Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Industry Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An evaluation of selected NASA scientific and technical information products: Results of a pilot study

A pilot study was conducted to evaluate selected NASA scientific and technical information (STI) products. The study, which utilized survey research in the form of a self-administered mail questionnaire, had a two-fold purpose -- to gather baseline data regarding the use and perceived usefulness of selected NASA STI products and to develop/validate questions that could be used in a future study concerned with the role of the U.S. government technical report in aeronautics. The sample frame consisted of 25,000 members of the American Institute of Aeronautics and Astronautics in the U.S. with academic, government or industrial affiliation. Simple random sampling was used to select 2000 individuals to participate in the study. Three hundred fifty-three usable questionnaires (17 percent response rate) were received by the established cutoff date. The findings indicate that: (1) NASA STI is used and is generally perceived as being important; (2) the use rate for NASA-authored conference/meeting papers, journal articles, and technical reports is fairly uniform; (3) a considerable number of respondents are unfamiliar with STAR (Scientific and Technical Aerospace Reports), IAA (International Aerospace Abstracts), SCAN (Selected Current Aerospace Notices), and the RECON on-line retrieval system; (4) a considerable number of respondents who are familiar with these media do not use them; and (5) the perceived quality of NASA-authored journal articles and technical reports is very good.

Pinelli, Thomas E.↗

Review of industry interest in space processing

The interest on the part of selected U.S. corporation in using the research facilities and capabilities for materials processing in space utilizing the Space Shuttle was assessed. The effectiveness of the interview techniques as a method for gaining insight into the complex array of issues related to materials processing in space was evaluated. The survey, conducted was intended as a random sample of individuals, representing industry, who were currently involved in materials processing in space.

Mcdowell, J. R.↗

Development of chemometric models to classify solid-state U materials by micro-Raman spectroscopy

Discerning uranium (U) particles found in environmental sampling is of interest for monitoring the peaceful use of nuclear material. In this study, a soft independent modeling of class analogy (SIMCA) library was successfully developed for the classification of a four-class system consisting of α-U 3 O 8 , UO 2 , UO 2 (NO 3 ) 2 ·6H 2 O (UNH), and UO 2 O 2 ·4H 2 O (studtite) by Raman spectroscopy in the presence of matrix particulates and additional outliers. Spectral variability between numerous particles of each type revealed appreciable differences as a function of particle size with respect to hydration state and potential oxide phase within each class. Interclass variability was accounted for using both unsupervised and supervised chemometric models. The supervised SIMCA model displayed reasonable sensitivity for each U class and a high degree of specificity by returning whether a spectrum belonged to one class or not. This work demonstrates how Raman spectral features and chemometrics can be used to distinguish U materials from one another and from matrix materials such as flint clay. Combining the outlined chemometric approach with Raman mapping sequences could provide a rapid, nondestructive technique to characterize the chemical composition of a diverse collection of U compounds amid background samples for environmental sampling, nuclear forensics, and industrial applications.

Actinide↗

Sampling the ENSO response to tropical volcanic eruptions in the GISS-E2-1 model: physical & biogeochemical ocean effects

Despite observational evidence that an El-Niño is likely to follow tropical volcanic eruptions (Predybaylo et al, 2017), modelling studies have so far reached no consensus on either the sign or physical mechanism of El Niño response to volcanism (Khodri et al, 2017) . A previous modelling study found that following the Pinatubo eruption, the tropical Pacific developed El Niño-like conditions that triggered a decrease in the upwelling of DIC and increased carbon uptake (Eddebbar et al., 2019). However, the carbon cycle response to volcanisms as it depends on ENSO phase remains unclear. Here we perform thirty ensemble control simulations using the GISS-E2-1-G model to sample the pre-industrial control ENSO cycle and thirty more to superimpose a Pinatubo-like volcanic eruption. We find that the model tends to favor the development of a weak El-Niño following the volcanic eruption only in the case of a volcano that erupts at the start of a neutral ENSO phase. In response to the weak El-Niño, some anomalies have the same sign as those that develop from a strong El-Niño, such as weaker winds, shallower mixed layer depths, less direct but more diffuse radiation at the surface of the ocean, less nitrate, and lower primary productivity. However, other anomalies show the opposite sign as those from a strong El-Niño, such as more precipitation, less surface DIC, and less surface ocean pCO 2 . In contrast to the neutral phase, the volcanic response during positive ENSO and negative ENSO phases are swamped by the model’s internal variability.

ENSO↗

Compact X-band split electron linac for cabinet-size small-sample irradiators

Many small-scale industrial radiation facilities rely on hazardous radioisotope-based gamma ray irradiators, which are being gradually replaced by alternative technologies, such as particle accelerators. RadiaBeam has developed a compact, cabinet-size, 3 MeV electron-linac-based irradiator to match the penetration of Co-60 and provide high irradiation throughput. Here the linac utilizes X-band RF power to reduce size, employs an innovative split-linac approach to lower costs, and features a novel X-ray conversion target geometry that spreads the beam out across the target, providing a low dose uniformity ratio. In this paper, we discuss the accelerator design, fabrication, and test results.

43 PARTICLE ACCELERATORS↗

Long-Term Groundwater Monitoring Report Industrial Area Kennedy Space Center, Florida

This report presents the 2023 groundwater sampling results from the National Aeronautics and Space Administration (NASA) Industrial Area (IA) Long-Term Monitoring (LTM) activities. Due to the project contract ending in 2023, this report presents one year of LTM activities instead of the two-year timeframe presented in previous reports. The NASA IA LTM Program includes the following 12 sites: - Ransom Road Landfill (RRLF) – Solid Waste Management Unit (SWMU) 003 - Building M7-0505 Treatment Tank Area (M505) – SWMU 039 - Operations and Checkout Building (O&C) – SWMU 076 - Vertical Processing Facility (VPF) – SWMU 077 - Environmental Health Facility (EHF) – SWMU 079 - Kennedy Athletic, Recreation, and Social Park 1 (KARS Park 1) – SWMU 084 - Engineering Development Laboratory (EDL) – SWMU 085 - Launch Equipment Test Facility (LETF) – SWMU 091 - Mobil Service Station (MOBIL) – SWMU 093 - General Services Administration Seized Property (GSSP) – SWMU 095 - Space Station Processing Facility (SSPF) – SWMU 098 - Fuel Storage Area #1 Underground Storage Tank [Building 1044] (FSA1) – Potential Release Location (PRL) 157 Sampling events for the IA LTM Program are conducted seasonally during the dry and wet seasons, which occur in May and November, respectively. The sites in the NASA IA LTM Program are sampled on annual, biennial, or 5-year sampling frequencies based on historical trends. The current sampling frequencies for the NASA IA LTM sites are as follows: - FSA1 is sampled annually, alternating between wet and dry seasons. - GSSP is sampled annually during the wet season. - Seven sites are sampled biennially, alternating between the wet and dry seasons (RRLF, M505, O&C, VPF, LETF, MOBIL, and SSPF). - EHF and EDL are sampled biennially during the wet season. - KARS Park 1 is sampled once every 5 years.

remediation↗

Portable Device Analyzes Rocks and Minerals

inXitu Inc., of Mountain View, California, entered into a Phase II SBIR contract with Ames Research Center to develop technologies for the next generation of scientific instruments for materials analysis. The work resulted in a sample handling system that could find a wide range of applications in research and industrial laboratories as a means to load powdered samples for analysis or process control. Potential industries include chemical, cement, inks, pharmaceutical, ceramics, and forensics. Additional applications include characterizing materials that cannot be ground to a fine size, such as explosives and research pharmaceuticals.

Source record↗

2021-2022 Long-Term Groundwater Monitoring Report Industrial Area Kennedy Space Center, Florida

This report presents the groundwater sampling results from the National Aeronautics and Space Administration (NASA) Industrial Area (IA) 2021-2022 Long-Term Monitoring (LTM) activities and results of the 2023 DPT activities at three of the sites. The NASA IA LTM Program includes the following 14 sites: - Ransom Road Landfill (RRLF) – Solid Waste Management Unit (SWMU) 003 - Orsino Storage Yard (ORSY) – SWMU 004 - Building M7-0505 Treatment Tank Area (M505) – SWMU 039 - Hypergol Maintenance Facility Hazardous Waste South Staging Area (HMF South) – SWMU 070 - Operations and Checkout Building (O&C) – SWMU 076 - Vertical Processing Facility (VPF) – SWMU 077 - Environmental Health Facility (EHF) – SWMU 079 - Kennedy Athletic, Recreation, and Social Park 1 (KARS Park 1) – SWMU 084 - Engineering Development Laboratory (EDL) – SWMU 085 - Launch Equipment Test Facility (LETF) – SWMU 091 - Mobil Service Station (MOBIL) – SWMU 093 - General Services Administration Seized Property (GSSP) – SWMU 095 - Space Station Processing Facility (SSPF) – SWMU 098 - Fuel Storage Area #1 Underground Storage Tank (UST) [Building 1044] (FSA1) – Potential Release Location (PRL) 157 Groundwater levels were gauged at each site during the 2021 and 2022 LTM field activities. Sampling events for the IA LTM Program are conducted seasonally during the dry and wet seasons, which occur in May and November, respectively. The sites in the NASA IA LTM Program are sampled on annual, biennial, or 5-year sampling frequencies based on historical trends. Due to contract transitions and monitoring well installations, 2021 dry season activities were conducted during September 2021, while dry season activities for 2022 resumed in May 2022.

groundwater↗

Reducing the cost of home energy upgrades in the US: An industry survey

Decarbonizing the US residential building stock requires a substantial acceleration in home energy upgrades. Numerous barriers exist to accelerating adoption of efficient and electric building technologies, but foremost among these is high upfront costs. This study uses an industry survey delivered to a sample of home energy professionals to examine promising cost reduction strategies across a range of project types, including HVAC, water heating, and envelope/insulation projects. The survey included quantitative and qualitative questions to collect evidence on the estimated cost reduction potential of these strategies and their likelihood of use in the construction industry. The 167 survey respondents included contractors, energy consultants, architects, manufacturers, and others with experience in delivering energy upgrades in single-family and multifamily buildings in the US. Results show that significant cost reductions are achievable by minimizing additional infrastructure costs (such as replacing electric panels), streamlining project planning/management, and deploying innovations that simplify installation. We find that for a typical deep retrofit project, including heat pumps for space and water heating in addition to envelope upgrades, the strategies could result in a total installed cost reduction of nearly 50%, dramatically improving the customer economics of such a project. This research makes a novel contribution to the literature on strategies to reduce the costs of residential retrofits. We discuss how our study's insights on the highest-value cost reduction strategies for home energy upgrades can further accelerate their uptake in the US housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

Caution on Using Tetrahydrofuran for Processing Crystalline Silica Samples From Engineered Stone for XRD Analysis

Abstract We conducted laboratory experiments to investigate a suspected effect of tetrahydrofuran (THF) on quantifying crystalline silica in samples collected from working with engineered stone when THF is used to process samples prior to the X-ray diffraction (XRD) analysis. Two groups of samples from grinding either engineered stone or granite were simultaneously taken from a laboratory testing system, with one group of samples using THF for processing and another group using muffle furnace for ashing. For each stone type, we also tested four levels of respirable dust loading on the samples by varying the grinding time from 1 to 8 min. Statistical analysis of the experimental results on crystalline silica contents of the two groups of samples showed that the difference between the two methods was not significant (P ≥ 0.05) for the granite at all four levels of respirable dust loading and for the engineered stone at the two levels of respirable dust loading greater than 0.5 mg. However, the crystalline silica content from using THF processing was significantly lower (P = 0.001) than that from using muffle furnace ashing for engineered stone when the respirable dust loading levels were less than 0.5 mg. For the engineered stone dust samples with grinding times of 1 and 2 min, the average respirable dust loading was about 0.19 and 0.34 mg, respectively; while the crystalline silica content from using THF processing was 30.9 and 21.5% lower than that from using muffle furnace ashing, respectively. Since most full-shift samples from field assessments in this industry are expected to have respirable dust loading less than 0.5 mg, muffle furnace or radio frequency plasma ashing should be specified as the preferred sample processing method instead of the THF processing method for quantification of crystalline silica when engineered stone is expected to present to avoid artificially reduced silica content values, which are likely caused by the reactions between THF and the resins in engineered stone.

Public, Environmental & Occupational Health↗

Microbial Diffraction Gratings as Optical Detectors for Heavy Metal Pollutants

As a significant industrial pollutant, cadmium is implicated as the cause of itai-itai disease. For biological detection of cadmium toxicity, an assay device has been developed using the motile response of the protozoa species, Tetrahymena pyriformis. This mobile protozoa measures 50 microns in diameter, swims at 10 body lengths per second, and aggregates into macroscopically visible patterns at high organism concentrations. The assay demonstrates a Cd(+2) sensitivity better than 1 micro-M and a toxicity threshold to 5 micro-M, thus encouraging the study of these microbial cultures as viable pollution detectors. Using two-dimensional diffraction patterns within a Tetrahymena culture, the scattered light intensity varies with different organism densities (population counts). The resulting density profile correlates strongly with the toxic effects at very low dosages for cadmium (less than 5 ppm) and then for poison protection directly (with nickel and copper antagonists competing with cadmium absorption). In particular, copper dosages as low as 0.1-0.5 mM Cu have shown protective antagonism against cadmium, have enhanced density variability for cultures containing 1 mM Cd(+2) and therefore have demonstrated the sensitivity of the optical detection system. In this way, such microbial diffraction patterns give a responsive optical measure of biological culture changes and toxicity determination in aqueous samples of heavy metals and industrial pollutants.

Noever, David↗

Degree of interdependence among atmospheric optical thicknesses in spectral bands between 0.36-2.4 micron

The degree of dependence among the atmospheric optical thicknesses that are measured in nonselective absorption bands is studied. The observations were made previously in many spectral bands within the range 0.36-2.4 micron from near sea level in two continents where urban and industrial pollutions were weak. The sample covariance matrices and corresponding eigenvalues and eigenvectors are computed. The two highest eigenvalues account for 90% of the total variance in 10 spectral bands within the range 0.4-1.6 micron. The linear regression of the optical thickness on the total precipitable water vapor is computed to determine the attenuation coefficient that is associated with water vapor. This coefficient shows a rapid power-law decrease with wavelength in the visible spectrum and indicates that numerous water particles of radius 0.03-0.06 micron cause the attenuation.

Fraser, R. S.↗

Fuzzy Logic Approaches to Multi-Objective Decision-Making in Aerospace Applications

Fuzzy logic allows for the quantitative representation of multi-objective decision-making problems which have vague or fuzzy objectives and parameters. As such, fuzzy logic approaches are well-suited to situations where alternatives must be assessed by using criteria that are subjective and of unequal importance. This paper presents an overview of fuzzy logic and provides sample applications from the aerospace industry. Applications include an evaluation of vendor proposals, an analysis of future space vehicle options, and the selection of a future space propulsion system. On the basis of the results provided in this study, fuzzy logic provides a unique perspective on the decision-making process, allowing the evaluator to assess the degree to which each option meets the evaluation criteria. Future decision-making should take full advantage of fuzzy logic methods to complement existing approaches in the selection of alternatives.

Hardy, Terry L.↗

PCR Based Microbial Monitor for Analysis of Recycled Water Aboard the ISSA: Issues and Prospects

The monitoring of spacecraft life support systems for the presence of health threatening microorganisms is paramount for crew well being and successful completion of missions. Development of technology to monitor spacecraft recycled water based on detection and identification of the genetic material of contaminating microorganisms and viruses would be a substantial improvement over current NASA plans to monitor recycled water samples that call for the use of conventional microbiology techniques which are slow, insensitive, and labor intensive. The union of the molecular biology techniques of DNA probe hybridization and polymerase chain reaction (PCR) offers a powerful method for the detection, identification, and quantification of microorganisms and viruses. This technology is theoretically capable of assaying samples in as little as two hours with specificity and sensitivity unmatched by any other method. A major advance in probe-hybridization/PCR has come about in a technology called TaqMan(TM), which was invented by Perkin Elmer. Instrumentation using TaqMan concepts is evolving towards devices that could meet NASA's needs of size, low power use, and simplicity of operation. The chemistry and molecular biology needed to utilize these probe-hybridization/PCR instruments must evolve in parallel with the hardware. The following issues of chemistry and biology must be addressed in developing a monitor: Early in the development of a PCR-based microbial monitor it will be necessary to decide how many and which organisms does the system need the capacity to detect. We propose a set of 17 different tests that would detect groups of bacteria and fungus, as well as specific eukaryotic parasites and viruses; In order to use the great sensitivity of PCR it will be necessary to concentrate water samples using filtration. If a lower limit of detection of 1 microorganism per 100 ml is required then the microbes in a 100 ml sample must be concentrated into a volume that can be added to a PCR assay; There are not likely to be contaminants in ISSA recycled water that would inhibit PCR resulting in false-negative results; The TaqMan PCR product detection system is the most promising method for developing a rapid, highly automated gene-based microbial monitoring system. The method is inherently quantitative. NASA and other government agencies have invested in other technologies that, although potentially could lead to revolutionary advances, are not likely to mature in the next 5 years into working systems; PCR-based methods cannot distinguish between DNA or RNA of a viable microorganism and that of a non-viable organism. This may or may not be an important issue with reclaimed water on the ISSA. The recycling system probably damages the capacity of the genetic material of any bacteria or viruses killed during processing to serve as a template in a PCR desinged to amplify a large segment of DNA (less than 650 base pairs). If necessary, vital dye staining could be used in addition to PCR, to enumerate the viable cells in a water sample; The quality control methods have been developed to insure that PCR's are working properly, and that reactions are not contaminated with PCR carryover products which could lead to the generation of false-positive results; and The sequences of the small rRNA subunit gene for a large number of microorganisms are known, and they consititue the best database for rational development of the oligonucleotide reagents that give PCR its great specificity. From those gene sequences, sets of oligonucleotide primers for PCR and Taqman detection that could be used in a NASA microbial monitor were constructed using computer based methods. In addition to space utilization, a microbial monitior will have tremendous terrestrial applications. Analysis of patient samples for microbial pathogens, testing industrial effluent for biofouling bacteria, and detection biological warfare agents on the battlefield are but a few of the diverse potential uses for this technology. Once fully developed, gene-based microbial monitors will become the fundamental tool in every lab that tests for microbial contaminants, and serve as a powerful weapon in mankind's war with the germ world.

Cassell, Gail H.↗

Compact Microscope Imaging System Developed

The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. The CMIS can be used in situ with a minimum amount of user intervention. This system, which was developed at the NASA Glenn Research Center, can scan, find areas of interest, focus, and acquire images automatically. Large numbers of multiple cell experiments require microscopy for in situ observations; this is only feasible with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control capabilities. The software also has a user-friendly interface that can be used independently of the hardware for post-experiment analysis. CMIS has potential commercial uses in the automated online inspection of precision parts, medical imaging, security industry (examination of currency in automated teller machines and fingerprint identification in secure entry locks), environmental industry (automated examination of soil/water samples), biomedical field (automated blood/cell analysis), and microscopy community. CMIS will improve research in several ways: It will expand the capabilities of MSD experiments utilizing microscope technology. It may be used in lunar and Martian experiments (Rover Robot). Because of its reduced size, it will enable experiments that were not feasible previously. It may be incorporated into existing shuttle orbiter and space station experiments, including glove-box-sized experiments as well as ground-based experiments.

McDowell, Mark↗

Three-Body Abrasion Testing Using Lunar Dust Simulants to Evaluate Surface System Materials

Numerous unexpected operational issues relating to the abrasive nature of lunar dust, such as scratched visors and spacesuit pressure seal leaks, were encountered during the Apollo missions. To avoid reoccurrence of these unexpected detrimental equipment problems on future missions to the Moon, a series of two- and three-body abrasion tests were developed and conducted in order to begin rigorously characterizing the effect of lunar dust abrasiveness on candidate surface system materials. Two-body scratch tests were initially performed to examine fundamental interactions of a single particle on a flat surface. These simple and robust tests were used to establish standardized measurement techniques for quantifying controlled volumetric wear. Subsequent efforts described in the paper involved three-body abrasion testing designed to be more representative of actual lunar interactions. For these tests, a new tribotester was developed to expose samples to a variety of industrial abrasives and lunar simulants. The work discussed in this paper describes the three-body hardware setup consisting of a rotating rubber wheel that applies a load on a specimen as a loose abrasive is fed into the system. The test methodology is based on ASTM International (ASTM) B611, except it does not mix water with the abrasive. All tests were run under identical conditions. Abraded material specimens included poly(methyl methacrylate) (PMMA), hardened 1045 steel, 6061-T6 aluminum (Al) and 1018 steel. Abrasives included lunar mare simulant JSC- 1A-F (nominal size distribution), sieved JSC-1A-F (<25 m particle diameter), lunar highland simulant NU-LHT-2M, alumina (average diameter of 50 m used per ASTM G76), and silica (50/70 mesh used per ASTM G65). The measured mass loss from each specimen was converted using standard densities to determine total wear volume in cm3. Abrasion was dominated by the alumina and the simulants were only similar to the silica (i.e., sand) on the softer materials of aluminum and PMMA. The nominal JSC- 1A-F consistently showed more abrasion wear than the sieved version of the simulant. The lunar dust displayed abrasivity to all of the test materials, which are likely to be used in lunar landing equipment. Based on this test experience and pilot results obtained, recommendations are made for systematic abrasion testing of candidate materials intended for use in lunar exploration systems and in other environments with similar dust challenges.

Kobrick, Ryan L.↗

International Space Station (ISS) 3D Printer Performance and Material Characterization Methodology

In order for human exploration of the Solar System to be sustainable, manufacturing of necessary items on-demand in space or on planetary surfaces will be a requirement. As a first step towards this goal, the 3D Printing In Zero-G (3D Print) technology demonstration made the first items fabricated in space on the International Space Station. From those items, and comparable prints made on the ground, information about the microgravity effects on the printing process can be determined. Lessons learned from this technology demonstration will be applicable to other in-space manufacturing technologies, and may affect the terrestrial manufacturing industry as well. The flight samples were received at the George C. Marshall Space Flight Center on 6 April 2015. These samples will undergo a series of tests designed to not only thoroughly characterize the samples, but to identify microgravity effects manifested during printing by comparing their results to those of samples printed on the ground. Samples will be visually inspected, photographed, scanned with structured light, and analyzed with scanning electron microscopy. Selected samples will be analyzed with computed tomography; some will be assessed using ASTM standard tests. These tests will provide the information required to determine the effects of microgravity on 3D printing in microgravity.

Bean, Q. A.↗