Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Demonstration of closed shell breeding of cesium ions with an electron beam ion source

An electron beam ion source serves as a charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) at the Argonne Tandem Linac Accelerator System (ATLAS). The source accepts radioactive beams of 1+ or 2+ ions and raises their charge state for post-acceleration by ATLAS. The efficiency of this process impacts the length of each experiment and, hence, the type and number of experiments that can be run in each program cycle. Recent efforts to improve the charge breeding efficiency for the 80 < A < 160 species typical of CARIBU have focused on utilizing the closed shell breeding technique. Here, with this technique, the electron beam energy is manipulated to take advantage of the large gap in ionization energies at shell closures and selectively populate a single charge state. Charge breeding studies with stable cesium ions have demonstrated an absolute efficiency of 72% for Cs 27+ and a total efficiency of 93%. The Cs 27+ efficiency result represents a factor of 3 improvement over the previous best charge breeding result of 23% for Cs 27+ .

Vondrasek, R. [Argonne National Laboratory (ANL), ↗

Ion Beam Propulsion Study

The Ion Beam Propulsion Study was a joint high-level study between the Applied Physics Laboratory operated by NASA and ASRC Aerospace at Kennedy Space Center, Florida, and Berkeley Scientific, Berkeley, California. The results were promising and suggested that work should continue if future funding becomes available. The application of ion thrusters for spacecraft propulsion is limited to quite modest ion sources with similarly modest ion beam parameters because of the mass penalty associated with the ion source and its power supply system. Also, the ion source technology has not been able to provide very high-power ion beams. Small ion beam propulsion systems were used with considerable success. Ion propulsion systems brought into practice use an onboard ion source to form an energetic ion beam, typically Xe+ ions, as the propellant. Such systems were used for steering and correction of telecommunication satellites and as the main thruster for the Deep Space 1 demonstration mission. In recent years, "giant" ion sources were developed for the controlled-fusion research effort worldwide, with beam parameters many orders of magnitude greater than the tiny ones of conventional space thruster application. The advent of such huge ion beam sources and the need for advanced propulsion systems for exploration of the solar system suggest a fresh look at ion beam propulsion, now with the giant fusion sources in mind.

Source record↗

Realizing the scientific program with polarized ion beams at the future BNL Electron Ion Collider

Polarized ion beams at the Electron Ion Collider (EIC) are essential to address some of the most important open questions at the twenty-first century frontiers of understanding of the fundamental structure of matter. Here, in this work, we summarize the science case and identify polarized 2 H, 3 He, 6 Li, and 7 Li ion beams as critical technology that will enable experiments which address the most important science. Furthermore, we discuss the required ion polarimetry and spin manipulation at the EIC. The current EIC accelerator design is presented. We identify a significant research and development effort across national and international laboratories and universities that is required over about a decade to realize the polarized ion beams and estimate (based on previous experience) that it will require about 20 full-time equivalent (FTE) over 10 years (or a total of about 200 FTE-years) of personnel, including graduate students, postdoctoral researchers, technicians, and engineers. Attracting, educating, and training a new generation of physicists in experimental spin techniques will be essential for the successful realization. Artificial intelligence and machine learning are seen as having significant potential for both acceleration of research and development and amplification of discovery in the optimal realization of this unique quantum technology on a cutting-edge collider. The research and development effort is synergistic with research in atomic physics and fusion energy science.

43 PARTICLE ACCELERATORS↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ARCS 3 ionospheric artificial argon ion beam injections - Waves near the heavy ion gyrofrequencies

Low-frequency electric field data below the proton gyrofrequency are presented for the duration of the argon ion beam experiment conducted as part of the Argon Release for Controlled Studies (ARCS) program. An argon ion beam was injected from the subpayload antiparallel or perpendicular to the magnetic field at altitudes from 250 to 405 km. During the injections, the wave spectra were broadband near the subpayload and narrow-band near heavy ion gyrofrequencies at perpendicular separation distances between 42 and 254 m. It is suggested that the narrow-band waves are associated with both the perpendicular argon ion beam and an unexpected flux of low-energy ions which peaked in energy near 15 eV and pitch angle near 90 deg with respect to the magnetic field.

Erlandson, R. E.↗

Ion beam sputtering of fluoropolymers

Ion beam sputter processing rates as well as pertinent characteristics of etched targets and films are described. An argon ion beam source was used to sputter etch and deposit the fluoropolymers PTFE, FEP, and CTFE. Ion beam energy, current density, and target temperature were varied to examine effects on etch and deposition rates. The ion etched fluoropolymers yield cone or spire-like surface structures which vary depending upon the type of polymer, ion beam power density, etch time, and target temperature. Sputter target and film characteristics documented by spectral transmittance measurements, X-ray diffraction, ESCA, and SEM photomicrographs are included.

Sovey, J. S.↗

Response of thermal and fast-ion transport to beam ion population, rotation and T e / T i in the DIII-D steady state hybrid scenario

The thermal and fast-ion transport properties of DIII-D steady-state hybrid discharges with normalized beta β N ≳ 3 are studied at low injected torque and an increased electron to ion temperature ratio T e / T i . Linear stability analysis performed with the TGLF turbulent code indicates that a high-k mode is usually dominant at smaller radii, whereas a low-k mode is usually dominant at larger radii in these plasmas. A reduction in the net injected torque from 8.6 to 4.3 N-m leads to reduced E × B shear and hence, an enhanced turbulence that was observed on the Doppler backscattering diagnostic and was also computed with TGLF. As T e / T i in the core was increased from 0.57 to 0.66 by adding electron cyclotron current drive (ECCD) to these plasmas, higher levels of transport are observed with increased high-k modes indicated by TGLF. The fast-ion transport level varied over an order of magnitude in these discharges depending on whether Alfvén eigenmodes, fishbones, or no instabilities were observed. Hybrid plasmas with fishbones have decreased fast-ion transport, compared to plasmas with Alfvén eigenmodes, since they are resonant with a smaller portion of phase space and their resonance is farther from the wall. This reduction in fast-ion transport with ECCD mitigates the increase in turbulent transport, resulting in higher performance than expected during strong electron heating. Similarly, the lowest fast-ion transport was observed in the low torque plasma, which also led to better than expected performance at this torque value. Finally, the thermal and fast-ion transport changes observed as the torque/rotation and T e / T i are varied indicate possible methods for transferring this scenario to a reactor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Ion energy distribution in an electron beam ion trap inferred from simulations of the trapped ion cloud

For this work, we have inferred the energy distribution of trapped ions in an electron beam ion trap (EBIT) from simulations of the spatial distribution of Fe 13+ ions and a comparison with measured visible light images of the ion cloud. We simulated the cloud of Fe 13+ ions by computing ion trajectories in the EBIT for different ion energy distributions used to initialize the trajectories. We then performed a least-squares fit to infer the ion energy distribution that best reproduced the measured ion cloud. These best-fit distributions were typically non-Maxwellian. For electron beam energies of 395–475 eV and electron beam currents of 1–9 mA, we find that the average ion energy is in the range of 10–300 eV. We also find that the average ion energy increases with increasing beam current approximately as $\langle$E$\rangle$ ≈ 25 I e eV, where I e is the electron beam current in mA. We have also compared our results to Maxwell-Boltzmann-distribution ion clouds. We find that our best-fit non-thermal distributions have an $\langle$E$\rangle$ that is less than half that of the T from the best-fit Maxwell-Boltzmann distributions ($\langle$E$\rangle$/q)/T=0.41 ± 0.05.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spacecraft charging during ion beam emissions in sunlight

During ion beam emissions from the SCATHA satellite, the potential of the negatively charged satellite body shows a sinusoidal oscillation frequency of once-per-spin of the satellite. The minimum occurs when the ion beam is sunward. The processes that may be responsible for the voltage modulation are considered. Neutralization of ion beam space charge by photoelectrons is examined. The photoelectrons are accelerated by the negative potential of the satellite. Effects of electron impact ionization, excitation of metastable states, and photoionization of xenon neutral atoms in the ion beam are studied in detail. Critical ionization velocity interaction is unlikely under the condition considered.

Lai, S. T.↗

Exploration of Defect Dynamics and Color Center Qubit Synthesis with Pulsed Ion Beams

Short-pulse ion beams have been developed in recent years and now enable applications in materials science. A tunable flux of selected ions delivered in pulses of a few nanoseconds can affect the balance of defect formation and dynamic annealing in materials. We report results from color center formation in silicon with pulses of 900 keV protons. G-centers in silicon are near-infrared photon emitters with emerging applications as single-photon sources and for spin-photon qubit integration. G-centers consist of a pair of substitutional carbon atoms and one silicon interstitial atom and are often formed by carbon ion implantation and thermal annealing. Here, we report on G-center formation with proton pulses in silicon samples that already contained carbon, without carbon ion implantation or thermal annealing. The number of G-centers formed per proton increased when we increased the pulse intensity from 6.9 × 10 9 to 7.9 × 10 10 protons/cm 2 /pulse, demonstrating a flux effect on G-center formation efficiency. We observe a G-center ensemble linewidth of 0.1 nm (full width half maximum), narrower than previously reported. Pulsed ion beams can extend the parameter range available for fundamental studies of radiation-induced defects and the formation of color centers for spin-photon qubit applications.

43 PARTICLE ACCELERATORS↗

Heavy ion beam probe measurements of radial potential profiles in the Modified Penning discharge

The reported measurements were conducted with the primary beam of an ion beam probe in a plasma discharge in which the space potential represents a large fraction of the primary beam energy. A Lewis ion beam probe similar to the device employed by Jobes et al. (1969) was used in the investigation. The apparatus used in the experiments is discussed along with the experimental procedure. The approximate radial potential profile was obtained by observing the effect of the plasma on the trajectory of the primary beam.

Kambic, G. X.↗

Ion beam plume and efflux measurements of an 8-cm mercury ion thruster

Measurements of the ion beam plume and efflux constituents of an 8-cm mercury ion thruster have been carried out in the TRW 5 x 10 foot testing chamber. Charged components (ion beam plume) were measured with an array of movable position Faraday cups and retarding potential analyzers yielding both current density and particle energy determinations. Neutral components (ion beam efflux) were determined with a movable position ionization gauge. Measurements of the ion beam plume were performed for a thruster both with and without a sputter shield. Analysis of data in terms of normalized effluxes has been carried out and has been applied to an example calculation of efflux compatibility with a communications spacecraft.

Komatsu, G. K.↗

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗

Depth-dose relations for heavy ion beams

Radiation transport of heavy ions in matter is of interest to radiological protection in space and high-altitude aircraft. In addition, heavy ion beams are expected to be of advantage in radiotherapy since their characteristic Bragg curve allows a relative reduction of the dose in reaching a tumor site and the near elimination of exposure beyond the tumor region as the beam exits the body. Furthermore, the radioresistance of tumorous cells due to their hypoxic state may be reduced or eliminated by the high specific ionization of heavy ion beams. The depth-dose distribution of heavy ion beams consists of energy deposited by the attenuated primary beam with its characteristic Bragg curve and a relatively unstructured background due to secondary radiations produced in nuclear reactions. As the ion mass increases, the secondary contribution becomes more structured and may add significantly to the Bragg peak of the primary ions. The result for heavy ions (z greater than 20) is a greatly broadened Bragg peak region, especially in comparison to straggling effects, which may prove to be of importance in radiotherapy and biomedical research.

Wilson, J. W.↗

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic pros-thesis fixtion, and dental implants.

Banks, B. A.↗