Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Interfacial flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of variable deceleration periods on Rayleigh-Taylor instability with acceleration reversals

The dynamics of an interfacial flow that is initially Rayleigh-Taylor unstable but becomes statically stable for some intermediate period due to the reversal of the externally imposed acceleration field is studied. We discuss scenarios that consider both single and double-acceleration reversals. The accel-decel (AD) case consists of a single reversal imposed at an instant after the constant acceleration instability has entered a self-similar regime. The layer of mixed fluid ceases to grow upon acceleration reversal, and the dominant mechanics are due to internal wave oscillations. Variation of mass flux and the Reynolds stress anisotropy is observed due to the action of the internal waves. Here, a second reversal of the AD case that is termed as accel-decel-accel, ADA is then explored; the response of the mixing layer is shown to depend strongly on the duration and the periodicity of the Reynolds stress anisotropy of the mixing layer during the deceleration period. We explore the effect of this variable deceleration period after the second acceleration reversal where the flow once again becomes Rayleigh-Taylor unstable based on metrics that include the integral mixing-layer width, bubble and spike amplitudes, mass flux, Reynolds stress anisotropy tensor, and the molecular mixing parameter.

42 ENGINEERING↗

Device design and flow scaling for liquid sheet jets

We present a design and experimental study of microfluidic converging nozzles which creates a stable liquid sheet jet. The sheet jets formed by the nozzles can be varied between order 10 μm to submicron thicknesses (a measured minimum thickness of 560 nm). A parametric study of the jet structure was performed here including 51-fold variation of Reynolds number, 20-fold variation of Weber number, 89-fold variation of capillary number, and 12-fold variation of nozzle exit aspect ratio. These studies benefited from variation of working liquids, nozzle geometry, 10-fold variation of flow rate, and 7.1-fold variation of key length scales. Navier-Stokes simulations of internal fluid flow were also performed to identify key physical phenomena. These studies were used to propose and test physical scaling theories for jet thickness, length, and width of the primary sheet. The scaling theories are also informed by classic studies of colliding jets with similar flow structures. For sheet thickness, we present two scaling approaches: one relying on internal fluid flow calculations and the other based solely on nozzle geometry. For sheet length and width, scaling theories are presented based on the nozzle geometry and essential dimensionless flow parameters. The scalings do not require numerical simulation of external flow and exhibit efficient collapse across the parameter space. Together, the fabrication method and scaling theories provide a clear path to the rapid and efficient design of liquid sheet jets.

36 MATERIALS SCIENCE↗

Self-Pressurization and Spray Cooling Simulations of the Multipurpose Hydrogen Test Bed (MHTB) Ground-Based Experiment

This paper presents a CFD (computational fluid dynamics) model for simulating the self-pressurization of a large scale liquid hydrogen storage tank. In this model, the kinetics-based Schrage equation is used to account for the evaporative and condensing interfacial mass flows. Laminar and turbulent approaches to modeling natural convection in the tank and heat and mass transfer at the interface are compared. The flow, temperature, and interfacial mass fluxes predicted by these two approaches during tank self-pressurization are compared against each other. The ullage pressure and vapor temperature evolutions are also compared against experimental data obtained from the MHTB (Multipuprpose Hydrogen Test Bed) self-pressurization experiment. A CFD model for cooling cryogenic storage tanks by spraying cold liquid in the ullage is also presented. The Euler- Lagrange approach is utilized for tracking the spray droplets and for modeling interaction between the droplets and the continuous phase (ullage). The spray model is coupled with the VOF (volume of fluid) model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. Droplet ullage heat and mass transfer are modeled. The flow, temperature, and interfacial mass flux predicted by the model are presented. The ullage pressure is compared with experimental data obtained from the MHTB spray bar mixing experiment. The results of the models with only droplet/ullage heat transfer and with heat and mass transfer between the droplets and ullage are compared.

cryogenic fluid storage↗

The influence of interfacial slip on two-phase flow in rough pores

The migration and trapping of supercritical CO 2 (scCO 2 ) in geologic carbon storage is strongly dependent on the geometry and wettability of the pore network in the reservoir rock. During displacement, resident fluids may become trapped in the pits of a rough pore surface forming an immiscible two-phase fluid interface with the invading fluid, allowing apparent slip flow at this interface. We present a two-phase fluid dynamics model, including interfacial tension, to characterize the impact of mineral surface roughness on this slip flow. We show that the slip flow can be cast in more familiar terms as a contact-angle (wettability)-dependent effective permeability to the invading fluid, a nondimensional measurement which relates the interfacial slip to the pore geometry. The analysis shows the surface roughness-induced slip flow can effectively increase or decrease this effective permeability, depending on the wettability and roughness of the mineral surfaces. Configurations of the pore geometry where interfacial slip has a tangible influence on permeability have been identified. The results suggest that for large roughness features, permeability to CO 2 may be enhanced by approximately 30% during drainage, while the permeability to brine during reimbibition may be enhanced or diminished by 60%, depending on the contact angle with the mineral surfaces and degrees of roughness. For smaller roughness features, the changes in permeability through interfacial slip are small. As a result, a much larger range of effective permeabilities are suggested for general fluid pairs and contact angles, including occlusion of the pore by the trapped phase.

54 ENVIRONMENTAL SCIENCES↗

Effects of Heating Configuration and Operating Parameters on Heat Transfer and Interfacial Physics of Microgravity Flow Boiling With Subcooled Inlet Conditions –Experiments Onboard the International Space Station

This study is part of the Flow Boiling and Condensation Experiment (FBCE), a collaborative effort between the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center. The FBCE fitted with the Flow Boiling Module (FBM) was launched to the International Space Station (ISS) in August 2021 and experiments were successfully performed from February to July 2022 to amass a large microgravity-flow-boiling database. This study is focused on heat transfer and flow visualization of microgravity flow boiling of n-Perfluorohexane in a rectangular channel of 5.0 mm height, 2.5 mm width (heated), and 114.6 mm length, with subcooled inlet conditions. High-speed-video photography is utilized to present flow patterns and temporal interfacial behavior. Heat transfer results are presented in the form of flow boiling curves and both parametric curves and streamwise profiles of wall temperature and heat transfer coefficient. Firstly, the parametric effects of mass velocity (199.4 – 3200.0 kg/m 2 s), inlet subcooling (0.2 – 46.0°C), and inlet pressure (124.2 – 176.7 kPa), on the aforementioned aspects are assessed for double-sided heating to establish them for a microgravity environment. Of these three parameters, mass velocity and inlet subcooling mostly determine the microgravity flow boiling behavior, while inlet pressure plays an insignificant role. Flow patterns for double-sided heating are more complex than those for single-sided heating due to interaction between the two vapor layers. Vapor interaction is minimized at high subcoolings and high mass velocities due to strong condensation offered by the subcooled bulk liquid layer separating them. Despite the different flow patterns, both single- and double-sided heating generally result in similar parametric trends and local heat transfer coefficients for similar operating conditions. Flow instabilities manifest as temporal flow anomalies and temperature oscillations, and their severity increases with increasing boiling number. Secondly, the effects of heating configuration are analyzed by comparing and contrasting several aspects of single- and double-sided heating data. The heat fluxes at which onset of nucleate boiling degradation (ONBD) and critical heat flux (CHF) occur are distinctly different for single- and double-sided heating. There exists a threshold inlet subcooling demarcating the dominance of flow acceleration and condensation effects in vapor removal from the near-wall region and replenishment of fresh liquid for boiling. Above the threshold, condensation from the near-wall region is dominant and single-sided heating yields higher heat fluxes, and below it, acceleration is dominant and double-sided yields higher heat fluxes. At mass velocity in the range of 200 – 2400 kg/m 2 s, the threshold inlet subcooling lies in the approximate range of 20 – 30°C (corresponding inlet quality of roughly -0.40 – -0.20).

Microgravity↗

High-speed impact of micron-sized diesel drop trains—Splashing dynamics, secondary droplet formation, and effects of pre-existing film thickness

This work investigates surface impingement of monodispersed diesel drop trains using computational simulations. The three-dimensional simulations include high-speed impact of micrometer-sized fuel drops onto initially dry and wetted stainless steel substrates. The drop size and impact velocity are representative of fuel injection conditions in internal combustion engines (ICEs). The drop trains serve as a simplified representation of fuel spray. To accurately capture the film that naturally develops on initially dry substrates, a dynamic diesel-stainless steel contact angle model was developed using experiments of single drop impact under ICE representative temperature. Simulations are presented for a highly splashing case and the effects of a pre-existing film on splashing dynamics were investigated, including the temporal evolution of splashed mass and film thickness. It was concluded that for thin films, the effect of pre-existing film thickness is less significant than in single drop impingement. Secondary droplet characterization was performed on simulation results, leading to instantaneous and time-averaged distributions of secondary droplet size, velocity magnitude, and trajectory angle. It was found that for each drop impingement, approximately 58% of the splashed mass is from the impinging drop itself, while the remainder of the splashed mass is composed of film liquid. From a high resolution case, details of secondary droplet formation are observed and three distinct phases of secondary droplet formation are identified. The detailed analysis of drop train impingement under engine-relevant conditions serves as a first step toward a robust understanding of fuel impingement and the development of cleaner and more efficient ICEs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic Dynamics of Multi‐Interfacial Migration and Transformations

Redox-induced interconversions of metal oxidation states typically result in multiple phase boundaries that separate chemically and structurally distinct oxides and suboxides. Directly probing such multi-interfacial reactions is challenging because of the difficulty in simultaneously resolving the multiple reaction fronts at the atomic scale. Using the example of CuO reduction in H 2 gas, a reaction pathway of CuO → monoclinic m-Cu 4 O 3 → Cu 2 O is demonstrated and identifies interfacial reaction fronts at the atomic scale, where the Cu 2 O/m-Cu 4 O 3 interface shows a diffuse-type interfacial transformation; while the lateral flow of interfacial ledges appears to control the m-Cu 4 O 3 /CuO transformation. Together with atomistic modeling, it is shown that such a multi-interface transformation results from the surface-reaction-induced formation of oxygen vacancies that diffuse into deeper atomic layers, thereby resulting in the formation of the lower oxides of Cu 2 O and m-Cu 4 O 3 , and activate the interfacial transformations. In conclusion, these results demonstrate the lively dynamics at the reaction fronts of the multiple interfaces and have substantial implications for controlling the microstructure and interphase boundaries by coupling the interplay between the surface reaction dynamics and the resulting mass transport and phase evolution in the subsurface and bulk.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interfacial shear modeling and flow predictions for internal film condesation flows

Internal flow of pure vapor experiencing film condesation on the walls of a straight duct is studied. The commonly occuring case of turbulent (or laminar) vapor flow in the core and laminar flow of the liquid condensate-with or without waves on the interface-is emphasized. We propose and implement a new first principle methodolgy which model interfacial shear with the help of reliable experimental data on heat transfer rates. Other details of the flow are predicted with the help of this model. These predictions are shown to be in agreement with relevant experimental data. Correlations for film thickness and heat transfer rates are also given.

Narain, A.↗

CFD Modeling of the Multipurpose Hydrogen Test Bed (MHTB) Self-Pressurization and Spray Bar Mixing Experiments in Normal Gravity: Effect of the Accommodation Coefficient on the Tank Pressure

A CFD model for simulating the self-pressurization of a large scale liquid hydrogen storage tank is utilized in this paper to model the MHTB self-pressurization experiment. The kinetics-based Schrage equation is used to account for the evaporative and condensi ng interfacial mass flows in this model. The effect of the accommodation coefficient for calculating the interfacial mass transfer rate on the tank pressure during tank selfpressurization is studied. The values of the accommodation coefficient which were considered in this study vary from 1.0e-3 to 1.0e-1 for the explicit VOF model and from 1.0e-4 to 1.0e-3 for the implicit VOF model. The ullage pressure evolutions are compared against experimental data. A CFD model for controlling pressure in cryogenic storage tanks by spraying cold liquid into the ullage is also presented. The Euler-Lagrange approach is utilized for tracking the spray droplets and for modeling the interaction between the droplets and the continuous phase (ullage). The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. Droplet-ullage heat and mass transfer are modeled. The flow, temperature, and interfacial mass flux, as well as droplets trajectories, size distribution and temperatures predicted by the model are presented. The ul lage pressure and vapor temperature evolutions are compared with experimental data obtained from the MHTB spray bar mixing experiment. The effect of the accommodation coefficient for calculating the interfacial and droplet mass transfer rates on the tank pressure during mixing of the vapor using spray is studied. The values used for the accommodation coefficient at the interface vary from 1.0e-5 to 1.0e-2. The droplet accommodation coefficient values vary from 2.0e-6 to 1.0e-4.

cryogenic fluid storage↗

Quasistatic fluid-fluid displacement in porous media: Invasion-percolation through a wetting transition

We study the influence of wettability on the morphology of fluid-fluid displacement through analog porous media in the limit of vanishing flow rates. We introduce an invasion-percolation model that considers cooperative pore filling and corner-flow mechanisms and captures interface motion at the pore scale for all quasistatic flow regimes between strong drainage and strong imbibition. We validate the method against recent experimental observations of wetting transition in microfluidic cells patterned with circular posts and we use it to explore the sensitivity of fluid invasion to wettability heterogeneity, post spacing, and post height. Furthermore, our model therefore extends the Cieplak-Robbins description of quasistatic fluid invasion by reproducing the wetting transition in strong imbibition, a feature that requires incorporating three-dimensional effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dislocation-induced stop-and-go kinetics of interfacial transformations

Most engineering materials are based on multiphase microstructures produced either through the control of phase equilibria or by the fabrication of different materials as in thin-film processing. In both processes, the microstructure relaxes towards equilibrium by mismatch dislocations (or geometric misfit dislocations) across the heterophase interfaces (1-5) . Despite their ubiquitous presence, directly probing the dynamic action of mismatch dislocations has been unachievable owing to their buried nature. In this work, using the interfacial transformation of copper oxide to copper as an example, we demonstrate the role of mismatch dislocations in modulating oxide-to-metal interfacial transformations in an intermittent manner, by which the lateral flow of interfacial ledges is pinned at the core of mismatch dislocations until the dislocation climbs to the new oxide/metal interface location. Together with atomistic calculations, we identify that the pinning effect is associated with the non-local transport of metal atoms to fill vacancies at the dislocation core. These results provide mechanistic insight into solid-solid interfacial transformations and have substantial implications for utilizing structural defects at buried interfaces to modulate mass transport and transformation kinetics.

25 ENERGY STORAGE↗

Microgravity Flow Boiling Experiments With Liquid-Vapor Mixture Inlet Onboard the International Space Station

This article is part of a series of studies culminating from the multi-objective Flow Boiling and Condensation Experiment (FBCE) onboard the International Space Station, which utilized the Flow Boiling Module (FBM) for experiments between February and July 2022. This study investigates microgravity flow boiling of n-Perfluorohexane with liquid-vapor mixture (two-phase) inlet conditions to the FBM with either one or two opposite walls heated. The FBM’s channel has a rectangular cross-sectional area of 5.0 × 2.5 mm 2 and a heated length of 114.6 mm. Key parameters of interest include mass velocity (180 – 2400 kg/m 2 s), inlet quality (-0.01 – 0.87), inlet pressure (120 – 200 kPa), and heat flux (1.8 W/cm 2 to critical heat flux), and a large database is amassed. The flow is visualized via a high-speed video camera and photographs are recorded at each heating increment to assess the periodic flow patterns within the channel and the near-wall interfacial behavior. Flow patterns are complex and mainly characterized by high- and low-density fronts alternately traversing the channel to yield high- and low-density-dominant periods of boiling. At all operating conditions, high-density fronts are faster during high-density-dominant periods. At low inlet qualities, the flow is annular near the channel inlet with a central vapor core surrounded by an annular liquid layer. Each high-density front having a high liquid fraction leaves a thin liquid layer sheared onto the heated walls. Boiling occurs within the liquid layer and a vapor layer is formed next to the heated wall. Inlet quality and mass velocity most dictate the overall flow patterns followed by heating configuration, and to a much lesser extent, heat flux and inlet pressure. Heat transfer characteristics are assessed via averaged boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric curves of local and averaged heat transfer coefficients. Inlet pressure has an insignificant effect on heat transfer. At similar operating conditions, both the heating configurations yield similar trends and values of heat transfer coefficient and critical heat flux (CHF, slightly higher for single-sided) even though double-sided heating adds twice the heat to the fluid and doubly raises local quality. The heat fluxes required for both onset of nucleate boiling degradation and CHF are larger at high mass velocities and low inlet qualities. For a fixed inlet quality, high mass velocities yield higher average heat transfer coefficients at both lower and higher heat fluxes, while the nucleate boiling regime at intermediate heat fluxes is unaffected. For a fixed mass velocity, higher inlet qualities yield higher and lower average heat transfer coefficients at lower and higher heat fluxes, respectively.

Microgravity↗

Evaluation of interfacial area transport models for horizontal bubbly flow

This paper presents evaluation results of interfacial area transport equation (IATE) for horizontal air-water bubbly flow. The steady-state one-dimensional, one-group IATE for adiabatic air-water bubbly flow developed by Talley [1] is employed in the current evaluation study. The models evaluated include: (a) drift-flux-based closure relations for void-weighted bubble velocity and void fraction; (b) frictional pressure drop model based on the Lockhart-Martinelli approach; (c) bubble interaction mechanisms; and (d) covariance associated with asymmetric bubble distribution in horizontal two-phase flow. In order to evaluate the models, a local two-phase flow database obtained by the four-sensor conductivity probe in fourteen different test conditions is employed, which covers a wide range of flow conditions in horizontal bubbly flow regime, with superficial liquid and gas velocities ranging from 3.50-6.00 m/s and 0.09- 1.00 m/s, respectively. It is demonstrated that both the void weighted bubble velocity and void fraction are predicted well with an average percent difference of ±2.7%. The fictional pressure loss can be predicted with an average percent difference of ±1.12%. The covariance parameters calculated from the modeling approach generally compare well with those calculated from experimental data within ±20% difference. It is found that the IATE generally predicts the measured interfacial area concentration with an average percent difference of ±5.7%. Furthermore, the effect of liquid velocity on individual bubble interaction mechanisms is investigated. It is found that both the contributions of random collision and turbulent impact decrease as liquid velocity decreases. (authors)

42 ENGINEERING↗

Hydrodynamics of countercurrent flows in a structured packed column: effects of initial wetting and dynamic contact angle

The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.

structured packings, dynamic contact angle, interf↗

Experimental Investigation of Flow Orientation Effects on Cryogenic Flow Boiling

Cryogenic flow boiling physics is of paramount importance for future cryogenic space applications employing Cryogenic Fluid Management (CFM) technologies. This experimental study investigates the two-phase flow and heat transfer performance of LN 2 flow boiling across five distinct flow orientations: vertical upflow, vertical downflow, horizontal flow, 45° inclined upflow, and 45° inclined downflow. The study employed the steady- state heating method within a circular heated tube featuring an 8.5-mm inner diameter and a 680-mm heated length. High-speed video recordings were utilized to capture two-phase flow patterns and interfacial behaviors across various flow orientations. The experiments covered a wide range of operating conditions, including mass velocities ranging from 351.80 to 1572.77 kg/m 2 s and inlet pressures from 297.14 to 1032.97 kPa, primarily with near-saturated inlet subcooling. Distinct two-phase flow patterns and regime transitions were identified for each flow orientation. Symmetrical flow patterns were evident in vertical orientations, whereas non-vertical orientations exhibited asymmetric flow stratifications, primarily influenced by the buoyancy force in a terrestrial gravity environment. Bubble dynamic parameters were quantified, and bubble collision and dispersion phenomena were visualized. Analyzing heat transfer performance based on local flow boiling curves and variations in heat transfer coefficients (HTCs), it was observed that vertical upflow demonstrated the most enhanced heat transfer performance, while vertical downflow exhibited the lowest. As mass velocity exceeded 830 kg/ m 2 s, the differences in heat transfer among orientations became less distinct, emphasizing the role of flow inertia in mitigating the influence of flow orientation. A direct comparison of microgravity HTC data from a recent study by the authors against the 1-𝘨 e HTC data indicated enhanced heat transfer performance in microgravity for flow orientation configurations in terrestrial gravity. However, this enhancement progressively diminished as the heat flux increased. Distinct HTC trends were observed as mass velocity increased for different flow orientations and gravity levels.

Cryogens↗