Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “L1B reflectance product”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Land Surface Reflectances from Geostationary Sensors

GEONEX is a processing pipeline that produces a suite of satellite land surface products using data streams from the latest geostationary (GEO) sensors including the GOES016/ABI and the Himawari-8/AHI. The suite, created collaboratively by scientists from NASA and NOAA, includes top-of-atmosphere (TOA) reflectances, land surface reflectances (LSRs), vegetation indices, LAI/fPAR, and other downstream products. As a key component of the GEONEX product processing, we have adapted the Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm to produce LSRs from the TOA data. Because the algorithm depends on building "stacks" of images, we first run internal geo-registration checks to ensure geo-spatial accuracy and consistency of the input (L1B) data before transferring them from the geostationary projection into a tile system in geographic grids. Scan-time is inferred from metadata and applied to calculate the sun-sensor angles for each grid cell. The MAIAC algorithm is run to detect clouds/shadows, estimate aerosol optical thickness (AOT), perform atmospheric corrections, and generate LSRs. We have processed 18-months (from 2016/04 onward) of AHI data over East Asia and Oceania at a 10-minute time step and 10-months (from 2018/01 onward) of ABI data over North and South Americas at a 15-minute time step. As a verification measure, we compare the GEONEX (AHI/ABI) surface reflectances with the standard MODIS products (MOD09GA) and the MODIS MAIAC products over pixels that have similar sun-view geometries. The results indicate general linear relationships between GEONEX and corresponding MODIS LSRs. In particular, the RMSEs between GEONEX and MOD09 data are comparable to those between MOD09 and MODIS MAIAC products, suggesting that the uncertainties of GEONEX LSRs fall into an acceptable range. However, direct comparisons of LSRs over pixels with different sun-view angles are not as straightforward and require more modeling efforts to correct the directional effects. Evaluation of such angular influences on the downstream products (e.g., vegetation indices) is also under investigation.

Geostationary satellite; Remote Sensing; Atmospher↗

MODIS Reflective Solar Band Calibration Improvements using Pseudo-Invariant Desert Targets

To provide the best science data quality, an accurate characterization of the response versus scan angle (RVS) function is critical for the MODIS reflective solar bands (RSB) on-orbit calibration. In every MODIS operational scan, the Earth’s surface, referred to here as Earth view (EV), the space view (SV) port, and the onboard calibrators are viewed via a two-sided scan mirror. The RVS is defined as the sensor’s relative response as a function the angle of incidence (AOI) to the scan mirror. Many different approaches have been developed to derive the time-dependent RVS and its look-up table (LUT) applied to MODIS Level 1B (L1B) products since calibration Collection 4. For most MODIS RSB, the on-board calibrators can reasonably track the RVS change with time. In practice, their RVS is derived using data from on-board calibrators and the EV mirror side ratio (for mirror side 2). For Terra bands 1-4, 8-10 and Aqua bands 1-4, 8-9, an enhancement has been employed in Collections 6 and 6.1 (C6/C6.1) by using Earth scene response trending from pseudo-invariant desert sites in addition to the onboard calibrators. The current C6/C6/1 RVS algorithm is focused on fitting the EV data at each AOI over time and then deriving the relative change at different AOI. The EV response trending is currently fitted with multiple segments over time. Alternatively, the EV responses can be fit first as a function of AOI before fitting temporally in order to reduce the dependence on the stability of the desert site. These pre-treatment methods on the EV data provide improvement in the derived calibration coefficients. However, evidence of insufficient calibration is still observed in the MODIS L1B reflectance data, especially in the form of differences between the mirror sides. In this paper, we review the current methodologies that utilize the EV response trends from the pseudo-invariant Libyan desert targets to supplement the gain derived from the onboard calibrators. An improvement is then proposed and investigated such that a sliding window average (SWA) is used to pre-process the raw EV data. The SWA parameters are carefully selected using trade-off studies to accurately track the Earth scene response trending in multiple cases to overcome the reflectance differences between two mirror sides. Calibration results show improvements for both Aqua and Terra MODIS RSB L1B data products. This new adjustment has been included in the recently delivered Collection 7 LUT that will be evident in the L1B products expected to be released in late 2021.

MODIS↗

Improvements of On-orbit Characterization of Terra MODIS Short-wave Infrared Spectral Bands Out-of-Band Responses

The short-wave infrared (SWIR) bands (5-7, 26) of Terra MODIS, which are co-located with the mid-wav e infrared (MWIR) bands (20-25) on the short and mid-wave infrared (SMIR) Focal Plane Assembly (FPA),have a known issue related to 5.3 μm out-of-band (OOB) thermal leak and electronic crosstalk that was identified prelaunch. As a result, a crosstalk correction algorithm was designed and implemented in the MODIS Level 1B (L1B) calibration. Shortly after the Terra launch, extensive efforts were under taken to help characterize and mitigate the impact due to the OOB response and crosstalk on the SWIR on-orbit calibration and, consequently, the associated L1Bdata products. In addition, special night time day mode (NTDM) operations have been regularly scheduled to derive the crosstalk correction coefficients. Since MODIS does not have a spectral band centered at 5.3 μm, its band 28 (7.325 μm) was chosen as the surrogate sending band to simulate the OOB radiances at 5.3 μm. This was largely based on the measurements from the MODIS Airborne Simulator (MAS) spectrometer field campaigns in the early months after the Terra launch. In the case of Aqua MODIS, the magnitude of the SWIR crosstalk was much smaller and band 25 (4.52 μm) was found to be more effective as the sending band for the crosstalk correction. In recent years, the Terra MODIS photovoltaic (PV) long-wave infrared (LWIR) bands (27-30)electronic crosstalk has increased considerably, especially after the spacecraft safe-mode event occurred in February2016. This accentuated degradation in the PV LWIR performance has also impacted the performance of the SWIR crosstalk correction and thus its calibration and data quality. In this paper, we examine the use of band 25 as the sending band for the Terra MODIS SWIR crosstalk correction and compare its performance with that based on band 28 as the sending band. Results indicate an improvement of on-orbit gain stability for the SWIR calibration and reduced detector to detector and sub-frame to sub-frame striping in the calibrated L1B imagery, especially during the period when the PV LWIR electronic crosstalk has become more severe. This approach has been implemented in the forward production of Terra MODIS Collection 6 and Collection 6.1,starting from July 2019, and is planned to be used for the future reprocessing of MODIS L1B and to help improve the mission-long reflectance calibration and trending stability of the SWIR bands.

MODIS, Terra, Aqua, MODIS, SWIR, calibration, out-↗

Additional characterization of Libya-4 in support of post-launch vicarious calibration of satellite imagers

Libya-4 (28.55° N and 23.39° E) is one of the most characterized and utilized Pseudo Invariant Calibration Site (PICS) for post-launch radiometer drift monitoring and sensor pair radiometric scaling. Libya-4 is one of the driest and most reflective PICS located in an extensive sand dune region void of any vegetation with an elevation of 118 m. It is positioned near the northeast border with Egypt. With minimal cloud cover and the monthly mean precipitation of ~ 1mm, Libya-4 is one of the temporally, spectrally, and spatially stable CEOS recommended PICS and Cosnefroy et al. 1996 identified sites. The Libya-4 PICS has been extensively used for post-launch radiometric calibration and validation of high-, medium, and low-resolution satellite imagers, including Landsat, MODIS, VIIRS, and Meteosats. The CERES Imager and Geostationary Calibration Group (IGCG) at NASA LaRC utilizes Libya-4 to perform an independent assessment of the radiometric stability of the MODIS and VIIRS L1B products. The site is also used for absolute radiometric scaling between MODIS, VIIRS, and geostationary imagers to ensure consistent cloud and radiative flux retrievals. Multi-year Terra-MODIS, Aqua-MODIS , NPP-VIIRS and Metoesat-7 observations over Libya-4 show very similar TOA reflectance temporal variability. Although, the surface reflectance and atmospheric column varies seasonally, the inter-annual variability of the seasonal cycle should be small. Especially during 2013, the Libya-4 TOA reflectance was found to be greater than usual in all 4 satellite records. Preliminary comparisons with mean wind speed and aerosol optical depth (AOD) indicate that the year 2013 is marked by elevated levels of both conditions. The goal of this study is to tie the Libya-4 visible reflectance inter-annual variability with corresponding meteorological measurements to further improve the characterization of the site.

David R. Doelling↗

Impact of Satellite Orbit Drift on Modis Earth Scene Observations Used in Calibration of the Reflective Solar Bands

After more than 20 years in orbit, NASA’s Terra and Aqua satellites have both started drifting away from their historically maintained orbits. The MODIS instruments on Terra and Aqua continue to collect valuable Earth observation data, but the changing orbits present a challenge for maintaining accurate calibration. The MODIS reflective solar bands (RSB), spanning the wavelength range from 412 nm to 2130 nm, are calibrated on orbit using a combination of regular data collections from an on-board solar diffuser, the Moon, and pseudo-invariant Earth scenes. Starting in the Collection 6 Level 1B (L1B) data products, the RSB calibration began using data from desert targets for a few of the visible bands to better track changes in the response versus scan angle that could not be captured by the on-board calibration. The use of Earth scene data has been extended recently for Terra MODIS calibration in Collection 6.1 (C6.1) and the upcoming Collection 7 (C7) L1B to also include data from ocean scenes and deep convective clouds (DCC). Drifts in both the orbit inclination and ground track of Terra and Aqua lead to changes in the solar illumination angles and satellite view angles of the Earth scenes. We discuss how these orbital changes impact the desert and DCC targets used for MODIS RSB calibration and present the accompanying changes made to our C6.1 and C7 calibration algorithms. We also discuss remaining future challenges, such as better characterization of bi-directional reflectance distribution functions, and possible alternative calibration strategies.

MODIS↗

MODIS Reflective Solar Bands On-Orbit Calibration and Performance

The design of the MODIS instrument was driven by the scientific community's desire to have near-daily global coverage at moderate resolution (1 km) with a comprehensive spectral coverage from visible to long-wave infrared wavelengths. Since their launches in 1999 and 2002, respectively, the Terra and Aqua MODIS instruments have made continuous global observations and generated numerous data products to help users worldwide with their studies of the Earth's system and its short- and long-term changes. The 20 reflective solar bands (RSB) with wavelengths from 0.41 to 2.2 m collect data at three nadir spatial resolutions: 250 m, 500 m, and 1 km. The solar diffuser (SD) coupled with the solar diffuser stability monitor (SDSM) provide a reflectance-based calibration on-orbit. In addition, lunar observations and response trends from pseudo-invariant desert sites are used to characterize the response versus scan- angle changes on-orbit. This paper provides a brief overview of MODIS RSB calibration algorithms, as implemented in the latest Level 1B version 6.1, operational activities, on-orbit performance, remaining challenges and potential improvements. Results from the SD and SDSM measurements show a wavelength and mirror side dependent degradation in RSB responses, with the largest degradation at the shortest wavelengths, particularly for Terra MODIS. Aqua MODIS has experienced far less degradation of its optics and on-board calibrators compared to Terra MODIS, resulting in an overall better performance. With the exception of Aqua band 6, there have been no new noisy or inoperable detectors in the RSB of either instrument during post-launch operations. As the instruments age and continue to endure the space environment, the detectors and optical systems degrade. The challenges associated with incorporating these on-orbit changes to ensure a production of high-quality calibrated L1B data products are also discussed in this paper.

solar diffuser stability monitor↗

On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar Bands

Aqua MODIS has successfully operated on-orbit for more than 6 years since its launch in May 2002, continuously making global observations and improving studies of changes in the Earth's climate and environment. 20 of the 36 MODIS spectral bands, covering wavelengths from 0.41 to 2.2 microns, are the reflective solar bands (RSB). They are calibrated on-orbit using an on-board solar diffuser (SD) and a solar diffuser stability monitor (SDSM). In addition, regularly scheduled lunar observations are made to track the RSB calibration stability. This paper presents Aqua MODIS RSB on-orbit calibration and characterization activities, methodologies, and performance. Included in this study are characterizations of detector signal-to-noise ratio (SNR), short-term stability, and long-term response change. Spectral wavelength dependent degradation of the SD bidirectional reflectance factor (BRF) and scan mirror reflectance, which also varies with angle of incidence (AOI), are examined. On-orbit results show that Aqua MODIS onboard calibrators have performed well, enabling accurate calibration coefficients to be derived and updated for the Level 1B (L1B) production and assuring high quality science data products to be continuously generated and distributed. Since launch, the short-term response, on a scan-by-scan basis, has remained extremely stable for most RSB detectors. With the exception of band 6, there have been no new RSB noisy or inoperable detectors. Like its predecessor, Terra MODIS, launched in December 1999, the Aqua MODIS visible (VIS) spectral bands have experienced relatively large changes, with an annual response decrease (mirror side 1) of 3.6% for band 8 at 0.412 microns, 2.3% for band 9 at 0.443 microns, 1.6% for band 3 at 0.469 microns, and 1.2% for band 10 at 0.488 microns. For other RSB bands with wavelengths greater than 0.5 microns, the annual response changes are typically less than 0.5%. In general, Aqua MODIS optics degradation is smaller than Terra MODIS and the mirror side differences are much smaller. Overall, Aqua MODIS RSB on-orbit performance is better than Terra MODIS.

Xiong, Xiaoxiong↗

Assessment of MODIS On-Orbit Calibration Using a Deep Convective Cloud Technique

The MODerate Resolution Imaging Spectroradiometer (MODIS) sensors onboard Terra and Aqua satellites are calibrated on-orbit with a solar diffuser (SD) for the reflective solar bands (RSB). The MODIS sensors are operating beyond their designed lifetime and hence present a major challenge to maintain the calibration accuracy. The degradation of the onboard SD is tracked by a solar diffuser stability monitor (SDSM) over a wavelength range from 0.41 to 0.94 micrometers. Therefore, any degradation of the SD beyond 0.94 micrometers cannot be captured by the SDSM. The uncharacterized degradation at wavelengths beyond this limit could adversely affect the Level 1B (L1B) product. To reduce the calibration uncertainties caused by the SD degradation, invariant Earth-scene targets are used to monitor and calibrate the MODIS L1B product. The use of deep convective clouds (DCCs) is one such method and particularly significant for the short-wave infrared (SWIR) bands in assessing their long-term calibration stability. In this study, we use the DCC technique to assess the performance of the Terra and Aqua MODIS Collection-6 L1B for RSB 1 3- 7, and 26, with spectral coverage from 0.47 to 2.13 micrometers. Results show relatively stable trends in Terra and Aqua MODIS reflectance for most bands. Careful attention needs to be paid to Aqua band 1, Terra bands 3 and 26 as their trends are larger than 1% during the study time period. We check the feasibility of using the DCC technique to assess the stability in MODIS bands 17-19. The assessment test on response versus scan angle (RVS) calibration shows substantial trend difference for Aqua band 1between different angles of incidence (AOIs). The DCC technique can be used to improve the RVS calibration in the future.

Mu, Qiaozhen↗

Scientific Impact of MODIS C5 Calibration Degradation and C6+ Improvements

The Collection 6 (C6) MODIS (Moderate Resolution Imaging Spectroradiometer) land and atmosphere data sets are scheduled for release in 2014. C6 contains significant revisions of the calibration approach to account for sensor aging. This analysis documents the presence of systematic temporal trends in the visible and near-infrared (500 m) bands of the Collection 5 (C5) MODIS Terra and, to lesser extent, in MODIS Aqua geophysical data sets. Sensor degradation is largest in the blue band (B3) of the MODIS sensor on Terra and decreases with wavelength. Calibration degradation causes negative global trends in multiple MODIS C5 products including the dark target algorithm's aerosol optical depth over land and Ångstrom exponent over the ocean, global liquid water and ice cloud optical thickness, as well as surface reflectance and vegetation indices, including the normalized difference vegetation index (NDVI) and enhanced vegetation index (EVI). As the C5 production will be maintained for another year in parallel with C6, one objective of this paper is to raise awareness of the calibration-related trends for the broad MODIS user community. The new C6 calibration approach removes major calibrations trends in the Level 1B (L1B) data. This paper also introduces an enhanced C6C calibration of the MODIS data set which includes an additional polarization correction (PC) to compensate for the increased polarization sensitivity of MODIS Terra since about 2007, as well as detrending and Terra- Aqua cross-calibration over quasi-stable desert calibration sites. The PC algorithm, developed by the MODIS ocean biology processing group (OBPG), removes residual scan angle, mirror side and seasonal biases from aerosol and surface reflectance (SR) records along with spectral distortions of SR. Using the multiangle implementation of atmospheric correction (MAIAC) algorithm over deserts, we have also developed a detrending and cross-calibration method which removes residual decadal trends on the order of several tenths of 1% of the top-of-atmosphere (TOA) reflectance in the visible and near-infrared MODIS bands B1-B4, and provides a good consistency between the two MODIS sensors. MAIAC analysis over the southern USA shows that the C6C approach removed an additional negative decadal trend of Terra (Delta)NDVI approx.0.01 as compared to Aqua data. This change is particularly important for analysis of vegetation dynamics and trends in the tropics, e.g., Amazon rainforest, where the morning orbit of Terra provides considerably more cloud-free observations compared to the afternoon Aqua measurements.

Terra and Aqua↗

Generating Accurate and Consistent Top-Of-Atmosphere Reflectance Products from the New Generation Geostationary Satellite Sensors

GeoNEX is a collaborative project by scientists from NASA, NOAA, JAXA, and other organizations around the world with the purpose of generating a suite of Earth-monitoring products using data streams from the latest geostationary (GEO) sensors including the GOES-16/17 ABI and the Himawari-8/9 AHI. An accurate and consistent top-of-atmosphere (TOA) reflectance product, in particular the bidirectional reflectance factor (BRF), is the starting point in the scientific processing chain. We describe the main considerations and corresponding algorithms in generating the GeoNEX TOA BRF product. First, a special advantage of geostationary data streams is their high temporal resolution (~10 minutes per full-disk scan), providing a key source of information for many downstream products. To fully utilize this high temporal frequency demands a high georegistration accuracy for every acquired image. Our analysis shows that there can be substantial georegistration uncertainties in both GOES and Himawari L1b data which we addressed by implementing a phase-based correction algorithm to remove residual errors. Second, geostationary sensors have distinct illumination-view geometry features in that the solar angle changes for every pixel. Therefore, to accurately derive a BRF requires a solar position algorithm and the estimation of the pixel-wise acquisition time within an uncertainty of 10 seconds. Third, we discuss the measures we adopted to check and correct residual radiometric calibration issues of individual sensors to enable time-series analysis as well as the cross calibration between different satellite sensors (including those from low-Earth orbit). Finally, we also explain the rationale for the choice of the global grid/tile system of the GeoNEX TOA BRF product.

Wang, Weile↗

Characterization of MODIS VIS/NIR Spectral Band Detector-to-Detector Difference

MODIS has 36 spectral bands with wavelengths in the visible (VIS), near-infrared (NIR), shortwave infrared (SWTR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). It makes observations at three nadir spatial resolutions: 0,25km for bands 1-2 with 40 detectors per band, 0.5km for bands 3-7 with 20 detectors per band, and 1km for bands 8-36 with 10 detectors per band. The VIS, NIR, and S\VIR spectral bands are the reflective solar bands (RSB), which are calibrated on-orbit by a solar diffuser (SD). In addition, MODIS lunar observations are used to track the RSB calibration stability. In this study, we examine detector-to-detector calibration difference for the VIStNIR spectral bands using the SD and lunar observations. The results will be compared with an independent analysis with additional information, such as polarization correction, derived from standard ocean color data products. The current MODIS RSB calibration approach only carries a band-averaged RVS (response versus scan angle) correction. The results from this study suggest that a detector-based RVS correction should be used to improve the L1B data quality, especially for several VIS bands in Terra MODIS due to large changes of the scan mirror's optical properties in recent years.

Xiong, X.↗

Radiometric Assessment of the First Three Years of the NOAA-20 VIIRS Reflective Solar Bands Calibration

NASA’s Clouds and the Earth’s Radiant Energy System (CERES) SYN1deg Ed4.1 product utilizes geostationary (GEO) satellite measured radiances and retrieved cloud properties to account for the regional diurnal fluctuations in the Earth’s radiant broadband fluxes for times between the CERES measurements gathered from the Aqua (1:30 PM) and Terra (10:30 AM) sun-synchronous satellites. In CERES Edition 4 products, a global uniformity in the cloud properties and computed surface fluxes across the GEO satellite domains is maintained by scaling the radiance observations from more than twenty GEO visible imagers in the CERES record to a common radiometric reference scale, i.e., Aqua-MODIS. With the new-generation GEO (Himawari-8/9 and GOES-16/17) imagers having multiple reflective solar bands (RSB) that are spectrally similar to those of VIIRS, the CERES Imager and Geostationary Calibration Group (IGCG) is preparing to use NOAA-20 VIIRS as the reference imager for maintaining the radiometric uniformity across the GEO imager constellation. Given the recent Aqua satellite anomaly, this transition may happen sooner than the projected date of Aqua’s de-orbit. This paper presents an independent performance evaluation of the first three years of the NOAA-20 VIIRS RSB calibration in the NASA VIIRS Land Science Investigator-led Processing System (Land SIPS) L1b Collection 2 dataset. The temporal radiometric stability is assessed using multiple invariant Earth targets, including tropical deep convective clouds and the Saharan desert. The invariant target anisotropic reflectance at the top of atmosphere was modeled using five years of stable satellite observations acquired from the previous VIIRS instrument onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. The anisotropic corrections are essential for detecting temporal trends with a high statistical confidence. In addition, the radiometric consistency between the RSB of the two VIIRS instruments will be evaluated.

Rajendra Bhatt↗

Radiometric Assessment of the First Three Years of the NOAA-20 VIIRS Reflective Solar Bands Calibration

NASA’s Clouds and the Earth’s Radiant Energy System (CERES) SYN1deg Ed4.1 product utilizes geostationary (GEO) satellite measured radiances and retrieved cloud properties to account for the regional diurnal fluctuations in the Earth’s radiant broadband fluxes for times between the CERES measurements gathered from the Aqua (1:30 PM) and Terra (10:30 AM) sun-synchronous satellites. In CERES Edition 4 products, a global uniformity in the cloud properties and computed surface fluxes across the GEO satellite domains is maintained by scaling the radiance observations from more than twenty GEO visible imagers in the CERES record to a common radiometric reference scale, i.e., Aqua-MODIS. With the new-generation GEO (Himawari-8/9 and GOES-16/17) imagers having multiple reflective solar bands (RSB) that are spectrally similar to those of VIIRS, the CERES Imager and Geostationary Calibration Group (IGCG) is preparing to use NOAA-20 VIIRS as the reference imager for maintaining the radiometric uniformity across the GEO imager constellation. Given the recent Aqua satellite anomaly, this transition may happen sooner than the projected date of Aqua’s de-orbit. This paper presents an independent performance evaluation of the first three years of the NOAA-20 VIIRS RSB calibration in the NASA VIIRS Land Science Investigator-led Processing System (Land SIPS) L1b Collection 2 dataset. The temporal radiometric stability is assessed using multiple invariant Earth targets, including tropical deep convective clouds and the Saharan desert. The invariant target anisotropic reflectance at the top of the atmosphere was modeled using five years of stable satellite observations acquired from the previous VIIRS instrument onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. The anisotropic corrections are essential for detecting temporal trends with high statistical confidence. In addition, the radiometric consistency between the RSB of the two VIIRS instruments will be evaluated.

Rajendra Bhatt↗

Status of Aqua MODIS On-orbit Calibration and Characterization

The MODIS Flight Model 1 (FM1) has been in operation for more than two years since its launch onboard the NASA's Earth Observing System (EOS) Aqua spacecraft on May 4, 2002. The MODIS has 36 spectral bands: 20 reflective solar bands (RSB) with center wavelengths from 0.41 to 2.2 micron and 16 thermal emissive bands (TEB) from 3.7 to 14.5 micron. It provides the science community observations (data products) of the Earth's land, oceans, and atmosphere for a board range of applications. Its primary on-orbit calibration and characterization activities are performed using a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) system for the RSB and a blackbody for the TEB. Another on-board calibrator (OBC) known as the spectro-radiometric calibration assembly (SRCA) is used for the instrument's spatial (TEB and RSB) and spectral (RSB only) characterization. We present in this paper the status of Aqua MODIS calibration and characterization during its first two years of on-orbit operation. Discussions will be focused on the calibration activities executed on-orbit in order to maintain and enhance the instrument's performance and the quality of its Level 1B (L1B) data products. We also provide comparisons between Aqua MODIS and Terra MODIS (launched in December, 1999), including their similarity and difference in response trending and optics degradation. Existing data and results show that Aqua MODIS bands 8 (0.412 micron) and 9 (0.443 micron) have much smaller degradation than Terra MODIS bands 8 and 9. The most noticeable feature shown in the RSB trending is that the mirror side differences in Aqua MODIS are extremely small and stable (<0.1%) while the Terra MODIS RSB trending has shown significant mirror side difference and wavelength dependent degradation. The overall stability of the Aqua MODIS TEB is also better than that of the Terra MODIS during their first two years of on-orbit operation.

Aqua↗

Status of Terra MODIS Operation, Calibration, and Performance

Since launch in December 1999, Terra MODIS has successfully operated for nearly 15 years, making continuous observations. Data products derived from MODIS observations have significantly contributed to a wide range of studies of key geophysical parameters of the earth's eco-system of land, ocean, and atmosphere, and their changes over time. The quality of MODIS data products relies on the dedicated effort to monitor and sustain instrument health and operation, to calibrate and update sensor parameters and properties, and to improve calibration algorithms. MODIS observations are made in 36 spectral bands, covering wavelengths from visible to long-wave infrared. The reflective solar bands (1-19 and 26) are primarily calibrated by a solar diffuser (SD) panel and regularly scheduled lunar observations. The thermal emissive bands (20-25 and 27- 36) calibration is referenced to an on-board blackbody (BB) source. On-orbit changes in the sensor spectral and spatial characteristics are monitored by a spectroradiometric calibration assembly (SRCA). This paper provides an overview of Terra MODIS on-orbit operation and calibration activities and implementation strategies. It presents and summarizes sensor on-orbit performance using nearly 15 years of data from its telemetry, on-board calibrators, and lunar observations. Also discussed in this paper are changes in sensor characteristics, corrections applied to maintain MODIS level 1B (L1B) data quality, and efforts for future improvements.

Terra↗

Derivation of Shortwave Radiometric Adjustments for SNPP and NOAA-20 VIIRS for the NASA MODIS-VIIRS Continuity Cloud Products

Climate studies, including trend detection and other time series analyses, necessarily require stable, well-characterized and long-term data records. For satellite-based geophysical retrieval datasets, such data records often involve merging the observational records of multiple similar, though not identical, instruments. The National Aeronautics and Space Administration (NASA)cloud mask(CLDMSK) and cloud-top and optical properties(CLDPROP) products are designed to bridge the observational records of the Moderate-resolution Imaging Spectroradiometer (MODIS) onboard NASA’s Aqua satellite and the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the joint NASA/National Oceanic and Atmospheric Administration(NOAA)Suomi National Polar-orbiting Partnership (SNPP)satellite and NOAA’s new generation of operational polar-orbiting weather platforms(NOAA-20+).Early implementations of the CLDPROP algorithms on Aqua MODIS and SNPP VIIRS suffered from large intersensor biases in cloud optical properties that were traced back to relative radiometric inconsistency in analogous shortwave channels on both imagers, with VIIRS generally observing brighter top-of-atmosphere spectral reflectance than MODIS (e.g., up to 5%brighter in the 0.67μm channel). Radiometric adjustment factors for the SNPP and NOAA-20 VIIRS shortwave channels used in the cloud optical property retrievals are derived from an extensive analysis of the overlapping observational records with Aqua MODIS, specifically for homogenous maritime liquid water cloud scenes for which the viewing/solar geometry of MODIS and VIIRS match. Application of these adjustment factors to the VIIRS L1B prior to ingestion into the CLDMSK and CLDPROP algorithms yields improved intersensor agreement, particularly for cloud optical properties

relative radiometry↗

Atmospheric Correction at AERONET Locations: A New Science and Validation Data Set

This paper describes an AERONET-based Surface Reflectance Validation Network (ASRVN) and its dataset of spectral surface bidirectional reflectance and albedo based on MODIS TERRA and AQUA data. The ASRVN is an operational data collection and processing system. It receives 50x50 square kilometer subsets of MODIS L1B data from MODAPS and AERONET aerosol and water vapor information. Then it performs an accurate atmospheric correction for about 100 AERONET sites based on accurate radiative transfer theory with high quality control of the input data. The ASRVN processing software consists of L1B data gridding algorithm, a new cloud mask algorithm based on a time series analysis, and an atmospheric correction algorithm. The atmospheric correction is achieved by fitting the MODIS top of atmosphere measurements, accumulated for 16-day interval, with theoretical reflectance parameterized in terms of coefficients of the LSRT BRF model. The ASRVN takes several steps to ensure high quality of results: 1) cloud mask algorithm filters opaque clouds; 2) an aerosol filter has been developed to filter residual semi-transparent and sub-pixel clouds, as well as cases with high inhomogeneity of aerosols in the processing area; 3) imposing requirement of consistency of the new solution with previously retrieved BRF and albedo; 4) rapid adjustment of the 16-day retrieval to the surface changes using the last day of measurements; and 5) development of seasonal back-up spectral BRF database to increase data coverage. The ASRVN provides a gapless or near-gapless coverage for the processing area. The gaps, caused by clouds, are filled most naturally with the latest solution for a given pixels. The ASRVN products include three parameters of LSRT model (k(sup L), k(sup G), k(sup V)), surface albedo, NBRF (a normalized BRF computed for a standard viewing geometry, VZA=0 deg., SZA=45 deg.), and IBRF (instantaneous, or one angle, BRF value derived from the last day of MODIS measurement for specific viewing geometry) for MODIS 500m bands 1-7. The results are produced daily at resolution of 1 km in gridded format. We also provide cloud mask, quality flag and a browse bitmap image. The new dataset can be used for a wide range of applications including validation analysis and science research.

Wang, Yujie↗

Impact of MODIS SWIR Band Calibration Improvements on Level-3 Atmospheric Products

The spectral reflectance measured by the MODIS reflective solar bands (RSB) is used for retrieving many atmospheric science products. The accuracy of these products depends on the accuracy of the calibration of the RSB. To this end, the RSB of the MODIS instruments are primarily calibrated on-orbit using regular solar diffuser (SD) observations. For lambda < 0.94 microns the SDs on-orbit bi-directional reflectance factor (BRF) change is tracked using solar diffuser stability monitor (SDSM) observations. For lambda > 0.94 microns, the MODIS Characterization Support Team (MCST) developed, in MODIS Collection 6 (C6), a time-dependent correction using observations from pseudo-invariant earth-scene targets. This correction has been implemented in C6 for the Terra MODIS 1.24 micron band over the entire mission, and for the 1.375 micron band in the forward processing. As the instruments continue to operate beyond their design lifetime of six years, a similar correction is planned for other short-wave infrared (SWIR) bands as well. MODIS SWIR bands are used in deriving atmosphere products, including aerosol optical thickness, atmospheric total column water vapor, cloud fraction and cloud optical depth. The SD degradation correction in Terra bands 5 and 26 impact the spectral radiance and therefore the retrieval of these atmosphere products. Here, we describe the corrections to Bands 5 (1.24 microns) and 26 (1.375 microns), and produce three sets (B5, B26 correction on/on, on/off, and off/off) of Terra-MODIS Level 1B (calibrated radiance product) data. By comparing products derived from these corrected and uncorrected Terra MODIS Level 1B (L1B) calibrations, dozens of L3 atmosphere products are surveyed for changes caused by the corrections, and representative results are presented. Aerosol and water vapor products show only small local changes, while some cloud products can change locally by > 10%, which is a large change.

Calibration↗