Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ions Separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mass separator for low velocity ions

Separator provides broad beam of protons free of other charged species to simulate the solar wind in experiments designed to determine effect on materials.

King, H. J.↗

Wastewater Brine Purification and Recovery through Electrodialysis Ion Exchange

Reutilizing resources onboard the International Space Station (ISS) and for future deep space missions are critical for mission longevity and sustainability. Wastewater brine produced from water recovery systems contain chemical species that could be processed into a potential fertilizer for future plant systems. This can be achieved through a process called electrodialysis ion exchange. Wastewater containing inorganic salt components are fed through a series of ion exchange membranes to produce fertilizer (a phosphate rich stream), electrolysis-grade water, and other useful commodities. Electrodialysis cells consisting of anion and cation exchange membranes, monovalent anion exchange membranes, and bipolar membranes were utilized to achieve selective ion exchange. The use of the electrodialysis cells were effective for both water extraction and ion separation. Ions successfully diffused across their respective membranes into the concentrate, acid, and base streams. This resulted in pure water, a phosphate rich stream, and a separate anion/hydrogen and cation/hydroxide stream. However, sulfate and some phosphate ions were able to diffuse through the monovalent anion exchange membrane into the acid stream. This resulted in predominantly phosphate ions remaining in the concentrate. Optimization of the process was accomplished by altering flowrates of each stream and initial volumes, adjusting the power input and resulting current through each cell, and varying the starting parameters by splitting the inorganic waste input into the diluate and the concentrate. As expected, increasing the flowrate and the power input to each cell reduced the overall time of the process. However, mission constraints may require a longer duration process in order to reduce the power consumption. Further analysis will be required to determine the power input necessary to achieve ion diffusion effectively and in a timely manner.

Ion Exchange Membranes↗

One-step fabrication of robust lithium ion battery separators by polymerization-induced phase separation

Conventional lithium ion battery separators are microporous polyolefin membranes that play a passive role in the electrochemical cell. Next generation separators should offer significant performance enhancements, while being fabricated through facile, low cost approaches with the ability to readily tune physicochemical properties. This study presents a single-step manufacturing technique based on UV-initiated polymerization-induced phase separation (PIPS), wherein microporous separators are fabricated from multifunctional monomers and ethylene carbonate (EC), which functions as both the pore-forming agent (porogen) and electrolyte component in the electrochemical cell. By controlling the ratio of the 1,4-butanediol diacrylate (BDDA) monomer to ethylene carbonate, monolithic microporous membranes are readily prepared with 25 μm thickness and pore sizes and porosities ranging from 6.8 to 22 nm and 15.4% to 38.5%, respectively. With 38.5% apparent porosity and an average pore size of 22 nm, the poly(1,4-butanediol diacrylate) (pBDDA) separator takes up 127% liquid electrolyte, resulting in an ionic conductivity of 1.98 mS cm –1 , which is greater than in conventional Celgard 2500. Lithium ion battery half cells consisting of LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathodes and pBDDA separators were shown to undergo reversible charge/discharge cycling with an average discharge capacity of 142 mA h g –1 and a capacity retention of 98.4% over 100 cycles – comparable to cells using state-of-the-art separators. Moreover, similar discharge capacities were achieved in rate performance tests due to the high ionic conductivity and electrolyte uptake of the film. Finally, the pBDDA separators were shown to be thermally stable to 374 °C, lack low temperature thermal transitions that can compromise cell safety, and exhibit no thermal shrinkage up to 150 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Method and apparatus for ion mobility separations utilizing alternating current waveforms

Methods and apparatuses for ion manipulations, including ion trapping, transfer, and mobility separations, using traveling waves (TW) formed by continuous alternating current (AC) are disclosed. An apparatus for ion manipulation includes a surface to which are coupled a first plurality of continuous electrodes and a second plurality of segmented electrodes. The second plurality of segmented electrodes is arranged in longitudinal sets between or adjacent to the first plurality of electrodes. An RF voltage applied to adjacent electrodes of the first plurality of electrodes is phase shifted by approximately 180° to confine ions within the apparatus. An AC voltage waveform applied to adjacent electrodes within a longitudinal set of the second plurality of segmented electrodes is phase shifted on the adjacent electrodes by 1°-359° to move ions longitudinally through the apparatus for separation.

Garimella, Venkata B. S.↗

Improved Multiple-Species Cyclotron Ion Source

Use of pure isotope 86Kr instead of natural krypton in multiple-species ion source enables source to produce krypton ions separated from argon ions by tuning cylcotron with which source used. Addition of capability to produce and separate krypton ions at kinetic energies of 150 to 400 MeV necessary for simulation of worst-case ions occurring in outer space.

Soli, George A.↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Gas-Phase Native(-like) Proteins Using Structures for Lossless Ion Manipulations

High-resolution mobility-based ion separations in Structures for Lossless Ion Manipulations (SLIM) have been useful for ion mobility separations for a variety of molecular classes in the gas phase. Here, in this study, we present multipass SLIM separations for gas-phase proteins in their near-native state exhibiting charge-state-dependent arrival time distributions using carbonic anhydrase (29 kDa), alcohol dehydrogenase (148 kDa), and apo-transferrin (79 kDa). The experimental CCS values were obtained from calibration curves for the arrival times of Agilent Tune Mix ions. For multipass separations, the ATDs were converted to CCS values by deconvoluting the multipass arrival times into accurate single-pass values amenable to the single-pass calibration curves. Mass spectra of carbonic anhydrase (CA) showed three different charge states (z = 9+ to 11+). Their corresponding mobility peaks were baseline-separated by using 8-m single-pass separations. When compared to the corresponding drift tube ion mobility (DTIMS) measurements, the CCS values obtained from DTIMS and SLIM were in agreement within experimental error. Single-pass analysis of alcohol dehydrogenase (ADH) exhibits three predominant charge states (z = 23+ to 25+) with mobility overlap between adjacent charge states. The mobility peak resolution for ADH improved with multipass separations (up to 24-m path length). In addition, CCS distributions obtained for charge states z = 16+ to 18+ of apo-transferrin reveal a transition from a compact unimodal form (z = 18+ and 19+) to broader multimodal CCS distributions for z = 16+. For apo-transferrin, 40-m multipass separations were performed allowing for complete isolation of the selected mobility range corresponding to z = 17+, leading to selective isolation of a narrow arrival time window. The extended mobility separations provided minimal alterations to the structure of the proteins, and the experimentally derived CCS values showed minimal change as a function of the separation time or number of passes. Mobility-based ion separations for native-like proteins, using SLIM, open opportunities for native-IMS applications as well as other manipulations enabled by SLIM-like mobility-selective isolation and collection.

charge state distribution↗

Fast ground-state-to-ground-state separation of small ion crystals

Rapid separation of linear crystals of trapped ions into different subsets is critical for realizing trapped ion quantum computing architectures where ions are rearranged in trap arrays to achieve all-to-all connectivity between qubits. Here we introduce a general theoretical framework that can be used to describe the separation of same-species and mixed-species crystals into smaller subsets. The framework relies on an efficient description of the evolution of Gaussian motional states under quadratic Hamiltonians that only requires a special solution of the classical equations of motion of the ions to describe their quantum evolution under the influence of a time-dependent applied potential and the ions' mutual Coulomb repulsion. We provide time-dependent applied potentials suitable for separation of a mixed-species three-ion crystal on timescales similar to that of free expansion driven by Coulomb repulsion, with all modes along the crystal axis starting and ending close to their ground states. Three separately confined mixed-species ions can be combined into a crystal held in a single well without energy gain by time-reversal of this separation process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution mobility spectrometry in a co-axial platform

Ion mobility spectrometry is an analytical technique that separate ions in the gas phase based on their interaction with a neutral buffer gas. Ion mobility spectrometry performs separations quickly (typically less than a second) and the ion mobilities are very reproducible across different laboratories. This project aimed at evaluating the performance of a new ion mobility device. The new device relies on conducting ion mobility separation in a curved geometry. The project explored the operation landscape of the device using ion trajectory simulations then fabricated and experimentally demonstrated the device's performance. Ion trajectory simulations on a set of tetraalkylammonium and phosphazene ions indicate that ions traveling a curved path length undergo mobility separation that is similar to a straight path. The ion mobility resolution of the curved device was found to be similar to that of a straight path of a similar length. The experimental validation of the new device confirmed the device's ability to separate ions according to their mobilities. Sets of mixtures (tetraalkylammonium ions, phosphazene ions, and peptide ions) were evaluated for separation and transmission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Confinement and Zwitterionic Ligand Chemistry on Ion–Ion Selectivity of Functionalized Nanopores

Membranes incorporating zwitterionic chemistries have recently emerged as promising candidates for facilitating challenging ion–ion separations. Transport of ions in such membranes predominantly occurs in hydrated nanopores lined with zwitterionic monomers. Here, to shed light on the physics of ion–ion selectivity underlying such materials, we conducted molecular dynamics simulations of sodium halide transport in model nanopores grafted with sulfobetaine methacrylate molecules. Our results reveal that in both functionalized and unfunctionalized nanopores smaller ions prefer to reside near the pore center, while the larger ions tend to reside near the pore walls. An enhancement in the selective transport of larger anions is observed within the unfunctionalized nanopores relative to that in salt-in-water solutions. Upon functionalization of the nanopores with zwitterions (ZIs), the disparities in the anionic distribution profiles within the pores coupled with differences in the anion-ZI interactions result in a slowdown of larger anions relative to smaller anions. Increasing the ZI grafting density exacerbates these effects, further promoting the selective transport of smaller anions. Our results suggest that selectivity toward large anions can be realized by using nanoporous membranes with ZI content that is high enough to facilitate ion/water partitioning into the pores while preserving the characteristic tendency of the unfunctionalized pores to facilitate faster transport of the larger anions. On the other hand, selectivity toward smaller anions can be achieved by targeting ZI content within the pores that is high enough to significantly slow down the transport of large anions but not high enough to hinder the partitioning of ions/water molecules into the pore due to steric effects.

anions↗

Preactivated zeolite nanosheet plate-tiled membrane on porous PVDF film: Synthesis and study of proton-selective ion conduction

Preactivated MFI zeolite nanosheet plates (ZNPs) with large areas (~2.0 × 2.0 μm 2 ) and nanometer thicknesses (~60 nm) were prepared directly in liquid-dispersed state. The individual ZNP was a stack of 4-nm-thick single crystalline zeolite nanosheets (ZNs) interlinked by Si–O–Si bonds between neighboring ZN surfaces. The dispersed open-pore ZNPs allowed formulating suspensions for tiling ZNP membranes on polymer substrates without requiring post-coating activation. A pinhole-free ZNP-tiled (ZNPT) membrane has been achieved on macroporous PVDF film by a self-repairing vacuum-assisted filtration coating method. The resultant ZNPT layer was ~500 nm-thick consisting of about 7 ZNP layers with inter-ZNP width and inter-ZNP entrance porosity around 9 nm and 2%, respectively. The ZNPT-PVDF membrane exhibited high selectivity to proton transport over vanadyl ion and low resistances to proton conduction in aqueous solutions. The membrane also demonstrated to function as an efficient ion separator for the vanadium redox flow battery. The reported synthesis of preactivated ZNP suspension may overcome the major hurdle to realizing polymer-supported ZN membranes, which is the inefficiency of existing methods in obtaining readily dispersible open-pore ZNs. Finally, the ZNPT-PVDF membrane can be a more affordable and sustainable alternative to the Nafion-based ion separation membranes.

36 MATERIALS SCIENCE↗

Ion exchange selectivity for cross-linked polyacrylic acid

The ion separation factors for 21 common metal ions with cross-linked polyacrylic acid were determined as a function of pH and the percent of the cross-linked polyacrylic acid neutralized. The calcium ion was used as a reference. At a pH of 5 the decreasing order of affinity of the ions for the cross-linked polyacrylic acid was found to be: Hg++, Fe+++, Pb++, Cr+++, Cu++, Cd++, Al+++, Ag+, Zn++, Ni++, Mn++, Co++, Ca++, Sr++, Ba++, Mg++, K+, Rb+, Cs+, Na+, and Li+. Members of a chemical family exhibited similar selectivities. The Hg++ ion appeared to be about a million times more strongly bound than the alkali metal ions. The relative binding of most of the metal ions varied with pH; the very tightly and very weakly bound ions showed the largest variations with pH. The calcium ion-hydrogen ion equilibrium was perturbed very little by the presence of the other ions. The separation factors and selectivity coefficients are discussed in terms of equilibrium and thermodynamic significance.

May, C. E.↗

Probing the influence of ion-pairing on ligand-field excited-state dynamics

Exploration of the photophysical and photochemical properties of transition metal complexes has driven ground-breaking advancements in solar energy conversion technologies, including photoredox catalysis. While significant research has been devoted to understanding excited state properties of second- and third-row transition metal complexes, earth-abundant first-row metal complexes have received comparatively little attention in this context until very recently. In particular, the role of ion-pairing – which has been identified as a potentially significant factor for Ir(III)-based photosensitizers – has not been examined with regard to its influence on the ligand-field excited states that dominate much of first-row photophysics. A key challenge in studying ion-pair interactions lies in quantifying the extent and nature of ion-pairing, particularly in non-aqueous media where the vast majority of photophysical studies are performed. Cobalt(III) polypyridyl complexes provide an attractive platform to address such questions due to their demonstrated potential for applications in photoredox catalysis involving ligand-field excited states. In the present study, we prepared a cobalt(III) polypyridyl complex, [Co(4,4′-OMebpy) 3 ](BAr F 4 ) 3 (where 4,4′-OMebpy is 4,4′-dimethoxy-2,2′-bipyridine and BAr F 4 is tetrakis(3,5-bis(trifluoromethyl)-phenyl)borate) to probe ion-pairing in non-aqueous solutions. Specifically, analysis of data acquired from both variable-temperature diffusion ordered spectroscopy (DOSY) NMR and 1-D rotating-frame nuclear Overhauser effect (ROE) experiments allowed us to identify and differentiate between solvent-separated ion pairs in high-dielectric media and contact ion pairs in a low-dielectric solvent. Time-resolved absorption spectroscopy was then used to measure ground-state recovery dynamics under these varying conditions of ion-pairing, the results of which revealed an increase in excited-state lifetime for contact ion-pairs that we suggest arises from a reduction in outer-sphere reorganization energy relative to conditions which favored solvent-separated ion pairs. We believe this study demonstrates that one can leverage broadly available NMR-based methods to understand ion-pairing in non-aqueous solutions, which in turn can provide a microscopic picture of intermolecular interactions that can impact the photophysical properties of transition metal-based chromophores.

Ghosh, Atanu [Michigan State University, East Lans↗

Solvent effects on extractant conformational energetics in liquid–liquid extraction: a simulation study of molecular solvents and ionic liquids

Extractant design in liquid–liquid extraction (LLE) is a research frontier of metal ion separations that typically focuses on the direct extractant–metal interactions. However, a more detailed understanding of energetic drivers of separations beyond primary metal coordination is often lacking, including the role of solvent in the extractant phase. In this work, we propose a new mechanism for enhancing metal-complexant energetics with nanostructured solvents. Using molecular dynamics simulations with umbrella sampling, we find that the organic solvent can reshape the energetics of the extractant's intramolecular conformational landscape. Here, we calculate free energy profiles of different conformations of a representative bidentate extractant, n-octyl(phenyl)-N,N-diisobutyl carbamoyl methyl phosphinoxide (CMPO), in four different solvents: dodecane, tributyl phosphate (TBP), and dry and wet ionic liquid (IL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMIM][Tf 2 N]). By promoting reorganization of the extractant molecule into its binding conformation, our findings reveal how particular solvents can ameliorate this unfavorable step of the metal separation process. In particular, the charge alternating nanodomains formed in ILs substantially reduce the free energy penalty associated with extractant reorganization. Importantly, using alchemical free energy calculations, we find that this stabilization persists even when we explicitly include the extracted cation. These findings provide insight into the energetic drivers of metal ion separations and potentially suggest a new approach to designing effective separations using a molecular-level understanding of solvent effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An integrated approach to optimizing concentration shock wave electrodialysis using 2D multicell simulation and response surface models

Shock wave electrodialysis (SWED) is a highly promising technique for energy-efficient ion separation in the context of a circular economy. This paper presents a approach way of modeling and improving SWED using a two-dimensional multicell model combined with the COMSOL program and response surface methodology. The model integrates the Nernst-Planck equation, Darcy's law, and first-order electroosmosis to examine the local concentration, flux of ionic species, distribution of current, and velocity of flow in SWED cells under various operating conditions. We first illustrate the clear depiction of concentration, velocity, and electric potential distribution through contours which aids in identifying optimal operating conditions and designing scalable SWED systems. The results emphasize the significance of surface charge density and voltage in influencing the features of shock waves for obtaining effective ion separation while optimizing energy consumption and improving current efficiency by controlling the retention time of feed flow. Here, this study defines two crucial characteristics of shock waves, namely the length of the flat depletion zone of a fully developed shock wave (shock wave height) and the distance of shock wave propagation (shock wave length). These properties significantly impact separation performance, as determined by the simulation results. Additionally, the response surface methodology is incorporated with the COMSOL models to develop predictive models and graph responses, enabling a more comprehensive understanding of the interactions between parameters and performance indicators, such as removal ratio, energy consumption, and water recovery. Finally, this work suggests design tactics for expanding SWED processes and outlines potential areas for further research. This research provides valuable insights into the prospective applications, design optimization, and scalability of SWED in the field of electrokinetic separation technologies for green chemistry and a circular economy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes

Here, the microextraction sampling technique was integrated with triple quadrupole–inductively coupled plasma–mass spectrometry (TQ–ICP–MS) to directly sample and measure the isotopic compositions of uranium (U) and plutonium (Pu) from cotton swipes. Once extracted, the U/Pu were directed into the TQ–ICP–MS instrument for isotopic determination. Carbon dioxide (CO 2 ) and helium (He) gases were delivered to a collision reaction cell within the ICP–MS system for ion separation. The CO 2 reacts with the U + forming UO + which is ultimately separated from the Pu + ions of interest in the third quadrupole. This study demonstrates direct liquid extraction of U/Pu from a solid surface and subsequent measurement by TQ–ICP–MS in <60 s. Flow rates were optimized (0.3 mL min –1 CO 2 and 5 mL min –1 He) in the reaction cell of the ICP–MS system to maximize the Pu signal while minimizing U interferences (i.e., 238 U + tail and 238 UH + ) at m/z 239. Low levels of Pu (~2 pg) were deposited on a cotton swipe along with U at concentrations ranging from 20 to 200 ng. The 240 Pu/ 239 Pu ratio was measured with <7% relative difference from the certified value at all U concentrations. Major and minor U isotope ratios were also measured with <4% relative difference. This highlights that the microextraction–TQ–ICP–MS method can extract a mixed U/Pu sample directly from a cotton swipe and measure both isotopic systems without chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Continuous, Oriented Covalent Organic Framework Membranes for Precise Molecular Separations

The goal of achieving energy-efficient, precise molecular separations has motivated interest in developing and employing porous crystalline frameworks as membrane materials. Covalent organic frameworks (COFs) are ordered crystalline matrices composed of covalently bonded organic monomers and are synthesized via reversible reticular chemistry. COFs possess high porosity, structural tunability, and chemical and thermal stability, making them ideally suited for emerging, high-value membrane separation processes, such as ion separations, organic solvent nanofiltration, and gas separations. Although a range of COF membranes have been fabricated and tested in the past decade, these membranes are primarily polycrystalline, weakly crystalline, and/or discontinuous, resulting in suboptimal performance. In this review, we identify the properties that make COFs well-suited as membrane materials, while critically outlining the shortcomings of existing disordered COF membranes. We then highlight the recent emergence of highly crystalline, continuous, oriented two-dimensional COF membranes as a promising path forward for highly selective molecular separations. These continuous, oriented COF membranes exhibit tunable one-dimensional nanochannels, allowing for ultrafast molecular transport and precise species selectivity, thereby expanding the set of separations that can be practically achieved with membrane systems. We discuss synthesis and modification techniques that result in continuous, oriented COF membranes and evaluate the performance of such membranes for a variety of molecular separations. We conclude by identifying ongoing challenges in the development of COF membranes and outlining the future of their applications in molecular separations, which will necessarily rely on advancements in the synthesis of continuous, oriented membranes.

COF modification↗