Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optical layout and mechanical structure of polarimeter-interferometer system for Experimental Advanced Superconducting Tokamak

A Far-InfaRed (FIR) three-wave POlarimeter-INTerferometer (POINT) system for measurement current density profile and electron density profile is under development for the EAST tokamak. The FIR beams are transmitted from the laser room to the optical tower adjacent to EAST via ∼20 m overmoded dielectric waveguide and then divided into 5 horizontal chords. The optical arrangement was designed using ZEMAX, which provides information on the beam spot size and energy distribution throughout the optical system. ZEMAX calculations used to optimize the optical layout design are combined with the mechanical design from CATIA, providing a 3D visualization of the entire POINT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Faraday-effect polarimeter-interferometer system for current density measurement on EAST

A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide real-time Faraday rotation angle and density phase shift output, have been developed for use on the POINT system. Initial calibration indicates the electron line-integrated density resolution is less than 5 × 10{sup 16} m{sup −2} (∼2°), and the Faraday rotation angle rms phase noise is <0.1°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A phase contrast imaging–interferometer system for detection of multiscale electron density fluctuations on DIII-D

Heterodyne interferometry and phase contrast imaging (PCI) are robust, mature techniques for measuring low-k and high-k electron density fluctuations, respectively. This work describes the first-ever implementation of a combined PCI–interferometer. The combined system uses a single 10.6 μm probe beam, two interference schemes, and two detectors to measure electron density fluctuations at large spatiotemporal bandwidth (10 kHz <f < 5 MHz and 0 cm{sup -1} ≤k ≤ 20 cm{sup -1}), allowing simultaneous measurement of ion- and electron-scale instabilities. Further, correlating our interferometer’s measurements with those from DIII-D’s pre-existing, toroidally separated interferometer allows core-localized, low-n MHD studies that may otherwise be inaccessible via external magnetic measurements. The combined diagnostic’s small port requirements and minimal access restrictions make it well-suited to the harsh neutron environments and limited port space expected in next-step devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Wide-Field Spatio-Spectral Interferometer: System Overview, Data Synthesis and Analysis

The Wide-field Imaging Interferometry Testbed (WIIT) is a double Fourier (DF) interferometer operating at optical wavelengths, and provides data that are highly representative of those from a space-based far-infrared interferometer like SPIRIT. We have used the testbed to observe both geometrically simple and astronomically representative test scenes. Here we present an overview of the astronomical importance of high angular resolution at the far infrared, followed by the description of the optical set-up of WIIT, including the source simulator CHIP (Calibrated Hyperspectral Image Projector). We describe our synthesis algorithms used in the reconstruction of the input test scenes via a simulation of the most recent measurements. The updated algorithms, which include instruments artifacts that allow the synthesis of DF experimental data, are presented and the most recent results analyzed.

Juanola-Parramon, Roser↗

A combined phase contrast imaging and heterodyne interferometer system for multiscale fluctuation measurements (invited)

In this work, a novel combined diagnostic capable of measuring multiscale density fluctuations that extend from magnetohydrodynamic (MHD) to the lower range of electron temperature gradient turbulence has been designed, installed, and operated at DIII-D. The combined diagnostic was constructed by adding a heterodyne interferometer to the pre-existing phase contrast imaging (PCI) system, both of which measure line-integrated electron density fluctuations. The port-space footprint is minimized via use of a single 10.6 μm probe beam. With temporal bandwidths in excess of 1 MHz, the PCI measures high-k (1.5 cm -1 < |k R | ≤ 25 cm -1 ) fluctuations with sensitivity 3×10 13 m -2 /$\sqrt{kHz}$, while the interferometer simultaneously measures low-k (|k R | < 5 cm -1 ) fluctuations with sensitivity 3×10 14 m -2 /$\sqrt{kHz}$. The intentional mid-k overlap has been empirically verified with sound-wave calibrations and allows quantitative investigation of multiscale effects that are predicted to be significant in the reactor-relevant T e ~ T i regime. Lastly, via correlation with the primary DIII-D interferometer, the toroidal mode numbers of core-localized MHD can be measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The StarLight formation-flying interferometer system architecture

The StarLight Project, scheduled for a 6-month mission in 2006, will demonstrate the new technologies of spaceborne long-baseline optical interferometry and precision formation flying necessary for the Terrestrial Planet Finder and other future astropohysics missions.

StarLight Project interferometers↗

Description of the ISEE satellite-to-satellite kilometric wavelength interferometer system

The International Sun-Earth Explorer (ISEE) spacecraft 1 and 2 carry receivers for detecting electromagnetic waves with kilometric wavelengths. For selected receiver frequencies from 30 kHz to 2 MHz, a 10-kHz bandwidth channel is single-sideband mixed down to baseband. These analog data and a reference frequency, which is a submultiple of the local oscillator frequency, are transmitted to ground stations and tape recorded along with the precise time and frequency information. Cross correlation of these tape recorded signals constitutes a satellite-to-satellite interferometer with a fringe spacing of 0.4 to 41 arcmin (at a range of 10,000 to 100 km spacing between spacecraft for 250 kHz in frequency) and with a time-delay resolution of 32 microsec for a 10-kHz bandwidth, which gives an angular resolution of 3 min to 6 deg of arc. For kilometric radiation at earth, sources in the size range of 25 to 2500 km can be identified (from 20 earth radii) and located in relative position ranging from 0.02 to 2 earth radii, depending on spacecraft spacing. Reception and analysis of solar and Jovian bursts may also be possible.

Shawhan, S. D.↗

A holographic interferometer system for measuring density profiles in high-velocity flows

This paper describes a holographic interferometric technique for obtaining density measurements across a test gas that is traveling at a velocity of over 5500 m/sec in an expansion tube facility. Interferometric data describing the flow in the test section are obtained using a long coherence length CW argon laser in a holographic system and a rotating drum camera recorder. The object beam, which passes through the test section, intersects the reference beam at a small angle to form an interference pattern of about 170 lines/mm, and is recorded as a hologram. Before a test, this hologram is placed in its original position and rotated slightly so that an interference pattern is generated by the intersection of the reconstructed and real-time object beams.

Burner, A. W.↗

Precision geodesy using the Mark-III very-long-baseline interferometer system

Very-long-baseline interferometry (VLBI) has been used to make precise measurements of the vector separation between widely separated antennas. The system for acquiring and processing VLBI data known as Mark-III is described. Tests of the system show it to have millimeter-level accuracy on short baselines; measurements of baselines longer than a few hundred kilometers suggest that accuracy is limited by the uncertainty in the calibration of tropospheric path delay to the level of a few centimeters. VLBI experiments conducted between 1976 and 1983 have demonstrated the stability of the North American plate by showing that there is no change in the distance between eastern California and Massachusetts at the level of a few millimeters per year or greater. Experiments made from 1980 to 1984 indicate that the distance from Massachusetts to Sweden is increasing by 1.7 + or - 1 cm/year where the quoted standard deviation includes the estimated effects of systematic errors.

Clark, T. A.↗

A Holographic Interferometer System for Measuring Density Profiles in High-Velocity Flows

This paper describes a holographic interferometric technique for obtaining density measurements across a test gas that is traveling at a velocity of over 5500 meters per second in an expansion tube facility. Interferometric data describing the flow in the test section are obtained using a long coherence length cw argon laser in a holographic system and a rotating drum camera recorder. The object beam, which passes through the test section, intersects the reference beam at a small angle (5 degrees) to form an interference pattern of about 170 lines per millimeter, and is recorded as a hologram. Before a test, this hologram is placed in its original position and rotated slightly so that an interference pattern is generated by the intersection of the reconstructed and real-time object beams. This interference pattern is adjusted to a series of bright, horizontal fringes having a spatial frequency of about 5 fringes per centimeter. During the few milliseconds it takes the test gas to pass through the test section, variations in the gas density across the 8.4-centimeter test section produce phase variations in the object beam and result in a varying interference pattern. A rotating drum camera with a 0.15-millimeter slit aligned perpendicular to the fringes is used to record the varying fringe shifts with a time resolution of about 3 microseconds. The average gas density across the test section is determined by measuring these fringe shifts.

Burner, Alpheus W.↗