance electrical machines, enabling the direct printing of complex shapes and the simultaneous processing of multiple feedstocks in a single build. We examined the properties and functional performance of Fe-3 wt.% Si materials that were printed via selective laser melting, machined down to thin laminates, and stacked to form a stator core of a prototype brushless permanent-magnet electrical motor. Big Area Additive Manufacturing of Nd2Fe14B (NdFeB)–polyphenylene sulfide (PPS) bonded magnets was performed, with them then being magnetized and used for the rotor. The magnetic, mechanical, and electrical properties of the as-printed and various heat-treated thin laminates and the back electromotive force (EMF) of the electrical motors at different rotational speeds were measured. The thin laminates exhibit a maximum relative permeability of 7494 at an applied field of 0.8 Oe and a core loss of about 20 W/lb at 60 Hz with the maximum induction of 15 kg. In addition to the demonstration of AM printing, motor assembly, and complete characterization of printed Fe-3 wt.% Si, this report highlights the areas of improvement needed in printing technologies to achieve AM built electrical motors and the need for isotropic microstructure refinements to make the laminates appropriate for high-mechanical-strength and low-loss rotational electrical devices.

36 MATERIALS SCIENCE

Numerical modeling and experimental validation of low velocity impact of woven GFRP/CFRP composites

Low-velocity impact of 2D woven glass fiber reinforced polymer (GFRP) and carbon fiber reinforced polymer (CFRP) composite laminates was studied experimentally and numerically. Hybrid laminates containing blocked layers of GFRP/CFRP/GFRP with all plies oriented at 0° were investigated. Relatively high impact energies were used to obtain full perforation of the laminate in a low-velocity impact setup. Numerical simulations were carried out using the in-house transient dynamics finite element code, Sierra/SM, developed at Sandia National Laboratories. A three-dimensional continuum damage model was used to describe the response of a woven composite ply. Two methods for handling delamination were considered and compared: (1) cohesive zone modeling and (2) continuum damage mechanics. The reduced model size achieved by omission of the cohesive zone elements produced acceptable results at reduced computational cost. Further, the comparison between different modeling techniques can be used to inform modeling decisions relevant to low velocity impact scenarios. The modeling was validated by comparing with the experimental results and showed good agreement in terms of predicted damage mechanisms and impactor velocity and force histories.

36 MATERIALS SCIENCE

Supersonic hot jet ablative testing and analysis of boron nitride nanotube hybrid composites

Boron nitride nanotubes (BNNTs) are high-strength, high-modulus nanotubes with high thermal and oxidative stabilities. Two hybrid composites were prepared with satin weave carbon fiber (CF) and resole-type phenolic resin: one with surface layers of BNNTs and one with alternating interlayers of BNNTs. The samples were subjected to hot jet tests that simulate realistic high-pressure-temperature conditions to understand the behavior of BNNTs under high-pressure erosion. Adding BNNTs to CF/phenolic laminates enhanced the ablation resistance by reinforcing the char material and mitigated localized thermal damage. Hybrid laminates exhibited up to 14% lower weight loss, 55% increase in flexural modulus, higher thermal diffusivity, and improved char yield and microstructure compared to CF/phenolic samples. The surface layer hybrid had many surviving nanotubes reinforcing the char and crystalline oxide structures that could mitigate further oxygen diffusion. Further, various characterization methods were used to deduce possible mechanisms and their products, indicating that BNNTs could serve as growth templates for direct crystalline boron oxide formation. Overall, hybrid BNNT/CF/phenolic laminates displayed better ablation resistance and favorable microstructure evolution under high-pressure conditions.

42 ENGINEERING

Sequential Stress Identifies Processing Defects in Bifacial Photovoltaic Modules That Limit Durability

Here, we use sequential stress to investigate hurdles to bifacial photovoltaic (PV) module durability from lamination defects. We test mini-modules with glass/glass (G/G) and glass/transparent-backsheet (G/TB) constructions using either ethylene vinyl acetate or polyolefin elastomer (POE) based encapsulants under a modified IEC 63209-2 sequential stress. This sequence includes multiple iterations of damp heat (DH200), full spectrum light exposure (A3), thermal cycling (TC50), and humidity/freeze (HF10). We compare indoor stress with outdoor exposure. Results show similar relative trends in degradation after a year outdoors compared to our first stress cycle. Subsequent stress cycles impart more severe damage than outdoor exposure for the short outdoor duration used here. Edge-pinch lamination defects in G/G mini-modules limit durability causing delamination and cell cracks. Conversely, we observe greater degradation in G/TB mini-modules compared to G/G in the later stages of the stress sequence when the backsheets are directly exposed to UV-containing light. Our results highlight: 1) the utility of sequential stress testing to uncover degradation modes in bifacial PV, 2) implications of using mini-modules for testing PV quality, and 3) the importance of lamination defects that must be avoided to ensure durability as the industry adopts G/G or G/TB packaging.

14 SOLAR ENERGY

Roll-to-Roll Manufacturing of Solid Oxide Fuel Cells

The overall goal of this project is to develop a high-volume electrode electrolyte assembly (EEA) production capability to significantly increase throughput of solid oxide fuel cell (SOFC) manufacturing and reduce the cost while maintaining the same level of performance. Specifically, four approaches will be adopted: 1) optimization of the lamination process and correlation of the EEA properties and performance with the lamination conditions; 2) scale up of the lamination process and demonstration of >10 ft of EEA; 3) further increase of the EEA throughput via slot-die coating and demonstration of > 5 m/min in coating the thick anode layer; and 4) minimization of the anode thickness to reduce material cost.

30 DIRECT ENERGY CONVERSION

Component-based SHGC determination of BIPV glazing for product comparison

Building-integrated photovoltaic (BIPV) systems are intrinsically designed to generate electricity and to provide at least one building-related function. When BIPV modules act as glazing products in windows, skylights or curtain walls, their ability to control the transmission of solar energy into the building must be characterised by a Solar Heat Gain Coefficient (SHGC) or g value (also known as Total Solar Energy Transmittance – TSET – or “solar factor”). For the comparison of BIPV glazing products consisting of one PV laminate and possibly further, conventional glazing layers separated by gas-filled cavities, the procedures documented in international standards for architectural glazing (e.g. ISO 9050 and EN 410) form a suitable starting point. Easily implemented modifications to these procedures are proposed to take both optical inhomogeneity (if relevant) and extraction of electricity from BIPV glazing units into account. Geometrically complex glazing and shading devices, and light-scattering glazing layers, are outside the scope of the proposed methodology; SHGC determination for obliquely incident solar radiation is also excluded. For these cases, the experimental calorimetric approach documented in [ISO 19467:2017; ISO 19467-2:2021] is recommended. The paper also presents results and conclusions from an implementation exercise and sensitivity study carried out by participants of the IEA-PVPS Task 15 on BIPV. The cell coverage ratio in the PV laminate, the thermal resistance offered by the glazing configuration, the choice of boundary conditions and the effect of extracting electricity were all identified as parameters which significantly affect the SHGC value determined for a given type of BIPV glazing. A practicable approach to accommodate the great variety of dimensions typical for BIPV glazing is also proposed. These findings should pave the way for modifying the existing component-based standards for architectural glazing to take the specific features of BIPV glazing into account.

14 SOLAR ENERGY

Hygrothermal aging effects on polyimide and acrylate-based adhesive materials in high-performance flat-flex cable assemblies

Flat-flex assemblies are widely used across a diverse range of technologies, including consumer electronics, automotive systems, aerospace and defense applications, and medical devices, due to their compact form factor and flexibility. However, environmental stressors like temperature and humidity are known to degrade performance over time, though the main mechanisms for degradation remain unknown. Here, in this work, we examined the aging behavior of copper/polyimide/adhesive laminate systems under varying temperature and humidity conditions, focusing on material degradation and its effects on mechanical and dielectric properties. Results show that peel strength and breakdown voltage decrease with exposure time, temperature, and humidity; spectroscopic characterization revealed that the adhesive, and not the polyimide, is the weak link in the material stack-up. The adhesive, identified as a butyl acrylate-acrylonitrile (BA-AN) copolymer, exhibited age-related spectral changes that correlated with exposure severity and duration. Hydrolysis at BA ester and AN nitrile groups was identified as the primary degradation mechanism, producing amides, acids, and alcohols. We developed a mechanistic model that connects kinetic parameters for BA-AN spectral band decay to peel strength and breakdown voltage, and implicates hydrolysis at the AN moiety, not BA, in performance decrements. Modeling predictions at ambient conditions indicate faster decline in peel strength than dielectric strength at early times, followed by plateauing of both properties at longer times. These findings provide critical insights into laminate aging mechanisms and highlight the importance of addressing BA-AN degradation to improve the long-term reliability of these systems in high-humidity environments.

organic

Solar Cell Metallization Wear is Sensitive to Loading Frequency

Here, we performed cyclic loading of photovoltaic laminates with precracked silicon cells to explore if and how loading frequency and contact pressure influence the ensuing gridline wear-out process. A measurement of parallel resistance across cracked gridlines on a laminated cell coupon was used as the metric for gridline electrical contact degradation. A statistical analysis of variance (ANOVA) analysis of the experimental results discerned that loading frequency is a more significant factor than contact pressure for gridline degradation.

14 SOLAR ENERGY