Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion-trap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

M + (M=Ca, Ba) Cations Bound to Molecular Cavities: A New Strategy for Incorporating Molecular Quantum States into Quantum Information

This project pursued a novel strategy for incorporating multiple qubits per ion into ion-trap based quantum computing (ITQC) involving Ca + and Ba + . By forming molecular complexes of these cations with molecular-scale cages, we hypothesized that molecular energy levels could be incorporated into quantum computing while retaining key properties of the atomic ions intact. We experimented with a variety of molecular cages and found that Na + , K + , Rb + , Ca 2+ , Sr 2+ , and Ba 2+ could be captured and brought into the gas phase efficiently by imbedding them inside [2.2.2]-benzocryptand. IR and UV spectra of these cage complexes are sensitive to the size and charge state of the ion, reporting on the structures and binding properties of the cage complexes. UV photofragmentation of the Ba 2+ -Acetate -1 -BzCrypt complex produces Ba + -BzCrypt, the complex targeted for exploration in the original hypothesis. Follow-on funding is needed to pursue the spectroscopy of this complex as a target for ITQC.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lignin Sensor Based On Flash-Pyrolysis Mass Spectrometry

New lignin sensor takes only few minutes to measure lignin content of specimen of wood, pulp, paper, or similar material. Includes flash pyrolizer and ion-trap detector that acts as mass spectrometer. Apparatus measures amount of molecular fragments of lignin in pyrolysis products of samples. Helpful in controlling digestors in paper mills to maintain required lignin content, and also in bleaching plants, where good control of bleaching becomes possible if quick determination of lignin content made.

Kwack, Eug Y.↗

Transition probabilities for the 3s2 3p(2P0)-3s3p2(4P) intersystem lines of Si II

Intensity ratios of lines of the spin-changing 'intersystem' multiplet of S II (4P yields 2P0) at 234 nm have been used to determine electron densities and temperatures in a variety of astrophysical environments. However, the accuracy of these diagnostic calculations have been limited by uncertainties associated with the available atomic data. We report the first laboratory measurement, using an ion-trapping technique, of the radiative lifetimes of the three metastable levels of the 3s3p2 4P term of Si II. Our results are 104 +/- 16, 406 +/- 33, and 811 +/- 77 micro-s for lifetimes of the J = 1/2, 5/2, and 3/2 levels, respectively. A-values were derived from our lifetimes by use of measured branching fractions. Our A-values, which differ from calculated values by 30 percent or more, should give better agreement between modeled and observed Si II line ratios.

Calamai, Anthony G.↗

Elemental mass spectroscopy of remote surfaces from laser-induced plasmas

The elemental mass analysis of laser-produced ions from Al, Cu, Ge, Ag, and a lunar simulant target when irradiated by a 400-mJ, 8-ns, Nd: YAG laser at 1 x 10(exp 9) W/cm(exp 2), is reported. Ions traveled down a 11.1-m evacuated tube to an ion-trap 1-m time-of-flight (TOF) mass spectrometer where an elemental mass spectrum was recorded. The amount of target material removed per laser pulse and the ionization fraction were measured. The ion spatial distribution was measured at 11.1-m distance and found to be near a fourth-power cosine distribution. These results indicate the ability to mass analyze a surface over a distance of many kilometers for lunar and asteroid surface elemental mass analysis by a remote satellite or lunar rover.

Situ, W.↗

Space Station atmospheric monitoring systems

A technology assessment study on atmospheric monitoring systems was performed by Battelle Columbus Division for the National Aeronautics and Space Administration's John F. Kennedy Space Center under Contract No. NAS 10-11033. In this assessment, the objective was to identify, analyze, and recommend systems to sample and measure Space Station atmospheric contaminants and identify where additional research and technology advancements were required. To achieve this objective, it was necessary to define atmospheric monitoring requirements and to assess the state of the art and advanced technology and systems for technical and operational compatibility with monitoring goals. Three technical tasks were defined to support these needs: Definition of Monitoring Requirements, Assessment of Sampling and Analytical Technology, and Technology Screening and Recommendations. Based on the analysis, the principal candidates recommended for development at the Space Station's initial operational capability were: (1) long-path Fourier transform infrared for rapid detection of high-risk contamination incidences, and (2) gas chromatography/mass spectrometry utilizing mass selective detection (or ion-trap) technologies for detailed monitoring of extended crew exposure to low level (ppbv) contamination. The development of a gas chromatography/mass spectrometry/matrix isolation-Fourier transform infrared system was recommended as part of the long range program of upgrading Space Station trace-contaminant monitoring needs.

Air Pollution, Indoor/analysis↗

Quadrupole Ion Mass Spectrometer for Masses of 2 to 50 Da

A customized quadrupole ion-trap mass spectrometer (QITMS) has been built to satisfy a need for a compact, rugged instrument for measuring small concentrations of hydrogen, helium, oxygen, and argon in a nitrogen atmosphere. This QITMS can also be used to perform quantitative analyses of other gases within its molecular-mass range, which is 2 to 50 daltons (Da). (More precisely, it can be used to perform quantitative analysis of gases that, when ionized, are characterized by m/Z ratios between 2 and 50, where m is the mass of an ion in daltons and Z is the number of fundamental electric charges on the ion.

Helms, William↗

Demonstration of Long Vacuum Integrity Lifetime of Trapped Ion Standard Package

A compact Hg ion trap package that was vacuum-sealed since 9 years has been demonstrated to be successfully operational showing excellent ion-trap lifetime exceeding 400 days. In addition to the vacuum package, the same 9-year old optical and detection packages are utilized to obtain these results. Charge transfer relaxation effects between neutral Hg and trapped Hg ion are studied. This work shows the reliability of such units in view of next-generation ground and space-borne trapped ion clocks.

charge-transfer relaxation↗

Synthesis of cerium precursors with alkoxide ligands for degradation to cerium oxide nanoparticles

Lanthanide oxide and sulfide nanoparticles present intriguing theoretical questions regarding their electronic structures, alongside numerous potential applications in material science and catalysis. Although these materials can be formed through hydrolysis, their synthesis via thermolysis is crucial for nanoscale materials and practical applications. This research aims to enhance our understanding of the decomposition mechanisms by focusing on cerium compounds, which are analogous to those studied previously. Currently, our knowledge of the decomposition mechanisms of cerium alkoxide precursors is limited. The objective of this project is to develop a mechanistic understanding of the formation of cerium oxide nanoparticles from cerium alkoxide precursors, employing a variety of techniques. These techniques include collision-induced dissociation in an ion-trap mass spectrometer, nuclear magnetic resonance (NMR) spectroscopy, thermogravimetric analysis coupled with differential scanning calorimetry (TGA-DSC), and gas chromatography-mass spectrometry (GC-MS) to investigate the decomposition mechanisms of the synthesized precursors.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Producing two-dimensional dust clouds and clusters using a movable electrode for complex plasma and fundamental physics experiments

We report a Bidirectional Electrode Control Arm Assembly (BECAA) for precisely manipulating dust clouds levitated above the powered electrode in RF plasmas. The reported techniques allow the creation of perfectly 2D dust layers by eliminating off-plane particles by moving the electrode from outside the plasma chamber without altering the plasma conditions. Here, the tilting and moving of electrodes using BECAA also allows the precise and repeatable elimination of dust particles one by one to achieve any desired number of grains N without trial and error. Simultaneously acquired top and side view images of dust clusters show that they are perfectly planar or 2D. A demonstration of clusters with N = 1–28 without changing the plasma conditions is presented to show the utility of BECAA for complex plasma and statistical physics experimental design. Demonstration videos and 3D printable part files are available for easy reproduction and adaptation of this new method to repeatably produce 2D clusters in existing RF plasma chambers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photon-mediated entanglement scheme between a ZnO semiconductor defect and a trapped Yb ion

We propose an optical scheme to generate an entangled state between a trapped ion and a solid state donor qubit through which-path erasure of identical photons emitted from the two systems. The proposed scheme leverages the similar transition frequencies between In donor bound excitons in ZnO and the 2 P 1/2 to 2 S 1/2 transition in Yb+. The lifetime of the relevant ionic state is longer than that of the ZnO system by a factor of 6, leading to a mismatch in the temporal profiles of emitted photons. A detuned cavity-assisted Raman scheme weakly excites the donor with a shaped laser pulse to generate photons with a 0.99 temporal overlap to the Yb+ emission and partially shift the emission of the defect toward the Yb+ transition. Here, the remaining photon shift is accomplished via the dc Stark effect. We show that an entanglement rate of 2.1 × 10 4 s –1 and an entanglement fidelity of 94% can be attained using a weak excitation scheme with reasonable parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Normal modes, rotational inertia, and thermal fluctuations of trapped ion crystals

The normal modes of a trapped ion crystal are derived using an approach based on the Hermitian properties of the system’s dynamical matrix. This method is equivalent to the standard Bogoliubov method, but for classical systems it is arguably simpler and more general in that canonical coordinates are not necessary. The theory is developed for stable, unstable, and neutrally-stable systems. The method is then applied to ion crystals in a Penning trap. Reduced eigenvalue problems for the case of large applied magnetic field are developed, for which the spectrum breaks into E x B drift modes, axial modes, and cyclotron modes. Thermal fluctuation levels in these modes are analyzed and shown to be consistent with the Bohr-van-Leeuwen theorem, provided that neutrally-stable modes associated with crystal rotations are included in the analysis. An expression for the rotational inertia of the crystal is derived, and a magnetic contribution to this inertia, which dominates in large magnetic fields, is described. An unusual limit is discovered for the special case of spherically-symmetric confinement, in which the rotational inertia does not exist and changes in angular momentum leave the rotation frequency unaffected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

Adaptively controlled fast production of defect-free beryllium ion crystals using pulsed laser ablation

Trapped atomic ions find wide applications ranging from precision measurement to quantum information science and quantum computing. Beryllium ions are widely used due to the light mass and convenient atomic structure of beryllium; however, conventional ion loading from thermal ovens exerts undesirable gas loads for a prolonged duration. Here, we demonstrate a method to rapidly produce pure linear chains of beryllium ions with pulsed laser ablation, serving as a starting point for large-scale quantum information processing. Our method is fast compared to thermal ovens, reduces the gas load to only 10 -12 Torr (10 -10 Pa) level, yields a short recovery time of a few seconds, and also eliminates the need for a deep ultraviolet laser for photoionization. We also study the loading dynamics, which show non-Poissonian statistics in the presence of sympathetic cooling. In addition, we apply feedback control to obtain defect-free ion chains with desirable lengths.

47 OTHER INSTRUMENTATION↗

Observation of a dipole-bound excited state in 4-ethynylphenoxide and comparison with the quadrupole-bound excited state in the isoelectronic 4-cyanophenoxide

Negative ions do not possess Rydberg states, but can have Rydberg-like nonvalence excited states near the electron detachment threshold, including dipole-bound states (DBSs) and quadrupole-bound states (QBSs). While DBSs have been studied extensively, quadrupole-bound excited states have been more rarely observed. 4-cyanophenoxide (4CP – ) was the first anion observed to possess a quadrupole-bound exited state 20 cm-1 below its detachment threshold. Here we report the observation of a DBS in the isoelectronic 4-ethynylphenoxide anion (4EP – ), providing a rare opportunity to compare the behaviors of a dipole-bound and a quadrupole-bound excited state in a pair of very similar anions. Photodetachment spectroscopy (PDS) of cryogenically-cooled 4EP – reveals a DBS 76 cm -1 below its detachment threshold. Photoelectron spectroscopy (PES) at 266 nm shows that the electronic structure of 4EP – and 4CP – are nearly identical. The observed vibrational features in both the PDS and PES, as well as autodetachment from the nonvalence excited states, are also found to be similar for both anions. However, resonant two-photon detachment (R2PD) from the bound vibrational ground state is observed to be very different for the DBS in 4EP – and the QBS in 4CP – . The R2PD spectra reveal that decays take place from both the DBS and QBS to the respective anion ground electronic states within the 5 ns detachment laser pulse due to internal conversion followed by intramolecular vibrational redistribution (IVR), but the decay mechanisms appear to be very different. In the R2PD spectrum of 4EP – , we observe strong threshold electron signals, which are due to detachment, by the second photon, of highly rotationally excited anions resulted from the decay of the DBS. On the other hand, in the R2PD spectrum of 4CP – we observe well-resolved vibrational peaks due to the three lowest-frequency vibrational modes of 4CP – , which are populated from the decay of the QBS. Here, the different behaviors of the R2PD spectra suggest unexpected differences between the relaxation mechanisms of the dipole-bound and quadrupole-bound excited states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ablation loading of barium ions into a surface-electrode trap

Trapped-ion quantum information processing may benefit from qubits encoded in isotopes that are practically available in only small quantities, e.g., due to low natural abundance or radioactivity. Laser ablation provides a method of controllably liberating neutral atoms or ions from low-volume targets, but energetic ablation products can be difficult to confine in the small ion-electrode distance, micron-scale microfabricated traps amenable to high-speed, high-fidelity manipulation of ion arrays. Here, we investigate ablation-based ion loading into surface-electrode traps of different sizes to test a model describing ion loading probability as a function of effective trap volume and other trap parameters. We characterize loading of ablated barium from a metallic source in two cryogenic surface-electrode traps with 730 and 50 μm ion-electrode distances. Furthermore, our loading rate agrees with a predictive analytical model, providing insight for the confinement of limited-quantity species of interest for quantum computing, simulation, and sensing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of 3 cm 3 ion trap vacuum package sealed for 10 years

Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10 -13 $τ$ -1/2 integrating down to 1×10 -14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.

74 ATOMIC AND MOLECULAR PHYSICS↗