Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Production technology for high efficiency ion implanted solar cells

Ion implantation is being developed for high volume automated production of silicon solar cells. An implanter designed for solar cell processing and able to properly implant up to 300 4-inch wafers per hour is now operational. A machine to implant 180 sq m/hr of solar cell material has been designed. Implanted silicon solar cells with efficiencies exceeding 16% AM1 are now being produced and higher efficiencies are expected. Ion implantation and transient processing by pulsed electron beams are being integrated with electrostatic bonding to accomplish a simple method for large scale, low cost production of high efficiency solar cell arrays.

Kirkpatrick, A. R.↗

Fabrication and characterization of a co-planar detector in diamond for low energy single ion implantation

We demonstrate low energy single ion detection using a co-planar detector fabricated on a diamond substrate and characterized by ion beam induced charge collection. Histograms are taken with low fluence ion pulses illustrating quantized ion detection down to a single ion with a signal-to-noise ratio of approximately 10. We anticipate that this detection technique can serve as a basis to optimize the yield of single color centers in diamond. In conclusion, the ability to count ions into a diamond substrate is expected to reduce the uncertainty in the yield of color center formation by removing Poisson statistics from the implantation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a microwave ion source for ion implantations

A microwave ion source is expected to have a long lifetime, as it has fewer consumables. Thus, we are in the process of developing a microwave ion source for ion implantation applications. In this paper, we report on a newly developed plasma chamber and the extracted P{sup +} beam currents. The volume of the plasma chamber is optimized by varying the length of a boron nitride block installed within the chamber. The extracted P{sup +} beam current is more than 30 mA, at a 25 kV acceleration voltage, using PH{sub 3} gas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of BF{sub 3} plasma immersion ion implantation into silicon

Plasma immersion ion implantation from a BF{sub 3} plasma into crystalline (100) silicon was performed using the PULSION plasma doping tool. Implanted boron profiles were measured with the SIMS method and simulated using models with different levels of sophistication. The physical implantation model is based on an analytical energy distribution for ions from the plasma and uses a Monte-Carlo simulation code. An analytical model of plasma immersion ion implantation that assumes a uniform and isotropic implantation was implemented in a software module called IMP3D. The functionality of this module which was initially envisaged for the three-dimensional simulation of conventional ion implantation was extended to plasma immersion ion implantation and examples of 2D and 3D simulations from this are presented.

36 MATERIALS SCIENCE↗

Characterization of an RF plasma ion source for ion implantation

A novel inductively coupled RF plasma ion source has been developed for use in a beamline ion implanter. Ion density data have been taken with an array of four Langmuir probes spaced equally at the source extraction arc slit. These provide ion density uniformity information as a function of source pressure, RF power and gas mixture composition. In addition, total extracted ion beam current data are presented for the same conditions. The comparative advantages of the RF source in terms of higher beam current, reduced maintenance and overall productivity improvement compared to a hot cathode source are discussed.

43 PARTICLE ACCELERATORS↗

Enhanced life ion source for germanium and carbon ion implantation

Germanium and carbon ions represent a significant portion of total ion implantation steps in the process flow. Very often ion source materials that used to produce ions are chemically aggressive, especially at higher temperatures, and result in fast ion source performance degradation and a very limited lifetime [B.S. Freer, et. al., 2002 14th Intl. Conf. on Ion Implantation Technology Proc, IEEE Conf. Proc., p. 420 (2003)]. GeF{sub 4} and CO{sub 2} are commonly used to generate germanium and carbon beams. In the case of GeF{sub 4} controlling the tungsten deposition due to the de-composition of WF{sub 6} (halogen cycle) is critical to ion source life. With CO{sub 2}, the materials oxidation and carbon deposition must be controlled as both will affect cathode thermionic emission and anti-cathode (repeller) efficiencies due to the formation of volatile metal oxides. The improved ion source design Extended Life Source 3 (Eterna ELS3) together with its proprietary co-gas material implementation has demonstrated >300 hours of stable continuous operation when using carbon and germanium ion beams. Optimizing cogas chemistries retard the cathode erosion rate for germanium and carbon minimizes the adverse effects of oxygen when reducing gas is introduced for carbon. The proprietary combination of hardware and co-gas has improved source stability and the results of the hardware and co-gas development are discussed.

36 MATERIALS SCIENCE↗

High Curie temperature drive layer materials for ion-implanted magnetic bubble devices

Ion implantation of bubble garnets can lower the Curie temperature by 70 C or more, thus limiting high temperature operation of devices with ion-implanted propagation patterns. Therefore, double-layer materials were made with a conventional 2-micron bubble storage layer capped by an ion-implantable drive layer of high Curie temperature, high magnetostriction material. Contiguous disk test patterns were implanted with varying doses of a typical triple implant. Quality of propagation was judged by quasistatic tests on 8-micron period major and minor loops. Variations of magnetization, uniaxial anisotropy, implant dose, and magnetostriction were investigated to ensure optimum flux matching, good charged wall coupling, and wide operating margins. The most successful drive layer compositions were in the systems (SmDyLuCa)3(FeSi)5O12 and (BiGdTmCa)3(FeSi)5O12 and had Curie temperatures 25-44 C higher than the storage layers.

Fratello, V. J.↗

Ion-probe studies of artificially implanted ions in lunar samples

The ion microprobe at the Johnson Space Center was used to study depth profiles of artificially implanted ions in lunar samples. Five polished sections of typical mare basalts (12040 and 12018) were irradiated with nine different elements at two energies and the resulting concentrations were measured as a function of depth in the minerals plagioclase, pyroxene, and ilmenite. These preliminary simulation experiments were undertaken to determine whether the ion probe can be used to measure solar-wind-implanted elements on the surface of lunar rock crystals and soil grains and to study mechanisms for the redistribution. The results obtained so far demonstrate that depth profiles can indeed be measured with the ion probe. From estimated exposure times of mature soil grains and selected vug crystals, it appears possible (if difficult) to detect several solar-wind-implanted elements.

Zinner, E.↗

Formation of Ge nanoparticles in SiO{sub x}N{sub y} by ion implantation and thermal annealing

Germanium nanoparticles embedded within dielectric matrices hold much promise for applications in optoelectronic and electronic devices. Here we investigate the formation of Ge nanoparticles in amorphous SiO{sub 1.67}N{sub 0.14} as a function of implanted atom concentration and thermal annealing temperature. Using x-ray absorption spectroscopy and other complementary techniques, we show Ge nanoparticles exhibit significant finite-size effects such that the coordination number decreases and structural disorder increases as the nanoparticle size decreases. While the composition of SiO{sub 1.67}N{sub 0.14} is close to that of SiO{sub 2}, we demonstrate that the addition of this small fraction of N yields a much reduced nanoparticle size relative to those formed in SiO{sub 2} under comparable implantation and annealing conditions. We attribute this difference to an increase in an atomic density and a much reduced diffusivity of Ge in the oxynitride matrix. These results demonstrate the potential for tailoring Ge nanoparticle sizes and structural properties in the SiO{sub x}N{sub y} matrices by controlling the oxynitride stoichiometry.

36 MATERIALS SCIENCE↗

Experimental results of a dual-beam ion source for 200 keV ion implanter

A dual beam ion source for 200 keV ion implanter aimed to produce 200 keV H{sub 2}{sup +} and He{sup +} beams simultaneously has been developed. Not suitable to use the analyzing magnet, the purity of beam extracted from the source becomes important to the performance of implanter. The performance of ion source was measured. The results of experiments show that the materials of inlet tube of ion source, the time of arc ionization in ion source, and the amount of gas flow have significant influence on the purity of beam. The measures by using copper as inlet tube material, long time of arc ionization, and increasing the inlet of gas flow could effectively reduce the impurity of beam. And the method using the gas mass flow controller to adjust the proportion of H{sub 2}{sup +} and He{sup +} is feasible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source

The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1–10 mm{sup 2}. The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.

36 MATERIALS SCIENCE↗

Enhancing electrical conductivity and electron field emission properties of ultrananocrystalline diamond films by copper ion implantation and annealing

Copper ion implantation and subsequent annealing at 600 °C achieved high electrical conductivity of 95.0 (Ωcm){sup −1} for ultrananocrystalline diamond (UNCD) films with carrier concentration of 2.8 × 10{sup 18} cm{sup −2} and mobility of 6.8 × 10{sup 2} cm{sup 2}/V s. Transmission electron microscopy examinations reveal that the implanted Cu ions first formed Cu nanoclusters in UNCD films, which induced the formation of nanographitic grain boundary phases during annealing process. From current imaging tunneling spectroscopy and local current-voltage curves of scanning tunneling spectroscopic measurements, it is observed that the electrons are dominantly emitted from the grain boundaries. Consequently, the nanographitic phases presence in the grain boundaries formed conduction channels for efficient electron transport, ensuing in excellent electron field emission (EFE) properties for copper ion implanted/annealed UNCD films with low turn-on field of 4.80 V/μm and high EFE current density of 3.60 mA/cm{sup 2} at an applied field of 8.0 V/μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion-implanted thermal barrier

Ion implantation can be used to define a thermal dissipation path that allows for better thermal isolation between devices in close proximity on a microelectronics chip, thus providing a means for higher device density combined with better performance.

42 ENGINEERING↗

Mapping of fracture and ionic conductivity changes in ion implanted solid electrolytes: Insights from molecular dynamics

Ion implantation emerges as a promising technique to address the persistent challenge of lithium (Li) filament growth in solid-state electrolytes as it can induce compressive stresses inhibiting crack growth and deflect dendrites, de facto mitigating early electrolyte failure. In this study, we examine the potential paradox of ion implantation: while aiming to enhance electrolyte performance, the radiation damage associated with implantation might inadvertently compromise both the ionic conductivity and the intrinsic fracture toughness of the material, rendering the material unsuitable for battery applications. Specifically, we employed molecular dynamics simulations to examine the scope of the downsides of ion implantation, specifically: (i) reduced ionic conductivity (due to radiation-induced amorphization) and (ii) mechanical stability (due to radiation-induced embrittlement) in ion-implanted Li 7 La 3 Zr 2 O 12 (LLZO) solid-state electrolytes. We explore how radiation damage impacts LLZO’s crystalline structure, Li-ion diffusion, and fracture properties at various temperatures and radiation damage levels. The study aims to provide insights into the competing effects of ion implantation and suggest potential engineering strategies for developing more robust solid-state electrolytes with improved conductivity and dendrite resistance.

Conductivity↗