Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverse Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SU-E-T-148: Efficient Verification Method for Modulated Electron Radiotherapy Treatment Plans

Purpose: For shallow tumors, modulated electron radiotherapy (MERT) promises a reduction of dose to distal organs at risk. At our institution a framework was developed in order to create treatment plans for MERT employing both forward and inverse optimization. In this work, an efficient quality assurance (QA) process is established. Methods: Treatment plans for three different tumor sites were created using an inverse optimization. These plans consist of 6–12 segments and energies between 6 and 18 MeV. An already established QA process for photon IMRT plans is now extended to additionally handle MERT plans. First, the dose distributions are calculated in a homogenous water phantom. For this task a dedicated Monte Carlo (MC) framework for MERT is used. Second, the segments are applied on a stand-alone amorphous silicon electronic portal imaging device (EPID) using a source-to-surface distance of 70 cm. This device was calibrated for electron beams in a previous work. An in-house developed analysis software, is then utilized for comparisons and evaluation of the measured and calculated dose distributions. Results: For all three plans the calculated dose distributions agree well with the measured ones. Using a 2D gamma comparison (2% of dose max/2 mm and 10% dose threshold) passing rates >98% are achieved.The dose calculation for each plan on the water phantom, using voxels of 0.2×0.2×0.2 cm{sup 3}, takes at maximum 30 min on a single core Pentium 2.66 GHz system with 6 GB RAM, to reach a statistical uncertainty of 2% (1 std. dev.). Conclusion: An already established QA procedure for IMRT photon plans was applied for MERT. The dedicated MC framework and the use of EPID measurements allow an efficient QA procedure in a clinical environment. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Novel tools for stepping source brachytherapy treatment planning: Enhanced geometrical optimization and interactive inverse planning

Purpose: Dose optimization for stepping source brachytherapy can nowadays be performed using automated inverse algorithms. Although much quicker than graphical optimization, an experienced treatment planner is required for both methods. With automated inverse algorithms, the procedure to achieve the desired dose distribution is often based on trial-and-error. Methods: A new approach for stepping source prostate brachytherapy treatment planning was developed as a quick and user-friendly alternative. This approach consists of the combined use of two novel tools: Enhanced geometrical optimization (EGO) and interactive inverse planning (IIP). EGO is an extended version of the common geometrical optimization method and is applied to create a dose distribution as homogeneous as possible. With the second tool, IIP, this dose distribution is tailored to a specific patient anatomy by interactively changing the highest and lowest dose on the contours. Results: The combined use of EGO–IIP was evaluated on 24 prostate cancer patients, by having an inexperienced user create treatment plans, compliant to clinical dose objectives. This user was able to create dose plans of 24 patients in an average time of 4.4 min/patient. An experienced treatment planner without extensive training in EGO–IIP also created 24 plans. The resulting dose-volume histogram parameters were comparable to the clinical plans and showed high conformance to clinical standards. Conclusions: Even for an inexperienced user, treatment planning with EGO–IIP for stepping source prostate brachytherapy is feasible as an alternative to current optimization algorithms, offering speed, simplicity for the user, and local control of the dose levels.

60 APPLIED LIFE SCIENCES↗

Delivery validation of an automated modulated electron radiotherapy plan

Purpose: Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In this work, the authors investigate the accuracy and efficiency of an end-to-end MERT plan and automated delivery method. Methods: Treatment planning was initiated on a previously treated whole breast irradiation case including an electron boost. All dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. Results: The automated delivery, which covered four electron energies, 196 subfields, and 6183 total MU was completed in 25.8 min, including 6.2 min of beam-on time. The remainder of the delivery time was spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. Comparison of the planned and delivered film dose gave 3%/3mm gamma pass rates of 62.1%, 99.8%, 97.8%, 98.3%, and 98.7% for the 9, 12, 16, and 20 MeV, and combined energy deliveries, respectively. Delivery was also performed with a MapCHECK device and resulted in 3%/3 mm gamma pass rates of 88.8%, 86.1%, 89.4%, and 94.8% for the 9, 12, 16, and 20 MeV energies, respectively. Conclusions: Results of the authors’ study showed that an accurate delivery utilizing an add-on tertiary electron collimator is possible using Monte Carlo calculated plans and inverse optimization, which brings MERT closer to becoming a viable option for physicians in treating superficial malignancies.

60 APPLIED LIFE SCIENCES↗

Predicting objective function weights from patient anatomy in prostate IMRT treatment planning

Purpose: Intensity-modulated radiation therapy (IMRT) treatment planning typically combines multiple criteria into a single objective function by taking a weighted sum. The authors propose a statistical model that predicts objective function weights from patient anatomy for prostate IMRT treatment planning. This study provides a proof of concept for geometry-driven weight determination. Methods: A previously developed inverse optimization method (IOM) was used to generate optimal objective function weights for 24 patients using their historical treatment plans (i.e., dose distributions). These IOM weights were around 1% for each of the femoral heads, while bladder and rectum weights varied greatly between patients. A regression model was developed to predict a patient's rectum weight using the ratio of the overlap volume of the rectum and bladder with the planning target volume at a 1 cm expansion as the independent variable. The femoral head weights were fixed to 1% each and the bladder weight was calculated as one minus the rectum and femoral head weights. The model was validated using leave-one-out cross validation. Objective values and dose distributions generated through inverse planning using the predicted weights were compared to those generated using the original IOM weights, as well as an average of the IOM weights across all patients. Results: The IOM weight vectors were on average six times closer to the predicted weight vectors than to the average weight vector, usingl{sub 2} distance. Likewise, the bladder and rectum objective values achieved by the predicted weights were more similar to the objective values achieved by the IOM weights. The difference in objective value performance between the predicted and average weights was statistically significant according to a one-sided sign test. For all patients, the difference in rectum V54.3 Gy, rectum V70.0 Gy, bladder V54.3 Gy, and bladder V70.0 Gy values between the dose distributions generated by the predicted weights and IOM weights was less than 5 percentage points. Similarly, the difference in femoral head V54.3 Gy values between the two dose distributions was less than 5 percentage points for all but one patient. Conclusions: This study demonstrates a proof of concept that patient anatomy can be used to predict appropriate objective function weights for treatment planning. In the long term, such geometry-driven weights may serve as a starting point for iterative treatment plan design or may provide information about the most clinically relevant region of the Pareto surface to explore.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data-Driven Pricing Strategy for Demand-Side Resource Aggregators

We consider a utility who seeks to coordinate the energy consumption of multiple demand-side flexible resource aggregators. For the purpose of privacy protection, the utility has no access to the detailed information of loads of resource aggregators. Instead, we assume that the utility can directly observe each aggregator's aggregate energy consumption outcomes. Furthermore, the utility can leverage resource aggregator energy consumption via time-varying electricity price profiles. Based on inverse optimization technique, we propose an estimation method for the utility to infer the energy requirement information of aggregators. Subsequently, we design a data-driven pricing scheme to help the utility achieve system-level control objectives (e.g., minimizing peak demand) by combining hybrid particle swarm optimizer with mutation algorithm and an iterative algorithm. Case studies have demonstrated the effectiveness of the proposed approach against two benchmark pricing strategies-a flat-rate scheme and a time-of-use scheme.

data-driven optimization↗

Optimal beam margins in linac-based VMAT stereotactic ablative body radiotherapy: a Pareto front analysis for liver metastases

We explored the Pareto fronts mathematical strategy to determine the optimal block margin and prescription isodose for stereotactic body radiotherapy (SBRT) treatments of liver metastases using the volumetric-modulated arc therapy (VMAT) technique. Three targets (planning target volumes [PTVs] = 20, 55, and 101 cc) were selected. A single fraction dose of 26 Gy was prescribed (prescription dose [PD]). VMAT plans were generated for 3 different beam energies. Pareto fronts based on (1) different multileaf collimator (MLC) block margin around PTV and (2) different prescription isodose lines (IDL) were produced. For each block margin, the greatest IDL fulfilling the criteria (95% of PTV reached 100%) was considered as providing the optimal clinical plan for PTV coverage. Liver D{sub mean}, V7Gy, and V12Gy were used against the PTV coverage to generate the fronts. Gradient indexes (GI and mGI), homogeneity index (HI), and healthy liver irradiation in terms of D{sub mean}, V7Gy, and V12Gy were calculated to compare different plans. In addition, each target was also optimized with a full-inverse planning engine to obtain a direct comparison with anatomy-based treatment planning system (TPS) results. About 900 plans were calculated to generate the fronts. GI and mGI show a U-shaped behavior as a function of beam margin with minimal values obtained with a +1 mm MLC margin. For these plans, the IDL ranges from 74% to 86%. GI and mGI show also a V-shaped behavior with respect to HI index, with minimum values at 1 mm for all metrics, independent of tumor dimensions and beam energy. Full-inversed optimized plans reported worse results with respect to Pareto plans. In conclusion, Pareto fronts provide a rigorous strategy to choose clinical optimal plans in SBRT treatments. We show that a 1-mm MLC block margin provides the best results with regard to healthy liver tissue irradiation and steepness of dose fallout.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-201-03: Combined Use of 192Ir, 60Co, and 169Yb Sources with the Novel Direction Modulated Brachytherapy Tandem Applicator for High Dose Rate Brachytherapy Planning of Cervical Cancer

Purpose: To evaluate the improvement in plan quality when various combinations of 192Ir, 60Co, and 169Yb sources are used in combination with a novel direction modulated brachytherapy (DMBT) tandem applicator for high dose rate brachytherapy of cervical cancer. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy (IGABT), especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles - leading to enhanced dose sculpting capacity through inverse planning. Monte Carlo simulations of the three HDR sources individually inside the DMBT applicator were performed and imported into an in-house developed inverse optimization code. We then performed inverse planning with 14 cervical cancer patients enrolled in EMBRACE study. In all patients, 3D MRI-based planning was performed while utilizing 1) tandem-ring and needles attached-to-ring (7 patients) and 2) tandem-ring and needles both attached-to-ring and free-hand-loaded (7 patients), in accordance with the GEC-ESTRO recommendations. All plans were normalized to receive the same HRCTV D90 and DVH parameters were evaluated. Results: The DMBT tandem was used in all cases. Overall, the combined use of two sources (192Ir-60Co and 192Ir-169Yb, but not 60Co-169Yb) generally produced better quality plans than with the 192Ir source alone in terms of sparing OARs. For example, up to 3.5, 4.4, and 3.9% individual reductions in D2cc were observed for the bladder, rectum, and sigmoid, respectively, between 192Ir-60Co and 192Ir-only plans for patient cases in #1. While up to 5.5, 2.0, and 5.7% individual reductions were observed for patient cases in #2. Conclusion: We have demonstrated that, in addition to “directional modulation” of DMBT, use of multiple sources with sufficient differences in energy can be utilized to achieve additional improvement in plan quality for IGABT of cervical cancer.

60 APPLIED LIFE SCIENCES↗

Robust A-Optimal Experimental Design for Sensor Placement in Bayesian Linear Inverse Problems

Optimal design of experiments for Bayesian inverse problems has recently gained wide popularity and attracted much attention, especially in the computational science and Bayesian inversion communities. An optimal design maximizes a predefined utility function that is formulated in terms of the elements of an inverse problem, an example being optimal sensor placement for parameter identification. The state-of-the-art algorithmic approaches following this simple formulation generally overlook misspecification of the elements of the inverse problem, such as the prior or the measurement uncertainties. This work presents an efficient algorithmic approach for designing optimal experimental design schemes for Bayesian linear inverse problems such that the optimal design is robust to misspecification of elements of the inverse problem. Specifically, we consider a worst-case scenario approach for the uncertain or misspecified parameters, formulate robust objectives, and propose an algorithmic approach for optimizing such objectives. Furthermore, both relaxation and stochastic solution approaches are discussed with detailed analysis and insight into the interpretation of the problem and the proposed algorithmic approach. Extensive numerical experiments to validate and analyze the proposed approach are carried out for sensor placement in a parameter identification problem.

Bayesian inverse problems↗

SU-E-T-214: Intensity Modulated Proton Therapy (IMPT) Based On Passively Scattered Protons and Multi-Leaf Collimation: Prototype TPS and Dosimetry Study

Purpose. Intensity-modulated proton therapy is usually implemented with multi-field optimization of pencil-beam scanning (PBS) proton fields. However, at the view of the experience with photon-IMRT, proton facilities equipped with double-scattering (DS) delivery and multi-leaf collimation (MLC) could produce highly conformal dose distributions (and possibly eliminate the need for patient-specific compensators) with a clever use of their MLC field shaping, provided that an optimal inverse TPS is developed. Methods. A prototype TPS was developed in MATLAB. The dose calculation process was based on a fluence-dose algorithm on an adaptive divergent grid. A database of dose kernels was precalculated in order to allow for fast variations of the field range and modulation during optimization. The inverse planning process was based on the adaptive simulated annealing approach, with direct aperture optimization of the MLC leaves. A dosimetry study was performed on a phantom formed by three concentrical semicylinders separated by 5 mm, of which the inner-most and outer-most were regarded as organs at risk (OARs), and the middle one as the PTV. We chose a concave target (which is not treatable with conventional DS fields) to show the potential of our technique. The optimizer was configured to minimize the mean dose to the OARs while keeping a good coverage of the target. Results. The plan produced by the prototype TPS achieved a conformity index of 1.34, with the mean doses to the OARs below 78% of the prescribed dose. This Result is hardly achievable with traditional conformal DS technique with compensators, and it compares to what can be obtained with PBS. Conclusion. It is certainly feasible to produce IMPT fields with MLC passive scattering fields. With a fully developed treatment planning system, the produced plans can be superior to traditional DS plans in terms of plan conformity and dose to organs at risk.

60 APPLIED LIFE SCIENCES↗

SU-E-T-183: Feasibility of Extreme Dose Escalation for Glioblastoma Multiforme Using 4π Radiotherapy

Purpose: GBM recurrence primarily occurs inside or near the high-dose radiation field of original tumor site requiring greater than 100 Gy to significantly improve local control. We utilize 4π non-coplanar radiotherapy to test the feasibility of planning target volume (PTV) margin expansions or extreme dose escalations without incurring additional radiation toxicities. Methods: 11 GBM patients treated with VMAT to a prescription dose of 59.4 Gy or 60 Gy were replanned with 4π. Original VMAT plans were created with 2 to 4 coplanar or non-coplanar arcs using 3 mm hi-res MLC. The 4π optimization, using 5 mm MLC, selected and inverse optimized 30 beams from a candidate pool of 1162 beams evenly distributed through 4π steradians. 4π plans were first compared to clinical plans using the same prescription dose. Two more studies were then performed to respectively escalate the GTV and PTV doses to 100 Gy, followed by a fourth plan expanding the PTV by 5 mm and maintaining the prescription dose. Results: The standard 4π plan significantly reduced (p<0.01) max and mean doses to critical structures by a range of 47.0–98.4% and 61.0–99.2%, respectively. The high dose PTV/high dose GTV/expanded PTV studies showed a reduction (p<0.05) or unchanged* (p>0.05) maximum dose of 72.1%/86.7%/77.1% (chiasm), 7.2%*/27.7%*/30.7% (brainstem), 39.8%*/84.2%/51.9%* (spinal cord), 69.0%/87.0%/66.9% (L eye), 76.2%/88.1%/84.1% (R eye), 95.0%/98.6%/97.5% (L lens), 93.9%/98.8%/97.6% (R lens), 74.3%/88.5%/72.4% (L optical nerve), 80.4%/91.3%/75.7% (R optical nerve), 64.8%/84.2%/44.9%* (L cochlea), and 85.2%/93.0%/78.0% (R cochlea), respectively. V30 and V36 for both brain and (brain - PTV) were reduced for all cases except the high dose PTV plan. PTV dose coverage increased for all 4π plans. Conclusion: Extreme dose escalation or further margin expansion is achievable using 4π, maintaining or reducing OAR doses. This study indicates that clinical trials employing 4π delivery using prescription doses up to 100 Gy are feasible. Funding support partially contributed by Varian.

60 APPLIED LIFE SCIENCES↗

Deterministic direct aperture optimization using multiphase piecewise constant segmentation

Purpose Direct aperture optimization (DAO) attempts to incorporate machine constraints in the inverse optimization to eliminate the post‐processing steps in fluence map optimization (FMO) that degrade plan quality. Current commercial DAO methods utilize a stochastic or greedy approach to search a small aperture solution space. In this study, we propose a novel deterministic direct aperture optimization that integrates the segmentation of fluence map in the optimization problem using the multiphase piecewise constant Mumford‐Shah formulation. Methods The Mumford‐Shah based direct aperture optimization problem was formulated to include an L2‐norm dose fidelity term to penalize differences between the projected dose and the prescribed dose, an anisotropic total variation term to promote piecewise continuity in the fluence maps, and the multiphase piecewise constant Mumford‐Shah function to partition the fluence into pairwise discrete segments. A proximal‐class, first‐order primal‐dual solver was implemented to solve the large scale optimization problem, and an alternating module strategy was implemented to update fluence and delivery segments. Three patients of varying complexity—one glioblastoma multiforme (GBM) patient, one lung (LNG) patient, and one bilateral head and neck (H&N) patient with 3 PTVs—were selected to test the new DAO method. For each patient, 20 non‐coplanar beams were first selected using column generation, followed by the Mumford‐Shah based DAO (DAO MS ). For comparison, a popular and successful approach to DAO known as simulated annealing—a stochastic approach—was replicated. The simulated annealing DAO (DAO SA ) plans were then created using the same beam angles and maximum number of segments per beam. PTV coverage, PTV homogeneity , and OAR sparing were assessed for each plan. In addition, high dose spillage, defined as the 50% isodose volume divided by the tumor volume, as well as conformity, defined as the van't Riet conformation number, were evaluated. Results DAO MS achieved essentially the same OAR doses compared with the DAO SA plans for the GBM case. The average difference of OAR D max and D mean between the two plans were within 0.05% of the plan prescription dose. The lung case showed slightly improved critical structure sparing using the DAO MS approach, where the average OAR D max and D mean were reduced by 3.67% and 1.08%, respectively, of the prescription dose. The DAO MS plan substantially improved OAR dose sparing for the H&N patient, where the average OAR D max and D mean were reduced by over 10% of the prescription dose. The DAO MS and DAO SA plans were comparable for the GBM and LNG PTV coverage, while the DAO MS plan substantially improved the H&N PTV coverage, increasing D99 by 6.98% of the prescription dose. For the GBM and LNG patients, the DAO MS and DAO SA plans had comparable high dose spillage but slightly worse conformity with the DAO MS approach. For the H&N plan, DAO MS was considerably superior in high dose spillage and conformity to the DAO SA . The deterministic approach is able to solve the DAO problem substantially faster than the simulated annealing approach, with a 9.5‐ to 40‐fold decrease in total solve time, depending on the patient case. Conclusions A novel deterministic direct aperture optimization formulation was developed and evaluated. It combines fluence map optimization and the multiphase piecewise constant Mumford‐Shah segmentation into a unified framework, and the resulting optimization problem can be solved efficiently. Compared to the widely and commercially used simulated annealing DAO approach, it showed comparable dosimetry behavior for simple plans, and substantially improved OAR sparing, PTV coverage, PTV homogeneity, high dose spillage, and conformity for the more complex head and neck plan.

Nguyen, Dan↗

SU-E-T-567: A Three-Field Mono-Isocentric Inverse Treatment Planning Method for the Patients with Larger Breasts

Purpose: The purpose of this study is to develop a three-field monoisocentric inverse breast treatment planning technique without the use of half-beam block. Methods: Conventional three-field breast treatment with supraclavicular half-beam blocked requires two isocenters when the breast is too large to be contained within half-beam. The inferior border of the supraclavicular field and superior borders of the breast fields are matched on patient's skin with the light field. This method causes a large dose variation in the matching region due to daily setup uncertainties and requires a longer treatment setup time. We developed a three-field mono-isocentric planning method for the treatment of larger breasts. The three fields share the same isocenter located in the breast. Beam matching is achieved by rotating collimator, couch and gantry. Furthermore, we employed a mixed open-IMRT inverse optimization method to improve dose uniformity and coverage. Results: Perfect geometric beam matching was achieved by rotating couch, collimator and gantry together. Treatment setup time was significantly reduced without light-field matching during treatment deliveries. Inverse mixed open-IMRT optimization method achieved better dose uniformity and PTV coverage while keeping sufficient air flash to compensate setup and breast shape changes in daily treatments. Conclusion: By eliminating light field matching, the three-field mono-isocentric treatment method can significantly reduce setup time and uncertainty for large breast patients. Plan quality is further improved by inverse IMRT planning.

60 APPLIED LIFE SCIENCES↗

Stochastic Optimization of Complex Systems

This project focused on methodologies for the solution of stochastic optimization problems based on relaxation and penalty methods, Monte Carlo simulation, parallel processing, and inverse optimization. The main results of the project were the development of a convergent method for the solution of models that include expectation constraints as in equilibrium models, improvement of Monte Carlo convergence through the use of a new method of sample batch optimization, the development of new parallel processing methods for stochastic unit commitment models, and the development of improved methods in combination with parallel processing for incorporating automatic differentiation methods into optimization.

97 MATHEMATICS AND COMPUTING↗

Lightweight Metal Stamping Optimization Enabled by Artificial Intelligence

Successfully manufacturing an automotive body structure made via the sheet metal stamping process depends upon simultaneous consideration of component design, tooling design, stamping process control, and material properties. In many cases, introducing lightweight sheet materials (e.g., aluminum alloys, magnesium alloys, advanced high strength steels) holds the potential to significantly reduce vehicle weight, but challenges the stamping process by introducing materials with inherently less ductility. Successful and repeatable applications require co-developing the stamping process controls with the varying material properties, including formability. During the stamping process, as soon as the forming limit of the sheet is exceeded, the material shows localized necking which quickly leads to splits. Controlling process variability to avoid these material splits will enable deployment of less formable, lighter, and stronger materials for stamped automotive components. A typical optimization procedure for manufacturing requires an iterative process involving parameter setting, execution of computational simulations, and modifying the parameters. The entire process demands substantial computational time, making it impractical for real-time feedback towards rapid corrective actions required for in-line control for running production processes. To overcome this challenge, artificial intelligence (AI) can be leveraged to determine optimal manufacturing parameters within a single manufacturing cycle time. This research proposes an in-line optimization framework incorporating a trained AI model to predict kidney-shaped die forming. Preliminary results indicate that the AI framework can accurately predict draw-in values based on a given parameter set, a process referred to as forward prediction. Furthermore, the AI framework can also predict the optimal parameter set that leads to the desired draw-in values, referred to as inverse optimization (or backward prediction). This research has been performed in collaborations with USCAR (US Council for Automotive Research) and AutoForm. The members of USCAR are Ford, GM, and Stellantis.

36 MATERIALS SCIENCE↗

SU-E-J-36: Combining CBCT Dose Into IMRT Treatment Planning

Purpose: Cone beam CT (CBCT) is increasingly used in patient setup for IMRT. Daily CBCT may provide effective localization, however, it introduces concern over excessive imaging dose. Previous studies investigated the calculation of excess CBCT dose, however, no study has yet treated this dose as a source of therapeutic radiation, optimized in consideration of PTV and OARs constrains. Here we present a novel combined MV+kV inverse optimization engine to weave the CBCT and MV dose together such that CBCT dose is used for both imaging and therapeutic purposes. This may mitigate some of the excess imaging dose effects of daily CBCT and allow complete evaluation of the CBCT dose prior to treatment. Methods: The EGSnrc Monte Carlo system was used to model a Varian Trilogy CBCT system and 6 MV treatment beam. Using the model, the dose to patient from treatment beam and imaging beam was calculated for ten patients. The standard IMRT objective function was modified to include CBCT dose. Treatment plan optimization using the MOSEK optimization tool was performed retrospectively with and without assuming kV radiation dose from CBCT, assuming one CBCT per fraction. Results: Across ten patients, the CBCT delivered peaks of between .4% and 3.0% of the prescription dose to the PTV, with average CBCT dose to the PTV between .3% and .8%. By including CBCT dose to skin as a constraint during optimization, peak skin dose is reduced by between 1.9% and 7.4%, and average skin dose is reduced by .2% to 3.3%. Conclusions: Pre-treatment CBCT may deliver a substantial amount of radiation dose to the target volume. By considering CBCT dose to skin at the point of treatment planning, it is possible to reduce patient skin dose from current clinical levels, and to provide patient treatment with the improved accuracy that daily CBCT provides.

60 APPLIED LIFE SCIENCES↗

Complex optimization for big computational and experimental neutron datasets

Here, we present a framework to use high performance computing to determine accurate solutions to the inverse optimization problem of big experimental data against computational models. We demonstrate how image processing, mathematical regularization, and hierarchical modeling can be used to solve complex optimization problems on big data. We also demonstrate how both model and data information can be used to further increase solution accuracy of optimization by providing confidence regions for the processing and regularization algorithms. Finally, we use the framework in conjunction with the software package SIMPHONIES to analyze results from neutron scattering experiments on silicon single crystals, and refine first principles calculations to better describe the experimental data.

36 MATERIALS SCIENCE↗