Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Kr”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Strength, deformation, and the fcc–hcp phase transition in condensed Kr and Xe to the 100 GPa pressure range

The rare gas solids exhibit systematic differences in crystal structure, phase transition conditions, bond strength, and other physical properties. The physical properties of heavy rare gas solids krypton and xenon are modified by the martensitic phase transition from face-centered cubic to hexagonal close packed structure over a broad pressure range. Crystal structure, strength, and plastic deformation of krypton and xenon have been investigated at 300 K using compression in the diamond-anvil cell with synchrotron angle-dispersive x-ray diffraction and complementary ruby fluorescence spectroscopy for Xe. Stacking faults indicative of the fcc–hcp phase transition are observed at pressures at and above 1.23 ± 0.05 and 1.9 ± 0.6 GPa in Kr and Xe, respectively. The transition remains incomplete in both solids to pressures greater than 100 GPa. Strength determined from stress measurements in Pt and ruby standards at pressures up to 111 GPa and complemented by observations of strain and texture measurements obtained by x-ray diffraction in the radial geometry to 100 GPa indicates similar or higher strength than Ar at all conditions, with significant stiffening at 15–20 GPa. Radial diffraction data reveal the persistence of broad highly textured fcc diffraction lines to 101 GPa in Xe, suggesting that the axial measurements may underestimate the metastable persistence of the fcc phase due to biased sampling of hcp crystallites resulting from preferred crystallite orientation. Kr and Xe are compared with He, Ne, and Ar for a systematic understanding of physical properties and phase equilibria of rare gas solids.

Compressive stress↗

Establishing the ground-state spin of 71 Kr

Nuclei in the vicinity of the N=Z line provide many sensitive probes of isospin symmetry. One example concerns the character and sequence of low-lying states of the T=1/2 mirror pair 71 Kr and 71 Br which has been under debate for several decades. In this paper we report a new measurement of the absolute β-branching to ground and excited states which, taken with our precise lifetime of T 1/2 =94.9(4) ms , gives a superallowed ground state–to–ground state log (ft) value of 3.64(4). This is only consistent with both 71 Br and 71 Kr having the same spin and parity, J π =5/2 – , as expected from mirror symmetry. The β-delayed proton emission to the first-excited state in 70 Se was observed for the first time which also strongly supports this assignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-Center Interference in the Photoionization Delays of Kr 2

Herein we present the experimental observation of two-center interference in the ionization time delays of Kr 2 . Using attosecond electron-ion-coincidence spectroscopy, we simultaneously measure the photoionization delays of krypton monomer and dimer. The relative time delay is found to oscillate as a function of the electron kinetic energy, an effect that is traced back to constructive and destructive interference of the photoelectron wave packets that are emitted or scattered from the two atomic centers. Our interpretation of the experimental results is supported by solving the time-independent Schrödinger equation of a 1D double-well potential, as well as coupled-channel multiconfigurational quantum-scattering calculations of Kr 2 . This work opens the door to the study of a broad class of quantum-interference effects in photoionization delays and demonstrates the potential of attosecond coincidence spectroscopy for studying weakly bound systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $ ^{136}\mathrm Xe$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83\text {m}}\textrm{Kr}$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83\text {m}}\textrm{Kr}$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta \beta }$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

Martínez-Lema, G. [Donostia Intl. Phys. Ctr., San ↗

Signal-to-background estimates for the inverse-kinematics 78 Kr(n,γ) experiment at LANSCE

The idea of a neutron target enables the measurement of neutron-induced reactions in inverse kinematics. This idea is part of the LANSCE strategy to stay a worldwide leader for neutron-induced research. The proof-of-principle experiment outlined in is the core of the LDRD project 20240004DR. The current approach is to use an ion source capable of accelerating single-charged ions up to about 60 keV. A beam of 78 Kr + ions will be created to interact with a neutron target and implanted. During the passage of the target, neutrons can be captured and the freshly produced 79 Kr + ions will be implanted along with the main beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-situ TEM study of Kr ion irradiation tolerance of SiFeOC nanocomposite

Here, in this work, ion irradiation of polymer derived SiFeOC nanocomposite was carried out using 1.2 MeV Kr ions at room temperature and 600°C. The starting composite was composed of Fe 3 Si, SiC, SiOC, SiO 2 , and graphitic C. In-situ TEM investigations show uniform distribution of nano-crystalline Fe 3 Si and SiC phases in the amorphous SiOC matrix. During ion irradiation, the SiOC bulk microstructure and interfaces between Fe 3 Si or SiC crystallites and the SiOC matrix remain defect-free and demonstrate outstanding ion irradiation resistance. At room temperature, the crystalline domains are stable up to 2 dpa. At 600°C, Fe 3 Si crystallites are more stable than SiC; SiC crystallites are stable up to 4 dpa while the Fe 3 Si crystallites are stable up to 10 dpa. These crystallites also coalescence and amorphize simultaneously during ion irradiation. The exceptional tolerance to defect formation and irradiation of the SiFeOC nanocomposite provides important guidance to developing irradiation resistant fuels for advanced gas cooled reactors.

36 MATERIALS SCIENCE↗

Observation and diagnostic application of Kr K-shell emission in magnetized liner inertial fusion experiments at Z

In a series of Magnetized Liner Inertial Fusion (MagLIF) experiments performed at the Z pulsed power accelerator of Sandia National Laboratories, beryllium liners filled with deuterium gas pressures in the 4–8 atm range and a tracer amount of krypton were imploded. At the collapse of the cylindrical implosion, temperatures in the 1–3 keV range and atom number densities of ∼1023 cm−3 were expected. The plasma was magnetized with a 10 T axial magnetic field. Krypton was added to the fuel for diagnosing implosion plasma conditions. Krypton K-shell line emission was recorded with the CRITR time-integrated transmission crystal x-ray spectrometer. The observation shows n = 2 to n = 1 line emissions in B-, Be-, Li-, and He-like Kr ions and is characteristic of the highest electron temperatures achieved in the thermonuclear plasma. Detailed modeling of the krypton atomic kinetics and radiation physics permits us to interpret the composite spectral feature, and it demonstrates that the spectrum is temperature sensitive. We discuss temperatures extracted from the krypton data analysis for experiments performed with several filling pressures.

Clapp, J. T. (ORCID:0000000219928146)↗

Project 8 apparatus for cyclotron radiation emission spectroscopy with 83m Kr and tritium

Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project 8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection of the CRES signal from the conversion electrons of 83m Kr and the first CRES measurement of the beta-decay spectrum of molecular tritium.

Neutrino detectors↗

Cyclotron radiation emission spectroscopy of electrons from tritium $β$ decay and 83m Kr internal conversion

Project 8 has developed a novel technique, cyclotron radiation emission spectroscopy (CRES), for direct neutrino mass measurements. A CRES-based experiment on the beta spectrum of tritium has been carried out in a small-volume apparatus. Here, we provide a detailed account of the experiment, focusing on systematic effects and analysis techniques. In a Bayesian (frequentist) analysis, we measure the tritium endpoint as ${18}$ ${553}_{—19}^{+18}$ (${18}$ ${548}_{—19}^{+19}$) eV and set upper limits of 155 (152) eV (90% C.L.) on the neutrino mass. No background events are observed beyond the endpoint in 82 days of running. We also demonstrate an energy resolution of 1.66 ± 0.19 eV in a resolution-optimized magnetic trap configuration by measuring 83m Kr 17.8-keV internal-conversion electrons. These measurements establish CRES as a low-background, high-resolution technique with the potential to advance neutrino mass sensitivity

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the inhomogeneity of the KATRIN tritium source electric potential by high-resolution spectroscopy of conversion electrons from $\mathbf {^{83m}}$Kr

Precision spectroscopy of the electron spectrum of the tritium β-decay near the kinematic endpoint is a direct method to determine the effective electron antineutrino mass. The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to determine this quantity with a sensitivity of better than 0.3 eV (90% C.L.). An inhomogeneous electric potential in the tritium source of KATRIN can lead to distortions of the β-spectrum, which directly impact the neutrino-mass observable. This effect can be quantified through precision spectroscopy of the conversion-electrons of co-circulated metastable 83m Kr. Therefore, dedicated, several-weeks long measurement campaigns have been performed within the KATRIN data taking schedule. In this work, we infer the tritium source potential observables from these measurements, and present their implications for the neutrino-mass determination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MRWFD Kr Capture Project

Progress report presentation to DOE program representatives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Krypton Concentration using HZ-PAN

Idaho National Laboratory (INL) has developed and tested engineered sorbents to separate and capture volatile fission products such iodine, xenon (Xe), and krypton (Kr) from off-gas streams. As noble gases, Xe and Kr can be difficult to capture and separate. Historically, cryogenic distillation has been used to execute the separation. However, performing this separation from bulk air streams is expensive and can pose significant hazards. INL has successfully developed two different sorbents for Xe and Kr capture, silver mordenite polyacrylonitrile and hydrogen mordenite polyacrylonitrile (HZ-PAN). Adsorption studies to date successfully separated and captured Kr from carrier gas streams, but those studies focused primarily on initial separation and capture. Successful utilization in a used nuclear fuel (UNF) reprocessing facility, however, requires further concentration of the Kr to minimize long term storage volumes. This study focuses on the concentration of Kr utilizing HZ PAN as the concentrating media. Concentrating Kr during desorption is ideal for two reasons: one, to produce Kr that can be used for commercial and research applications, or two, to minimize the volume of the radioactive gaseous waste stream for disposal. This report investigates the Kr concentrating potential of HZ-PAN by running multiple Kr adsorption-desorption cycles, collecting the desorbed effluent from a saturated HZ-PAN column, and loading it onto a fresh column. This study demonstrates that four adsorption-desorption cycles can transform a 150 ppmv Kr stream into a 37.5% Kr stream, an overall concentration factor of 2497. Each concentration step results in successively smaller volumes desorbed, reducing volume by a factor of approximately 40,000. Depending on the operational goals, during desorption one could collect smaller volume fractions of high concentration Kr (~ 67%). This demonstration should be considered proof-of-concept. Further refinement is necessary to develop optimum operating schemes to integrate into UNF off-gas treatment.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Cost-Benefit Assessment of Krypton and Xenon Recovery from Aqueous Reprocessing

The purpose of this paper is to provide an understanding of the cost-benefit of capturing Kr and Xe from the existing process of aqueous reprocessing of UNF. The study accomplishes this with a market assessment of Xe prices and volumes today, coupled with a cost estimate of Kr and Xe capture out of cryogenic distillation within aqueous reprocessing. The market assessment shows that the average price of Xe is about $\$ $60/L while the average price of Kr is about $\$ $1/L. The assessment also shows that the market structure for Xe is one of oligopoly, in other words, very few suppliers to the Xe market. The assessment shows growing demand for Xe, particularly in medical applications like anesthesia. The cost assessment finds the unit cost of Xe to range from $\$ $71.50/L to $\$ $131.13/L. This range is only slightly above the current range of market prices today, and with growing demand for Xe, prices could reach the range it would take to support extraction of Xe from aqueous reprocessing. On the other hand, the estimated cost range for Kr is $\$ $830.15/L up to $\$ $1,522.52/L, which far exceeds the range of market prices for Kr. However, as the text notes, Kr capture is already part of aqueous reprocessing so these costs are sunk costs (already incurred) whereas the cost estimates for Xe are marginal cost (if Xe is desired, then the cost estimate would result from the Xe capture).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Short-lived noble gas effluent trends from a research reactor

An understanding of anthropogenic sources of radioactive noble gases in the atmosphere is needed to enhance the discrimination ability of the International Monitoring System's sensors. These sources include commercial and research nuclear reactors and medical isotope production facilities. While abiding by local environmental ordinances these facilities all emit noble gas radioisotopes through normal operation. Here, this research presents measurements and analysis of noble gas isotopes ( 41 Ar, 135 Xe, 135m Xe, 137 Xe, 138 Xe, 87 Kr, 88 Kr, and 89 Kr) made directly at the stack of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. The Xe and Kr noble gases are concurrently observed with 41 Ar, a neutron activation product, when the reactor is operational. The magnitude of the Xe and Kr noble gases released is not constant over the HFIR cycle, but they temporally match the 41 Ar trend. An isotope activity ratio analysis of these shorter lived isotopes combined with the observation of the cycle's temporal trend helps understand the noble gas production mechanism at the HFIR. Isotopes with short half-lives are not useful for long-range environmental monitoring. However, these measurements could potentially be combined with atmospheric modeling to predict the background source term of the longer-lived Xe ratios at a monitoring station.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Adsorption Studies of Dilute Krypton and Xenon from Nitrogen on SBMOF-1 and Activated Charcoal for Applications in Isotope Harvesting

Adsorptive partitioning of dilute krypton (Kr) and xenon (Xe) onto Stony Brook Metal–Organic Framework (SBMOF-1) and activated charcoal (AC) from carrier nitrogen was experimentally measured at temperatures ranging from 195 to 293 K. For this purpose, a closed-loop system for gas adsorption experiments was developed. From the Kr adsorption measurements, the adsorption equilibrium constant for Kr on SBMOF-1 was calculated, yielding a value for the enthalpy of adsorption of −19 ± 1 kJ·mol –1 . The partition coefficients were utilized to estimate the extraction rates of 76 Kr, 77 Kr, and 122 Xe isotopes during isotope harvesting at the Facility for Rare Isotope Beams (FRIB). We conclude that both materials showed promising results for the extraction of noble gases from FRIB effluents using temperature swing adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗