Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION BEAM THERAPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Single-Event Effect Testing of the Vishay Si7414DN n-Type TrenchFET(Registered Trademark) Power MOSFET

This study was being undertaken to determine the single event effect susceptibility of the commercial Vishay 60-V TrenchFET power MOSFET. Heavy-ion testing was conducted at the Texas AM University Cyclotron Single Event Effects Test Facility (TAMU) and the Lawrence Berkeley National Laboratory BASE Cyclotron Facility (LBNL). In addition, initial 200-MeV proton testing was conducted at Massachusetts General Hospital (MGH) Francis H. Burr Proton Beam Therapy Center. Testing was performed to evaluate this device for single-event effects from lower-LET, lighter ions relevant to higher risk tolerant space missions.

proton testing↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

A Green's function method for heavy ion beam transport

The use of Green's function has played a fundamental role in transport calculations for high-charge high-energy (HZE) ions. Two recent developments have greatly advanced the practical aspects of implementation of these methods. The first was the formulation of a closed-form solution as a multiple fragmentation perturbation series. The second was the effective summation of the closed-form solution through nonperturbative techniques. The nonperturbative methods have been recently extended to an inhomogeneous, two-layer transport media to simulate the lead scattering foil present in the Lawrence Berkeley Laboratories (LBL) biomedical beam line used for cancer therapy. Such inhomogeneous codes are necessary for astronaut shielding in space. The transport codes utilize the Langley Research Center atomic and nuclear database. Transport code and database evaluation are performed by comparison with experiments performed at the LBL Bevalac facility using 670 A MeV 20Ne and 600 A MeV 56Fe ion beams. The comparison with a time-of-flight and delta E detector measurement for the 20Ne beam and the plastic nuclear track detectors for 56Fe show agreement up to 35%-40% in water and aluminium targets, respectively.

NASA Discipline Radiation Health↗

Helium-ion-induced human cataractogenesis

Retrospective and ongoing analyses of clinical records from 347 primary intraocular melanoman patients treated with helium ions at Lawrence Berkeley Laboratory (LBL) will allow examination of the exposure-response data for human cataract; which is a complication of the therapy from incidental exposure of the lens. Direct particle beam traversal of at least a portion of the lens usually is unavoidable in treatment of posterior intraocular tumors. The precise treatment planned for each patient permits quantitative assessment of the lenticular dose and its radiation quality. We are reporting our preliminary results on the development of helium-ion-induced lens opacifications and cataracts in 54 of these patients who had 10% or less of their lens in the treatment field. We believe these studies will be relevant to estimating the human risk for cataract in space flight.

Blakely, E. A.↗

Design and Principles of Linear Accelerators and Colliders." in Particle Physics Reference Library, pp. 295-336. Springer, Cham, 2020.

Linear accelerators (linacs) use alternating radiofrequency (RF) electromagnetic fields to accelerate charged particles in a straight line. Linacs were invented about 95 years ago and have seen many significant technical innovations since. A wide range of particle beams have been accelerated with linacs including beams of electrons, positrons, protons, antiprotons, and heavy ions. Linac parameter possibilities include pulsed versus continuous wave, low and high beam powers, low and high repetition rates, low transverse emittance beams, short bunches with small energy spreads, and accelerated multiple bunches in a single pulse. The number of linacs around the world has grown tremendously with thousands of linacs in present use, many for medical therapy, in industry, and for research and development in a broad spectrum of scientific fields. Researchers have developed accelerators for scientific tools in their own right, being awarded several Nobel prizes. Moreover, linacs and particle accelerators in general have enabled many discovery level science experiments in related fields, resulting in many Nobel prizes as well.

Seeman, John↗

Overview of the Graphical User Interface for the GERMcode (GCR Event-Based Risk Model)

The descriptions of biophysical events from heavy ions are of interest in radiobiology, cancer therapy, and space exploration. The biophysical description of the passage of heavy ions in tissue and shielding materials is best described by a stochastic approach that includes both ion track structure and nuclear interactions. A new computer model called the GCR Event-based Risk Model (GERM) code was developed for the description of biophysical events from heavy ion beams at the NASA Space Radiation Laboratory (NSRL). The GERMcode calculates basic physical and biophysical quantities of high-energy protons and heavy ions that have been studied at NSRL for the purpose of simulating space radiobiological effects. For mono-energetic beams, the code evaluates the linear-energy transfer (LET), range (R), and absorption in tissue equivalent material for a given Charge (Z), Mass Number (A) and kinetic energy (E) of an ion. In addition, a set of biophysical properties are evaluated such as the Poisson distribution of ion or delta-ray hits for a specified cellular area, cell survival curves, and mutation and tumor probabilities. The GERMcode also calculates the radiation transport of the beam line for either a fixed number of user-specified depths or at multiple positions along the Bragg curve of the particle. The contributions from primary ion and nuclear secondaries are evaluated. The GERMcode accounts for the major nuclear interaction processes of importance for describing heavy ion beams, including nuclear fragmentation, elastic scattering, and knockout-cascade processes by using the quantum multiple scattering fragmentation (QMSFRG) model. The QMSFRG model has been shown to be in excellent agreement with available experimental data for nuclear fragmentation cross sections, and has been used by the GERMcode for application to thick target experiments. The GERMcode provides scientists participating in NSRL experiments with the data needed for the interpretation of their experiments, including the ability to model the beam line, the shielding of samples and sample holders, and the estimates of basic physical and biological outputs of the designed experiments. We present an overview of the GERMcode GUI, as well as providing training applications.

Kim, Myung-Hee Y.↗

Overview of the Graphical User Interface for the GERM Code (GCR Event-Based Risk Model

The descriptions of biophysical events from heavy ions are of interest in radiobiology, cancer therapy, and space exploration. The biophysical description of the passage of heavy ions in tissue and shielding materials is best described by a stochastic approach that includes both ion track structure and nuclear interactions. A new computer model called the GCR Event-based Risk Model (GERM) code was developed for the description of biophysical events from heavy ion beams at the NASA Space Radiation Laboratory (NSRL). The GERM code calculates basic physical and biophysical quantities of high-energy protons and heavy ions that have been studied at NSRL for the purpose of simulating space radiobiological effects. For mono-energetic beams, the code evaluates the linear-energy transfer (LET), range (R), and absorption in tissue equivalent material for a given Charge (Z), Mass Number (A) and kinetic energy (E) of an ion. In addition, a set of biophysical properties are evaluated such as the Poisson distribution of ion or delta-ray hits for a specified cellular area, cell survival curves, and mutation and tumor probabilities. The GERM code also calculates the radiation transport of the beam line for either a fixed number of user-specified depths or at multiple positions along the Bragg curve of the particle. The contributions from primary ion and nuclear secondaries are evaluated. The GERM code accounts for the major nuclear interaction processes of importance for describing heavy ion beams, including nuclear fragmentation, elastic scattering, and knockout-cascade processes by using the quantum multiple scattering fragmentation (QMSFRG) model. The QMSFRG model has been shown to be in excellent agreement with available experimental data for nuclear fragmentation cross sections, and has been used by the GERM code for application to thick target experiments. The GERM code provides scientists participating in NSRL experiments with the data needed for the interpretation of their experiments, including the ability to model the beam line, the shielding of samples and sample holders, and the estimates of basic physical and biological outputs of the designed experiments. We present an overview of the GERM code GUI, as well as providing training applications.

Kim, Myung-Hee↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production and Purification of Terbium-155 Using Natural Gadolinium Targets

Terbium-155 (t 1/2 = 5.32 days) is one of four medically relevant radioisotopes of terbium. It is of interest to the field as a suitable diagnostic counterpart for therapeutic radiolanthanides, as its decay scheme includes γ-rays that are suitable for single photon emission computed tomography (SPECT) imaging. Additionally, 155 Tb has an Auger electron (AE) yield that is viable for AE therapy. There are several direct and indirect production routes that can produce 155 Tb. Two possible direct routes include proton irradiation on gadolinium targets via 155 Gd(p,n) 155 Tb and 156 Gd(p,2n) 155 Tb. The 155 Gd(p,n) 155 Tb reaction is accessible at incident proton beam energies of ∼10 MeV, whereas the 156 Gd(p,2n) 155 Tb nuclear reaction requires ∼18 MeV. This study aims to investigate the production of 155 Tb from natGd through the nat Gd(p,x) nuclear reaction, wherein both (p,n) and (p,2n) reactions were leveraged, and the purification using a three-column ion chromatography method. Using this system, recoveries of radioterbium of up to 97% were achieved in addition to high recoveries of the Gd target material, illustrating the suitability of this technique for enriched targets.

36 MATERIALS SCIENCE↗

Update On the Status of the FLUKA Monte Carlo Transport Code*

The FLUKA Monte Carlo transport code is a well-known simulation tool in High Energy Physics. FLUKA is a dynamic tool in the sense that it is being continually updated and improved by the authors. We review the progress achieved since the last CHEP Conference on the physics models, some technical improvements to the code and some recent applications. From the point of view of the physics, improvements have been made with the extension of PEANUT to higher energies for p, n, pi, pbar/nbar and for nbars down to the lowest energies, the addition of the online capability to evolve radioactive products and get subsequent dose rates, upgrading of the treatment of EM interactions with the elimination of the need to separately prepare preprocessed files. A new coherent photon scattering model, an updated treatment of the photo-electric effect, an improved pair production model, new photon cross sections from the LLNL Cullen database have been implemented. In the field of nucleus-- nucleus interactions the electromagnetic dissociation of heavy ions has been added along with the extension of the interaction models for some nuclide pairs to energies below 100 MeV/A using the BME approach, as well as the development of an improved QMD model for intermediate energies. Both DPMJET 2.53 and 3 remain available along with rQMD 2.4 for heavy ion interactions above 100 MeV/A. Technical improvements include the ability to use parentheses in setting up the combinatorial geometry, the introduction of pre-processor directives in the input stream. a new random number generator with full 64 bit randomness, new routines for mathematical special functions (adapted from SLATEC). Finally, work is progressing on the deployment of a user-friendly GUI input interface as well as a CAD-like geometry creation and visualization tool. On the application front, FLUKA has been used to extensively evaluate the potential space radiation effects on astronauts for future deep space missions, the activation dose for beam target areas, dose calculations for radiation therapy as well as being adapted for use in the simulation of events in the ALICE detector at the LHC.

Ferrari, A.↗

Direct evidence for low-energy electron emission following O LVV Auger transitions at oxide surfaces

Abstract Oxygen, the third most abundant element in the universe, plays a key role in the chemistry of condensed matter and biological systems. Here, we report evidence for a hitherto unexplored Auger transition in oxides, where a valence band electron fills a vacancy in the 2s state of oxygen, transferring sufficient energy to allow electron emission. We used a beam of positrons with kinetic energies of $$\sim 1$$ ∼ 1 eV to create O 2s holes via matter-antimatter annihilation. This made possible the elimination of the large secondary electron background that has precluded definitive measurements of the low-energy electrons emitted through this process. Our experiments indicate that low-energy electron emission following the Auger decay of O 2s holes from adsorbed oxygen and oxide surfaces are very efficient. Specifically, our results indicate that the low energy electron emission following the Auger decay of O 2s hole is nearly as efficient as electron emission following the relaxation of O 1s holes in $$\hbox {TiO}_2$$ TiO 2 . This has important implications for the understanding of Auger-stimulated ion desorption, Coulombic decay, photodynamic cancer therapies, and may yield important insights into the radiation-induced reactive sites for corrosion and catalysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Angular distribution of neutron production by proton and carbon-ion therapeutic beams

Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.

60 APPLIED LIFE SCIENCES↗