Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION EXTRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ion extraction from positively biased laser-ablation plasma

Ions were extracted through a grounded grid from a positively biased laser-ablation plasma and the behaviors were investigated. Since the plasma was positively biased against the grounded wall, we could extract the ions without insulated gap. We confirmed formation of a virtual anode when we increased the distance between the grid and the ion collector. Results also indicated that when the ion flux from the ablation plasma exceeded a critical value, the current was strongly suppressed to the space charge limited level due to the formation of virtual anode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion extraction capabilities of closely spaced grids

The ion extraction capabilities of accelerator systems with small screen hole diameters (less than 2.0 mm) are investigated at net-accelerating voltages of 100, 300, and 500 V. Results show that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 1.0 mm, but impingement-limited performance was found to be dependent on the grid separation distance, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained using small hole diameters and closely spaced grids indicate a new mode of grid operation where high current density operation can be achieved with a specified net acceleration voltage by operating the grids at a high rather than low net-to-total acceleration voltage. Beam current densities as high as 25 mA/sq cm were obtained using grids with 1.0 mm diameter holes operating at a net accelerating voltage of 500 V.

Rovang, D. C.↗

Influence of frequency tuning and double-frequency heating on ions extracted from an electron cyclotron resonance ion source

The electromagnetic field within the plasma chamber of an electron cyclotron resonance ion source (ECRIS) and the properties of the plasma waves affect the plasma properties and ion beam production. We have experimentally investigated the ''frequency tuning effect'' and ''double frequency heating'' on the CAPRICE ECRIS device. A traveling wave tube amplifier, two microwave sweep generators, and a dedicated experimental set-up were used to carry out experiments in the 12.5-16.5 GHz frequency range. During the frequency sweeps the evolution of the intensity and shape of the extracted argon beam were measured together with the microwave reflection coefficient. A range of different ion source parameter settings was used. Here we describe these experiments and the resultant improved understanding of these operational modes of the ECR ion source.

43 PARTICLE ACCELERATORS↗

Plasma Sputter-type Ion Source with Wire Electrodes for Low-energy Gallium Ion Extraction

Low-energy ions of gallium (Ga) and argon (Ar) were extracted from a plasma sputter-type ion source system that utilized a tungsten (W) wire extractor geometry. The 90% transparent W wire extractor configuration had shown that the system was capable of producing an ion beam with the energy as low as 10 eV in a dc filament discharge and 50 eV in a radio frequency (rf) excited system. In the present investigation, Ar plasma was sustained in an ion source chamber through an inductively coupled 13.56 MHz rf power source. Negatively biased liquid Ga target suspended on a W reservoir was sputtered and postionized prior to extraction. Mass spectral analyses revealed a strong dependence of the Ga{sup +} current on the induced target bias.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gallium ion extraction from a plasma sputter-type ion source

A broad mixed ion beam containing positive ions of gallium (Ga) was produced with a plasma sputter-type ion source. Liquid Ga was suspended on a tungsten reservoir to be sputtered and postionized in argon (Ar) plasma excited by a radio frequency (rf) power at 13.56 MHz. Optical emission spectra from the plasma near the Ga sputtering target had indicated that the release of Ga into plasma increased with increasing negative bias to the sputtering target. The ratio of Ga{sup +} current to Ar{sup +} current was measured to be about 1% with a quadrupole mass analyzer at 100 V extraction voltage for incident rf power as low as 30 W. Ions in the plasma were extracted through a pair of multiaperture electrodes. The homogeneity of Ga flux was examined by making a Ga deposition pattern on a glass substrate located behind the extractor electrodes.

43 PARTICLE ACCELERATORS↗

Metastable precipitation and ion–extractant transport in liquid–liquid separations of trivalent elements

The extractant-assisted transport of metal ions from aqueous to organic environments by liquid–liquid extraction has been widely used to separate and recover critical elements on an industrial scale. While current efforts focus on designing better extractants and optimizing process conditions, the mechanism that underlies ionic transport remains poorly understood. Here, we report a nonequilibrium process in the bulk aqueous phase that influences interfacial ion transport: the formation of metastable ion–extractant precipitates away from the liquid–liquid interface, separated from it by a depletion region without precipitates. Although the precipitate is soluble in the organic phase, the depletion region separates the two and ions are sequestered in a long-lived metastable state. Since precipitation removes extractants from the aqueous phase, even extractants that are sparingly soluble in water will continue to be withdrawn from the organic phase to feed the aqueous precipitation process. Solute concentrations in both phases and the aqueous pH influence the temporal evolution of the process and ionic partitioning between the precipitate and organic phase. Aqueous ion–extractant precipitation during liquid–liquid extraction provides a reaction path that can influence the extraction kinetics, which plays an important role in designing advanced processes to separate rare earths and other minerals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary results concerning the simulation of beam profiles from extracted ion current distributions for mini-STRIKE

The Radio Frequency (RF) negative hydrogen ion source prototype has been chosen for the ITER neutral beam injectors due to its optimal performances and easier maintenance demonstrated at Max-Planck-Institut für Plasmaphysik, Garching in hydrogen and deuterium. One of the key information to better understand the operating behavior of the RF ion sources is the extracted negative ion current density distribution. This distribution—influenced by several factors like source geometry, particle drifts inside the source, cesium distribution, and layout of cesium ovens—is not straightforward to be evaluated. The main outcome of the present contribution is the development of a minimization method to estimate the extracted current distribution using the footprint of the beam recorded with mini-STRIKE (Short-Time Retractable Instrumented Kalorimeter). To accomplish this, a series of four computational models have been set up, where the output of a model is the input of the following one. These models compute the optics of the ion beam, evaluate the distribution of the heat deposited on the mini-STRIKE diagnostic calorimeter, and finally give an estimate of the temperature distribution on the back of mini-STRIKE. Several iterations with different extracted current profiles are necessary to give an estimate of the profile most compatible with the experimental data. A first test of the application of the method to the BAvarian Test Machine for Negative ions beam is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selective and Chemical-Free Removal of Toxic Heavy Metal Cations from Water Using Shock Ion Extraction

Electrochemical methods are known to have attractive features and capabilities when used for ion separations and water purification. In this study, we developed a new process called shock ion extraction (shock IX) for selective and chemical-free removal of toxic heavy metals from water. Shock IX is a hybrid process that combines shock electrodialysis (shock ED) and ion exchange using an ion exchange resin wafer (IERW), and this method can be thought of functionally as an electrochemically assisted variation of traditional ion exchange. In particular, shock IX exhibits greater ion removal and selectivity for longer periods of time, compared to the use of ion exchange alone. Here, the use of an IERW in shock ED also increases multivalent ion selectivity, reduces energy consumption, and improves the hydrodynamics and scalability of the system.

54 ENVIRONMENTAL SCIENCES↗

13-kV Ion-Extraction System Being Developed for Inert Gas Ion Engines

A high-voltage ion optics design was chosen for an assumed outer planet or interstellar precursor mission that would require a long-life, high-power, high-specific-impulse krypton ion engine. Such an engine could support energetic space missions to the outer planets or beyond. Detailed performance and lifetime analyses and several inexpensive subscale grid tests were conducted at the NASA Glenn Research Center and at the Colorado State University under a NASA Glenn grant. A subscale grid set of the selected geometry shown was tested at voltages up to 13,000 V. This yielded a krypton ion beam current that would, when scaled to a full-size 50-cm diameter, produce an ion beam with a power of 30 kW at a specific impulse over 14,000 sec. The operational ion beam focusing limits, as a function of ion current per hole, were found to impose requirements of high uniformity on the discharge chamber plasma density. A full-size set of two-grid, 50-cm-diameter titanium ion optics has been fabricated and awaits testing.

Rawlin, Vincent K.↗

Investigation of metal ion extraction and aggregate formation combining acidic and neutral organophosphorous reagents

In the present study, we investigate how varying mixtures of tri-n-butyl phosphate (TBP) and dibutyl phosphate (HDBP) results in enhanced extraction of lanthanum(III), La{sup 3+}, and dysprosium(III), Dy{sup 3+}. Water and metal ion extraction were carefully monitored as a function of TBP:HDBP mole ratio.In addition to these techniques, EXAFS was used to determine the coordination environment of the metal ion in this system. To produce the necessary signal, a concentration of 1.25*10{sup -3} M La{sup 3+} and Dy{sup 3+} was used. Although previous studies of synergistic extraction of metal cations using combinations of neutral and acidic reagents explain the enhanced extraction by increased dehydration of the metal ion and the formation of mixed extractant complexes, our evidence for the increased water extraction coupled with the aggregate formation suggests a reverse micellar aspect to synergism in the system containing TBP and HDBP. It is quite possible that both of these phenomena contribute to our system behavior. The EXAFS data shows that, based on coordination numbers alone, several possible structures may exist. From this study, we cannot provide a definitive answer as to the nature of extraction in this system or the exact complex formed during extraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance limits of ion extraction systems with non-circular apertures

A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of emittance of multiply charged ions extracted from high temperature superconducting electron cyclotron resonance ion source, PKDELIS

For the high current injector project at Inter University Accelerator Centre, a high temperature superconducting electron cyclotron resonance (ECR) ion source, PKDELIS, would provide the high charge state ions. The emittance of the ECR ion source is an important parameter to design further beam transport system and to match the acceptances of the downstream radio frequency quadrupole and drift tube linac accelerators of the high current injector. The emittance of the analyzed beam of PKDELIS ECR source has been measured utilizing the three beam size technique. A slit and two beam profile monitors positioned at fixed distances from each other were used to measure the beam size. The digitized beam profiles have been analyzed to determine the emittance of various multiply charged ions. The variation of emittance with gas mixing, ultrahigh frequency power, and extraction energy are discussed in this presentation.

43 PARTICLE ACCELERATORS↗

Membrane-Extraction Ion Mobility Spectrometry for In-Situ Detection of Chlorinated Hydrocarbons in Water

Membrane-extraction ion mobility spectrometry (ME-IMS) has been developed for in-situ sampling and analysis of trace chlorinated hydrocarbons in water in a single procedure. The sampling is configured so that aqueous contaminants permeate through a spiral hollow polydimethylsiloxane (PDMS) membrane and are carried away by a vapor flow through the membrane tube. The extracted analyte flows into an atmospheric pressure chemical ionization (APCI) chamber and is analyzed in a home-made IMS analyzer. PDMS membrane is found to effectively extract chlorinated hydrocarbon solvents from liquid phase to vapor. The specialized IMS analyzer has been found to have resolutions of R=33 and 41, respectively, for negative- and positive-modes and is capable of detecting aqueous tetrachloroethylene (PCE) and trichloroethylene (TCE) as low as 80 g/L and 74 g/L in negative ion mode, respectively. The time-dependent characteristics of sampling and detection of TCE are both experimentally and theoretically studied for various concentrations, membrane lengths, and flow rates. These characteristics demonstrate that membrane-extraction IMS is feasible for the continuous monitoring of chlorinated hydrocarbons in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simple model analysis on the negative-ion extraction from a plasma

Extraction of negative hydrogen ions from a plasma is analyzed with a view to the description of the extraction region of the negative hydrogen ion-beam sources developed for additional heating of fusion plasmas. The numerical procedure introduced in the study is a modification of the indirect Poisson-Vlasov method. It uses a condition for the plasma meniscus and employs analogy with the particle-in-cell model simulation. The analysis of the results shows that the charged particle velocity distribution at the entrance of the extraction region influences the properties of the extracted beams and its effect should be considered when conditions for well converged beams are looked for through variation in the plasma density and in the potentials of the electrodes of the extraction system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma characteristics of single- and dual-electrode ion source systems utilized in low-energy ion extraction

Discharge characteristics in the upstream as well as in the downstream regions of a 50-eV positive ion beam were measured along the beam axis. Single- and dual-electrode configurations made of 0.1-mm diameter tungsten wires were tested. By varying the upstream discharge parameters, the shape of the sheath edge around the extractors, which can either be “planar” or “cylindrical,” can be controlled. The sheath eventually affected the simultaneous extraction of ions and neutralizing electrons. The dual-electrode configuration at the lower discharge current, revealed a homogeneous discharge downstream. At this condition, the edge of the sheath can be inferred to be “planar” which allowed the uniform extraction and propagation of low-energy ions at longer distances. The dual-electrode configuration was capable of transmitting low-energy ions up to 70 mm downstream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion extraction system optimization

The extraction of a beam from ion sources is dominated by the strong space charge of the beam, due to the initial low speed of the particles. Several mathematical and computational issues are discussed, with reference to a diode design based on thin anode lens effect, yielding a parallel beam at its exit, which is the first block of many high current electrostatic accelerators. Perturbation to uniform current density are analyzed. Effect of a thick anode lens is also treated.

43 PARTICLE ACCELERATORS↗

The role of space charge compensation for ion beam extraction and ion beam transport (invited)

Depending on the specific type of ion source, the ion beam is extracted either from an electrode surface or from a plasma. There is always an interface between the (almost) space charge compensated ion source plasma, and the extraction region in which the full space charge is influencing the ion beam itself. After extraction, the ion beam is to be transported towards an accelerating structure in most cases. For lower intensities, this transport can be done without space charge compensation. However, if space charge is not negligible, the positive charge of the ion beam will attract electrons, which will compensate the space charge, at least partially. The final degree of Space Charge Compensation (SCC) will depend on different properties, like the ratio of generation rate of secondary particles and their loss rate, or the fact whether the ion beam is pulsed or continuous. In sections of the beam line, where the ion beam is drifting, a pure electrostatic plasma will develop, whereas in magnetic elements, these space charge compensating electrons become magnetized. The transport section will provide a series of different plasma conditions with different properties. Different measurement tools to investigate the degree of space charge compensation will be described, as well as computational methods for the simulation of ion beams with partial space charge compensation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Metal ion extraction from brines

A material includes a porous particle that includes a metal ion imprinted polymer. The metal ion imprinted polymer is formed from a hydrophilic co-monomer, a metal containing polymerizable compound, and a cross-linking agent. The metal containing polymerizable compound includes at least one metal chelating ligand. The metal ion imprinted polymer includes a plurality of metal ion selective binding sites. A method includes flowing brine containing a metal ion through a reactor that includes the material. The method further includes discharging the brine from the reactor, contacting the porous particles with water, and pressurizing the reactor with carbon dioxide. The carbon dioxide reacts with the adsorbed metal ions to form a metal carbonate solution. The method further includes depressurizing the reactor to precipitate metal carbonate from the metal carbonate solution and discharging the metal carbonate solution from the reactor.

36 MATERIALS SCIENCE↗