Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Mining”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Islet-selectivity of G-protein coupled receptor ligands evaluated for PET imaging of pancreatic {beta}-cell mass

Highlights: {yields} We screened G-protein coupled receptors for imaging pancreatic. {yields} Database mining and immunohistochemistry identified GPCRs enriched in {beta}-cells. {yields} In vitro and in vivo assays were used to determine exocrine vs endocrine specificity. {yields} GPCR candidates for imaging of {beta}-cell mass are Prokineticin-1R, mGluR5, and GLP-1R. -- Abstract: A critical unmet need exists for methods to quantitatively measure endogenous pancreatic {beta}-cell mass (BCM) for the clinical evaluation of therapies to prevent or reverse loss of BCM and diabetes progression. Our objective was to identify G-protein coupled receptors (GPCRs) that are expressed with a high degree of specificity to islet {beta}-cells for receptor-targeted imaging of BCM. GPCRs enriched in pancreatic islets relative to pancreas acinar and hepatic tissue were identified using a database screen. Islet-specific expression was confirmed by human pancreas immunohistochemistry (IHC). In vitro selectivity assessment was determined from the binding and uptake of radiolabeled ligands to the rat insulinoma INS-1 832/13 cell line and isolated rat islets relative to the exocrine pancreas cell-type, PANC-1. Tail-vein injections of radioligands into rats were used to determine favorable image criteria of in vivo biodistribution to the pancreas relative to other internal organs (i.e., liver, spleen, stomach, and lungs). Database and IHC screening identified four candidate receptors for further in vitro and in vivo evaluation for PET imaging of BCM: prokineticin-1 receptor (PK-1R), metabotropic glutamate receptor type-5 (mGluR5), neuropeptide Y-2 receptor (NPY-2R), and glucagon-like peptide 1 receptor (GLP-1R). In vitro specificity ratios gave the following receptor rank order: PK-1R > GLP-1R > NPY-2R > mGluR5. The biodistribution rank order of selectivity to the pancreas was found to be PK-1R > VMAT2 {approx} GLP-1R > mGluR5. Favorable islet selectivity and biodistribution characteristics suggest several GPCRs as potential targets for PET imaging of pancreatic BCM.

60 APPLIED LIFE SCIENCES↗

A New Pivoting and Iterative Text Detection Algorithm for Biomedical Images

There is interest to expand the reach of literature mining to include the analysis of biomedical images, which often contain a paper's key findings. Examples include recent studies that use Optical Character Recognition (OCR) to extract image text, which is used to boost biomedical image retrieval and classification. Such studies rely on the robust identification of text elements in biomedical images, which is a non-trivial task. In this work, we introduce a new text detection algorithm for biomedical images based on iterative projection histograms. We study the effectiveness of our algorithm by evaluating the performance on a set of manually labeled random biomedical images, and compare the performance against other state-of-the-art text detection algorithms. We demonstrate that our projection histogram-based text detection approach is well suited for text detection in biomedical images, and that the iterative application of the algorithm boosts performance to an F score of .60. We provide a C++ implementation of our algorithm freely available for academic use.

60 APPLIED LIFE SCIENCES↗

Automated Data Mining of A Proprietary Database System for Physician Quality Improvement

Purpose: Physician practice quality improvement is a subject of intense national debate. This report describes using a software data acquisition program to mine an existing, commonly used proprietary radiation oncology database to assess physician performance. Methods and Materials: Between 2003 and 2004, a manual analysis was performed of electronic portal image (EPI) review records. Custom software was recently developed to mine the record-and-verify database and the review process of EPI at our institution. In late 2006, a report was developed that allowed for immediate review of physician completeness and speed of EPI review for any prescribed period. Results: The software extracted >46,000 EPIs between 2003 and 2007, providing EPI review status and time to review by each physician. Between 2003 and 2007, the department EPI review improved from 77% to 97% (range, 85.4-100%), with a decrease in the mean time to review from 4.2 days to 2.4 days. The initial intervention in 2003 to 2004 was moderately successful in changing the EPI review patterns; it was not repeated because of the time required to perform it. However, the implementation in 2006 of the automated review tool yielded a profound change in practice. Using the software, the automated chart review required {approx}1.5 h for mining and extracting the data for the 4-year period. Conclusion: This study quantified the EPI review process as it evolved during a 4-year period at our institution and found that automation of data retrieval and review simplified and facilitated physician quality improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-E-17A-03: FDG-PET-Based Radiomics to Predict Local Control and Survival Following Radiotherapy

Purpose: An exploding field in cancer research is “radiomics,” based on the hypothesis that there is statistical (hidden) information in medical images that is prognostic or predictive of outcomes. Our group has developed an efficient pipeline to extract and analyze quantitative image features from medical images as related to outcomes or diagnosis. In this work, we summarize our previous studies with positron emission tomography (PET) images and show the potential of the use of radiomics for outcomes research. Methods: We analyzed two cancer datasets, each consisting of pre-radiotherapy-treatment PET scans: 163 T1-2N0M0 non-small cell lung cancer (NSCLC) patients and 174 head and neck (H and N) cancer patients with stage III–IV. The PET scans were converted to Computational Environment for Radiological Research (CERR) format, and CERR was used to generate 24 shape, texture, and intensity-histogram based image features. Data-mining and logistic regression methods were then used to model local failure (LF) and overall survival (OS). Unbiased estimates of performance were generated using leave-one-out cross-validation (LOOCV). Results: For predicting LF, the models with biologically equivalent dose (BED) and TLG (metabolic tumor volume (MTV) x SUVmean) in NSCLC, and skewness and MTV in H and N, achieved the best performance with AUC=0.818 (p<0.0001) and AUC=0.826 (p=0.0002), respectively. For predicting OS, the models with kurtosis and volume in NSCLC and SUVmax and homogeneity in H and N achieved the best performance with AUC=0.706 (p<0.0001) and AUC=0.656 (p=0.0003), respectively. On LOOCV, all these models retained significant predictive power. Interestingly, MTV was highly correlated with LF in both sites. Conclusion: PET-based imaged features are promising tools for improving treatment management decision making. Much more research is needed to identify optimal radiomics metrics and to correlate imaging phenotype with other clinical or genomic information.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-10: Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation

Purpose: Recent advances in medical imaging technologies provide opportunities to quantify the tumor phenotype throughout the course of treatment non-invasively. The emerging field of Radiomics addresses this by converting medical images into minable data by applying a large number of quantitative imaging algorithms. Accurate tumor segmentation is one of the main challenges of Radiomics. It has been shown that semiautomatic segmentation approaches efficiently reduce inter-observer variability as compared to the time consuming manual delineations. In this study, a semiautomatic volumetric segmentation algorithm, implemented in the free and publicly available 3D-Slicer platform, was investigated in terms of its robustness for Radiomics features quantification. Methods: Fifty-six 3D-Radiomics features, quantifying phenotypic differences based on the tumor intensity, shape and texture, were extracted from the computed tomography images of twenty lung cancer patients. These Radiomics features were derived from the 3D-tumor volumes defined by three independent observers twice using 3D-Slicer, and compared to manual slice-by-slice delineations of five independent physicians in terms of intra-class correlation coefficient (ICC) and feature range. Results: Radiomics features extracted from 3D-Slicer segmentations had significantly higher reproducibility (ICC= 0.85 0.15, p=0.0009) compared to the features extracted from the manual segmentations (ICC= 0.77 0.17). Furthermore, the features extracted from 3D-Slicer based segmentations, spread over significantly smaller range across observers as compared to those of the manual delineations (p= 3.819e-07). Moreover, the features derived from 3D-Slicer segmentations overlapped in range with those of the manual delineations, as the lower(higher) limit(s) being significantly higher(lower) for the 3D-Slicer features (p= 0.007, p= 5.863e-06). Conclusion: 3D-Slicer based semiautomatic segmentation significantly improves the robustness of radiomics features and thus could serve as a potential alternative to the time consuming manual segmentation process. So 3D-Slicer can have a large application in Radiomics, and be employed for high-throughput data mining research of medical imaging in clinical oncology.

60 APPLIED LIFE SCIENCES↗

EGS Collab Experiment 2: Testbed Well Orientation Data

This dataset contains the north seeking gyro data for each of the 11 boreholes drilled at the Experiment 2 testbed on the 4100 foot level of the SURF (Sanford Underground Research Facility). Each gyro file is in individual folders for each well. A single folder called 'E2 All Well Trajectories' contains the trajectories for all the wells but in the mine coordinate system. An image of the well layout is provided in a PowerPoint.

15 GEOTHERMAL ENERGY↗

Passive seismic tomography application for cave monitoring in DOZ underground mine PT. Freeport Indonesia

It is already known that tomography has a great impact for analyzing and mapping unknown objects based on inversion, travel time as well as waveform inversion. Therefore, tomography has used in wide area, not only in medical but also in petroleum as well as mining. Recently, tomography method is being applied in several mining industries. A case study of tomography imaging has been carried out in DOZ ( Deep Ore Zone ) block caving mine, Tembagapura, Papua. Many researchers are undergoing to investigate the properties of DOZ cave not only outside but also inside which is unknown. Tomography takes a part for determining this objective.The sources are natural from the seismic events that caused by mining induced seismicity and rocks deformation activity, therefore it is called as passive seismic. These microseismic travel time data are processed by Simultaneous Iterative Reconstruction Technique (SIRT). The result of the inversion can be used for DOZ cave monitoring. These information must be used for identifying weak zone inside the cave. In addition, these results of tomography can be used to determine DOZ and cave information to support mine activity in PT. Freeport Indonesia.

58 GEOSCIENCES↗

Quantitative multi-modal NDT data analysis

A single NDT technique is often not adequate to provide assessments about the integrity of test objects with the required coverage or accuracy. In such situations, it is often resorted to multi-modal testing, where complementary and overlapping information from different NDT techniques are combined for a more comprehensive evaluation. Multi-modal material and defect characterization is an interesting task which involves several diverse fields of research, including signal and image processing, statistics and data mining. The fusion of different modalities may improve quantitative nondestructive evaluation by effectively exploiting the augmented set of multi-sensor information about the material. It is the redundant information in particular, whose quantification is expected to lead to increased reliability and robustness of the inspection results. There are different systematic approaches to data fusion, each with its specific advantages and drawbacks. In our contribution, these will be discussed in the context of nondestructive materials testing. A practical study adopting a high-level scheme for the fusion of Eddy Current, GMR and Thermography measurements on a reference metallic specimen with built-in grooves will be presented. Results show that fusion is able to outperform the best single sensor regarding detection specificity, while retaining the same level of sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperspectral Cathodoluminescence of Bastnäsite at the Mountain Pass Mine, USA: Implications for REE Mineralisation and Mining

This study uses micro-analyses including hyperspectral cathodoluminescence to image and obtain mineral spectral to help evaluate REE deportment via from Mountain Pass Mine in California. It presents the first known CL-based spectra for bastnäsite, new information regarding baryte CL spectra, providing insights on the coeval and spatial relationship between REE, Ba, and S in carbonatite systems. Bastnäsite, baryte, and monazite are often intergrown in both brecciated, “blue ore” samples, and these minerals occur as an apparent intercumulus texture in the dolomite-rich, “white ore” samples. Bastnäsite luminescence is present, but very low compared to baryte in the visible spectrum. Bastnäsite illustrates some textural variability related to its main luminescent peak ~1.4 eV, which is indicative of Nd3+. It also exhibits several other small peaks comprised of multiple activators related to various REE, including Ce3+, Sm3+, Eu3+, and potentially Eu2+. Baryte displays textures of variable complexity but often with darker rims near crystal margins. It luminesces mainly at 1.4-1.52 eV, 2.05 eV, and 3.59-4.08 eV. The 2.05 eV peak is likely attributed to Ag+, but the other peaks are more enigmatic.

58 - GEOSCIENCES↗

Revealing latent pole and zone line information in atom probe detector maps using crystallographically correlated metrics

Poles and zone lines observed within atom probe field evaporation images are useful for a range of atom probe crystallography studies, including calibration of the reconstruction and crystallographic characterisation of microstructural features such as grain boundaries. However, this information is not always readily apparent. Techniques for plotting crystallographically correlated metrics contained within atom probe data to enhance pole and zone line contrast across the detector space are developed. This includes consideration of the electric field, molecular ions, lattice structure retained within the reconstruction, specific elemental species, the number of pulses between detection events, and the lateral distance between sequential detection events. These approaches are then applied to experimental atom probe tomography datasets on technically pure Al, nanocrystalline Al, highly doped Si, and additively manufactured Inconel 738, Haynes 282, and Ti–6Al–4V. The results facilitate the extension of atom probe crystallography studies to a broader range of crystalline datasets where crystallographic information is not readily apparent from existing methods, as well as a deeper understanding of field evaporation behaviour during an atom probe experiment.

47 OTHER INSTRUMENTATION↗

Computer vision-based rock bolt detection in orthomosaic imagery obtained in the Waste Isolation Pilot Plant underground facility

Assessing structural integrity of large underground tunnel facilities is often a time consuming and human-labor intensive task. Thus, research using various modes of sensing and automated detection of key structural components in mines is posed to aid in safety assessments and establishing overall structural health. We propose an approach utilizing off-the-shelf camera and lidar technology fixed to a custom sensing platform, image stitching techniques, fine-tuned object detection models, and specialized model-inference methods to automatically detect, count, and map roof bolts for assessment of structural safety in man-made underground tunnels. Results show a novel workflow for effective object counting in orthomosaic tunnel ceiling images generated from collections in GPS-denied mining environments. Additionally, we demonstrate effective fine-tuning of EfficientDet object detectors utilizing state-of-the-art image augmentation techniques known as the mosaic and mixup transformations. Our work is demonstrated on sensed data and imagery collected from the Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) where miles of tunnel ceiling must be assessed for structural integrity.

42 ENGINEERING↗

A framework for activity detection in wide-area motion imagery

Wide-area persistent imaging systems are becoming increasingly cost effective and now large areas of the earth can be imaged at relatively high frame rates (1-2 fps). The efficient exploitation of the large geo-spatial-temporal datasets produced by these systems poses significant technical challenges for image and video analysis and data mining. In recent years there has been significant progress made on stabilization, moving object detection and tracking and automated systems now generate hundreds to thousands of vehicle tracks from raw data, with little human intervention. However, the tracking performance at this scale, is unreliable and average track length is much smaller than the average vehicle route. This is a limiting factor for applications which depend heavily on track identity, i.e. tracking vehicles from their points of origin to their final destination. In this paper we propose and investigate a framework for wide-area motion imagery (W AMI) exploitation that minimizes the dependence on track identity. In its current form this framework takes noisy, incomplete moving object detection tracks as input, and produces a small set of activities (e.g. multi-vehicle meetings) as output. The framework can be used to focus and direct human users and additional computation, and suggests a path towards high-level content extraction by learning from the human-in-the-loop.

99 GENERAL AND MISCELLANEOUS↗

High-resolution Urban Image Classification Using Extended Features

High-resolution image classification poses several challenges because the typical object size is much larger than the pixel resolution. Any given pixel (spectral features at that location) by itself is not a good indicator of the object it belongs to without looking at the broader spatial footprint. Therefore most modern machine learning approaches that are based on per-pixel spectral features are not very effective in high- resolution urban image classification. One way to overcome this problem is to extract features that exploit spatial contextual information. In this study, we evaluated several features in- cluding edge density, texture, and morphology. Several machine learning schemes were tested on the features extracted from a very high-resolution remote sensing image and results were presented.

99 GENERAL AND MISCELLANEOUS↗

Big Biomedical data as the key resource for discovery science

Modern biomedical data collection is generating exponentially more data in a multitude of formats. This flood of complex data poses significant opportunities to discover and understand the critical interplay among such diverse domains as genomics, proteomics, metabolomics, and phenomics, including imaging, biometrics, and clinical data. The Big Data for Discovery Science Center is taking an “-ome to home” approach to discover linkages between these disparate data sources by mining existing databases of proteomic and genomic data, brain images, and clinical assessments. In support of this work, the authors developed new technological capabilities that make it easy for researchers to manage, aggregate, manipulate, integrate, and model large amounts of distributed data. Guided by biological domain expertise, the Center’s computational resources and software will reveal relationships and patterns, aiding researchers in identifying biomarkers for the most confounding conditions and diseases, such as Parkinson’s and Alzheimer’s.

Alzheimer's disease (ID)↗

Detecting and monitoring UCG subsidence with InSAR

The use of interferometric synthetic aperture radar (InSAR) to measure surface subsidence caused by Underground Coal Gasification (UCG) is tested. InSAR is a remote sensing technique that uses Synthetic Aperture Radar images to make spatial images of surface deformation and may be deployed from satellite or an airplane. With current commercial satellite data, the technique works best in areas with little vegetation or farming activity. UCG subsidence is generally caused by roof collapse, which adversely affects UCG operations due to gas loss and is therefore important to monitor. Previous studies have demonstrated the usefulness of InSAR in measuring surface subsidence related to coal mining and surface deformation caused by a coal mining roof collapse in Crandall Canyon, Utah is imaged as a proof-of-concept. InSAR data is collected and processed over three known UCG operations including two pilot plants (Majuba, South Africa and Wulanchabu, China) and an operational plant (Angren, Uzbekistan). A clear f eature showing approximately 7 cm of subsidence is observed in the UCG field in Angren. Subsidence is not observed in the other two areas, which produce from deeper coal seams and processed a smaller volume. The results show that in some cases, InSAR is a useful tool to image UCG related subsidence. Data from newer satellites and improved algorithms will improve effectiveness.

01 COAL, LIGNITE, AND PEAT↗

Automated electrosynthesis reaction mining with multimodal large language models (MLLMs)

Leveraging the chemical data available in legacy formats such as publications and patents is a significant challenge for the community. Automated reaction mining offers a promising solution to unleash this knowledge into a learnable digital form and therefore help expedite materials and reaction discovery. However, existing reaction mining toolkits are limited to single input modalities (text or images) and cannot effectively integrate heterogeneous data that is scattered across text, tables, and figures. In this work, we go beyond single input modalities and explore multimodal large language models (MLLMs) for the analysis of diverse data inputs for automated electrosynthesis reaction mining. We compiled a test dataset of 65 articles (MERMES-T24 set) and employed it to benchmark five prominent MLLMs against two critical tasks: (i) reaction diagram parsing and (ii) resolving cross-modality data interdependencies. The frontrunner MLLM achieved ≥96% accuracy in both tasks, with the strategic integration of single-shot visual prompts and image pre-processing techniques. We integrate this capability into a toolkit named MERMES (multimodal reaction mining pipeline for electrosynthesis). Our toolkit functions as an end-to-end MLLM-powered pipeline that integrates article retrieval, information extraction and multimodal analysis for streamlining and automating knowledge extraction. This work lays the groundwork for the increased utilization of MLLMs to accelerate the digitization of chemistry knowledge for data-driven research.

Leong, Shi Xuan↗

The art and power of data imaging

Data imaging and visual data assessment are veritable gold mines in the scientist's quest to understand and accurately interpret numerical data. Graphical displays of various aspects of a dataset offer the analyst insight to the data that no mathematical computation or statistic can provide. It is difficult, at best, for even a skilled and observant statistician to understand the underlying structure of a dataset. Often, there is either too little data to get a good 'picture' of the structure that might be present or there is so much data that one cannot readily assimilate it. Of course, the latter problem (too much data) is, in reality, no problem at all given the abilities of modern computers and software systems to manage large amounts of data. Advances in computer technology and the advent of the global positioning satellite system have enabled scientists from many fields of endeavor to collect and view data in its spatial context. Visual images constructed from spatially referenced data reveal the inherent richness and structure in the data and lead to more informed conclusions. So powerful is data collected with spatial context that a relatively new branch of mathematical statistics, geo-spatial statistics, has emerged. Geo-spatial statistics seek to exploit this context rich data form to better understand the spatial and co-relationships that might exist, but would be otherwise hidden in tabular data or obscured with classic statistical approaches. This paper (and accompanying presentation) will show the power that visual data assessment possesses to understand radiological scanning data and to make confident and accurate decisions based on the data images. It will challenge the traditional mathematical concept of detection limits for scanning. It will demonstrate that more data, even if the individual datum comprising the dataset is of 'poorer quality' (i.e., has a larger uncertainty and, thus, a larger calculated minimum detection value), is significantly more powerful than a smaller dataset comprised of higher quality measurements. This presentation will cause the open-minded health physicist to rethink how they prescribe, collect, evaluate, and make decisions based upon radiological scan data. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applying Electrical Resistivity Tomography in Ornamental Stone Mining: Challenges and Solutions

In this study, the use of electrical resistivity tomography (ERT) as a tool to guide ornamental stone extraction is investigated. ERT is not conventionally used in highly resistive environments, such as on rock faces, due to the high contact resistances that can impede current injection. Here, the challenges of conducting ERT in such environments are discussed and possible solutions suggested. For this, an example of the application of ERT in a deep and narrow marble quarry is used. The marble deposit is affected by fracturing and karstification. Due to the nature of these features, they present a significant resistivity contrast to the background resistivity of the marble and thus excellent targets to test the application of ERT. Their location was mapped using field observations and complementary ground penetrating radar data. By using an appropriate sensor deployment, a suitable resistivity meter, and advanced data processing routines, the derived 3D resistivity model is in good agreement with the independent observations. This shows that despite the challenges, ERT can be used as a non-invasive tool to obtain information on the stone properties prior to extraction. This will help in guiding quarry operations and will allow for a targeted, safe and efficient extraction of high quality stone, thereby increasing sustainability and economical competitiveness.

58 GEOSCIENCES↗