Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Image reconstruction by parametric cubic convolution

Cubic convolution, which has been discussed by Rifman and McKinnon (1974), was originally developed for the reconstruction of Landsat digital images. In the present investigation, the reconstruction properties of the one-parameter family of cubic convolution interpolation functions are considered and thee image degradation associated with reasonable choices of this parameter is analyzed. With the aid of an analysis in the frequency domain it is demonstrated that in an image-independent sense there is an optimal value for this parameter. The optimal value is not the standard value commonly referenced in the literature. It is also demonstrated that in an image-dependent sense, cubic convolution can be adapted to any class of images characterized by a common energy spectrum.

Park, S. K.↗

Extracellular vesicles of calcifying turkey leg tendon characterized by immunocytochemistry and high voltage electron microscopic tomography and 3-D graphic image reconstruction

To gain insight into the structure and possible function of extracellular vesicles in certain calcifying vertebrate tissues, normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo, have been studied in two separate investigations, one concerning the electron microscopic immunolocalization of the 66 kDa phosphoprotein, osteopontin, and the other detailing the organization and distribution of mineral crystals associated with the vesicles as determined by high voltage microscopic tomography and 3-D graphic image reconstruction. Immunolabeling shows that osteopontin is related to extracellular vesicles of the tendon in the sense that its initial presence appears coincident with the development of mineral associated with the vesicle loci. By high voltage electron microscopy and 3-D imaging techniques, mineral crystals are found to consist of small irregularly shaped particles somewhat randomly oriented throughout individual vesicles sites. Their appearance is different from that found for the mineral observed within calcifying tendon collagen, and their 3-D disposition is not regularly ordered. Possible spatial and temporal relationships of vesicles, osteopontin, mineral, and collagen are being examined further by these approaches.

NASA Discipline Musculoskeletal↗

Hybrid-dual-fourier tomographic algorithm for a fast three-dimensionial optical image reconstruction in turbid media

A reconstruction technique for reducing computation burden in the 3D image processes, wherein the reconstruction procedure comprises an inverse and a forward model. The inverse model uses a hybrid dual Fourier algorithm that combines a 2D Fourier inversion with a 1D matrix inversion to thereby provide high-speed inverse computations. The inverse algorithm uses a hybrid transfer to provide fast Fourier inversion for data of multiple sources and multiple detectors. The forward model is based on an analytical cumulant solution of a radiative transfer equation. The accurate analytical form of the solution to the radiative transfer equation provides an efficient formalism for fast computation of the forward model.

Alfano, Robert R.↗

Acquisition of quantitative physiological data and computerized image reconstruction using a single scan TV system

Single scan operation of television X-ray fluoroscopic systems allow both analog and digital reconstruction of tomographic sections from single plan images. This type of system combined with a minimum of statistical processing showed excellent capabilities for delineating small changes in differential X-ray attenuation. Patient dose reduction is significant when compared to normal operation or film recording. Flat screen, low light level systems were both rugged and light in weight, making them applicable for a variety of special purposes. Three dimensional information was available from the tomographic methods and the recorded data was sufficient when used with appropriate computer display devices to give representative 3D images.

Baily, N. A.↗

Image reconstruction of IRAS survey scans

The IRAS survey data can be used successfully to produce images of extended objects. The major difficulties, viz. non-uniform sampling, different response functions for each detector, and varying signal-to-noise levels for each detector for each scan, were resolved. The results of three different image construction techniques are compared: co-addition, constrained least squares, and maximum entropy. The maximum entropy result is superior. An image of the galaxy M51 with an average spatial resolution of 45 arc seconds is presented, using 60 micron survey data. This exceeds the telescope diffraction limit of 1 minute of arc, at this wavelength. Data fusion is a proposed method for combining data from different instruments, with different spacial resolutions, at different wavelengths. Data estimates of the physical parameters, temperature, density and composition, can be made from the data without prior image (re-)construction. An increase in the accuracy of these parameters is expected as the result of this more systematic approach.

Bontekoe, Tj. Romke↗

Studies on image compression and image reconstruction

During this six month period our works concentrated on three, somewhat different areas. We looked at and developed a number of error concealment schemes for use in a variety of video coding environments. This work is described in an accompanying (draft) Masters thesis. In the thesis we describe application of this techniques to the MPEG video coding scheme. We felt that the unique frame ordering approach used in the MPEG scheme would be a challenge to any error concealment/error recovery technique. We continued with our work in the vector quantization area. We have also developed a new type of vector quantizer, which we call a scan predictive vector quantization. The scan predictive VQ was tested on data processed at Goddard to approximate Landsat 7 HRMSI resolution and compared favorably with existing VQ techniques. A paper describing this work is included. The third area is concerned more with reconstruction than compression. While there is a variety of efficient lossless image compression schemes, they all have a common property that they use past data to encode future data. This is done either via taking differences, context modeling, or by building dictionaries. When encoding large images, this common property becomes a common flaw. When the user wishes to decode just a portion of the image, the requirement that the past history be available forces the decoding of a significantly larger portion of the image than desired by the user. Even with intelligent partitioning of the image dataset, the number of pixels decoded may be four times the number of pixels requested. We have developed an adaptive scanning strategy which can be used with any lossless compression scheme and which lowers the additional number of pixels to be decoded to about 7 percent of the number of pixels requested! A paper describing these results is included.

Sayood, Khalid↗

Acquisition of quantitative physiological data and computerized image reconstruction using a single scan TV system

A single-scan radiography system has been interfaced to a minicomputer, and the combined system has been used with a variety of fluoroscopic systems and image intensifiers available in clinical facilities. The system's response range is analyzed, and several applications are described. These include determination of the gray scale for typical X-ray-fluoroscopic-television chains, measurement of gallstone volume in patients, localization of markers or other small anatomical features, determinations of organ areas and volumes, computer reconstruction of tomographic sections of organs in motion, and computer reconstruction of transverse axial body sections from fluoroscopic images. It is concluded that this type of system combined with a minimum of statistical processing shows excellent capabilities for delineating small changes in differential X-ray attenuation.

Baily, N. A.↗

Incorporation of spatial information in Bayesian image reconstruction - The maximum residual likelihood criterion

We have developed a new figure of merit, a 'maximum-residual-likelihood' (MRL) statistic, for the goodness of fit for Bayesian image restoration which explicitly incorporates spatial information. The MRL constraint provides a natural means of incorporating the prior knowledge that the residuals contain no spatial structure through the autocorrelation function of the residuals. We demonstrate that this statistic follows a Chi-square distribution and that forcing this statistic to have its most probable value leads to a restored image whose residuals are consistent with the noise model. Our numerical experiments suggest that image restoration using the MRL statistic alone is numerically robust and produces results which are independent of the initial guess for the restored image. However, we caution that using the MRL statistic without an image prior can result in overresolution in low SNR portions of the image.

Pina, R. K.↗

Image reconstruction from multiple 1-D scans using filtered localized projection

The spatial resolution that can be attained using scanning linear arrays (consisting of discrete IR solid-state detectors) for image acquisition is considered, and a filtered local projection (FLP) method is described which efficiently combines all available scan information into one rectangular grid without the need for explicit interpolation. Mathematically, the FLP algorithm consists of a localized summation followed by an inverse-filter operation, and it has application to nonlinear restoring techniques. The present method is applied, using a linear array, to simulated data for staggered parallel scans and to multiple scan directions. Noise effects and limitations of the technique are also considered.

Frieden, B. Roy↗

Flaw Detection for Composite Materials Improved by Advanced Thermal Image Reconstruction Techniques

The development of advanced composite materials for use in space and propulsion components has seen considerable growth over the past few years. In addition to improvements that have been made in material properties and processing techniques, similar growth must be seen in the development of methods for the detection of flaws, either generated in service or during manufacturing. Thermal imaging techniques have proven to be successful for the nondestructive evaluation (NDE) of composite materials, but their detection capabilities decrease as flaw depth increases. The purpose of this research is to investigate advanced thermal imaging methods and thermal image processing technologies to increase the maximum depth below surface that a flaw can be detected and improve the contrast between flawed regions and sound regions.

Martin, Richard E.↗

Mineral and organic matrix interaction in normally calcifying tendon visualized in three dimensions by high-voltage electron microscopic tomography and graphic image reconstruction

To define the ultrastructural accommodation of mineral crystals by collagen fibrils and other organic matrix components during vertebrate calcification, electron microscopic 3-D reconstructions were generated from the normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo. Embedded specimens containing initial collagen mineralizing sites were cut into 0.5-micron-thick sections and viewed and photographed at 1.0 MV in the Albany AEI-EM7 high-voltage electron microscope. Tomographic 3-D reconstructions were computed from a 2 degree tilt series of micrographs taken over a minimum angular range of +/- 60 degrees. Reconstructions of longitudinal tendon profiles confirm the presence of irregularly shaped mineral platelets, whose crystallographic c-axes are oriented generally parallel to one another and directed along the collagen long axes. The reconstructions also corroborate observations of a variable crystal length (up to 170 nm measured along crystallographic c-axes), the presence of crystals initially in either the hole or overlap zones of collagen, and crystal growth in the c-axis direction beyond these zones into adjacent overlap and other hole regions. Tomography shows for the first time that crystal width varies (30-45 nm) but crystal thickness is uniform (approximately 4-6 nm at the resolution limit of tomography); more crystals are located in the collagen hole zones than in the overlap regions at the earliest stages of tendon mineralization; the crystallographic c-axes of the platelets lie within +/- 15-20 degrees of one another rather than being perfectly parallel; adjacent platelets are spatially separated by a minimum of 4.2 +/- 1.0 nm; crystals apparently fuse in coplanar alignment to form larger platelets; development of crystals in width occurs to dimensions beyond single collagen hole zones; and a thin envelope of organic origin may be present along or just beneath the surfaces of individual mineral platelets. Implicit in the results is that the formation of crystals occurs at different sites and times by independent nucleation events in local regions of collagen. These data provide the first direct visual evidence from 3-D imaging describing the size, shape, orientation, and growth of mineral crystals in association with collagen of a normally mineralizing vertebrate tissue. They support concepts that c-axial crystal growth is unhindered by collage hole zone dimensions, that crystals are organized in the tendon in a series of generally parallel platelets, and that crystal growth in width across collagen fibrils may follow channels or grooves formed by adjacent hole zones in register.

Non-NASA Center↗

Speckle interferometry of asteroids. IV - Reconstructed images of 4 Vesta

The images of 4 Vesta obtained by means of speckle interferometric observations on November 16 and 17, 1983, support a 5-hr 20.5-min rotational period. The 4 Vesta visible light curve was approximately matched by the placing of circular 'spots' with 135-km diameter over the three dark and three bright features, followed by the assigning of albedos of 0 to the dark spots and 2 to the bright. The light curve is found to be primarily defined by albedo structure, rather than shape; this results in one maximum and one minimum/rotation, rather than the two of each that would be associated with 4 Vesta's triaxial ellipsoid morphology.

Drummond, J.↗

Influence of atmospherically induced random wave fronts on diffraction imagery - A computer simulation model for testing image reconstruction algorithms

This paper is devoted to the development of a two-dimensional computer-simulation model that is based on the rigid constraints of optical diffraction theory with careful attention paid to the generation of sample realizations of Gaussian-distributed, spatially random, isotropic wave fronts that have zero-mean and prescribed-covariance functions. Given a sample realization of the wave front, the corresponding centered point-spread function and optical-transfer function are evaluated. A detailed study is made of the statistics of random wave-front tilt, point-spread function, modulus squared of transfer function, and phase of transfer function.

Barakat, Richard↗

An assessment of image reconstruction from balloon-borne and the IRAS data

Angular resolution and structural information from the far-infrared mapping of astronomical sources (Galactic star forming regions, spiral galaxies, etc.) made using the TIFR 1 m balloon-borne telescope and the IRAS have been compared. The effective wavelengths of the TIFR two-band photometer are 58 and 150 microns. From IRAS, the survey COADD data, additional observations (AO's) made with the survey detectors with different Macros (DPS, DSD, DPM), as well as the chopped photometric channel (CPC) data have been considered here. The observed signals have been processed using different deconvolution strategies, either based on a maximum entropy method (MEM) developed at TIFR or the HiRes package developed at IPAC. Relative merits of each of these, under different conditions of signal to noise ratio, are highlighted. The following sources have been selected for illustration: Carina complex, W31 region, IRAS 10361-5830 (all Galactic), M101 and M81 (extragalactic). The main conclusions are: far-infrared maps from MEM deconvolution of balloon-borne data have the best angular resolution; MEM deconvolution of IRAS AO's gives resolution comparable to HiRes but with less amount of computation, though the dynamic range in MEM maps is less than in HiRes maps.

Ghosh, S. K.↗