Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INFRARED SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Infrared spectroscopy in astronomy

The use of infrared spectroscopy in astronomy has increased dramatically in the past ten years. The broad design considerations are discussed in terms of wavelength coverage and resolution. Three rough resolution ranges, lambda/Delta lambda of approximately 100, 1000 and 10,000, are identified in which various types of astronomical problems can be studied. Numerous existing systems are briefly discussed and references are given to more complete descriptions.

Houck, J. R.↗

Elevated Skin Blood Flow Influences Near Infrared Spectroscopy Measurements During Supine Rest

Near infrared spectroscopy is a non-invasive technique that allows determination of tissue oxygenation/blood flow based on spectrophotometric quantitation of oxy- and deoxyhemoglobin present within a tissue. This technique has gained acceptance as a means of detecting and quantifying changes in tissue blood flow due to physiological perturbation, such as that which is elicited in skeletal muscle during exercise. Since the NIRS technique requires light to penetrate the skin and subcutaneous fat in order to reach the muscle of interest, changes in skin blood flow may alter the NIRS signal in a fashion unrelated to blood flow in the muscle of interest. The aim of this study was to determine the contribution of skin blood flow to the NIRS signal obtained from resting vastus lateralis muscle of the thigh.

Lee, Stuart M. C.↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗

Mid-Infrared Spectroscopy of Persistent Leonid Trains

The first infrared spectroscopy in the 3-13 micron region has been obtained of several persistent Leonid meteor trains with two different instrument types, one at a desert ground-based site and the other on-board a high-flying aircraft. The spectra exhibit common structures assigned to enhanced emissions of warm CH4, CO2, CO and H2O which may originate from heated trace air compounds or materials created in the wake of the meteor. This is the first time that any of these molecules has been observed in the spectra of persistent trains. Hence, the mid-IR observations offer a new perspective on the physical processes that occur in the path of the meteor at some time after the meteor itself has passed by. Continuum emission is observed also, but its origin has not yet been established. No 10 micron dust emission feature has been observed.

Russell, Ray W.↗

Best Practices for the Application of Functional Near Infrared Spectroscopy to Operator State Sensing

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neuronal measurement technique with many advantages for application in operational and training contexts. Instrumentation and protocol improvements, however, are required to obtain useful signals and produce expeditiously self-applicable, comfortable and unobtrusive headgear. Approaches for improving the validity and reliability of fNIRS data for the purpose of sensing the mental state of commercial aircraft operators are identified, and an exemplary system design for attentional state monitoring is outlined. Intelligent flight decks of the future can be responsive to state changes to optimally support human performance. Thus, the identification of cognitive performance decrement, such as lapses in operator attention, may be used to predict and avoid error-prone states. We propose that attentional performance may be monitored with fNIRS through the quantification of hemodynamic activations in cortical regions which are part of functionally-connected attention and resting state networks. Activations in these regions have been shown to correlate with behavioral performance and task engagement. These regions lie beneath superficial tissue in head regions beyond the forehead. Headgear development is key to reliably and robustly accessing locations beyond the hair line to measure functionally-connected networks across the whole head. Human subject trials using both fNIRS and functional Magnetic Resonance Imaging (fMRI) will be used to test this system. Data processing employs Support Vector Machines for state classification based on the fNIRS signals. If accurate state classification is achieved based on sensed activation patterns, fNIRS will be shown to be useful for monitoring attentional performance.

Harrivel, Angela R.↗

Mid-infrared spectroscopy with a broadly tunable thin-film lithium niobate optical parametric oscillator

Mid-infrared spectroscopy, an important technique for sensing molecules, has encountered barriers from sources either limited in tuning range or excessively bulky for widespread use. We present a compact, efficient, and broadly tunable optical parametric oscillator surmounting these challenges. Leveraging dispersion-engineered thin-film lithium niobate-on-sapphire photonics and a singly resonant cavity allows broad, controlled tuning over an octave from 1.5–3.3 µm. The device generates >25mW of mid-infrared light at 3.2 µm with 15% conversion efficiency. The ability to precisely control the device’s mid-infrared emission enables spectroscopy of methane and ammonia, demonstrating our approach’s relevance for sensing. Our work signifies an important advance in nonlinear photonics miniaturization, bringing practical field applications of high-speed, broadband mid-infrared spectroscopy closer to reality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution infrared spectroscopy of planetary atmospheres

Various techniques for high-resolution infrared spectroscopy of planetary atmospheres are reviewed. Resolving powers of a million are now possible at 1-5 microns with Fourier transform spectrometers and at 10 microns with heterodyne spectrometers. The extension of high-resolution spectroscopy to the far-infrared is currently under development. The role of ground-based high-resolution spectroscopy compared to observations by spacecraft is discussed.

Tokunaga, A. T.↗

Infrared spectroscopy of the Herbig Ae-Be stars

Infrared spectroscopy from 1.5-2.3 microns is presented for nine Ae and Be stars believed to be pre-main-sequence. Brackett-gamma emission is seen in most or all the spectra, and higher-order Brackett recombination lines are visible in a number of the spectra. The strengths of the emission lines are generally less than or equal to the expected fluxes from H II regions which have been postulated to explain Balmer and Paschen continuum excesses in these stars. The circumstellar H II regions may be optically thick in some of the Brackett lines. No other lines are visible in the spectra, e.g., He or H2. The infrared continua are generally smooth; they confirm the presence of excess emission over that expected from the stellar photospheres. If the excesses are produced by thermal emission from dust, the dust grains must exist up to temperatures of 1300 K-1500 K.

Harvey, P. M.↗

Functional Near Infrared Spectroscopy: Watching the Brain in Flight

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neurological sensing technique applicable to optimizing human performance in transportation operations, such as commercial aviation. Cognitive state can be determined via pattern classification of functional activations measured with fNIRS. Operational application calls for further development of algorithms and filters for dynamic artifact removal. The concept of using the frequency domain phase shift signal to tune a Kalman filter is introduced to improve the quality of fNIRS signals in realtime. Hemoglobin concentration and phase shift traces were simulated for four different types of motion artifact to demonstrate the filter. Unwanted signal was reduced by at least 43%, and the contrast of the filtered oxygenated hemoglobin signal was increased by more than 100% overall. This filtering method is a good candidate for qualifying fNIRS signals in real time without auxiliary sensors

Harrivel, Angela↗

Functional Near Infrared Spectroscopy: Watching the Brain in Flight

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neurological sensing technique applicable to optimizing human performance in transportation operations, such as commercial aviation. Cognitive state can be determined via pattern classification of functional activations measured with fNIRS. Operational application calls for further development of algorithms and filters for dynamic artifact removal. The concept of using the frequency domain phase shift signal to tune a Kalman filter is introduced to improve the quality of fNIRS signals in real-time. Hemoglobin concentration and phase shift traces were simulated for four different types of motion artifact to demonstrate the filter. Unwanted signal was reduced by at least 43%, and the contrast of the filtered oxygenated hemoglobin signal was increased by more than 100% overall. This filtering method is a good candidate for qualifying fNIRS signals in real time without auxiliary sensors.

Harrivel, Angela↗

Quantitative infrared spectroscopy of aerosols: Mie theory modeling with experimental validation

Infrared spectroscopy is a well-established method for identifying solid, liquid, and gas-phase chemicals. Accurate infrared spectroscopic analysis requires reference libraries where library endmembers reflect all optical phenomena contributing to the observed spectra. Traditional spectral libraries most often contain molecular-based absorption spectra, but these do not account for the complex scattering effects that become significant when measuring aerosols. In this work, we combine the laboratory-derived, wavelength-dependent complex optical vectors ( n / k ) of liquid dioctyl sebacate (DOS) with Mie scattering theory and the Beer–Lambert law to generate synthetic infrared transmission spectra of aerosolized DOS. Additionally, we record experimental infrared transmission spectra using an FTIR spectrometer coupled to a simple aerosol chamber filled with a quantified number size distribution of aerosolized DOS. The modeled and measured spectra show strong agreement, with Mie scattering effects clearly altering the overall spectral shape as well as the positions and profiles of absorption features. The results demonstrate that synthetic spectra generated from n / k values can reliably capture aerosol-specific spectral behavior and thus serve as a foundation for building scalable, physics-based aerosol reference libraries to enable infrared spectroscopic detection of aerosols.

Salcido, Jessica M. O. [Pacific Northwest National↗

Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

Non-NASA Center↗

Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model

Variations in the levels of muscle hemoglobin and of myoglobin oxygen saturation can be detected non-invasively with near-infrared spectroscopy. This technique could be applied to the diagnosis of chronic compartment syndrome, in which invasive testing has shown increased intramuscular pressure associated with ischemia and pain during exercise. We simulated chronic compartment syndrome in ten healthy subjects (seven men and three women) by applying external compression, through a wide inflatable cuff, to increase the intramuscular pressure in the anterior compartment of the leg. The tissue oxygenation of the tibialis anterior muscle was measured with near-infrared spectroscopy during gradual inflation of the cuff to a pressure of forty millimeters of mercury (5.33 kilopascals) during fourteen minutes of cyclic isokinetic dorsiflexion and plantar flexion of the ankle. The subjects exercised with and without external compression. The data on tissue oxygenation for each subject then were normalized to a scale of 100 per cent (the baseline value, or the value at rest) to 0 per cent (the physiological minimum, or the level of oxygenation achieved by exercise to exhaustion during arterial occlusion of the lower extremity). With external compression, tissue oxygenation declined at a rate of 1.4 +/- 0.3 per cent per minute (mean and standard error) during exercise. After an initial decrease at the onset, tissue oxygenation did not decline during exercise without compression. The recovery of tissue oxygenation after exercise was twice as slow with compression (2.5 +/- 0.6 minutes) than it was without the use of compression (1.3 +/- 0.2 minutes).

NASA Discipline Musculoskeletal↗

Far-infrared Spectroscopy of Interstellar Gas

Research results of far-infrared spectroscopy with the Kuiper Airborne Observatory are discussed. Both high and intermediate resolution have been successfully employed in the detection of many new molecular and atomic lines including rotational transition of hydrides such as OH, H2O, NH3 and HCl; high J rotational transitions of CO; and the ground state fine structure transitions of atomic carbon, oxygen, singly ionized carbon and doubly ionized oxygen and nitrogen. These transitions have been used to study the physics and chemistry of clouds throughout the galaxy, in the galactic center region and in neighboring galaxies. This discussion is limited to spectroscopic studies of interstellar gas.

Phillips, T. G.↗

Infrared spectroscopy experiment on Mariner 9: Preliminary results

The Mariner 9 infrared spectroscopy experiment has provided good quality spectra of many areas of Mars, predominantly in the Southern Hemisphere. Large portions of the thermal emission spectra are significantly affected by dust with a silicon oxide content approximately corresponding to that of an intermediate igneous rock, implying that Mars has undergone a substantial geochemical differentiation. Derived temperature profiles indicate a warm daytime upper atmosphere with a strong warming over the south polar cap. Atmospheric water vapor is clearly observed over the south polar area and less strongly over other regions.

Hanel, R. A.↗

Martian tidal pressure and wind fields obtained from the Mariner 9 infrared spectroscopy experiment

Using temperature fields derived from the Mariner 9 infrared spectroscopy experiment, the Martian atmospheric tidal pressure and wind fields are calculated. Temperature as a function of local time, latitude, and atmospheric pressure level is obtained by secular and longitudinal averaging of the data. The resulting temperature field is approximated by a spherical harmonic expansion, retaining one symmetric and one asymmetric term for wavenumber zero and wavenumber one. Vertical averaging of the linearized momentum and continuity equations results in an inhomogeneous tidal equation for surface pressure fluctuations with the driving function related to the temperature field through the geopotential function and the hydrostatic equation. Solutions of the tidal equation show a diurnal fractional pressure amplitude approximately equal to one half of the vertically averaged diurnal fractional temperature amplitude.

Pirraglia, J. A.↗

Martian tidal pressure and wind fields obtained from the Mariner 9 infrared spectroscopy experiment

Using temperature fields derived from the Mariner 9 infrared spectroscopy experiment, the Martian atmospheric tidal pressure and wind fields are calculated. Temperature as a function of local time, latitude, and atmospheric pressure level is obtained by secular and longitudinal averaging of the data. The resulting temperature field is approximated by a spherical harmonic expansion, retaining one symmetric and one asymmetric term each for wavenumber zero and wavenumber one. Vertical averaging of the linearized momentum and continuity equations results in an inhomogeneous tidal equation for surface pressure fluctuations with the driving function related to the temperature field through the geopotential function and the hydrostatic equation. Solutions of the tidal equation show a diurnal fractional pressure amplitude approximately equal to one-half the vertically averaged diurnal fractional temperature amplitude.

Pirraglia, J. A.↗

Fourier Transform Infrared Spectroscopy of CF4 on the GEC Reference Cell

Fourier Transform Infrared Spectroscopy (FTIR) has been used to characterize inductively coupled CF4 plasmas in a GEC Reference Cell in-situ In examining these FTIR spectra, several assumptions and approximations of FTIR analysis are addressed. This includes the density dependence of cross-sections, non-linear effects in the addition of overlapping bands and the effect of spatial variations in density and temperature, This analysis demonstrates that temperatures extracted from MR spectra may provide a poor estimate of the true neutral plasma temperature. The FTIR spectra are dominated by unreacted CF, accounting for 40-60% of the gas products. The amount of CF4 consumption is found to have a marked dependence on power, and is nearly independent of pressure in the range of 10-50 mtorr. Small amounts of C2F6 are observed at low power. Also observed are etching products from the quartz window SiF4 COF2 and CO which occur in approximately equal ratios and together account for less than 10% of the gas. The concentrations of these species are nearly independent of pressure. CFx radicals are below the detection limit of this apparatus (approx. 1012/cc).

Rao, M. V. V. S.↗