Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optical doping of Al{sub x}Ga{sub 1-x}N compounds by ion implantation of Tm ions

Al{sub x}Ga{sub 1-x}N (0 axis for samples with AlN contents of 0.15 and 0.77 suggest a relation between the AlN content and Tm specific sites in the lattice. Rapid thermal annealing treatments under N{sub 2} ambient were performed to remove damage and promote optical activation of rare earth intra-4f{sup n} transitions. After annealing the observed intraionic emissions of Tm{sup 3+} ions were characterized by photoluminescence.

36 MATERIALS SCIENCE↗

Plasma immersion ion implantation for reducing metal ion release

Plasma immersion ion implantation of Nitrogen and Oxygen on CoCrMo alloys was carried out to improve the tribological and corrosion behaviors of these biomedical alloys. In order to optimize the implantation results we were carried experiments at different temperatures. Tribocorrosion tests in bovine serum were used to measure Co, Cr and Mo releasing by using Inductively Coupled Plasma Mass Spectrometry analysis after tests. Also, X-ray Diffraction analysis were employed in order to explain any obtained difference in wear rate and corrosion tests. Wear tests reveals important decreases in rate of more than one order of magnitude for the best treatment. Moreover decreases in metal release were found for all the implanted samples, preserving the same corrosion resistance of the unimplanted samples. Finally this paper gathers an analysis, in terms of implantation parameters and achieved properties for industrial implementation of these treatments.

36 MATERIALS SCIENCE↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ion sources for ion implantation technology (invited)

Ion sources for ion implantation are introduced. The technique is applied not only to large scale integration (LSI) devices but also to flat panel display. For LSI fabrication, ion source scheduled maintenance cycle is most important. For CMOS image sensor devices, metal contamination at implanted wafer is most important. On the other hand, to fabricate miniaturized devices, cluster ion implantation has been proposed to make shallow PN junction. While for power devices such as silicon carbide, aluminum ion is required. For doping processes of LCD fabrication, a large ion source is required. The extraction area is about 150 cm × 10 cm, and the beam uniformity is important as well as the total target beam current.

43 PARTICLE ACCELERATORS↗

Fabrication and characterization of a co-planar detector in diamond for low energy single ion implantation

We demonstrate low energy single ion detection using a co-planar detector fabricated on a diamond substrate and characterized by ion beam induced charge collection. Histograms are taken with low fluence ion pulses illustrating quantized ion detection down to a single ion with a signal-to-noise ratio of approximately 10. We anticipate that this detection technique can serve as a basis to optimize the yield of single color centers in diamond. In conclusion, the ability to count ions into a diamond substrate is expected to reduce the uncertainty in the yield of color center formation by removing Poisson statistics from the implantation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a microwave ion source for ion implantations

A microwave ion source is expected to have a long lifetime, as it has fewer consumables. Thus, we are in the process of developing a microwave ion source for ion implantation applications. In this paper, we report on a newly developed plasma chamber and the extracted P{sup +} beam currents. The volume of the plasma chamber is optimized by varying the length of a boron nitride block installed within the chamber. The extracted P{sup +} beam current is more than 30 mA, at a 25 kV acceleration voltage, using PH{sub 3} gas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of BF{sub 3} plasma immersion ion implantation into silicon

Plasma immersion ion implantation from a BF{sub 3} plasma into crystalline (100) silicon was performed using the PULSION plasma doping tool. Implanted boron profiles were measured with the SIMS method and simulated using models with different levels of sophistication. The physical implantation model is based on an analytical energy distribution for ions from the plasma and uses a Monte-Carlo simulation code. An analytical model of plasma immersion ion implantation that assumes a uniform and isotropic implantation was implemented in a software module called IMP3D. The functionality of this module which was initially envisaged for the three-dimensional simulation of conventional ion implantation was extended to plasma immersion ion implantation and examples of 2D and 3D simulations from this are presented.

36 MATERIALS SCIENCE↗

Characterization of an RF plasma ion source for ion implantation

A novel inductively coupled RF plasma ion source has been developed for use in a beamline ion implanter. Ion density data have been taken with an array of four Langmuir probes spaced equally at the source extraction arc slit. These provide ion density uniformity information as a function of source pressure, RF power and gas mixture composition. In addition, total extracted ion beam current data are presented for the same conditions. The comparative advantages of the RF source in terms of higher beam current, reduced maintenance and overall productivity improvement compared to a hot cathode source are discussed.

43 PARTICLE ACCELERATORS↗

Enhanced life ion source for germanium and carbon ion implantation

Germanium and carbon ions represent a significant portion of total ion implantation steps in the process flow. Very often ion source materials that used to produce ions are chemically aggressive, especially at higher temperatures, and result in fast ion source performance degradation and a very limited lifetime [B.S. Freer, et. al., 2002 14th Intl. Conf. on Ion Implantation Technology Proc, IEEE Conf. Proc., p. 420 (2003)]. GeF{sub 4} and CO{sub 2} are commonly used to generate germanium and carbon beams. In the case of GeF{sub 4} controlling the tungsten deposition due to the de-composition of WF{sub 6} (halogen cycle) is critical to ion source life. With CO{sub 2}, the materials oxidation and carbon deposition must be controlled as both will affect cathode thermionic emission and anti-cathode (repeller) efficiencies due to the formation of volatile metal oxides. The improved ion source design Extended Life Source 3 (Eterna ELS3) together with its proprietary co-gas material implementation has demonstrated >300 hours of stable continuous operation when using carbon and germanium ion beams. Optimizing cogas chemistries retard the cathode erosion rate for germanium and carbon minimizes the adverse effects of oxygen when reducing gas is introduced for carbon. The proprietary combination of hardware and co-gas has improved source stability and the results of the hardware and co-gas development are discussed.

36 MATERIALS SCIENCE↗

Diffusion mechanism and the thermal stability of fluorine ions in GaN after ion implantation

The diffusion mechanisms of fluorine ions in GaN are investigated by means of time-of-flight secondary ion mass spectrometry. Instead of incorporating fluorine ions close to the sample surface by fluorine plasma treatment, fluorine ion implantation with an energy of 180 keV is utilized to implant fluorine ions deep into the GaN bulk, preventing the surface effects from affecting the data analysis. It is found that the diffusion of fluorine ions in GaN is a dynamic process featuring an initial out-diffusion followed by in- diffusion and the final stabilization. A vacancy-assisted diffusion model is proposed to account for the experimental observations, which is also consistent with results on molecular dynamic simulation. Fluorine ions tend to occupy Ga vacancies induced by ion implantation and diffuse to vacancy rich regions. The number of continuous vacancy chains can be significantly reduced by a dynamic thermal annealing process. As a result, strong local confinement and stabilization of fluorine ions can be obtained in GaN crystal, suggesting excellent thermal stability of fluorine ions for device applications.

36 MATERIALS SCIENCE↗

Formation of Ge nanoparticles in SiO{sub x}N{sub y} by ion implantation and thermal annealing

Germanium nanoparticles embedded within dielectric matrices hold much promise for applications in optoelectronic and electronic devices. Here we investigate the formation of Ge nanoparticles in amorphous SiO{sub 1.67}N{sub 0.14} as a function of implanted atom concentration and thermal annealing temperature. Using x-ray absorption spectroscopy and other complementary techniques, we show Ge nanoparticles exhibit significant finite-size effects such that the coordination number decreases and structural disorder increases as the nanoparticle size decreases. While the composition of SiO{sub 1.67}N{sub 0.14} is close to that of SiO{sub 2}, we demonstrate that the addition of this small fraction of N yields a much reduced nanoparticle size relative to those formed in SiO{sub 2} under comparable implantation and annealing conditions. We attribute this difference to an increase in an atomic density and a much reduced diffusivity of Ge in the oxynitride matrix. These results demonstrate the potential for tailoring Ge nanoparticle sizes and structural properties in the SiO{sub x}N{sub y} matrices by controlling the oxynitride stoichiometry.

36 MATERIALS SCIENCE↗

Experimental results of a dual-beam ion source for 200 keV ion implanter

A dual beam ion source for 200 keV ion implanter aimed to produce 200 keV H{sub 2}{sup +} and He{sup +} beams simultaneously has been developed. Not suitable to use the analyzing magnet, the purity of beam extracted from the source becomes important to the performance of implanter. The performance of ion source was measured. The results of experiments show that the materials of inlet tube of ion source, the time of arc ionization in ion source, and the amount of gas flow have significant influence on the purity of beam. The measures by using copper as inlet tube material, long time of arc ionization, and increasing the inlet of gas flow could effectively reduce the impurity of beam. And the method using the gas mass flow controller to adjust the proportion of H{sub 2}{sup +} and He{sup +} is feasible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source

The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1–10 mm{sup 2}. The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.

36 MATERIALS SCIENCE↗

Surface Oxidation Effects During Low Energy BF{sub 2}{sup +} Ion Implantation

We present results on silicon wafer surface oxidation observed during low energy high dose BF{sub 2}{sup +} implantation. Experiments were performed on single-crystal and pre-amorphized silicon wafers that help elucidate the surface structure impact on boron distribution profiles and dose retention. Implanters with different architectures were compared including both single wafer and batch systems. It was found that the oxidation rate depends on implanter type and design, and that the surface oxide thickness is a linear function of implantation dose and time. Surface oxidation is significantly higher for batch systems compared to single wafer tools. This is due primarily to the significantly lower beam duty cycle on the batch implanter. The oxide thicknesses estimated from SIMS oxygen profiles are in agreement with ellipsometry measurements after spike annealing, and show a similar difference between single wafer and batch implanters. SIMS boron distribution profiles after implantation were compared and used to calculate retained dose. In the medium dose range ({<=}3x10{sup 14} at/cm{sup 2}) the profiles from different implanters are well matched and the dose retention is close to 100%. For the higher dose range ({>=}3x10{sup 15} at/cm{sup 2}) retention for the batch implanter is significantly less than the single wafer tool and depends on the wafer surface structure. A higher oxidation rate results in lower dopant activation and higher Rs value after spike annealing. For high implantation doses the single wafer system allows much higher dose retention and better boron activation after annealing.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗