Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Second Target Station Project: LANSCE WNR Target 2 (Blue Room) Experiment 2022

The Second Target Station (STS) at SNS will address emerging scientific challenges by providing a source of intense, cold neutrons to instruments optimized for this source, using rotating, tungsten target blocks. The STS target will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 108 beam pulses per lifetime. As an R&D activity, the LANSCE WNR Target 2 (blue room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60% of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. Both the LANSCE Proton Storage Ring (PSR) and SNS are short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in < 1 microsecond pulse duration.

43 PARTICLE ACCELERATORS↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2025 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2025 edition includes updates to the appendices to describe the current instrumentation of the NREL-SRRL.

14 SOLAR ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory (BMS and RMS SOP)

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyze the real-time performance of the optimized fiber-PTR instrument

An instrument to perform in-reactor, real-time thermal property measurements of nuclear fuels and materials was recently designed, optimized, and tested at Massachusetts Institute of Technology Research Reactor. It was the second insertion experiments of a total of two rounds. Here we report the collection and analysis of the real-time captured thermal diffusivity data on the preloaded SiC. With the optimized design, the instrument temperature had been successfully raised as we expected. Only one probe (the top one) returned real-time thermal diffusivity in a time span of approximately two days. Measured thermal diffusivity of the preloaded SiC was significantly lower than the literature value at the same temperature, indicating a significant influence from the irradiation induced microstructure damage. Meanwhile, the real-time thermal diffusivity value continuously reduced with time, indicating the dynamic microstructure evolution. The possible reasons of the probes that did not return data were hypothesized. The further optimization of the instrument with the objective to improve the measurement accuracy and instrument survivability is also discussed.

36 MATERIALS SCIENCE↗

Advanced Method Optimization for Sampling and Analysis Instrumentation

This work presents a generalized approach for analytical method optimization that branches the gap between techniques historically employed and accurate modern optimization techniques suitable for various applications. The novelty of the described strategy is the utilization of multivariate, multiobjective optimization with Karush-Kuhn-Tucker conditions to bound the optimization space to solutions within the physical limitations of instrumentation. Briefly, the basic steps outlined in this paper are to (1) determine the objective(s) that should be maximized or minimized based on the goals of the analytical application, (2) conduct a screening experiment, (3) perform ANOVA to determine the parameters which have a statistically significant effect on the objective, (4) conduct an experiment (e.g., Box-Behnken design) to collect data for fitting the objective equation, and (5) determine the physical constraints of the parameters and solve the Lagrangian to determine the optimal method parameters. A broad approach to optimization target selection allows for robust method tuning to develop improved data sets amenable for chemometrics and machine learning algorithm development. Gas chromatography-mass spectrometry was selected as a use case due to its broad use across scientific fields and time-consuming method development involving numerous parameters. In conclusion, this strategy can reduce the cost of research, improve data quality, and enable the rapid development of new analytical technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and pre-flight performance of SPIDER 280 GHz receivers

In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for the second Antarctic flight will incorporate three new 280 GHz receivers alongside three refurbished 95- and 150 GHz receivers from Spider's first flight. In this work we discuss the design and characterization of these new receivers, which employ over 1500 feedhorn-coupled transition-edge sensors. We describe pre-flight laboratory measurements of detector properties, and the optical performance of completed receivers. These receivers will map a wide area of the sky at 280 GHz, providing new information on polarized Galactic dust emission that will help to separate it from the cosmological signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A science-driven approach to optimize the design for a biological small-angle neutron scattering instrument

Biological small-angle neutron scattering (SANS) instruments facilitate critical analysis of the structure and dynamics of complex biological systems. However, with the growth of experimental demands and the advances in optical systems design, a new neutron optical concept is necessary to overcome the limitations of current instruments. This work presents an approach to include experimental objectives ( i.e. the science to be supported by a specific neutron scattering instrument) in the optimization of the neutron optical concept. The approach for a proposed SANS instrument at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory, USA, is presented here. Further, the instrument is simulated with the McStas software package. The optimization process is driven by an evolutionary algorithm using McStas output data, which are processed to calculate an objective function designed to quantify the expected performance of the simulated neutron optical configuration for the intended purpose. Each McStas simulation covers the complete instrument, from source to detector, including realistic sample scattering functions. This approach effectively navigates a high-dimensional parameter space that is otherwise intractable; it allows the design of next-generation SANS instruments to address specific scientific cases and has the potential to increase instrument performance compared with traditional design approaches.

47 OTHER INSTRUMENTATION↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPECTER: an instrument concept for CMB spectral distortion measurements with enhanced sensitivity

Deviations of the cosmic microwave background (CMB) energy spectrum from a perfect blackbody uniquely probe a wide range of physics, ranging from fundamental physics in the primordial Universe (μ-distortion) to late-time baryonic feedback processes (y-distortion). While the y-distortion can be detected with a moderate increase in sensitivity over that of COBE/FIRAS, the ΛCDM-predicted μ-distortion is roughly two orders of magnitude smaller and requires substantial improvements, with foregrounds presenting a serious obstacle. Within the standard model, the dominant contribution to μ arises from energy injected via Silk damping, yielding sensitivity to the primordial power spectrum at wavenumbers k ≈ 1-10 4 Mpc -1 . Here, we present a new instrument concept, SPECTER, with the goal of robustly detecting μ. The instrument technology is similar to that of LiteBIRD, but with an absolute temperature calibration system. Using a Fisher approach, we optimize the instrument's configuration to target μ while marginalizing over foreground contaminants. Unlike Fourier-transform-spectrometer-based designs, the specific bands and their individual sensitivities can be independently set in this instrument, allowing significant flexibility. We forecast SPECTER to observe the ΛCDM-predicted μ-distortion at ≈ 5σ (10σ) assuming an observation time of 1 (4) year(s) (corresponding to mission duration of 2 (8) years), after foreground marginalization. Our optimized configuration includes 16 bands spanning 1–2000 GHz with ∼degree-scale angular resolution at ∼ 150 GHz and 1100 total detectors. SPECTER will additionally measure the y-distortion at sub-percent precision and its relativistic correction at percent-level precision, yielding tight constraints on the total thermal energy and mean temperature of ionized gas.

CMBR experiments↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CMB-S4 Instrument Modeling and Development for CMB-S4

During this thirteen month award, we focused on two main tasks relevant to the development of the CMB-S4 project: (1) The refinement of sensitivity models and use of those to optimize the instrument design, and (2) the final development and testing a cryogenic blackbody calibrator prototype, of which we then produced three copies for CMB-S4's detector testing systems at FNAL, SLAC and UIUC.

47 OTHER INSTRUMENTATION↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Raman Spectroscopy Based On-Line, Real-Time Monitoring to Reduce Composition Uncertainties: Enhanced sensitivity through optimization of Raman Parameters

Optical spectroscopy-based on-line monitoring of Hanford processing streams can enable real-time characterization of chemical composition of process streams and batches, ultimately enabling and enhancing process control. It can provide immediate feedback on process conditions and has the potential to reduce the needed number of grab sample collections, thereby reducing times and costs associated with laboratory processing. Here we discuss the utilization of Raman spectroscopy to quantify multiple target analytes that are common within Hanford tanks and waste processing streams. Analytes include: nitrate, nitrite, carbonate, chromate, sulfate, phosphate, hydroxide, oxalate, ammonia, and aluminate. Most notably in this work, Raman applications to low-concentration streams are explored and optimized. Raman instrument specifications are compared; specifically, the impact of utilizing three different Raman excitation wavelengths, 405, 532, and 671 nm, is discussed. Also, Raman data collection parameters such as collection time and spectral averaging are measured and discussed. Finally, optical libraries of chemical targets were collected using optimized collection parameters and chemometric models were built to automate quantification of chemical targets. These models were validated through application to simulants and real Hanford process samples. Chemometric models performed well on both training and validation sets, suggesting these approaches can be successfully applied to on-line and real-time monitoring of low concentration Hanford processing streams. The use of the combine Raman wave lengths with the enhanced chemometric models for the low concentration streams significantly improved the chemical detection levels and significantly reduced uncertainties of those measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotope-Resolved Electron Energy Loss Spectroscopy in a Monochromated Scanning Transmission Electron Microscope

The development and implementation of high-stability monochromators in state-of-the-art aberration-corrected scanning transmission electron microscopes has enabled materials characterization with an energy resolution as good as 3 meV. This allows the vibrational modes, which would otherwise be obscured by the energy spread of the electron beam, to be probed with very high precision in molecular materials. Since the vibrational energies depend on the weight of the atomic nuclei, vibrational spectroscopy can distinguish isotopes whose only difference lies in their neutron content. This opens up isotopic analysis and mapping in transmission electron microscopy as two important new research areas. In this paper, we review the monochromated electron energy loss spectroscopy (EELS) instrumentation, discuss optimal methods for probing beam-sensitive materials without destroying them, and review key nanoscale isotope-resolved results.

47 OTHER INSTRUMENTATION↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Quantification of Hydrogen Isotopes Utilizing Raman Spectroscopy Paired with Chemometric Analysis for Application across Multiple Systems

On-line and real-time analysis of a chemical process is a major analytical challenge that can drastically change the way the chemical industry or chemical research operates. With in situ analyses, new and powerful understanding of chemistry can be gained; however, building robust tools for long-term monitoring faces many challenges that include compensating for instrument drift, instrument replacement, and sensor or probe replacement. Accounting for these changes by recollecting calibration data and rebuilding quantification models can be costly and time consuming. Here, in this study, methods to overcome these challenges are demonstrated with an application of Raman spectroscopy to monitoring hydrogen isotopes with varied speciation within dynamic gas streams. Specifically, chemical data science tools such as chemometric modeling are leveraged along with several examples of calibration transfer approaches. Furthermore, the optimization of instrument and sensors cell parameters for targeted gas phase analyses is discussed. While the particular focus on hydrogen is highly beneficial within the nuclear energy sector, mechanisms built and demonstrated here are widely applicable to optical spectroscopy monitoring in numerous other chemical systems that can be leveraged in other hazardous processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗