Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mineralogical and isotopic constraints on early, high-temperature events and reservoirs recorded in the interior of a Type B Ca-Al-rich inclusion from the reduced CV3 chondrite Vigarano

A coordinated mineralogical and oxygen and Al-Mg isotopic study of a Type B Ca-Al-rich inclusion (CAI) from the reduced CV3 chondrite Vigarano was carried out using electron microprobe analysis, transmission electron microscopy, and secondary ion mass spectrometry. This CAI, a once molten igneous object, shows heterogeneous oxygen isotopic compositions among its constituent mineral phases. Spinel is uniformly 16 O-rich with Δ 17 O ≤ −23 ‰. The Δ 17 O values of Al,Ti-diopside in the CAI core range from −11 ‰ to −18 ‰, which are positively correlated with its TiO 2 contents, whereas diopside in the Wark–Lovering (WL) rim is 16 O-rich with Δ 17 O = −23 ‰. Melilite in the CAI mantle shows Δ 17 O values ≤ −10 ‰ only when Åk <15 but becomes more 16 O-poor (Δ 17 O = −3 ‰ to −9 ‰) when Åk >15 . These correlated chemical and oxygen isotopic variations were likely established during crystallization of melilite and Al,Ti-diopside from a partial melt, while spinel preserves the original 16 O-rich composition of the CAI precursor. We infer that a partial melt was isotopically evolving from 16 O-rich to 16 O-poor during melilite crystallization, then back to 16 O-rich during Al,Ti-diopside crystallization via exchange with different gas reservoirs of 16 O-poor and 16 O-rich compositions during heating event(s). Our Al-Mg isotopic measurements of the CAI core and mantle define a single isochron with an inferred initial 26 Al/ 27 Al ratio of (4.93 ± 0.18) × 10 −5 , indistinguishable from that of the WL rim. This indicates that multiple high-temperature events and oxygen isotope exchange with isotopically distinct gas reservoirs occurred rapidly during the CAI formation.

Al-Mg isotopic systematic

Liquid centrifugation-based isotope separation of 7 Li, 37 Cl and D

Liquid centrifugation is an emerging method to separate isotopes. By spinning a liquid containing target isotopes (e.g., pure chemical or solution), the heavier isotope will be enriched at the outer part of a centrifuge, and the lighter ones will be enriched at the inner part of a centrifuge. The separation capability is positively correlated with rotation speed, outer radius and mass difference between isotopes to separate. This award targets to understand whether liquid centrifugation is effective in separating isotopes important for nuclear fission technologies. The results include the following three sections: 1) Effects of solute concentration on isotope separation; 2) Preliminary progress of building a low-speed countercurrent centrifuge, and 3) Analysis on possible candidates for 7 Li and 37 Cl. The award trained one research scientist, one Ph.D. student, one master student, and one undergraduate on liquid centrifugation and isotope measurements.

07 ISOTOPE AND RADIATION SOURCES

Reassessing the proposed “CY chondrites”: Evidence for multiple meteorite types and parent bodies from Cr-Ti-H-C-N isotopes and bulk elemental compositions

Here, we report a coordinated bulk Cr-Ti-H-C-N isotopic and compositional study of six carbonaceous chondrites from Antarctica that are often considered to be related and termed Yamato-like carbonaceous (CY) chondrites. These meteorites are known to have undergone extensive aqueous alteration followed by different degrees of thermal alteration, to be similar to one another in regard to mineralogy, and share affinities with both the Ivuna-like carbonaceous (CI) and Mighei-like carbonaceous (CM) chondrites. While mineralogically similar, a key difference among these samples is that chondrules have been found in some of these samples, but not in others. The aim of this study is to evaluate the relationship of these meteorites to one another, and investigate how they relate to the CI and CM chondrite groups. We find that with the addition of the isotopic compositions of these ‘CY’ chondrites, there is now a continuum of isotopic compositions among the carbonaceous chondrites. The CI chondrites are no longer separate in O isotopic compositions from the other carbonaceous chondrite groups in plots of Cr-O and Ti-O. We also find that the ‘CY’ chondrites represent two distinct populations, which correlate with their heating stage. However, the peak temperatures experienced by each population can only explain the differences in H and C isotopes and abundances and N abundances between samples, and cannot have caused the differences in N, Cr, and Ti isotopes, or all the volatile element depletions of the sample’s bulk compositions. Instead, we conclude that the compositional and isotopic data of these two populations correlate with their known chondrule abundances, indicating distinct precursors for each population. We find it most likely that these samples originate from two distinct asteroids, implying that among the six samples studied here, there are not five related samples to constitute a new meteorite group. The chondrule-free heating Stage III samples are most likely heated CI chondrites, while the chondrule-bearing heating Stage IV samples could be heated CM chondrites.

58 GEOSCIENCES

A statistical approach to screening isotopic signatures in monitoring for underground nuclear explosions

The ability to differentiate between atmospheric radionuclide signatures from underground nuclear explosions (UNEs) and signals from other sources, such as medical isotope-production facilities and nuclear reactors, can be critical to the detection and monitoring of unannounced, low-yield nuclear events. Signatures having anomalously high amplitudes, compared to background levels, remain the best indicator in screening for a UNE. However, isotopic composition can further validate a suspected UNE signature, but separation from any atmospheric background composition is first necessary. To date, evaluating the challenges of performing this separation has typically involved comparing an observed background with a highly idealized deterministic model of radioxenon signature production by a UNE that does not consider the influence of post-detonation chemical/physical processes in the detonation cavity or the subsequent gas transport mechanisms that can also affect the isotopic composition of the detected gas signature. In addition, purely deterministic models, as previously employed, overlook the uncertainty inherent in estimating critical parameters characterizing the UNE and its detonation environment. In this paper, we create detailed, multi-parameter models of radionuclide evolution using the widely accepted England and Rider post-detonation radionuclide decay-chain network coupled to detailed models simulating physical production and transport processes affecting the gas signature. Because these models are governed by uncertain parameters including barometric fluctuations, realistic ranges of variation for each of the parameters influencing isotopic composition are then defined. A Latin-Hypercube sampling approach is used to obtain a random distribution of isotopic production and gas transport results associated with a given value of each parameter. We apply these results to background histories of two stations, one providing 4-isotope background measurements and the other providing two-isotope measurements associated with the 2013 DPRK announced UNE.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs

Position-Specific Carbon Isotope Fingerprinting of Fluorinated Organics and Degradation Products

Fluorinated organic compounds are of growing environmental and forensic relevance due to their widespread use in pharmaceuticals, agrochemicals, and consumer products, their environmental persistence, and potential ecological and human health impacts. Elucidating their sources and transformation pathways is therefore a major focus of current research. Stable carbon isotope analysis provides a powerful approach for tracing molecular origins and linking parent compounds to degradation products. Recent isotope measurements have largely relied on mass-spectrometry techniques, which provide only an average isotope ratio across a compound. In this work, we employ a novel nuclear magnetic resonance (NMR) spectroscopy tool to determine position-specific carbon isotope ratios ( 13 C/ 12 C) in organofluorine compounds and their degradation products. This approach enables isotope measurements without combustion or extensive purification and, crucially, resolves ratios at individual carbon positions rather than bulk averages. The resulting intramolecular isotope fingerprints are unique to a molecule’s source. Applied to selected pharmaceuticals and pesticides, these fingerprints allow discrimination of chemically identical compounds. Moreover, we show that the 13 C/ 12 C signature at the fluorinated carbon persists through degradation, demonstrated for lansoprazole and fipronil. The 19 F NMR data produced for the 13 C/ 12 C analyses are also well suited for impurity profiling, providing an additional dimension for fingerprinting fluorinated organics. These findings suggest that position-specific isotope analysis can serve as part of a broader suite of tools for source characterization of organofluorine compounds and their breakdown derivatives, with potential applications in product validation, forensics, and linking these compounds to their breakdown products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Non-traditional stable isotope measurements using laser desorption Orbitrap mass spectrometry: Implications for planetary missions.

Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.

58 GEOSCIENCES

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES

Oxygen stable isotopes in the nuclear fuel cycle: Assessment of the potential for determining the fabrication and provenance history of anhydrous and hydrous uranium oxides

Determining the origin and history of interdicted nuclear materials is a central challenge in nuclear forensics. The oxygen stable isotope composition of uranium oxide compounds has emerged as a promising forensic signature, attracting increasing attention since the early 2000s. This review examines analytical techniques for measuring oxygen isotope compositions in uranium oxides and evaluates how the nuclear fuel production cycle introduces or modifies these isotopic signatures. The potential for forensic geolocation is explored through workflows that calibrate the relationship between environmental water oxygen isotopes and those found in uranium oxides. Key strengths and limitations of this approach are assessed, including gaps in knowledge related to isotope fractionation during specific stages of the fuel cycle, and processing facility water inputs. The importance of proper sample handling and storage under inert atmospheres, as well as a deeper understanding of both intra-sample oxygen isotope heterogeneity, and hydrous uranium oxide phase formation, is highlighted for improving the reliability of forensic interpretations. In conclusion, the development of uranium oxide standards with well-characterized δ 18 O values and international collaboration toward consensus on their use are identified as essential steps for advancing the field.

Attribution

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Leaf Wax Hydrogen Isotopes Reflect Storm Track Position Over Western North America

Proxy records of past climates have yielded powerful insights into regional hydroclimate dynamics. Novel insights may be gained by reconstructing spatiotemporal changes in precipitation isotopologues in past climate states that cannot be gleaned from individual site‐level studies. In this paper, we ask whether latitudinal gradients in the stable hydrogen isotopic composition of precipitation, as inferred from sedimentary leaf wax biomarkers, reflect aspects of large‐scale climate conditions in western North America (WNA). Modern coretop samples from offshore WNA show that leaf wax hydrogen isotopes broadly track the hydrogen isotopic composition of rainfall between 20 and 40N, but with an offset corresponding to a relatively constant “apparent fractionation” value. Poleward of 40N, the leaf wax signal may be complicated by fluvial transport of leaf waxes from the continental interior. Leaf wax‐inferred precipitation hydrogen isotopes show a shift to more negative values between 30 and 40N. We use modern observational data to show that this latitudinal range marks a major transition between the subtropical arid zone and the location of the midlatitude storm tracks over the northeast Pacific. Nudged water isotope‐enabled models capture the location of the arid to mesic climate transition with fidelity. This modern data set suggests that reconstructions of the latitudinal gradient of precipitation hydrogen isotopes can constrain the sensitivity of the storm tracks to shifts in climatic boundary conditions in past climate states. This approach can yield novel insights into past, present, and future hydroclimate variability in this arid region.

54 ENVIRONMENTAL SCIENCES

Discovery of new isotopes in the fragmentation of 82 Se and insights into their production

The production cross sections of neutron-rich nuclei for elements just above 60 Ca were measured at the Facility for Rare Isotope Beams (FRIB). Four previously unobserved isotopes ( 63 Sc, 65,66 Ti, and 68 V) were produced, separated, and identified for the first time using the Advanced Rare Isotope Separator (ARIS). One event was found to be consistent with 61 Ca . The new isotopes were created through the interaction of an 82 Se beam with a carbon target at an energy of 228 MeV/𝑢 and a primary beam current of 1.07 p⁢µ⁢A. The event-by-event particle identification of the mass number (𝐴), atomic number (𝑍), and ionic charge state (𝑞) for the reaction products was achieved by combining measurements of energy loss, time of flight, magnetic rigidity, and total kinetic energy. This successful search for new isotopes, conducted at the beginning of FRIB's third year of operation, highlights the facility's discovery potential, which will continue to grow as the beam current increases. The production cross sections were analyzed in the context of the newly developed Δ⁢𝐵⁢𝐸 systematics that provides trends in neutron-rich regions and increased sensitivity to nuclear binding, an important nuclear structure observable. Furthermore, the new systematics addresses gaps in 𝑄 𝑔 -based methods commonly used to interpret the production cross sections of light neutron-rich elements, and provides an efficient empirical approach to describe cross-section trends across isotopic chains. Good agreement with the measured data was obtained when the Δ⁢𝐵⁢𝐸 systematics and abrasion-ablation calculations were performed using the Hartree-Fock-Bogoliubov (HFB-22) mass table.

59 ≤ A ≤ 89

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Boron isotopic analysis in bulk silicate materials using the Neoma MS/MS MC-ICP-MS

Boron (B) isotopes are a valuable tracer with applications ranging from geological, environmental, and nuclear studies because B isotopic fractionation is highly sensitive to chemical processes yielding distinct isotopic trends in natural and anthropogenic systems. Despite this wide applicability, there remain relatively few measurements on well-described reference materials and in some cases, poor agreement between various methods. We report a method for boron isotope ratio measurement in solution on the Neoma MS/MS MC-ICP-MS specifically targeting bulk silicates. We evaluate the performance of the method and instrument as it relates to the measurement of the absolute boron isotope ratio ( 10 B/ 11 B). The results indicate that the method produces data in agreement with literature values and that the sample–standard bracketing technique is appropriate for the Neoma MS/MS MC-ICP-MS which has been in use for decades on previous generation instruments. Careful tuning of the MS/MS lenses is required to obtain precision comparable to non MS/MS equipped MC-ICP-MS. With careful tuning, internal and external precisions of ∼0.3‰ were achieved. However, when the MS/MS is not properly tuned external precisions exceed 3‰. Nevertheless, our results for IAEA B-6, BCR-2, BHVO-2 and W-2a reference materials overlap the 1σ range of previously reported 10 B/ 11 B. Data are reported for total boron quantities down to a few tens of nanograms. Our procedure yielded blanks as low as 3 ng but up to 29 ng, making blank corrections important for small samples sizes in the few 10s of nanogram range. We report B isotope ratios for AGV-2G, SL-1G, GSC-2G, GSD-2G, GSE-2G, RLS-132, RLS-140, NKT-1G, and T1-G glass reference materials that have not been previously reported in the literature.

Scott, Sean R. [Pacific Northwest National Laborat

Shape evolution in neutron-rich odd-even 105–109 Nb isotopes

Background: Neutron-rich nuclei around 𝑍 ≈ 40 are well known for exhibiting multiple shape transitions. Here, this region shows one of the sharpest shape transitions in the nuclear chart, evolving from a spherical vibrator at 𝑁 = 58 to a strongly deformed prolate shape at 𝑁 = 60. The largest deformations are observed for 38 Sr and 40 Zr . This abrupt shape transition disappears at 𝑍 = 36 and below, where a shape transition from spherical to oblate nuclei is predicted. On the other hand, for 𝑍 ≥ 42 and 𝑁 ≥ 60, the shape is known to evolve from axial to triaxial. While the even-𝑍 nuclei in this region have already been extensively studied, new insights can be gained from the studies of odd-𝑍 isotopes for a better understanding of the underlying mechanisms driving these phenomena. Purpose: The 41 Nb nuclei lie at the boundary between axially deformed Zr and triaxially deformed Mo nuclei. This work investigates the nuclear structure of very neutron-rich Nb nuclei up to 𝑁 = 68. The goal is to understand how the nuclear shape evolves as a function of isospin in this isotopic chain and provide new insights into the emergence of triaxial deformation. Methods: The structure of the neutron-rich Nb isotopes was investigated using state-of-the-art high-resolution 𝛾-ray spectroscopy of fission fragments produced via two different fission reactions. The use of 9 Be ⁢( 238 U, 𝑓) inverse kinematics, with a detection system comprising AGATA, EXOGAM, and VAMOS++, enabled the measurement of prompt and delayed 𝛾 rays from isotopically identified fission fragments, and 𝛾−𝛾−𝛾−𝛾 highfold data were obtained from a spontaneous fission source of 252 Cf using the Gammasphere array. Results: The level scheme of 105 Nb has been significantly extended, with the addition of two negative-parity bands observed for the first time. A new level scheme is proposed for 107 Nb, which is not in agreement with an earlier measurement, and new levels and transitions have been added to the very neutron-rich 109 Nb. The degree of triaxiality of the new bands is discussed on the basis of signature splitting analysis. The recently reported level scheme of 99 Nb has been revised. Conclusions: This systematic study on the Nb isotopic chain, compared to Zr and Mo, indicates that while the ground-state band exhibits a triaxial deformation, attributed to a proton hole coupled to a triaxially deformed Mo core, the negative-parity bands, based on isomeric bandheads, display an axially symmetric deformed structure, similar to that observed in the Zr isotopes, revealing the existence of a shape coexistence in the neutron-rich Nb nuclei.

Abushawish, M. [Université Claude-Bernard Lyon 1 (