Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evidence for a Solid-Electrolyte Inductive Effect in the Superionic Conductor Li 10 Ge 1– x Sn x P 2 S 12

Strategies to enhance ionic conductivities in solid electrolytes typically focus on the effects of modifying their crystal structures or of tuning mobile-ion stoichiometries. A less-explored approach is to modulate the chemical bonding interactions within a material to promote fast lithium-ion diffusion. Recently, the idea of a solid-electrolyte inductive effect has been proposed, whereby changes in bonding within the solid-electrolyte host framework modify the potential energy landscape for the mobile ions, resulting in an enhanced ionic conductivity. Direct evidence for a solid-electrolyte inductive effect, however, is lacking—in part because of the challenge of quantifying changes in local bonding interactions within a solid-electrolyte host framework. Here, we consider the evidence for a solid-electrolyte inductive effect in the archetypal superionic lithium-ion conductor Li 10 Ge 1–x Sn x P 2 S 12 . Substituting Ge for Sn weakens the {Ge,Sn}–S bonding interactions and increases the charge density associated with the S 2– ions. This charge redistribution modifies the Li + substructure causing Li + ions to bind more strongly to the host framework S 2– anions, which in turn modulates the Li + ion potential energy surface, increasing local barriers for Li + ion diffusion. Each of these effects is consistent with the predictions of the solid-electrolyte inductive effect model. Density functional theory calculations predict that this inductive effect occurs even in the absence of changes to the host framework geometry due to Ge → Sn substitution. These results provide direct evidence in support of a measurable solid–electrolyte inductive effect and demonstrate its application as a practical strategy for tuning ionic conductivities in superionic lithium-ion conductors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Current ramp-up studies for NSTX-U in support of the development of non-inductive current ramp-up scenarios in STs

The Spherical Tokamak (ST) is a low-aspect-ratio tokamak projected to enable simultaneous operation at high normalized toroidal beta and high bootstrap current fraction. However, a compact ST reactor cannot be built with a full-sized solenoid. The remaining current required for sustained operation must be ramped up non-inductively. Sustained 100% non-inductive current drive at the MA level has not yet been demonstrated on an ST. Non-inductive current ramp-up is therefore a more challenging objective that the NSTX-U research program aims to address. In support of this development, free-boundary TRANSP simulations have been used to develop a current ramp-up scenario in which a significant fraction of the current is driven non-inductively by a combination of neutral-beam and bootstrap current drive. The resulting discharge has properties favorable for non-inductive current drive, such as a low normalized internal plasma inductance of approximately 0.45, a minimum safety factor exceeding 2, and a slightly reversed-shear q-profile. In these discharges, the plasma current ramps to 900 kA within 250 ms in an L-mode configuration, with varying electron density and density profiles. These discharges should be suitable for next-step NSTX-U experiments aimed at generating a robust L-mode fiducial scenario with low central solenoid flux consumption, which could be progressively improved as new NSTX-U experimental discharges are developed.

Raman, Roger [Univ. of Washington, Seattle, WA (Un↗

Parasitic Effects in Impedance Spectrum of PEM Water Electrolysis Cells: Case Study of High-Frequency Inductive Effects

Electrochemical impedance spectroscopy (EIS) is a powerful tool to characterize and distinguish electrochemical, electrical, and diffusive processes in an electrolysis cell. The EIS response with small impedance (mΩ) depends on components and materials of the cell, but often also on the electrical setup, cables, and connectors, leading to incorrect conclusions about the performance of the electrolysis cells. These parasitic effects are assessed via a short-circuit measurement and confirmed to be external from the membrane electrode assembly (MEA). In the setup, the inductive characteristic is described by a modified inductive reactance and must be included in the equivalent circuit model (ECM) which is fitting the cell EIS spectra in operation (in situ). If points of the spectra showing inductive characteristic (below x-axis in Nyquist plot) are excluded from the ECM evaluation, an artificially increased ohmic resistance at high frequencies is obtained. In addition, considerations on other components of the ECM can be misleading and significantly incorrect. The only way to avoid that inductive behavior caused by the external setup is incorrectly assigned to the ECM describing properties of the MEA is to include the inductive effects in the ECM analysis of in situ EIS measurements.

30 DIRECT ENERGY CONVERSION↗

A new tubular ironless linear induction motor using non-interrupted winding method

The ironless linear induction motor device can be used for any application which requires a large motion span or rotation restrictedly by the ironless feature due to the strong magnetic field environment. One of the possible applications is ITER diagnostics shutters. The tokamak reactor systems have a severe radiation issue during the operation. The traditional Kapton-insulated wires have significantly lower radiation resistance than an expected large radiation dose at ITER Motion Stark Effect (MSE) shutter location. Furthermore, the traditional single-sided linear induction motor winds the wire to make the N-turn pitch coils independently and then connect them in series to make a one-phase winding. Therefore, it is a big challenge to make so many radiation-protection connectors in such a limited space as inside the vacuum vessel of fusion reactors. The approved mineral-insulated kinds of cables need a large bend radius for the end turns, so the traditional single-sided linear motor with two-layer three-phase windings need to be upgraded to the tubular linear motors. The new proposed tubular ironless linear induction motor can not only overcome the large bend radius issue with the mineral-insulated cables but also allow the motor coils wound continuously around the tubular-shaped stator, forward and backward N times to make a N-turn winding for each phase, in order to resolve the radiation protection issue with the winding connection. The 3D transient Maxwell electromagnetic model with a tubular three-phase linear induction motor has been analyzed. Furthermore, this paper will present the detailed design and winding method of ironless linear induction motor actuators, and results of the 3D transient numerical simulation of the actuator performance.

Ironless↗

Soil aminopeptidase induction is unaffected by inorganic nitrogen availability

Soil microbes release a variety of aminopeptidase enzymes to degrade proteins into their constituent amino acid monomers, thereby increasing amino acid availability in the near-cell environment. In this work we investigated how inorganic N availability controls the substrate induction response of aminopeptidase enzymes by conducting protein amendment experiments via gelatin addition to fertilized and unfertilized soil from a long-term N addition study. Protein addition triggered a measurable increase in enzyme activity, which we interpreted as an induction response, in all five of the aminopeptidase enzymes we investigated. The magnitude of these induction responses did not differ by fertilization regime even when unamended aminopeptidase activity differed between long-term fertilization treatments. Though soil microbes are thought to release aminopeptidase enzymes as a means of cellular N acquisition at steady-state concentrations, our results suggest that they use the same enzymes to access protein-derived C as an energetic resource at non-steady-state conditions, such as those triggered by the substrate induction response. The substrate induction response of aminopeptidase enzymes is therefore best viewed as a means of microbial competition for the substantial energetic resources available in protein subsidies.

60 APPLIED LIFE SCIENCES↗

Non-inductive plasma vertical position measurement for the 1056 s discharge on EAST

Vertical position stability plays a crucial role in maintaining safe and reliable plasma operation for long-pulse fusion devices. In general, the vertical position is measured by using inductive magnetic coils installed inside the vacuum vessel; however, the integration drift effects are inherent for steady-state or long-pulse plasma operation. Further, developing a non-magnetic approach provides a fusion reactor-relevant steady-state solution that avoids the negative impact of integration drift. In this paper, we compare the non-inductively determined vertical position achieved by line-integrated interferometer and polarimeter measurements to that employing an inductive flux loop for a 1056 s discharge recently achieved on EAST (Experimental Advanced Superconducting Tokamak). Experimental results show that the non-inductive measurement is more robust than flux loops after 300 s if the integrator is not reset to suppress integrator drift. Real-time vertical position control using the non-inductive system is proposed for the next EAST experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical and Analytical Modeling of the Effect of Cracks on the Self-Inductance of a COTS YJ-41003-TC Toroid

COTS inductors and transformers often contain partial cracks whose effect on inductance, a key performance parameter, have not been carefully studied. In this report, the effects of both partial and complete cracks on the self-inductance of a 100 turn square cross section COTS YJ-41003-TC toroid comprised of J Material was comprehensively investigated using both analytically derived closed form expressions and 3D computational techniques employing commercial codes. Both partial (half-penny) and complete (air gap) cracks of 10 and 25 μm were investigated. The crack is defined as the physical distance between two faces of the toroid's magnetic core, such that the surface normal of either face is along the Φ-direction, in alignment with the B-field. For the purposes of validation, two different approaches were incorporated for both the analytical and numerical models. The two analytical methods are comprised of a first principles approach based on the physics of electromagnetics, as well as linear circuit theory. The former directly utilizes the integral form of Maxwell's equations while the latter exploits the interchangeable relationship between electric and magnetic circuits. Validation within the computational scheme is realized through a code-to-code comparison between commercial solvers, COMSOL Multiphysics and CST, with the former employing the Finite Element Method (FEM) and the latter the Finite Difference Time Domain (FDTD) technique. Sound agreement between all four methods (ie., two analytical and two numerical) is observed, with results indicating that only a perturbation in self-inductance occurs for the half-penny cracks, while a substantial reduction takes place for the case of complete cracks. It is important to note that even though a static μ r is applied, representing the linear region of the BH curve (based on manufacturer specifications), the complete crack results still place a lower conservative bound on the inductance. This follows from the fact that even in the case of a half-penny crack, if the magnetic core portion of the crack approaches saturation, the crack begins to behave like an air gap, or complete crack. When an air gap is introduced into a magnetic core, a substantial reduction in inductance can occur due to the significant difference in permeabilities between the two mediums (ie., μ core >> μ air ). The once intact bulk magnetic core of the toroid essentially begins to behave like an air core.

36 MATERIALS SCIENCE↗

High-Bandwidth Low-Inductance Current Shunt for Wide-Bandgap Devices Dynamic Characterization

High bandwidth sensors are required to measure the wide-bandgap devices' transient behavior because of their fast switching speed. In addition to high bandwidth, the current sensor must introduce little extra parasitic inductance to the switching power loop. The analysis of conventional shunt resistors shows the key to high bandwidth is the coaxial structure and its parasitic inductance is proportional to its transient heat energy rating. Additionally, by combining the structure of coaxial shunt resistor and alumina substrate surface mount thin film resistors, a novel surface mount coaxial shunt resistor is introduced. Experimental measurement verifies its capability of achieving very high bandwidth while introducing very low parasitic inductance. The design can achieve up to 2.23-GHz measurement bandwidth while keeping its parasitic inductance as low as 0.12 nH. Application in gallium nitride heterojunction-field-effect-transistors double pulse test shows it can faithfully capture the transient current waveform while introducing little interference to the switching behavior.

42 ENGINEERING↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Inductance of a Single-Channel Spark-Gap Switch for Pulsed Power Applications

In this paper, we derive an alternative expression for calculating the inductance of a single-channel spark-gap switch. We believe this new inductance expression provides greater clarity compared to other approaches. Interestingly, both the Rosa formula and the coaxial inductance formula, which are commonly used in such calculations, emerge as special cases of our new expression. To validate the proposed formula, we conducted COMSOL simulations that show excellent agreement with our theoretical predictions.

COMSOL↗

Measured Indoor Nitrogen Oxides in Homes with a Child with Asthma and Gas or Induction Electric Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study is a randomized control trial investigating the effects of replacing gas with induction electric ranges in the homes of children with asthma in California's San Joaquin Valley. Indoor air quality parameters and respiratory health indicators were measured over 2-week intensive at Baseline and after consecutive 3-month study phases, with half getting electric cooking at the start of Phase 1 and others in Phase 2. Indoor air measurements included time-integrated NO 2 and NO X by passive sampler and time-resolved NO 2 by electrochemical sensors. In the first 40 homes, data were collected during 61 intensives for gas cooking and 55 for induction. Cooking was identified using temperature sensors above the cooktop. Pollutant events were identified from sharp rises in concentrations Time integrated NOX species were lower with electric cooking, with mean differences of 14.2 ppb for NO 2 (95% CI: 9.6, 18.7; p < 0.001), 55.6 ppb for NO X (95% CI: 30.4, 80.9; p < 0.001), and 41.5 ppb for derived NO (95% CI: 19.7, 63.2; p < 0.001). A paired, within home analysis showed larger reductions in Group 2 (gas to induction) than Group 1 that remained electric across Phase 1 and Phase 2 for NO 2 (mean difference in As of 10.5 ppb; 95% CI: 5.6, 15.4; p < 0.001), NO X (32.3 ppb; 95% CI: 10.0, 54.5; p=0.007), and derived NO (21.8 ppb; 95% CI: 3.6, 40.0; p=0.022). Compared to electric cooking, gas had much higher rates of associated NO 2 events, and larger above-baseline NO 2 peaks. These preliminary results are consistent with prior findings that shifting to induction cooking can substantially lower indoor NO 2 compared with gas cooking.

Fang, Yi↗

Emergent Inductance from Chiral Orbital Currents in a Bulk Ferrimagnet

Here, we report the discovery of a new form of inductance in the bulk ferrimagnet Mn 3 ⁢Si 2 ⁢Te 6 , which features strong spin-orbit coupling, large magnetic anisotropy, and pronounced magnetoelastic interactions. Below its Curie temperature (𝑇 𝐶 ≈ 78 K), Mn 3 ⁢Si 2 ⁢Te 6 hosts chiral orbital currents (COC) that circulate within the crystal lattice and give rise to collective electronic behavior [Control of chiral orbital currents in a colossal magnetoresistance material, Nature (London) 611, 467 (2022).]. By applying a magnetic field along the hard 𝑐 axis and driving the system with low-frequency currents, we uncover a giant inductive response up to millhenry scale, originating from first-order reconfigurations of COC domains. These domains act as coherent mesoscopic inductive elements that resist reversal upon current reduction, producing a large electromotive force and sharply increasing voltage. This emergent inductance defies classical models, occurs without superconductivity or engineered nanostructures, and opens a new frontier in orbital-based quantum functionality and device concepts.

complex materials↗

Impact of the Transformer Magnetizing Inductance on the Performance of the Dual-Active Bridge Converter

The magnetizing inductance of the high-frequency transformer in the dual-active bridge (DAB) converter is usually assumed to be much larger than its leakage inductance, thereby the magnetizing current can be negligible. However, ignoring the magnetizing current will lead to an error in the DAB converter design process. This paper analyzes the operation and performance of the DAB converter for a general case in which the transformer magnetizing inductance is taken into consideration. The analysis shows that the magnetizing inductance impacts the soft-switching region, the power transfer capability, and the leakage inductor current. A simulation case study is provided to verify the analysis. A DAB converter prototype is built to experimentally validate the analysis as well.

Yin, Shiyuan↗

Stacked-Die SiC Half-Bridge Module with Minimum Loop Inductance

Minimizing parasitic inductance of power modules is needed to advance their electrical performance. Innovation in the past decade has driven down the inductance of SiC half-bridge power modules to around 1–2 nH by using multilayer, embedded, and hybrid structures. Further reduction becomes difficult, mainly limited by the excessive interconnects required for the planar placement of vertical conducting chips. To address this, a vertically stacked-die approach is proposed in this paper, taking advantage of the vertical conducting nature of the SiC chips. With ceramic decoupling capacitors integrated, 0.48 nH overall loop inductance is achieved and validated by experimental measurement. This paper also discusses potential approaches to further reduce the inductance.

Ribeiro, Pedro↗

Developing inductively driven diagnostic X-ray sources to enable transformative radiography and diffraction capabilities on Z

Penetrating X-rays are one of the most effective tools for diagnosing high energy density experiments, whether through radiographic imaging or X-ray diffraction. To expand the X-ray diagnostic capabilities at the 26-MA Z Pulsed Power Facility, we have developed a new diagnostic X-ray source called the inductively driven X-pinch (IDXP). This X-ray source is powered by a miniature transmission line that is inductively coupled to fringe magnetic fields in the final power feed. The transmission line redirects a small amount of Zs magnetic energy into a secondary cavity where 150+ kA of current is delivered to a hybrid X-pinch. In this report, we describe the multi-stage development of the IDXP concept through experiments both on Z and in a surrogate setup on the 1 MA Mykonos facility. Initial short-circuit experiments to verify power ow on Z are followed by short-circuit and X-ray source development experiments on Mykonos. The creation of a radiography-quality X-pinch hot spot is verified through a combination of X-ray diode traces, laser shadowgraphy, and source radiography. The success of the IDXP experiments on Mykonos has resulted in the design and fabrication of an IDXP for an upcoming Z experiment that will be the first-ever X-pinch fielded on Z. We have also pursued the development of two additional technologies. First, the extended convolute post (XCP) has been developed as an alternate method for powering diagnostic X-pinches on Z. This concept, which directly couples the current owing in one of the twelve Z convolute posts to an X-pinch, greatly increases the amount of available current relative to an IDXP (900 kA versus 150 kA). Initial short-circuit XCP experiments have demonstrated the efficacy of power ow in this geometry. The second technology pursued here is the inductively driven transmission line (IDTL) current monitor. These low-current IDTLs seek to measure the current in the final power feed with high fidelity. After three generations of development, IDTL current monitors frequently return cleaner current measurements than the standard B-dot sensors that are fielded on Z. This is especially true on high-inductance experiments where the harshest conditions are created in the nal power feed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing river corridor science beyond disciplinary boundaries with an inductive approach to catalyse hypothesis generation

Abstract A unified conceptual framework for river corridors requires synthesis of diverse site‐, method‐ and discipline‐specific findings. The river research community has developed a substantial body of observations and process‐specific interpretations, but we are still lacking a comprehensive model to distill this knowledge into fundamental transferable concepts. We confront the challenge of how a discipline classically organized around the deductive model of systematically collecting of site‐, scale‐, and mechanism‐specific observations begins the process of synthesis. Machine learning is particularly well‐suited to inductive generation of hypotheses. In this study, we prototype an inductive approach to holistic synthesis of river corridor observations, using support vector machine regression to identify potential couplings or feedbacks that would not necessarily arise from classical approaches. This approach generated 672 relationships linking a suite of 157 variables each measured at 62 locations in a fifth order river network. Eighty four percent of these relationships have not been previously investigated, and representing potential (hypothetical) process connections. We document relationships consistent with current understanding including hydrologic exchange processes, microbial ecology, and the River Continuum Concept, supporting that the approach can identify meaningful relationships in the data. Moreover, we highlight examples of two novel research questions that stem from interpretation of inductively‐generated relationships. This study demonstrates the implementation of machine learning to sieve complex data sets and identify a small set of candidate relationships that warrant further study, including data types not commonly measured together. This structured approach complements traditional modes of inquiry, which are often limited by disciplinary perspectives and favour the careful pursuit of parsimony. Finally, we emphasize that this approach should be viewed as a complement to, rather than in place of, more traditional, deductive approaches to scientific discovery.

54 ENVIRONMENTAL SCIENCES↗

A Green's Function Wind Turbine Induction Model That Incorporates Complex Inflow Conditions

ABSTRACT In this work, we develop a new analytical turbine induction model that can incorporate complex inflow conditions including cases where the wind velocity and temperature profiles can vary as functions of height. This induction model is derived from the linearized Navier–Stokes and leads to a second‐order ODE that can be solved using a Green's function formulation. The corresponding Green's function for several configurations are found including the infinite domain, semi‐infinite domain with ground plane, and a power law velocity inflow profile. The results of this approach are then compared with simulations of the turbine induction field using the AMR‐Wind CFD solver with a uniformly loaded actuator disk model. These comparisons show that the Green's function approach captures the centerline blockage, three‐dimensional blockage flow field, and streamwise velocity slow down, with very good agreement for lower thrust conditions and at larger distances away from rotor disk. The effects of shear on the turbine blockage were also compared using a power law inflow profile, and we show that this approach matches the CFD predictions for the cases considered.

17 WIND ENERGY↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗