Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Injection Activity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Generative Thermodynamic Computing

Here, we introduce a generative modeling framework for thermodynamic computing, in which structured data are synthesized from noise by the natural time evolution of a physical system governed by Langevin dynamics. While conventional diffusion models use neural networks to perform denoising, here the information needed to generate structure from noise is encoded by the dynamics of a thermodynamic system. Training proceeds by maximizing the probability with which the computer generates the reverse of a noising trajectory, which ensures that the computer generates data with minimal heat emission. We demonstrate this framework within a digital simulation of a thermodynamic computer. If realized in analog hardware, such a system would function as a generative model that produces structured samples without the need for artificially injected noise or active control of denoising.

Whitelam, Stephen [Lawrence Berkeley National Labo

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

black start

Southwest Regional Partnership on Carbon Sequestration: Phase III (Final Scientific/Technical Report)

The Southwest Regional Partnership on Carbon Sequestration (SWP) is one of 7 regional partnerships formed in 2003 under the U.S. Department of Energy’s (DOE) Regional Carbon Sequestration Partnerships (RCSPs) initiative. The overall purpose of the initiative was to help determine and implement the technology, infrastructure, and regulations most appropriate to promote carbon storage in different regions of the country. Covering Arizona, Colorado, New Mexico, Oklahoma, Utah, and parts of Texas, Wyoming, and Kansas, the SWP evaluated regional carbon storage and utilization potential and focused on technologies and sites that could complement the region’s strong position in energy production. The project progressed through three phases: • Phase I (2003–2005): Characterized regional geologic formations and CO 2 sources, assessed sequestration potential, and identified pilot test sites. • Phase II (2005–2013): Conducted small-scale field tests to validate sequestration methods, including geologic and terrestrial projects. • Phase III (2008–2022): Demonstrated large-scale CO 2 injection at a commercial oil field to test monitoring, verification, and long-term storage strategies. This report covers Phase III. The final project site, the Farnsworth Unit (FWU) in Texas, provided real-world testing of reservoir characterization, monitoring, and risk evaluation tools and processes that could be used in any commercial scale carbon capture, utilization, and storage (CCUS) project. Extensive data collection and analysis helped refine best practices for reservoir characterization, injection monitoring, and storage verification. The SWP contributed to national databases, DOE best practice manuals, and regional geological assessments to support future sequestration efforts. Key lessons learned include the importance of robust data management, strategic site selection, regulatory navigation, and effective industry collaboration. The project’s findings will inform ongoing and future carbon storage initiatives. Task 1 (Regional Characterization) • The SWP continued to participate in national outreach efforts and NATCARB. • The SWP evaluated multiple potential sites before selecting the FWU as the primary field test location. Task 2 (Public Outreach and Education) • The SWP contributed to national databases, DOE best practice manuals, and regional geological assessments to support future sequestration efforts. Task 3 (Permitting and Regulatory Compliance) • The SWP ensured compliance with federal and state regulations, including National Environmental Policy Act (NEPA) requirements. • The SWP obtained all necessary permits for drilling, injection, and monitoring activities. Task 4 (Site Characterization and Planning) • The SWP developed work plans for four key activities: characterization, simulation, monitoring and verification, and risk evaluation. • The SWP collected and synthesized legacy data from multiple sources to build initial static geological models and dynamic reservoir models demonstrating project feasibility. • The SWP conducted an initial risk evaluation and developed mitigation plans. Task 5 (Field Operations and Data Collection) • The SWP drilled, logged, and cored three characterization wells to gather critical subsurface data. • The SWP conducted multiple geophysical surveys, including 3D seismic, crosswell seismic, and vertical seismic profiling, to improve reservoir characterization. Task 6 (Monitoring and Verification) • The SWP performed extensive geological characterization using data from characterization wells and seismic surveys. • The SWP established a surface monitoring network to track CO 2 flux in soil gas, groundwater chemistry, and near-surface atmospheric CO 2 levels. • The SWP built and refined reservoir models to study the effects of relative permeability on simulation behavior and improve calibration with experimental data. Task 7 (Risk Assessment and Model Refinement) • The SWP conducted multiple studies to evaluate reservoir integrity, predict CO 2 plume behavior and improve predictive modeling capabilities. • The SWP refined geological models and used them to enhance the accuracy of simulation models. • The SWP continued quantitative risk assessment of top-ranked risks and strengthened the link between qualitative and quantitative risk methodologies.

02 PETROLEUM

Summary of Potential Incidents and Consequences from Carbon Dioxide Pipeline and Storage Systems Construction and Operation

This document provides a high-level summary of the potential human and environmental impacts associated with carbon dioxide (CO 2 ) pipeline transport, injection, and storage activities. It also reviews lessons learned from natural and industrial analogs of CO 2 storage as well as case studies of notable accidental CO 2 releases. The analysis is structured into several key sections, each addressing specific resource impacts and potential consequences.

54 ENVIRONMENTAL SCIENCES

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance

Active Divertor Heat Flux Control using Impurity Powder Dropper

Divertor plasma-facing components (PFCs) in a tokamak are typically designed to withstand average steady-state heat loads of about 5–10 MW/m 2 , a limit that applies to both solid and liquid lithium (LL) PFCs. Exceeding these design values can result in surface damage to tungsten PFCs or excessive lithium (Li) evaporation in liquid lithium divertor (LLD) PFCs. Since exceeding the divertor heat load limits has serious consequences, it is therefore prudent to develop a tool to reduce the divertor heat load and bring the heat load to within the design limit without affecting the plasma performance. Active low Z impurity injection such as Li has been suggested as a potential solution to mitigate excess heat flux as suggested previously, given that non-coronal radiation can be quite large ~ 20–30 MJ per mole of injected Li. Li is considered desirable for reducing the edge neutral recycling helping to improve plasma energy confinement. In this paper, we model the Impurity Power Dropper (IPD) to investigate its potential of divertor heat flux control. The IPD is typically located at the top of the tokamak device and uses a vertical drift tube of a few meters. In the 2 m drift tube case, the IPD powder is accelerated to ~ 6 m/sec before reaching the plasma with the upper divertor configuration, matching the condition for the in-board side pellet injection case. By modeling the IPD geometry we determined the IPD powder deposition profile, and thus the non-coronal radiation and ionization profiles in time as well. From the enhanced radiation power loss, it is therefore possible to reduce the divertor heat load using the divertor simulation code. In conclusion, the IPD divertor heat flux control can be tested in the facilities with IPD including ST-40, DIII-D, EAST, WEST and NSTX-U.

Active lithium injection

Chemical Activation of Frontal Ring-Opening Metathesis Polymerization

In this study, we present an innovative approach to frontal ring-opening metathesis polymerization (FROMP) through chemical activation. By locally concentrating Grubbs-type initiators, we accelerate exothermic polymerization at the activation site. Sufficient thermal energy initiates a polymerization front that travels through the remainder of the sample even with reduced initiator concentrations in the bulk resin. Initiation location and timing are controlled by adjusting the initiator reactivity, the properties of the transport solvent, and the air–resin interface. Our technique enables multipoint front activation, either through synchronized injection or by timing the relative reactivity of various initiators. This accessible method of chemical activation enables on-demand production of polymer and composite materials using only the thermal energy generated by the reaction, removing the need for external power sources and enabling deployment in remote or infrastructure-limited environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Microphysics regimes due to haze–cloud interactions: cloud oscillation and cloud collapse

Abstract. It is known that aqueous haze particles can be activated into cloud droplets in a supersaturated environment. However, haze–cloud interactions have not been fully explored, partly because haze particles are not represented in most cloud-resolving models. Here, we conduct a series of large-eddy simulations (LESs) of a cloud in a convection chamber using a haze-capable Eulerian-based bin microphysics scheme to explore haze–cloud interactions over a wide range of aerosol injection rates. Results show that the cloud is in a slow microphysics regime at low aerosol injection rates, where the cloud responds slowly to an environmental change and droplet deactivation is negligible. The cloud is in a fast microphysics regime at moderate aerosol injection rates, where the cloud responds quickly to an environmental change and haze–cloud interactions are important. More interestingly, two more microphysics regimes are observed at high aerosol injection rates due to haze–cloud interactions. Cloud oscillation is driven by the oscillation of the mean supersaturation around the critical supersaturation of aerosol due to haze–cloud interactions. Cloud collapse happens under weaker forcing of supersaturation where the chamber transfers cloud droplets to haze particles efficiently, leading to a significant decrease (collapse) in cloud droplet number concentration. One special case of cloud collapse is the haze-only regime. It occurs at extremely high aerosol injection rates, where droplet activation is inhibited, and the sedimentation of haze particles is balanced by the aerosol injection rate. Our results suggest that haze particles and their interactions with cloud droplets should be considered, especially in polluted conditions.

54 ENVIRONMENTAL SCIENCES

Phase II Field Demonstration at Lansing Smith Generating Plant, Southport, Florida (Final Report)

The Final Technical Report: Field Test Design and Pressure Management Strategies for Phase II Field Demonstration of Optimal Pressure Control, Plume Management, and Produced Water Strategies presents the culmination of multi-year efforts under the U.S. Department of Energy’s Brine Extraction and Storage Test (BEST) program, led by EPRI in partnership with Gulf Power at the Plant Smith site near Panama City, Florida. The project was designed to evaluate and demonstrate the technical feasibility of managing subsurface pressures and fluid movement associated with large-scale CO₂ injection, using low-salinity water as a proxy fluid. Through a combination of field injection testing, reservoir modeling, and optimization studies, the research team developed and refined active and passive brine extraction strategies aimed at controlling injection-induced pressure buildup, mitigating risks of fault activation, and managing plume migration. The field demonstration incorporated a new injection well (TIW-2), a new monitoring/extraction well (TEMW-A), and an existing well (TIW-1) repurposed for passive pressure relief. Complementary geophysical monitoring was designed to track plume development and evaluate the effectiveness of pressure management strategies. The report details the integrated workflow encompassing wellfield development, regulatory permitting, model calibration, and survey design. It includes a comprehensive electromagnetic (EM) modeling and inversion study used to develop a cost-effective, time-lapse geophysical monitoring plan capable of imaging the evolving low-salinity plume within the highly saline Lower Tuscaloosa formation. Reservoir simulation results guided the design of the 17-month injection program and the timing of active extraction to maintain formation pressures below a hypothetical fault reactivation threshold. Supporting analyses evaluated potential injectivity risks related to clay fines migration and geochemical incompatibility, identifying practical mitigation measures such as salinity and pH control. The final design recommends a series of crosswell EM surveys—conducted before, during, and after injection—as the most effective and economical approach for plume imaging, supplemented by continuous downhole pressure and flow monitoring. Collectively, the study provides a field-ready framework for cost-effective pressure management and monitoring in support of future CO₂ storage projects.

01 COAL, LIGNITE, AND PEAT

In Situ Electrochemistry of Buried Interfaces in Metal Halide Perovskites: Probing Energy Bands, Halide Redox Activity, and Kinetics

Control over charge injection and extraction processes across buried interfaces is fundamental for all (opto)electronic multilayer device platforms, necessitating detailed understanding of local structural and chemical differences that promote defect formation, distort energetic band-edge alignments, and alter charge transport processes. Herein, the implementation of a low-cost electroanalytical methodologies’ tool suite is described to quantitatively characterize buried interfaces and redox reactions in printable, mixed electrical–ionic, and redox-active metal halide perovskites and a prototypical hole-transporting nickel oxide (NiO x ) thin film. The objective is to demonstrate the power of electrochemical methodologies to improve the nanoscale understanding of complex interfaces within optoelectronic devices by providing case studies on how to: i) differentiate between electronic and chemical properties in NiO x contacts; ii) measure changes in reversibility of halide redox reactions via NiO x surface states; iii) assess energy alignment and charge transport across (modified) buried interfaces; and iv) quantify defects at buried interfaces that change with modifiers and differences in perovskite processing, including increasing defect concentrations when films are slot-die-coated versus spin-cast. The collective approach addresses major challenges in understanding the precise energy landscape and interface reactivity under relevant electric fields that mimic operando conditions (away from equilibrium) and across length scales in thin film device formats.

(spectro)electrochemistry

Factors controlling injection-induced rupture of intersecting faults during geological sequestration of CO 2

This study addresses coupled multiphase fluid flow and geomechanics effects on potential fault activation associated with subsurface CO 2 injection around intersecting faults. An enhanced fault-representation model is used to capture geomechanical responses of two intersecting faults with finite length during CO 2 injection. The faults are embedded in a strike-slip stress regime of a caprock-reservoir-basement system with the faults represented by zero-thickness interfaces with adjacent finite-thickness damage zones. A sensitivity analysis is conducted to study the effect of fault permeability, slip-weakening behavior, well location relative to the orientation of faults, and well placement (the number and location of injection wells). Five metrics (pressure, CO 2 plume, shear state on the fault, as well as shear displacement and stress path at selected fault monitoring points) are selected to assess CO 2 migration and reactivation of intersecting faults. The results show that induced ruptures are favored by low permeability faults due to high pressure buildup and by slip-weakening behavior resulting from fault strength reduction. The location of one injection well relative to fault orientation determines the magnitude of changes in effective normal stress and shear stress, affecting the location of induced ruptures. Well placement (two injection wells used in the paper) dominates pressure diffusion around the intersection and tips of faults. This redistributes changes in effective normal stress caused by each injection well, influencing the spatial distribution of ruptures along faults. A larger injection volume induces far-field ruptures that are controlled by stress transfer within the injection layer. The findings presented here can provide valuable insights into engineering operations for a long-term, safe, and reliable geologic CO 2 storage.

Fault permeability

Seismic Elastic Double-Beam Characterization of Faults and Fractures for CO₂ Storage Site Selection

Site characterization for underground injection and storage of gigatonne-scale CO₂ requires reliable and cost-effective methods to detect and characterize faults and fractures and to assess their stress state and fault activation potential. This is critical, as wastewater injection and disposal have been shown to activate faults and induce earthquakes, and CO₂ leakage remains a key concern for long-term storage. In this project, we developed seismic methods to detect and characterize large-scale sedimentary and crystalline basement faults and associated small-scale fractures below conventional seismic imaging resolution using multicomponent (9C) surface seismic data. Machine learning was used to automatically interpret large-scale faults, providing key information for estimating the maximum magnitude of potential induced earthquakes. High-fidelity imaging was achieved by exploiting redundancy across multiple elastic wave modes, where independent images from different modes and frequencies cross-validate each other. We also used our nonlinear signal comparison (NLSC) method for ground roll removal, improving data quality in complex near-surface conditions. The methods were validated using field data acquired in central Montana. Results show that basement faults extend into the sedimentary section and that small-scale fractures are widespread above the basement. The inferred stress orientation is consistent with regional stress data, and the estimated maximum induced earthquake magnitude is small (Mw ~2.3). The developed workflow provides a practical approach for fault and fracture characterization and for assessing induced seismicity and leakage risk. It is directly applicable to CO₂ storage site selection and to other subsurface systems.

02 PETROLEUM

An analysis of alcohol compression ignition strategies on different engine platforms

Strategies that enable ignition of the low cetane alcohol fuels (methanol and ethanol) include intake heating (direct or via hot residual trapping), increased compression ratio (CR), multi-injection strategies, ignition enhancers, and active prechambers. The literature consistently shows alcohol compression ignition (CI) is more efficient than diesel at high loads irrespective of ignition strategy but shows contradictory results at low loads. To understand this, this work combines data from four different engine platforms ranging from a displaced volume of 0.4 to 2.1 L/cyl. using different alcohol CI ignition strategies. Using modeling to support experimental analysis, alcohol-specific efficiency penalties are highlighted to inform alcohol combustion system development. The alcohols’ lower energy density means more fuel must be injected near top dead center to achieve a given load, increasing the relative penalty of sensible/latent heating. Pilot injections help reduce this penalty. Intake heating incurs both a heat transfer penalty and a thermodynamic penalty due to a reduced ratio of specific heats during compression. A strategy that combines elevated CR, large pilot injections, and ignition enhancers can avoid this penalty. Alternatively, a prechamber strategy can achieve this without changing the CR, nor needing ignition enhancers in the fuel. At low loads, diesel burns in a partially premixed mode characterized by high burn rates and low heat losses, reducing alcohol-specific combustion benefits. Alcohol CI on the light-duty platform showed abnormally high heat transfer over diesel compared to other platforms, favoring a more premixed/partially premixed strategy despite a combustion efficiency tradeoff.

33 ADVANCED PROPULSION SYSTEMS

Modeling the effect of MHD activity on runaway electron generation during SPARC disruptions

Magnetohydrodynamic (MHD) instabilities and runaway electrons (REs) interact in several ways, making it important to self-consistently model these interactions for accurate predictions of RE generation and the design of mitigation strategies, such as massive gas injection (MGI). Using M3D-C1 – an extended MHD code with a RE fluid model – we investigate the effects of 3-D nonlinear MHD activity, material injection, and 2-D axisymmetric vertical displacement events (VDEs) on RE evolution during disruptions on SPARC – a high-field, high-current tokamak designed to achieve a fusion gain Q > 1. Several cases, comprising different combinations of neon (Ne) and deuterium (D 2 ) injection, are considered. Here, our results demonstrate key effects that arise from the self-consistent RE + MHD coupling, such as an initial increase in RE generation due to MHD instability growth, decreased saturation energies of the m/n = 1/1 mode driving sawteeth-like activity, RE losses in stochastic magnetic fields, and subsequent RE confinement and plateau formation due to re-healing of flux surfaces. Large RE plateaus (>5 MA) are obtained with Ne-only injection (2-5 × 10 21 atoms), while combined D 2 + Ne injection (2 × 10 21 Ne atoms; 1.8 × 10 22 D 2 molecules) produces a lower RE current (<2 MA). With D 2 + Ne injection, a post thermal quench "cold" VDE terminates the RE beam, preventing a steady plateau. These simulations couple REs, 3-D MHD instabilities, MGI, and axisymmetric VDEs for the first time in SPARC disruption simulations and represent a crucial step in understanding RE generation and mitigation in high-current devices like SPARC.

Datta, Rishabh [Massachusetts Inst. of Technology

Volumetric carrier injection in InGaN quantum well light emitting diodes

InGaN/GaN quantum well (QW) light emitting diodes (LEDs) are essential components of solid-state lighting and displays. However, the efficiency of long wavelength (green to red) devices is inferior to that of blue LEDs. To a large degree, this occurs because the equilibration of injected holes between multiple QWs of the active region is hindered by GaN quantum confinement and polarization barriers. This drawback could be overcome by volumetric hole injection into all QWs through semipolar QWs present on the facets of V-defects that form at threading dislocations in polar GaN-based structures. In this work, we have tested the viability of this injection mechanism and studied its properties by time-resolved and near-field spectroscopy techniques. Here, we have found that indeed the hole injection via the V-defects does take place, the mechanism is fast, and the hole spread from the V-defect is substantial, making this type of injection feasible for efficient long wavelength GaN LEDs.

InGaN/GaN quantum wells

Time-Lapse Electromagnetic Methods for Monitoring Plume Development in a Carbon Storage Reservoir

Conference presentation at International Meeting for Applied Geoscience & Energy (IMAGE), Houston, Texas, August 25–28, 2025. The Energy & Environmental Research Center (EERC) is leading applied research on electromagnetic (EM) monitoring methods at an active carbon storage site in North Dakota. Injection operations at the site began in February 2024, with a permitted injection rate of up to 2.7 million tonnes of CO 2 annually using six injection wells. CO 2 is captured on-site and injected into the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer located at a depth of approximately 1800 meters. The EERC led acquisition of multiple active- and passive-source EM techniques between August and October of 2024 to provide a thorough understanding of the resistivity profile at the site.

02 PETROLEUM

Dynamic modeling studies of basin-scale pressure interference and CO 2 plume evolution in multi-well geologic CO 2 storage

This research employs numerical modeling to analyze how CO 2 plumes and pressure fronts evolve when CO 2 is injected into a single storage formation from multiple projects located in proximity. Here, this analysis also evaluates the extent to which injection well spacing alleviates pressure buildup in the absence of active pressure management tactics. The simulation approach was based on a single, homogenous saline aquifer in which CO 2 injection occurs under a one-injector baseline case and several multi-well cases where well spacing varies. Analysis results show that the extent of pressure buildup is in the range of tens or a few hundreds of kilometers and contingent upon the defining pressure buildup demarcating the front edge. For the geological setting evaluated in this paper, our analysis suggests that without active basin pressure management strategies, commercial-scale projects would likely need to be sited far apart to avoid pressure interference from one another. Analysis results show the radius of CO 2 plume varies approximately from 2 to 3 km from injection wells (each injecting 1 Mt/year for 30 years) depending on cases and modeling parameters assumed. Given the pressure interference, this paper thus draws attention to the importance of greater coordination among storage operators and regulatory stakeholders. Because this analysis assumes a very specific geologic setting, this exploratory analysis bears further investigations across other geologic scenarios.

42 ENGINEERING

One Earth Energy FEED Process Design Basis

This report establishes the process design basis for the front-end engineering design (FEED) of a carbon capture and injection facility at One Earth Energy's (OEE) ethanol production plant in Gibson City, Illinois, developed as part of the Illinois Storage Corridor CarbonSAFE Phase III project. The facility is designed to compress and dehydrate up to approximately 458,000 metric tonnes of CO 2 per year, sourced directly from OEE's ethanol fermenters, for permanent injection into a saline aquifer approximately four miles from the plant. At normal operating conditions, the system will process 1,290 metric tonnes of CO 2 per day, assuming 355 operating days per year and an ethanol production rate of 160 million gallons per year. The proposed process trains a multistage centrifugal blower with a five-stage reciprocating compressor, delivering CO 2 to the injection wellhead at up to 1,500 psig. Triethylene glycol (TEG) dehydration, applied after the fourth compression stage, reduces water content to a target of 10 lb/MMscf, well within the 30 lb/MMscf injection limit. Beyond dehydration, no additional treatment is required; trace impurities including oxygen and nitrogen will remain in the injected stream. Key design considerations include the absence of spare cooling tower capacity at the site, necessitating new cooling infrastructure, and the need for a new electrical substation to support large motor loads. The facility is designed for continuous, largely unattended operation, monitored around the clock by existing OEE operations staff. This document serves as the foundational reference for all subsequent detailed engineering activities associated with the OEE CO 2 injection facility.

01 COAL, LIGNITE, AND PEAT